Показаны все (15)
Фильтр по цене
Фильтровать по брендам
- Национальные инструменты
- Системы PXI
- PXI Шасси
- PXI Контроллер
- Модули PXI
- PXI Semiconductor Test
- PXI FPGA and RIO Modules
- PXI MXI Interfaces
- PXI Programmable Power Supplies & SMU
- PXI Sensor Measurements
- Генераторы сигналов PXI
- PXI Vision
- Сбор данных PXI
- Осциллографы/Цифровые преобразователи PXI
- PXI Счетчики/Таймеры
- PXI РЧ и беспроводное тестирование
- PXI GPIB, Ethernet and VXI
- PXI-коммутаторы
- Цифровые мультиметры PXI
- Цифровой ввод-вывод PXI
- Промышленная связь PXI
- Динамический анализ сигналов PXI
- Передача данных PXI
- CompactDAQ Systems
- CompactRIO Systems
- PCI Modules
- USB Devices
- Устройство программно-определяемого радио USRP
- Системы PXI
- ключи
- ТекТроникс
NI PXI RF and Wireless Test Modules
NI PXI RF and Wireless Test modules provide software-controlled RF signal generation, vector signal analysis, spectrum measurement, wideband transceiver operation and real-time signal processing inside PXI and PXI Express systems. They are used for RFIC characterization, wireless-device validation, semiconductor production test, radar, aerospace, defense, spectrum monitoring and communications research.
Selecting the correct RF instrument requires more than matching the carrier-frequency range. Engineers must also consider instantaneous bandwidth, RF input and output levels, dynamic range, phase noise, modulation quality, channel count, synchronization, FPGA processing, data throughput, RF path accessories and software licensing.
Main Types of PXI RF Test Instruments
| Instrument Type | Primary Function | Типичные применения | Key Selection Criteria |
|---|---|---|---|
| Векторный приемопередатчик сигналов | Combines RF signal generation, RF analysis and FPGA-based processing | Wireless validation, RFIC test, radar and automated production test | Frequency range, generation and analysis bandwidth, EVM, FPGA and synchronization |
| Vector Signal Analyzer | Acquires RF signals while preserving amplitude and phase information | Spectrum, modulation, transmitter and signal-intelligence measurements | Frequency coverage, instantaneous bandwidth, noise floor and dynamic range |
| Vector Signal Generator | Generates digitally modulated RF waveforms | Receiver testing, communications validation and RF component stimulus | Modulation bandwidth, output level, EVM, phase noise and waveform memory |
| RF Analog Signal Generator | Produces programmable CW, swept or supported analog-modulated RF signals | Amplifier, filter, mixer and receiver characterization | Frequency range, power range, tuning speed, phase noise and spectral purity |
| RF Downconverter | Converts an RF signal to a lower-frequency signal for digitization and analysis | Modular VSA systems and legacy RF-analysis architectures | Frequency range, conversion bandwidth, local oscillator and compatible digitizer |
| RF Preamplifier | Increases low-level RF signals before analysis | Weak-signal measurement, monitoring and noise-sensitive receiver testing | Frequency range, gain, noise figure, compression and bypass operation |
| FlexRIO RF Digitizer | Provides high-speed conversion and FPGA-accessible signal processing | Custom radar, spectrum monitoring, communications research and streaming | Analog bandwidth, sample rate, resolution, FPGA resources and data throughput |
VSA, VSG and VST Comparison
| Architecture | Signal Generation | Signal Analysis | Best Fit |
|---|---|---|---|
| Vector Signal Analyzer | No | Да | Transmitter measurements, spectrum analysis and signal monitoring |
| Vector Signal Generator | Да | No | Receiver stimulus and generation of modulated RF waveforms |
| Separate VSA and VSG | Да | Да | Systems requiring independent analyzer and generator configurations |
| Векторный приемопередатчик сигналов | Да | Да | Integrated generation, analysis, FPGA processing and fast automated test |
A VST can reduce the number of separate instruments in a test system, but it should not automatically replace a dedicated analyzer or generator. The decision depends on frequency coverage, measurement quality, channel requirements, existing software and whether application-specific FPGA processing is required.
