National Instruments SWB-2815 4×86 Reed Relay Matrix Module for SwitchBlock

SWB-2815 4 × 86 Reed Matrix for NI SwitchBlock

The NI SWB-2815 is a 1-wire, 4 × 86 reed relay matrix card for NI SwitchBlock systems. It provides 344 crosspoints for routing shared instruments, sources, and DUT nodes under software control. Its high column density is intended for automated test systems that need four common signal paths connected to a large number of test points.

The module supports up to 100 V CAT I switching, 0.25 A switching current, 0.3 A carry current, and 3 W switching power per channel. It is designed for high-density signal routing rather than high-power switching. The SWB-2815 requires an NI PXI-2800 SwitchBlock carrier and cannot operate as a standalone PXI module.

Key Features of the SWB-2815

  • 1-wire 4 × 86 reed relay matrix with 344 crosspoints
  • 0.25 A maximum switching current per channel
  • 0.3 A maximum carry current per channel
  • 100 V CAT I row/column-to-ground rating
  • 3 W maximum switching power per channel and per crosspoint
  • Initial DC path resistance below 1 Ω
  • Typical bandwidth of at least 6 MHz at -3 dB with 50 Ω termination
  • Typical thermal EMF below 50 μV
  • Four analog-bus connections for SwitchBlock expansion
  • 96-position plastic SCSI I/O connector

SWB-2815 Technical Specifications

ПараметрСпецификация
Topology1-wire 4 × 86 matrix
Crosspoints344
Тип релеNon-latching reed relay
Relay Contact MaterialRuthenium
Maximum Switching Voltage100 VDC / 70 VAC row-to-column; 100 V CAT I row/column-to-ground
Maximum Switching Current0.25 A per channel
Maximum Carry Current0.3 A per channel
Maximum Switching Power3 W per channel; 3 W per crosspoint
DC Path ResistanceInitial <1 Ω; end-of-life ≥2 Ω
Open-Channel Resistance>1 × 109 Ω
Thermal EMF, Typical<50 μV
Bandwidth, Typical≥6 MHz at -3 dB, 50 Ω termination
Analog BusFour lines: AB<0..3>
Simultaneous Drive Limit61 relays, subject to overall carrier limits
Relay Operation / Release Time, TypicalUp to 8 relays: <1 ms; up to 50 relays: <2 ms
Power Consumption63 mW per energized relay
Power Dissipation Limit3.9 W per card and carrier
Operating Temperatureот 0 °C до 55 °C
Dimensions11.2 cm × 1.2 cm × 17.1 cm
Weight320 g

The SWB-2815 is a high-density matrix, not a higher-power alternative to the SWB-2810. Its 4 × 86 topology doubles the number of columns, but its 0.25 A switching-current and 3 W switching-power limits must be checked against the intended source and DUT load.

SWB-2815 Part Number and Accessories

ItemPart NumberSelection Note
NI 2815A / SWB-2815 Type A781420-15Provides row and column access; one Type A card is used per SwitchBlock system.
NI 2815B / SWB-2815 Type B781421-15Expansion card for larger SwitchBlock matrix configurations.
NI PXI-2800Configuration dependentRequired SwitchBlock carrier for installation in a PXI chassis.
SH96F-96M-NI SwitchBlock Cable150275-01Compatible standard cable; available in 0.5 m, 1 m, and 1.5 m lengths.
SH96F-96M-RES Cable150579-01Compatible cable with 100 Ω series resistance for applicable protection requirements.
NI TBX-2809781420-09Compatible unshielded screw-terminal accessory.

SWB-2815 Matrix Architecture and Selection

4 × 86 High-Density Topology

The SWB-2815 provides four rows and 86 columns. It is suitable when a limited number of shared instruments or signal paths must be routed to a large number of DUT nodes. Typical uses include routing a DMM, power supply, signal source, or fixture interface across many points in an automated functional-test system.

A fully populated SwitchBlock carrier with six SWB-2815 cards can create a 4 × 516 matrix. With NI 2806 expansion bridges, multiple carriers can be combined into larger matrix systems. Select the expansion architecture from the required number of rows, columns, simultaneous connections, and total load budget.

Type A and Type B Card Selection

The NI 2815A and NI 2815B use the same 4 × 86 electrical topology. The Type A version provides row and column access to the SwitchBlock analog bus, while the Type B version is used for expansion. A complete SwitchBlock system can contain only one Type A module.

Relay Drive and Load Budget

Each energized SWB-2815 relay consumes 63 mW. NI specifies a 3.9 W power-dissipation limit for the card and carrier, with a simultaneous drive limit of 61 relays. A dense matrix does not mean that all crosspoints can be closed simultaneously; calculate relay-drive power across the complete carrier before running the final switching sequence.

