PCI-6233

  • The displayed price is sourced from the official manufacturer’s website for reference only.
  • For project pricing, bulk discounts, and procurement support, please contact our sales team.

NI PCI-6233, 16-Bit, 250 kS/s, 16 AI, 24 V DIO Sinking, Bank-Isolated, PCI Multifunction I/O Device

Please enable JavaScript in your browser to complete this form.
Target price, estimated delivery time or remarks...
Category:
12 People watching this product now!

National Instruments PCI-6233 16-Bit Isolated Voltage Input and Output DAQ Device

PCI-6233 Isolated Multifunction Data Acquisition Device

The PCI-6233 is an isolated M Series multifunction data acquisition board for industrial monitoring, control and automated testing. It provides 16 single-ended or eight differential voltage inputs, two voltage outputs, industrial digital I/O and two 32-bit counters/timers.

The analog inputs support four software-selectable ranges and aggregate sampling rates up to 250 kS/s. Bank isolation separates the field-side analog and digital circuitry from the computer bus, helping protect the computer and reduce problems caused by ground-potential differences.

Key Features of the PCI-6233

  • 16 single-ended or eight differential voltage inputs
  • 16-bit analog input resolution
  • 250 kS/s maximum aggregate analog input rate
  • ±0.2 V, ±1 V, ±5 V and ±10 V input ranges
  • Two 16-bit ±10 V analog outputs
  • 500 kS/s maximum single-channel output rate
  • Six industrial digital input lines
  • Four sinking digital output lines
  • 0 V to 30 V digital input range
  • Up to 350 mA on one digital output line
  • Two 32-bit counters/timers
  • Voltage input/output bank isolation
  • 37-pin D-Sub connectivity
  • NI-DAQmx support

PCI-6233 Technical Specifications

Product ModelPCI-6233
Product SeriesIsolated M Series DAQ
Bus InterfacePCI
Analog Inputs16 single-ended or 8 differential voltage channels
ADC Resolution16 bits
Maximum Input Sample Rate250 kS/s aggregate
Input Ranges±0.2 V, ±1 V, ±5 V and ±10 V
Input Bandwidth700 kHz typical
Analog Outputs2 voltage output channels
DAC Resolution16 bits
Output Range±10 V
Maximum Output Rate500 kS/s on one channel; 450 kS/s/ch using two
Digital Inputs6 fixed-direction industrial inputs
Digital Outputs4 fixed-direction sinking outputs
Digital Input Range0 V to 30 V
Maximum Digital Supply30 VDC
Counters/Timers2 × 32-bit
IsolationAnalog and industrial digital I/O bank isolation
I/O Connector37-pin D-Sub
Calibration Interval1 year
Operating Temperature0°C to 55°C

PCI-6233 Part Number and Accessories

ItemPart NumberDescription
PCI-6233779619-01Isolated voltage-input and voltage-output PCI DAQ device
37-Pin D-Sub CableConfiguration dependentConnects the PCI-6233 to a terminal accessory or fixture
37-Pin Terminal BlockConfiguration dependentProvides screw-terminal access to analog and digital signals
External Digital SupplyUser suppliedPowers the sinking digital output circuit within its rating
RTSI CableConfiguration dependentSynchronizes the board with other compatible PCI devices

The PCI-6233 uses isolated field-side circuitry, but its channels are organized into banks rather than providing independent channel-to-channel isolation. Review the isolation diagram before combining signals from unrelated electrical systems.

Isolated Voltage Acquisition

The analog input bank accepts voltage signals from ±0.2 V through ±10 V. Differential measurement can help reject common-mode noise and is generally preferred when measuring remote or noisy signal sources.

The isolation barrier separates the measurement circuitry from the computer bus. Voltage across the isolation barrier must remain within the specified 30 Vrms or 60 VDC continuous Measurement Category I rating.

Two Programmable Voltage Outputs

Two 16-bit analog outputs generate signals across a ±10 V range. They can provide setpoints, stimuli and simulated sensor signals for compatible high-impedance loads.

The outputs provide ±5 mA drive and should not be used to directly power high-current actuators. External power amplification is required for larger loads.

Industrial Digital Input and Sinking Output

Six inputs accept industrial logic signals from 0 V to 30 V. Four outputs use a sinking architecture and require a correctly connected external supply and load.

Each sinking output supports 100 mA when all four lines operate simultaneously, while a single active line can handle up to 350 mA under the specified conditions.