Representative NI PXI RF and Wireless Test Modules
| Модель | Unique Category | Core Architecture | Best Fit |
|---|---|---|---|
| PXI-5652 | Legacy PXI RF Signal Source | Software-controlled RF signal generation for established PXI systems | Maintenance, expansion and replacement of legacy RF test platforms |
| PXIe-5606 | RF Downconverter | Frequency-conversion front end used as part of a compatible RF-analysis system | Modular VSA configurations requiring a separate RF front end and digitizer |
| PXIe-5654 | Microwave Analog Signal Generator | PXIe RF source available in configurations extending to 10 GHz or 20 GHz | CW stimulus, frequency sweeps and microwave component characterization |
| PXIe-5668 | Wideband Vector Signal Analyzer | VSA configurations covering up to 14 GHz or 26.5 GHz with wide instantaneous bandwidth | RF spectrum, modulation, radar and wideband transmitter analysis |
| PXIe-5698 | RF Preamplifier | Single-slot broadband preamplifier designed to extend weak-signal capability | Low-level RF acquisition and expanded PXIe-5668 measurement sensitivity |
| PXIe-5820 | Baseband Vector Signal Transceiver | Wideband differential I/Q transceiver with 1 GHz complex I/Q bandwidth and programmable FPGA resources | Baseband research, custom I/Q processing and RF front-end development |
| PXIe-5830 | Microwave Wideband Vector Signal Transceiver | 5 GHz to 12 GHz VST with 1 GHz instantaneous bandwidth and bidirectional test ports | Wideband WLAN, microwave IF and compatible mmWave test architectures |
| PXIe-5841 | General-Purpose Wideband RF VST | Second-generation software-defined VST integrating RF generation, analysis and FPGA processing | RFIC, cellular, wireless connectivity and high-throughput production test |
| PXIe-5764 | High-Resolution FlexRIO Digitizer | High-speed analog conversion with FPGA-accessible digital processing | Custom wideband acquisition and application-specific signal-processing systems |
| PXIe-5775 | Ultra-High-Speed FlexRIO Digitizer | High-sample-rate acquisition combined with reconfigurable FPGA processing | Radar, transient RF capture and custom high-throughput digital signal processing |
| PXIe-5785 | FlexRIO Transceiver Module | High-speed analog input and output with FPGA-based processing | Custom RF stimulus-response, prototyping and closed-loop signal applications |
These models represent different RF architectures and should not be compared solely by model number or maximum frequency. Verify the exact part number, frequency option, bandwidth, module combination, cable kit, software license and chassis requirements before ordering.
How to Select a PXI RF and Wireless Test Module
1. Determine Whether You Need Generation, Analysis or Both
Start by defining the direction of the RF signal path. Receiver testing normally requires a controlled RF source, while transmitter testing requires an analyzer. A transceiver or complete RF component test may require both generation and analysis.
Choose between:
- A dedicated RF or vector signal generator
- A dedicated vector signal analyzer
- Separate generator and analyzer modules
- An integrated vector signal transceiver
- A custom digitizer and FPGA architecture
2. Define the Required Frequency Range
The instrument must cover the DUT’s fundamental operating bands and any additional frequencies that must be generated or measured. Include harmonics, intermediate frequencies, adjacent bands, out-of-band emissions and future product variants where relevant.
Frequency range defines where the instrument can tune. It does not define how much spectrum the instrument can acquire or generate at one time.
3. Determine the Instantaneous Bandwidth
Instantaneous bandwidth is the continuous span of RF spectrum that can be generated or analyzed without retuning. It is a separate specification from the maximum carrier frequency.
| Параметр | What It Defines | Why It Matters |
|---|---|---|
| Диапазон частот | Minimum and maximum carrier frequencies | Determines which RF bands can be tested |
| Мгновенная пропускная способность | Spectrum captured or generated in one acquisition | Determines whether the complete modulated signal can be processed at once |
| Sample Rate | Digital conversion rate inside the instrument | Supports waveform and I/Q processing bandwidth |
| Frequency Resolution | Smallest programmable tuning increment | Affects swept measurements and precise signal placement |
Wide instantaneous bandwidth is important for 5G, Wi-Fi, carrier aggregation, radar pulses, chirps, electronic warfare waveforms and wideband spectrum monitoring.
4. Specify RF Input and Output Levels
For signal generation, define the minimum and maximum output power at the DUT reference plane. For analysis, specify the expected signal range, maximum safe input and weakest signal that must be measured.
The RF path may include attenuators, amplifiers, cables, switches and fixtures. Their combined gain or loss must be included when determining the level at the instrument connector.
Never apply a signal that exceeds the analyzer’s maximum safe input. High-power amplifiers and transmitters may require external attenuation, directional couplers or other protection.
5. Review Dynamic Range and Noise Performance
Dynamic range determines how effectively the analyzer can distinguish small signals from larger nearby signals, instrument noise and distortion. Depending on the application, compare:
- Displayed or average noise level
- Third-order intercept performance
- Spurious-free dynamic range
- Harmonic and intermodulation distortion
- Amplitude accuracy
- Compression behavior
- Available preamplification
A preamplifier such as the PXIe-5698 can improve weak-signal sensitivity, but it can also reduce the input level available before compression. Use it according to the signal environment and required dynamic range.
