National Instruments PXI-6514 64-Channel ±30 VDC Bank-Isolated PXI Digital I/O Module, 32 Inputs, 32 Outputs

Product Introduction

The NI PXI-6514 is a 64-channel, bank-isolated PXI digital I/O module designed for industrial control, automated test, machine monitoring, actuator control, relay interfacing, and other applications requiring reliable high-voltage digital I/O.

The PXI-6514 provides 32 sink/source digital input channels and 32 source digital output channels with support for industrial voltage levels up to ±30 VDC.

Unlike general-purpose TTL digital I/O modules, the PXI-6514 is designed specifically for industrial signal interfacing. Its bank-isolated architecture, programmable power-up states, digital I/O watchdogs, and programmable input filters provide additional protection and reliability for automated equipment and industrial test systems.

Product Overview

The National Instruments PXI-6514 is an industrial digital I/O interface that combines 64 digital channels in a single PXI module.

The module consists of:

  • 32 sink/source digital inputs
  • 32 source digital outputs
  • 64 total digital channels
  • Eight banks of isolated channels
  • Industrial 24 V logic compatibility
  • Up to ±30 VDC signal capability

This architecture makes the PXI-6514 particularly suitable for connecting PXI automated test systems to industrial sensors, switches, relays, actuators, PLC-related signals, and other field devices.

Key Features

64 Digital I/O Channels

The PXI-6514 provides a total of 64 digital I/O channels.

Channel TypeNumber of Channels
Digital Inputs32
Digital Outputs32
Total Digital Channels64

The high channel count allows a single PXI module to monitor and control a large number of industrial digital signals.

32 Sink/Source Digital Inputs

The PXI-6514 provides 32 digital input channels designed to interface with industrial digital signals.

The sink/source input architecture provides flexibility when connecting different types of industrial devices and control signals.

Typical input devices include:

  • Limit switches
  • Proximity sensors
  • Push buttons
  • Relay contacts
  • Industrial sensors
  • PLC outputs
  • Machine status signals

32 Source Digital Outputs

The PXI-6514 provides 32 source digital output channels for controlling compatible industrial devices.

Typical output applications include:

  • Relay control
  • Solenoid control
  • Indicator control
  • Actuator interfacing
  • Machine control
  • Fixture control
  • Automated test sequencing

±30 VDC Industrial Digital I/O

The PXI-6514 is designed for industrial digital signals with voltage capability up to ±30 VDC.

This makes the module significantly better suited to industrial automation than conventional 3.3 V or 5 V TTL digital I/O hardware.

  • Industrial digital signal interfacing
  • 24 V control systems
  • Industrial sensors
  • Relays and actuators
  • Automated machinery
  • Production test fixtures

24 V Logic Level

The PXI-6514 is designed for 24 V industrial digital logic, making it suitable for common industrial automation and control applications.

24 V digital signals are widely used in PLCs, sensors, actuators, relays, machine control systems, and industrial test equipment.

Bank-Isolated Architecture

One of the most important features of the PXI-6514 is its bank-isolated digital I/O architecture.

The module provides eight banks of isolated channels, helping separate groups of field signals from one another and from the PXI system.

Bank isolation is particularly useful for:

  • Industrial environments
  • Different field power domains
  • Noise reduction
  • Ground-loop management
  • Machine control systems
  • Automated test fixtures

Up to 350 mA Current Drive per Channel

The PXI-6514 provides a maximum single-channel digital I/O current drive of up to 350 mA under applicable operating conditions.

This output capability allows the module to interface with compatible industrial loads and control devices.

Actual system design should always consider the per-channel, per-bank, total current, external supply, thermal, and load requirements specified by NI.

Programmable Power-Up States

The PXI-6514 supports programmable power-up states.

Engineers can configure the initial state of digital outputs in software so that connected industrial equipment starts in a predictable condition when the system powers on.

This feature is especially useful when outputs control:

  • Relays
  • Actuators
  • Solenoids
  • Test fixtures
  • Machine control circuits

Digital I/O Watchdog

The PXI-6514 includes digital I/O watchdog functionality for fault management.

If the computer or application stops responding, the watchdog can switch digital outputs to predefined safe states.

This capability helps automated systems detect and recover from software or controller failures while reducing the risk of leaving industrial actuators in an unintended state.

Programmable Input Filters

The PXI-6514 provides programmable digital input filters.

These filters can suppress short glitches and spikes and provide debouncing for mechanical switches and relays.

Typical applications include:

  • Mechanical switch monitoring
  • Relay contact monitoring
  • Noisy industrial signals
  • Limit switch acquisition
  • Production fixture inputs

PXI Hybrid Bus Connector

The PXI-6514 uses a PXI Hybrid bus connector, allowing integration into compatible PXI modular test and measurement systems.

