PXIe-4300 Isolated Analog Input Module
The PXIe-4300 is an 8-channel, 16-bit PXI Express analog input module designed for isolated voltage and current measurements. It provides simultaneous sampling at up to 250 kS/s per channel, integrated signal conditioning and channel-to-channel isolation for demanding measurement applications.
When paired with the appropriate terminal block, the PXIe-4300 can measure signals ranging from low-level ±1 V inputs to high-voltage signals up to ±300 V. It is suitable for power measurements, battery testing, industrial equipment monitoring and other systems in which channels may operate at different common-mode voltages.
Key Features of the PXIe-4300
- 8 differential analog input channels
- 16-bit analog input resolution
- 250 kS/s simultaneous sampling per channel
- Dedicated ADC for each input channel
- Up to ±300 V measurements with the TB-4300B
- Up to 20 mA current measurements with the TB-4300C
- 300 Vrms channel-to-channel CAT II isolation
- 2,300 Vrms channel-to-earth withstand isolation for 5 seconds
- Software-selectable voltage ranges
- 10 kHz and 100 kHz programmable low-pass filters
- DC input coupling
- Two PFI lines for digital triggering
- PXI trigger and synchronization support
- NI-DAQmx driver compatibility
PXIe-4300 Technical Specifications
| Product Model | PXIe-4300 |
|---|---|
| Part Number | 781337-01 |
| Product Type | Isolated PXI Analog Input Module |
| Analog Input Channels | 8 differential channels |
| ADC Resolution | 16 bits |
| Maximum Sampling Rate | 250 kS/s per channel |
| Sampling Architecture | Simultaneous sampling |
| Module Input Ranges | ±1 V, ±2 V, ±5 V and ±10 V |
| High-Voltage Measurement Ranges | ±30 V, ±60 V, ±150 V and ±300 V with TB-4300B |
| Input Coupling | DC |
| Channel-to-Channel Isolation | 300 Vrms CAT II |
| Channel-to-Earth Withstand | 2,300 Vrms for 5 seconds |
| Input Bandwidth | 520 kHz |
| Low-Pass Filters | 10 kHz, 100 kHz or disabled |
| Filter Type | Second-order Butterworth |
| Digital Trigger Lines | 2 PFI lines |
| Bus Interface | x1 PXI Express |
| Front Connection | 96-pin DIN connector |
| Operating Temperature | 0°C to 55°C |
| Recommended Calibration Interval | 1 year |
Part Number and Terminal Block Options
| Model | Part Number | Measurement Type | Recommended Use |
|---|---|---|---|
| PXIe-4300 | 781337-01 | 8-channel isolated analog input | Base measurement module |
| TB-4300 | 781338-01 | Voltage inputs up to ±10 V | Low-voltage measurements |
| TB-4300B | 781338-02 | Voltage inputs up to ±300 V | High-voltage measurements |
| TB-4300C | 784280-01 | Current inputs up to 20 mA | Industrial current-loop measurements |
Simultaneous 250 kS/s Data Acquisition
The PXIe-4300 uses a dedicated analog-to-digital converter for each input channel. All eight channels can therefore acquire data simultaneously at rates up to 250 kS/s per channel without the timing skew associated with multiplexed input architectures.
Simultaneous sampling is valuable when measuring phase relationships, switching events, transient signals or multiple power-system parameters that must be compared at the same point in time.
Isolated High-Voltage Measurements
The PXIe-4300 provides 300 Vrms channel-to-channel CAT II isolation. This allows individual input channels to measure signals at different common-mode voltages while helping protect the measurement system and connected equipment.
For measurements above ±10 V, the TB-4300B terminal block is required. It uses a 30:1 attenuation network and additional protection circuitry to support voltage ranges of ±30 V, ±60 V, ±150 V and ±300 V.
High-voltage measurements require appropriate wiring, enclosures, personal protective equipment and safety procedures. The measurement category, working voltage and isolation limits must not be exceeded.
Programmable Input Ranges
With the standard TB-4300 terminal block, each channel supports software-selectable input ranges of ±1 V, ±2 V, ±5 V and ±10 V. Selecting the smallest suitable range can improve measurement resolution for lower-amplitude signals.
When using the high-voltage TB-4300B, the corresponding external ranges are ±30 V, ±60 V, ±150 V and ±300 V. NI-DAQmx can apply the stored scaling information associated with the terminal block.
Programmable Low-Pass Filtering
Each PXIe-4300 input channel includes a software-selectable second-order Butterworth low-pass filter. Available settings include 10 kHz, 100 kHz and filter bypass.
The filters can reduce high-frequency noise before digitization and help improve measurement stability. The bypass setting provides the widest available input bandwidth for applications that need to capture faster signal components.
Current Measurements with the TB-4300C
The TB-4300C terminal block enables the PXIe-4300 to acquire industrial current signals up to 20 mA. This configuration is suitable for monitoring common process instruments and transmitters using current-loop outputs.
Before connecting a current signal, verify that the TB-4300C is installed and that the channel is configured with the appropriate NI-DAQmx scaling. Do not connect a current loop using terminal block wiring intended only for direct voltage measurement.
Triggering and Synchronization
The PXIe-4300 includes two programmable function interface lines for digital input triggering. It also supports PXI trigger lines and PXI Express synchronization resources for coordinating acquisition with other instruments.
Multiple PXIe-4300 modules can be synchronized in a single chassis to create higher-channel-count isolated measurement systems. Synchronization is especially useful for three-phase power testing, battery systems and distributed industrial measurements.