6. Evaluate Phase Noise and Frequency Accuracy
Phase noise affects measurements involving oscillators, synthesizers, narrowband signals, radar, communication systems and frequency conversion. Low phase noise is also important when a generator must provide a clean stimulus for receiver or component testing.
Frequency accuracy depends on the instrument timebase and external reference configuration. Systems requiring multiple coherent instruments should use a defined reference-clock architecture.
7. Define Modulation Quality Requirements
Modern communication systems require measurement of both amplitude and phase behavior. Common analysis parameters include:
- Error vector magnitude
- Channel power
- Occupied bandwidth
- Adjacent-channel power
- Spectral emissions
- Frequency error
- Constellation behavior
- Modulation accuracy
The test instrument’s residual EVM, noise and distortion should be sufficiently better than the DUT requirement. Otherwise, instrument uncertainty can consume too much of the available test margin.
8. Confirm the Required Wireless Standard
Identify the signal format and measurement standard before selecting software and hardware. Applications may include cellular, WLAN, Bluetooth, satellite communication, GNSS, proprietary radios, radar or custom digital modulation.
Hardware bandwidth alone does not provide standards-based measurements. The required RFmx measurement personality, waveform license or application software must also support the intended technology and instrument model.
9. Determine the Number of RF Channels
Single-channel systems are suitable for many component and device tests. MIMO, beamforming, phased-array and parallel-production systems may require multiple synchronized transmit and receive channels.
Define:
- Number of transmit channels
- Number of receive channels
- Required phase relationship
- Channel-to-channel skew
- Local oscillator sharing
- Trigger and clock distribution
- Calibration method
10. Review Test Speed and Tuning Time
Production-test throughput can depend on frequency tuning, power settling, waveform loading, acquisition time, analysis time and communication with the DUT. Maximum RF performance alone does not determine total test speed.
For repeated measurements, evaluate whether the instrument and software can reuse configurations, perform list-mode operations, process measurements in parallel or use FPGA-based acceleration.
FPGA Processing in PXI RF Systems
Selected VST and FlexRIO instruments provide programmable FPGA resources close to the RF or converter hardware. FPGA processing can reduce host-data transfer, implement deterministic logic and shorten the response time between acquisition and generation.
Possible FPGA applications include:
- Custom triggering
- Real-time spectrum processing
- Digital upconversion and downconversion
- Protocol-specific processing
- Pulse detection and classification
- Low-latency RF control loops
- Inline data reduction
- Custom modulation and demodulation
FPGA capability can require LabVIEW FPGA, model-specific instrument design libraries and specialized engineering. It should be selected when the application needs customization rather than treated as a requirement for every RF test system.
Phase-Coherent, MIMO and Multichannel RF Test
Installing several RF modules in one chassis does not automatically create a phase-coherent system. MIMO, beamforming and phased-array applications require a defined synchronization and calibration architecture.
The complete design may need:
- A common reference clock
- Shared local oscillator signals
- Matched trigger distribution
- Phase-aligned acquisition and generation
- Matched RF cables
- Channel-to-channel phase calibration
- Temperature and drift compensation
Synchronization requirements should be defined before selecting the chassis, RF instruments and cable set because they can change the complete bill of materials.
PXIe-5830 and mmWave Test Architectures
The PXIe-5830 provides two bidirectional test ports covering 5 GHz to 12 GHz with 1 GHz instantaneous bandwidth. It can serve as an IF and processing instrument within compatible microwave and mmWave test configurations.
The PXIe-5830 alone should not be assumed to provide direct access to every millimeter-wave band. A complete mmWave system may require remote frequency-conversion hardware, cables, adapters, switching, calibration accessories and model-specific configuration components.
At higher frequencies, cable loss, connector repeatability, fixture design and physical placement of frequency-conversion hardware become increasingly important.
RF Data Throughput and Streaming
Wideband instruments can generate large volumes of complex I/Q data. Approximate payload rate can be calculated as:
I/Q data rate = sample rate × bytes per complex sample × active RF channels.
A complex sample contains both in-phase and quadrature values. The transferred data representation may use more bytes than the ADC resolution alone suggests.
The complete data path includes:
- RF instrument acquisition engine
- Onboard memory and FPGA processing
- PXIe peripheral slot
- Chassis PCIe switch and segment
- Controller or remote connection
- System memory
- Storage or network destination
- RF analysis software
A module may capture a finite record at full bandwidth into onboard memory even when the complete system cannot continuously stream that data rate. Finite acquisition, real-time processing and sustained recording are different operating requirements.