The PXI architecture allows the module to operate alongside analog measurement, switching, communication, motion, and other instrumentation within the same automated test platform.

Technical Specifications

ParameterDescription
Product TypeBank-Isolated PXI Digital I/O Module
ModelNI PXI-6514
Part Number778965-01
Total Digital Channels64
Digital Input Channels32
Digital Output Channels32
Bidirectional Digital Channels0
Input TypeSink / Source
Output TypeSource
Digital I/O VoltageUp to ±30 VDC
Digital Logic Level24 V
Maximum Single-Channel Current Drive350 mA
Isolation ArchitectureBank Isolated
Number of Isolated Banks8
Programmable Power-Up StatesSupported
Digital I/O WatchdogSupported
Programmable Input FiltersSupported
Bus ConnectorPXI Hybrid
Operating Temperature0 °C to 55 °C
PXI DimensionsApproximately 16 cm × 10 cm
PXI WeightApproximately 172.9 g
Primary ApplicationsIndustrial Automation, Machine Control, Automated Test, Relay Control and Digital Monitoring

What Is an Industrial Digital I/O Module?

An industrial digital I/O module connects a computer-based test or control system to discrete electrical signals used by industrial equipment.

Digital inputs detect ON/OFF states from field devices, while digital outputs generate ON/OFF control signals for external equipment.

Typical devices include:

  • Sensors
  • Switches
  • Relays
  • Solenoids
  • Actuators
  • PLCs
  • Industrial controllers
  • Automated test fixtures

The PXI-6514 combines both input monitoring and output control within a single PXI module.

Understanding Sink/Source Inputs

The PXI-6514 provides 32 sink/source digital inputs, giving engineers flexibility when interfacing with industrial digital signals.

Sinking and sourcing terminology describes the direction of conventional current flow between a field device and the I/O interface.

Compatibility should always be verified according to the wiring architecture, external power supply, sensor output type, and PXI-6514 electrical specifications.

Understanding Source Outputs

The PXI-6514 provides 32 sourcing digital outputs.

A sourcing output supplies current toward the connected load when activated. This architecture is commonly used in industrial control systems.

Before connecting a load, verify:

  • Load voltage
  • Load current
  • External supply voltage
  • Output current limits
  • Bank current requirements
  • Wiring polarity

Bank Isolation Explained

Bank isolation separates groups of digital channels electrically rather than isolating every individual channel separately.

The PXI-6514 contains eight isolated banks, allowing groups of industrial signals to operate with electrical separation appropriate to the supported architecture.

Bank isolation can help:

  • Reduce ground-loop problems
  • Improve noise immunity
  • Protect measurement and control hardware
  • Interface different industrial signal groups
  • Improve system reliability

Industrial Sensor Monitoring

The 32 digital inputs can monitor discrete status signals from compatible industrial sensors.

Typical applications include:

  • Proximity sensors
  • Photoelectric sensors
  • Limit switches
  • Machine status signals
  • Safety interlock status
  • Position detection

Programmable input filtering is particularly useful when input signals contain switching noise or mechanical contact bounce.

Relay and Actuator Control

The PXI-6514’s digital outputs can control compatible industrial loads directly or interface with external relay and driver circuits.

Typical applications include:

  • Relay activation
  • Solenoid control
  • Valve control
  • Indicator control
  • Fixture actuation
  • Automated machine sequencing

Load voltage and current requirements should always be checked before directly connecting an actuator to the PXI-6514.

Automated Test Fixture Control

The PXI-6514 is particularly suitable for automated test fixtures that require many discrete control and status signals.

A typical automated test architecture can be represented as:

Test Software → PXI Controller → PXI-6514 → Relay / Fixture / Sensor → DUT

The digital inputs can monitor fixture and DUT status while the digital outputs control relays, actuators, indicators, and other test hardware.

Production Test Applications

Production test systems frequently require digital I/O for controlling fixtures and monitoring DUT status.

The PXI-6514 can perform functions such as:

  • Fixture control
  • DUT presence detection
  • Relay switching control
  • Pass/fail indicator control
  • Safety interlock monitoring
  • Machine status monitoring
  • Automated test sequencing

Machine Control Applications

The industrial voltage capability and isolation architecture of the PXI-6514 make it suitable for machine monitoring and control applications.

The module can connect PXI software applications with compatible 24 V industrial control signals used throughout automated equipment.

Typical examples include:

  • Assembly machines
  • Automated inspection systems
  • Production equipment
  • Test stands
  • Laboratory automation
  • Industrial research systems

Fault Recovery and Safe-State Control

Industrial control systems must consider what happens when the controlling computer or application fails.