Reed Relay Lifetime and Signal Protection

Relay life depends on the real switched load, including voltage, current, DUT capacitance, cable capacitance, and inductive behavior. NI specifies electrical life up to 1 × 109 operations at 5 V and 10 mA, 4 × 106 operations at 10 V and 100 mA, and 5 × 105 operations at 100 V and 10 mA with a resistive load below 10 pF.

Capacitive loads can cause damaging inrush current and inductive loads can generate flyback voltage. Evaluate the complete fixture and cable assembly, then use appropriate suppression or series resistance when required. The optional SH96F-96M-RES cable provides 100 Ω series resistance where that resistance is acceptable for the routed signal.

Safety and Operating Boundary

The SWB-2815 is rated for Measurement Category I only and must not be connected to mains circuits or Category II, III, or IV measurements. In a mixed-card SwitchBlock system, the lowest applicable voltage rating governs the connected system. When hazardous voltage is present, follow NI’s system safety requirements before connecting low-voltage channels.

SWB-2815 Applications

High-Density Functional Test

The SWB-2815 is suitable for production fixtures that need to route a small number of common instrument paths to many DUT test points. Its 86-column topology can reduce manual repatching in electronic assembly, PCB, and connector test systems.

Instrument Multiplexing

Engineers can route compatible DMM, low-power source, waveform-generator, or oscilloscope paths to selected DUT nodes under software control. Confirm the actual source voltage, current, bandwidth, and load type before using the matrix in the final test sequence.

Scalable SwitchBlock Systems

Multiple SWB-2815 modules can be combined in a PXI-2800 carrier or expanded across carriers where additional column capacity is required. This is useful when the application needs a structured high-density matrix rather than several independent switch modules.

SWB-2815 Comparison

SWB-2815 vs SWB-2810

Земля NI SWB-2810 provides a 4 × 43 topology with 1 A switching current, 150 V switching voltage, and 20 W switching power. Choose SWB-2815 when 86 columns are more important than power capability. Choose SWB-2810 when the application requires higher current, voltage, or switching power.

SWB-2815 vs SWB-2816

Земля NI SWB-2816 provides an 8 × 46 matrix in the same 100 V, low-current reed-matrix class. Select SWB-2815 for four rows and maximum column density; select SWB-2816 when the routing plan requires more shared instrument paths.

Recommended Related Products

  • NI PXI-2800 — required SwitchBlock carrier.
  • SH96F-96M-NI SwitchBlock Cable, 150275-01 — standard compatible cable.
  • SH96F-96M-RES Cable, 150579-01 — 100 Ω series-resistance cable for applicable load-protection designs.
  • NI TBX-2809, 781420-09 — compatible screw-terminal accessory.

Request a Quote

Contact PXISOURCE at sales@pxisource.com или WhatsApp for the NI SWB-2815. Please provide the required Type A or Type B version, quantity, PXI-2800 carrier requirement, cable length, terminal accessory, switching voltage, current, and load type.

Часто задаваемые вопросы

Can the SWB-2815 operate directly in a PXI chassis?

No. The SWB-2815 is a SwitchBlock matrix card and requires an NI PXI-2800 carrier for operation in a PXI chassis.

What is the difference between NI 2815A and NI 2815B?

Both versions are 4 × 86 reed matrices. NI 2815A provides row and column access; NI 2815B is used for expansion. A SwitchBlock system can use only one Type A card.

Can all 344 crosspoints be energized simultaneously?

No. The SWB-2815 has a simultaneous drive limit of 61 relays and a 3.9 W card and carrier power-dissipation limit. The complete carrier configuration must be reviewed before high-density switching.

Is the SWB-2815 suitable for 1 A switching?

No. The maximum switching current is 0.25 A per channel and the maximum carry current is 0.3 A per channel. Choose the SWB-2810 when the application requires 1 A switching capability.

Can the SWB-2815 switch mains voltage?

No. The SWB-2815 is rated for Measurement Category I only and must not be connected to mains circuits or Category II, III, or IV signals.

Part Number(s): 781421-15 | 781420-15

Specifications

Number of Columns: 86
Maximum Switching Current DC: 0.25 A
Макс. коммутируемое напряжение DC: 100 В
Тип реле: геркон
Количество строк: 4
Режим (n-проводной): 1-проводной

Бренд

Национальные инструменты

Сопутствующие товары

Недавно просмотренные

Frequently Asked Questions

Yes. We can provide new and original products sourced through reliable supply channels. Depending on availability and customer requirements, selected models may also be available in used or refurbished condition. Please confirm the required condition when requesting a quotation.

Please contact us with the required model number, quantity, and application requirements. We provide competitive quotations and project-based pricing according to your purchasing needs.

Stock availability changes regularly. Some models are available for immediate shipment, while others require factory ordering or sourcing. Contact us with the exact model and part number for the latest availability.

Yes, we provide worldwide shipping solutions for customers in different countries and regions. We can arrange reliable logistics services based on your destination and delivery requirements.

Yes, our technical team can help verify specifications, system compatibility, accessories, and product selection based on your application requirements.