PXIe Chassis and Controller Requirements
RF systems can use multiple chassis slots and require significant power, cooling and PCIe bandwidth. Some RF instruments are complete single modules, while others are systems composed of multiple modules and interconnecting cables.
Verify:
- PXIe slot type and lane configuration
- Number of required chassis slots
- Chassis-segment bandwidth
- Controller connection and memory performance
- Per-slot and total cooling capacity
- Required reference clocks and trigger routes
- Placement of related RF modules
- Front-panel cable clearance
Physical slot availability does not guarantee sufficient bandwidth, cooling or synchronization support.
RF Cables, Connectors and Signal Path
RF cables and accessories are part of the measurement system. Each component introduces insertion loss, mismatch, phase delay and frequency-dependent behavior.
A complete RF path may include:
- Coaxial cables
- RF adapters
- Fixed or programmable attenuators
- Amplifiers and preamplifiers
- Directional couplers
- Power splitters and combiners
- Filters
- RF switches
- Fixture and probe interfaces
Confirm the connector series, frequency rating, loss, return loss, phase stability, power handling and cable length. Connecting incompatible connector families can damage precision RF interfaces even when they appear mechanically similar.
RF Switching and Multi-DUT Testing
RF switching allows one analyzer or generator to serve multiple DUTs or test ports. This can improve production-system utilization and reduce the number of RF instruments required.
The switch path must be evaluated for:
- Operating frequency
- Insertion loss
- Return loss
- Изоляция
- Power handling
- Switching repeatability
- Topology and port count
- Switching speed and relay life
Loss and mismatch through the switch, fixture and cables should be characterized or de-embedded where required by the measurement method.
Software and RF Measurement Applications
| Software | Primary Function | Compatibility to Confirm |
|---|---|---|
| NI-RFSA | Controls supported RF signal analyzers and acquires I/Q data | Analyzer model, operating system and driver version |
| NI-RFSG | Controls supported RF signal generators and generated waveforms | Generator model, waveform format and driver version |
| RFmx | Provides spectrum, modulation and standards-based RF measurements | Required measurement personality, license and hardware support |
| InstrumentStudio | Interactive instrument configuration and supported RF measurements | Instrument and software-version compatibility |
| ЛабВью | Automated RF applications, data processing and system integration | LabVIEW, driver and operating-system versions |
| LabVIEW FPGA | Custom real-time processing on supported FPGA-enabled instruments | FPGA target, instrument design library and required licenses |
| Тестовая стойка | Production-test sequencing, limits and result handling | Adapter, driver and application-code compatibility |
RFmx measurement personalities are licensed according to the required functionality. Do not assume that purchasing an RF module automatically includes every cellular, WLAN, Bluetooth or spectrum-analysis measurement package.
Calibration, De-Embedding and Measurement Uncertainty
RF measurement results can be affected by instrument accuracy, cables, adapters, switching, fixture loss, impedance mismatch, temperature and calibration method. The reference plane should be defined before evaluating the uncertainty budget.
A complete RF accuracy plan may include:
- Instrument amplitude and frequency accuracy
- Generator level accuracy
- Cable and adapter loss
- Switch-path insertion loss
- Mismatch uncertainty
- Fixture characterization
- Phase and group-delay error
- Path-loss correction or de-embedding
- Calibration interval and traceability
Self-calibration and external calibration perform different functions. System-level path correction may still be required after an instrument has received external calibration.
Типичные применения
- RFIC characterization and semiconductor production test
- Power amplifier and front-end module testing
- Wireless transmitter and receiver validation
- Cellular, WLAN and Bluetooth testing
- 5G and next-generation wireless research
- Radar waveform generation and analysis
- Electronic warfare and spectrum monitoring
- Satellite and aerospace communication testing
- Filter, mixer and amplifier characterization
- MIMO, beamforming and phased-array validation
- Automated RF production test
- Custom FPGA-based RF processing
Legacy PXI RF Instrument Replacement
Replacing an older RF instrument can affect calibration, cabling, software, measurement limits and correlation with historical production data. A newer model with wider bandwidth may not be a direct substitute.
Compare the following before approving a replacement:
- Generation, analysis or transceiver architecture
- Minimum and maximum frequency
- Instantaneous bandwidth
- Input and output power ranges
- Dynamic range, noise floor and phase noise
- Modulation and EVM performance
- RF connector type and cable configuration
- Trigger, reference-clock and synchronization support
- Chassis slots, bandwidth, power and cooling
- NI-RFSA, NI-RFSG and RFmx compatibility
- Measurement API and existing test code
- Calibration procedure and test-limit correlation
Validated production systems may require software modification and measurement requalification before a newer RF instrument can replace the original hardware.