The PXI-6514’s watchdog functionality allows outputs to transition to predefined states if a fault condition is detected.

Combined with programmable power-up states, this provides additional control over output behavior during:

  • System startup
  • Application failure
  • Controller failure
  • Communication interruption
  • System recovery

PXI-6514 vs Standard TTL Digital I/O

FeaturePXI-6514Typical TTL Digital I/O
Primary ApplicationIndustrial Digital I/OLogic-Level Digital I/O
Logic Environment24 V Industrial3.3 V / 5 V
Maximum Voltage ClassUp to ±30 VDCTypically Low Voltage
IsolationBank IsolatedOften Non-Isolated
Digital Inputs32Device Dependent
Digital Outputs32Device Dependent
WatchdogSupportedDevice Dependent
Input FilteringProgrammableDevice Dependent
Best UseIndustrial Sensors and ActuatorsDigital Logic and Electronics

PXI-6514 vs PCI-6514

The PXI-6514 and PCI-6514 provide similar industrial digital I/O functionality but use different hardware platforms.

FeaturePXI-6514PCI-6514
PlatformPXIPCI
Total Digital Channels6464
Digital Inputs3232
Digital Outputs3232
Industrial Voltage±30 VDC±30 VDC
IsolationBank IsolatedBank Isolated
Best ApplicationModular PXI Test SystemsDesktop PC-Based Systems

Choose the PXI-6514 when the application is based on a modular PXI test platform. The PCI-6514 is more appropriate for compatible legacy desktop PC systems using a PCI interface.

PXI-6514 in a Complete PXI System

The PXI-6514 can provide industrial digital control and monitoring within a larger automated PXI test system.

A complete system may combine the PXI-6514 with:

  • PXI chassis
  • PXI embedded or remote controller
  • Multifunction DAQ modules
  • Analog input modules
  • Analog output modules
  • PXI switching modules
  • Digital multimeters
  • Programmable power supplies
  • Communication interfaces

This modular architecture allows digital control, analog measurement, switching, stimulus generation, and communication to operate within one automated test platform.

Software and Driver Support

The PXI-6514 is designed for software-controlled digital I/O applications using NI data acquisition software and drivers.

Software-based operation allows engineers to:

  • Read digital input states
  • Control digital outputs
  • Configure input filters
  • Configure power-up states
  • Configure watchdog behavior
  • Integrate I/O into automated test sequences

Industries

  • Industrial Automation
  • Electronic Manufacturing
  • Automotive Test
  • Aerospace and Defense
  • Machine Building
  • Production Test
  • Laboratory Automation
  • Research and Development
  • Automated Test Equipment

Applications

Industrial Digital I/O

The PXI-6514 interfaces PXI systems with industrial 24 V digital signals for monitoring and control applications.

Automated Test Fixture Control

The 32 digital outputs can control compatible relays, actuators, indicators, and fixture components while 32 digital inputs monitor status signals.

Machine Monitoring

Digital inputs can acquire discrete signals from switches, proximity sensors, machine controllers, and other industrial devices.

Relay and Solenoid Control

Source outputs can interface with compatible industrial relays and solenoids within the electrical limits specified for the PXI-6514.

Production Testing

The PXI-6514 can provide digital control and monitoring for automated production test stations and manufacturing equipment.

Safety and Interlock Monitoring

Digital inputs can monitor compatible interlock and machine-status signals as part of a broader control system. System-level safety functions should be implemented according to the applicable machinery and functional safety requirements.

Recommended Related Products

NI PXI-6514 64-channel bank-isolated industrial digital I/O module with 32 sink/source inputs and 32 source outputs.
NI PXI-6515 Industrial isolated digital I/O module for applications requiring a different input/output channel architecture.
NI PXI-6529 Isolated digital I/O module suitable for industrial monitoring and control applications requiring electrical isolation.
NI PXIe-6612 Counter/timer module for applications requiring event counting, pulse generation, frequency measurement, and encoder interfacing.

Why Choose NI PXI-6514?

  • 64 total digital channels
  • 32 sink/source digital inputs
  • 32 source digital outputs
  • ±30 VDC industrial signal capability
  • 24 V industrial logic
  • Eight banks of isolated channels
  • Up to 350 mA single-channel current drive
  • Programmable power-up states
  • Digital I/O watchdog functionality
  • Programmable input filters
  • Switch and relay debouncing
  • PXI Hybrid interface
  • Suitable for industrial sensors
  • Suitable for actuator and relay control
  • Designed for automated test and industrial control

Frequently Asked Questions

What is the NI PXI-6514?

The NI PXI-6514 is a 64-channel bank-isolated PXI digital I/O module designed for industrial monitoring, control, automated test, relay interfacing, and machine automation applications.