Typical PXIe-4300 Applications
- High-voltage data acquisition
- Battery pack and battery management system testing
- Power supply validation
- Inverter and converter testing
- Motor drive measurements
- Three-phase power monitoring
- Industrial equipment monitoring
- Automotive electrical testing
- Rail and transportation power-system testing
- Industrial 20 mA current-loop acquisition
- Automated production testing
- Research and laboratory measurement systems
Software and Driver Support
The PXIe-4300 is supported by the NI-DAQmx driver, which provides configuration, acquisition, triggering, synchronization and scaling functions. Applications can be developed using NI LabVIEW, LabWindows/CVI, C/C++, C# and supported Python environments.
NI FlexLogger can also be used for supported interactive data acquisition and logging applications. NI TestStand can integrate PXIe-4300 measurements into automated validation and production test sequences.
PXI Chassis and System Integration
The PXIe-4300 is an x1 PXI Express peripheral module compatible with supported PXI Express and PXI Express hybrid slots. It requires a compatible PXI chassis and embedded or remote controller.
Suitable chassis options include the PXIe-1092, PXIe-1085 and other NI PXI Express chassis with sufficient power, cooling and slot capacity.
Keep unused chassis positions fitted with appropriate filler panels to maintain the airflow required for reliable module operation.
Installation and Troubleshooting
Module Is Not Detected
Confirm that the PXIe-4300 is installed in a compatible PXI Express or hybrid peripheral slot. Check the chassis connection, controller operation and NI-DAQmx installation before refreshing the hardware configuration in NI Measurement & Automation Explorer.
High-Voltage Range Is Not Available
Verify that the TB-4300B terminal block is installed and correctly identified. The base PXIe-4300 input circuitry supports ranges up to ±10 V, while measurements up to ±300 V require the attenuation and protection provided by the TB-4300B.
Measurements Are Noisy
Check grounding, shielding and cable routing. Select the 10 kHz or 100 kHz low-pass filter when the application does not require the full input bandwidth. Keep signal cables separated from switching power circuits and other noise sources.
Channels Show Different Measurements
Confirm that the input range, terminal block scaling and filter setting are configured correctly for every channel. Also allow the module to warm up for at least 15 minutes before making measurements that require rated accuracy.
Current-Loop Measurements Are Incorrect
Verify that the TB-4300C terminal block is installed and that the signal is wired as a current input. Check loop polarity, available loop power and the configured current scaling.
PXIe-4300 Comparison with Similar Analog Input Modules
| Model | Primary Capability | Recommended Selection |
|---|---|---|
| PXIe-4300 | 8 isolated channels, 16-bit, 250 kS/s/ch, up to ±300 V | Fast isolated high-voltage measurements |
| PXIe-4302 | 32-channel filtered analog input | Higher channel count and precision voltage acquisition |
| PXIe-4303 | 32-channel, 24-bit simultaneous analog input | High-resolution voltage, current and thermocouple measurements |
| PXIe-4304 | 32-channel, 24-bit higher-voltage analog input | Moderate-voltage measurements requiring more channels |
| PXIe-4330 | Bridge and strain measurement input | Load, pressure, torque and strain measurements |
Recommended Related Products
- PXIe-4303 Analog Input Module – offers 32 channels and 24-bit resolution for precision measurements
- PXIe-4304 Analog Input Module – suitable for higher-channel-count voltage acquisition
- PXIe-4330 Bridge Input Module – designed for strain, load, pressure and torque sensors
- PXIe-4353 Temperature Input Module – provides high-channel-count thermocouple measurements
- PXIe-1092 PXI Express Chassis – provides a platform for synchronized modular data acquisition systems
Additional compatible hardware is available in our NI PXI modules category.
How to Select the PXIe-4300
Choose the PXIe-4300 when an application requires simultaneous, channel-isolated measurements at rates up to 250 kS/s per channel. Select the terminal block according to the signal being measured:
- Choose the TB-4300 for voltage measurements up to ±10 V.
- Choose the TB-4300B for isolated high-voltage measurements up to ±300 V.
- Choose the TB-4300C for industrial current measurements up to 20 mA.
Before purchasing, confirm the voltage range, measurement category, isolation requirements, sample rate, filter setting, terminal block and PXI chassis compatibility.
Why Choose the PXIe-4300?
The PXIe-4300 combines simultaneous acquisition, integrated filtering and channel-to-channel isolation in one compact PXI Express module. Its interchangeable terminal blocks allow the same module platform to support low-voltage, high-voltage and industrial current measurements.
Frequently Asked Questions
How many analog input channels does the PXIe-4300 provide?
The PXIe-4300 provides eight differential analog input channels with a dedicated 16-bit ADC for each channel.
What is the maximum sampling rate?
All eight channels can sample simultaneously at rates up to 250 kS/s per channel.
Can the PXIe-4300 measure ±300 V directly?
The PXIe-4300 requires the TB-4300B high-voltage terminal block for measurements up to ±300 V. The module’s native input ranges extend up to ±10 V.
What isolation does the PXIe-4300 provide?
The module provides 300 Vrms channel-to-channel CAT II isolation and 2,300 Vrms channel-to-earth withstand isolation for five seconds.
Can the PXIe-4300 measure 20 mA current signals?
Yes. Industrial current signals up to 20 mA can be acquired when the module is used with the TB-4300C terminal block.
Which filters are available?
Each channel provides software-selectable 10 kHz and 100 kHz second-order Butterworth low-pass filters. The filter can also be disabled when maximum bandwidth is required.
What is the PXIe-4300 part number?
The standard NI part number for the PXIe-4300 is 781337-01.
Request a Quote for the PXIe-4300
Contact us for current availability, lead time and project pricing for the PXIe-4300 Isolated Analog Input Module. We can also help identify the correct TB-4300 terminal block, PXI chassis, controller and software for your measurement system.