PXI RF and Wireless Test Procurement Guide
Provide the following information for model selection and quotation:
- Exact NI model and part number if known
- Signal generation, analysis or transceiver requirement
- Minimum and maximum RF frequency
- Required instantaneous bandwidth
- RF input and output power ranges
- Required noise floor, dynamic range or phase noise
- Modulation format or wireless standard
- EVM and other measurement-performance requirements
- Number of transmit and receive channels
- Phase-coherent, MIMO or beamforming requirements
- Finite capture, real-time processing or continuous streaming
- Existing PXIe chassis and controller models
- Required cables, adapters, switches and frequency extensions
- Operating system and NI software versions
- Required RFmx measurement personalities
- Calibration and traceability requirements
- Required quantity, product condition and destination
For pre-owned RF hardware, request device-recognition, self-test and functional measurement results. Confirm that all required system modules, interconnecting cables and accessory kits are included where the RF instrument uses a multicomponent architecture.
Часто задаваемые вопросы
What is the difference between frequency range and instantaneous bandwidth?
Frequency range defines where the instrument can tune. Instantaneous bandwidth defines how much spectrum it can generate or analyze at one time without retuning.
What is a PXI Vector Signal Transceiver?
A VST combines vector signal generation, vector signal analysis and FPGA-based processing in a software-defined PXI instrument. It can provide stimulus and measurement functions within one integrated architecture.
Should I choose a VST or separate VSA and VSG modules?
Choose according to the required frequency coverage, bandwidth, performance, channel count, existing system and automation strategy. A VST provides integrated operation, while separate instruments may suit systems requiring independent analyzer and generator configurations.
What is the difference between the PXIe-5654 and PXIe-5841?
The PXIe-5654 is primarily an analog RF and microwave signal generator for CW and supported analog-modulation applications. The PXIe-5841 is a vector signal transceiver that integrates wideband modulated-signal generation, analysis and FPGA processing.
What is the PXIe-5668 used for?
The PXIe-5668 is a wideband vector signal analyzer for spectrum, modulation, transmitter, radar and other RF-analysis applications. Different configurations provide frequency coverage up to 14 GHz or 26.5 GHz.
Does the PXIe-5830 directly cover every mmWave frequency?
No. The PXIe-5830 provides 5 GHz to 12 GHz test ports and can operate within compatible mmWave architectures. Direct testing of higher mmWave bands can require remote frequency-conversion hardware and additional accessories.
Can multiple PXI RF instruments be phase coherent?
Yes, when the selected hardware supports the required clock, local oscillator, trigger and calibration architecture. Installing modules in one chassis alone does not guarantee phase coherence.
Can PXI RF data be streamed continuously?
It depends on I/Q sample rate, data format, channel count, FPGA processing, chassis bandwidth, controller performance and storage. Finite full-bandwidth acquisition does not automatically guarantee continuous streaming at the same rate.
Does RFmx come with every PXI RF module?
Not necessarily. RFmx measurement personalities and standards-based analysis functions may require separate licenses. Verify the exact software package and version required by the application.
Why are RF cables and adapters important?
RF interconnects introduce loss, mismatch and phase delay. Incorrect connector type, inadequate frequency rating or excessive cable loss can materially reduce measurement accuracy and may damage precision RF connectors.
Recommended PXI RF and Wireless Test Products
Consider the PXIe-5654 for analog RF and microwave stimulus, the PXIe-5668 for wideband vector signal analysis, the PXIe-5830 for 5 GHz to 12 GHz wideband transceiver applications, or the PXIe-5841 for integrated RF generation, analysis and FPGA processing.
Related NI PXI Solutions
Browse additional PXI and PXIe modules for complete automated test systems. Use PXI signal generators for non-RF waveform stimulus or review PXI oscilloscopes and digitizers for high-speed time-domain acquisition.
NI PXI RF and Wireless Test Solutions from PXISOURCE
PXISOURCE supports engineers, system integrators and procurement teams with PXI RF instrument selection, frequency and bandwidth review, chassis and controller compatibility, software verification, RF accessory matching and legacy-system replacement. Send the RF frequency range, bandwidth, signal level, modulation standard, channel quantity and existing system configuration for a technically matched quotation.
Need help selecting an NI PXI RF and wireless test solution? Email sales@pxisource.com or contact PXISOURCE on WhatsApp.