What is the part number of the PXI-6514?

The NI PXI-6514 part number is 778965-01.

How many channels does the PXI-6514 have?

The PXI-6514 provides 64 total digital channels, consisting of 32 digital inputs and 32 digital outputs.

How many digital inputs does the PXI-6514 provide?

The PXI-6514 provides 32 sink/source digital input channels.

How many digital outputs does the PXI-6514 provide?

The PXI-6514 provides 32 sourcing digital output channels.

Are the PXI-6514 channels bidirectional?

No. The PXI-6514 has dedicated input and output channels rather than bidirectional digital lines. It provides 32 input-only channels and 32 output-only channels.

What voltage does the PXI-6514 support?

The PXI-6514 is designed for industrial digital I/O applications with signal capability up to ±30 VDC and is commonly associated with 24 V industrial logic systems.

Is the PXI-6514 isolated?

Yes. The PXI-6514 uses a bank-isolated architecture with eight banks of isolated channels.

What is the maximum current drive of the PXI-6514?

NI specifies a maximum single-ended digital I/O channel current drive of 350 mA. Actual allowable current depends on the electrical configuration and operating conditions, so the complete NI specifications should be checked when sizing loads.

Does the PXI-6514 support programmable power-up states?

Yes. Programmable power-up states allow engineers to define initial output conditions to help ensure predictable behavior when the system starts.

Does the PXI-6514 have a watchdog?

Yes. Digital I/O watchdog functionality can switch outputs to configurable safe states if a computer or application fault occurs.

Does the PXI-6514 support digital filtering?

Yes. Programmable input filters can remove short glitches and spikes and provide debouncing for switches and relay contacts.

Can the PXI-6514 control relays?

Yes. The PXI-6514 can interface with compatible industrial relays provided that the relay voltage, current, wiring, external power supply, and other electrical requirements are within the module’s specifications.

Can the PXI-6514 be used with 24 V industrial sensors?

Yes. The PXI-6514 is designed for industrial digital I/O and is suitable for compatible 24 V sensors and control signals. The exact sensor output architecture and wiring requirements should be verified before connection.

What is the difference between PXI-6514 and PCI-6514?

The primary difference is the hardware platform. The PXI-6514 is designed for modular PXI systems, while the PCI-6514 is designed for compatible PCI-based computers. Both provide 32 digital inputs and 32 digital outputs for industrial digital I/O applications.

What applications are suitable for the PXI-6514?

Typical applications include industrial automation, machine monitoring, automated test fixture control, relay and actuator control, production testing, discrete sensor monitoring, laboratory automation, and industrial control.

What should I check before purchasing a PXI-6514?

Before purchasing a PXI-6514, verify the required number of digital inputs and outputs, sink/source wiring architecture, signal voltage, load current, bank isolation requirements, external power supply, connector and cabling requirements, PXI chassis compatibility, and software/driver compatibility.

Conclusion

The NI PXI-6514 64-Channel Bank-Isolated PXI Digital I/O Module combines 32 sink/source digital inputs, 32 source digital outputs, ±30 VDC industrial signal capability, eight banks of isolated channels, programmable power-up states, digital I/O watchdogs, and programmable input filters. These features make it particularly suitable for industrial automation, machine monitoring, relay and actuator control, automated test fixtures, production testing, and other applications requiring reliable 24 V industrial digital I/O within a PXI system.

Part Number(s): 778965-01

Specifications

Bus Connector: PXI Hybrid
Single-Ended Digital I/O Channel Current Drive: 350 mA
Digital I/O Logic Levels: 24 V
Number of Digital Input Only Channels: 32
Number of Digital Output Only Channels: 32
Number of Bidirectional Digital Channels: –
Digital Input Voltage Range: -30 V to 30 V
Output Voltage Range: -30 V to 30 V
Maximum Clock Rate: –
Signaling Type: Single-Ended

Brand

National Instruments

Related Products

Recently Viewed

Frequently Asked Questions

Yes. We can provide new and original products sourced through reliable supply channels. Depending on availability and customer requirements, selected models may also be available in used or refurbished condition. Please confirm the required condition when requesting a quotation.

Please contact us with the required model number, quantity, and application requirements. We provide competitive quotations and project-based pricing according to your purchasing needs.

Stock availability changes regularly. Some models are available for immediate shipment, while others require factory ordering or sourcing. Contact us with the exact model and part number for the latest availability.

Yes, we provide worldwide shipping solutions for customers in different countries and regions. We can arrange reliable logistics services based on your destination and delivery requirements.

Yes, our technical team can help verify specifications, system compatibility, accessories, and product selection based on your application requirements.