PCI-6233 Applications

  • Industrial voltage monitoring
  • Automated functional testing
  • Process-control systems
  • Sensor and transmitter acquisition
  • PLC signal simulation
  • Industrial digital control
  • Production test fixtures
  • Motor and actuator monitoring
  • Ground-loop reduction
  • Data logging
  • Hardware-in-the-loop testing
  • Legacy PCI system maintenance

Industrial Control and Monitoring

The board can acquire conditioned voltage signals, generate analog control setpoints and interact with 24 V industrial status and control circuits.

Production Functional Testing

Analog outputs can stimulate a DUT while analog inputs measure its response. Industrial digital lines can operate fixture relays and monitor interlock signals.

PCI-6233 Installation Workflow

Step 1: Verify the PCI Slot

Confirm that the target computer provides a compatible conventional PCI slot and supports the required NI-DAQmx version.

Step 2: Install the Device

Power down the computer, install the PCI-6233 and secure the bracket before connecting any external signals.

Step 3: Connect the Terminal Accessory

Attach a compatible 37-pin D-Sub cable and terminal block. Verify every signal against the PCI-6233 pinout.

Step 4: Design the Isolation Boundaries

Determine which signals share AI GND, AO GND, digital ground and the computer-side isolation boundary.

Step 5: Configure NI-DAQmx

Use NI MAX to self-test the board and create analog input, analog output and digital channel configurations.

Step 6: Test with Known Signals

Validate voltage acquisition and output operation at low levels before connecting industrial equipment.

Step 7: Connect the Industrial Digital Supply

Wire the sinking output supply and loads with correct polarity, voltage and current protection.

PCI-6233 Troubleshooting

The analog inputs show incorrect values

Check single-ended or differential configuration, signal reference, input range and bank grounding. Confirm that the isolation limit is not being exceeded.

The analog output cannot drive the load

The output current is limited to approximately ±5 mA. Use a buffer or amplifier for lower-impedance and higher-current loads.

A sinking digital output does not activate

Check the external supply, load wiring and output-ground connection. A sinking output cannot provide load current without a suitable external circuit.

The card is not detected

Reseat the device, check the PCI slot and reinstall a supported NI-DAQmx version.

Noise increases when industrial equipment starts

Review cable shielding, field grounding, isolation-bank connections and routing near motor or inverter conductors.

PCI-6233 Comparison

ModelPrimary ConfigurationBest Suited For
PCI-623316 voltage AI, 2 voltage AO, industrial digital I/OIsolated voltage measurement and control
PCI-6232Isolated voltage input without analog outputVoltage acquisition-only applications
PCI-62364 current AI, 4 voltage AOCurrent-loop inputs with voltage control outputs
PCI-62398 current AI, 2 current AOExpanded 0–20 mA and ±20 mA process interfaces

Recommended Related Products

Frequently Asked Questions

What is the PCI-6233?

The PCI-6233 is an isolated M Series PCI DAQ board with voltage inputs, voltage outputs, industrial digital I/O and counters.

How many analog inputs does it provide?

It supports 16 single-ended or eight differential voltage-input channels.

What is the analog output range?

Both 16-bit analog outputs provide a ±10 V range.

Are the digital outputs sourcing or sinking?

The four industrial outputs are sinking outputs and require an external field supply.

What is the PCI-6233 part number?

The standard ordering part number is 779619-01.

Request a Quote for the PCI-6233

Contact us for current availability and pricing for the PCI-6233 Isolated Multifunction DAQ Device. We can also help identify compatible D-Sub cables, terminal blocks and replacement isolated DAQ hardware.

Part Number(s): 779619-01

Specifications

Brand

National Instruments

Related Products

Recently Viewed

Frequently Asked Questions

Yes. We can provide new and original products sourced through reliable supply channels. Depending on availability and customer requirements, selected models may also be available in used or refurbished condition. Please confirm the required condition when requesting a quotation.

Please contact us with the required model number, quantity, and application requirements. We provide competitive quotations and project-based pricing according to your purchasing needs.

Stock availability changes regularly. Some models are available for immediate shipment, while others require factory ordering or sourcing. Contact us with the exact model and part number for the latest availability.

Yes, we provide worldwide shipping solutions for customers in different countries and regions. We can arrange reliable logistics services based on your destination and delivery requirements.

Yes, our technical team can help verify specifications, system compatibility, accessories, and product selection based on your application requirements.