PXI-8433/4

  • The displayed price is sourced from the official manufacturer’s website for reference only.
  • For project pricing, bulk discounts, and procurement support, please contact our sales team.

NI PXI-8433/4, 4-Port, Isolated, RS485/RS422 PXI Serial Interface Module

Для заполнения данной формы включите JavaScript в браузере.
Target price, estimated delivery time or remarks...
Категория:
10 Людей, которые сейчас смотрят этот товар!

National Instruments PXI-8433/4 4-Port Isolated RS485/RS422 Interface

PXI-8433/4 4-Port Isolated RS485/RS422 Interface

Земля PXI-8433/4 is a four-port isolated RS485 and RS422 serial interface module for PXI systems. It is designed for high-speed, long-distance and electrically robust communication with industrial devices, controllers and distributed instrumentation.

Each port supports communication rates up to 3 Mbps and provides isolation from the host system and other serial ports. The RS485/RS422 architecture offers differential signaling with better noise immunity than conventional single-ended RS232 communication.

Key Features of the PXI-8433/4

  • Four independent isolated serial ports
  • RS485 and RS422 communication support
  • Maximum transfer rate up to 3 Mbps
  • Port-to-port electrical isolation
  • Port-to-computer isolation
  • 128-byte transmit and receive FIFOs
  • DMA-based serial data transfers
  • Four 10-position modular connectors
  • Supports two-wire and four-wire communication modes
  • Suitable for multipoint RS485 networks
  • Standard COM-port and NI-VISA access
  • NI-Serial software support

PXI-8433/4 Technical Specifications

Product ModelPXI-8433/4
Part Number779539-01
Product TypeIsolated PXI serial interface
Supported StandardsRS485 and RS422
Number of Ports4
Maximum Baud Rate3 Mbps
FIFO Size128 байт
Isolation TypePort-to-port and port-to-host isolation
Communication ModesRS422 full duplex and RS485 two-wire or four-wire operation
Front Connectors4 × 10-position modular jacks
RS422 Output Voltage RangeApproximately ±7 V maximum range
RS485 Common-Mode RangeApproximately -7 V to +12 V
Operating Temperature0°C to 55°C
Storage Temperature-20°C to 70°C
Dimensions100 mm × 160 mm, 3U
Module WidthOne PXI slot

PXI-8433/4 Part Number and Accessories

ItemPart NumberОписание
PXI-8433/4779539-01Four-port isolated RS485/RS422 PXI interface
10P10C Serial CableVerify pinout and termination when orderingConnects an individual modular port to the RS485 or RS422 network

RS422 Full-Duplex Communication

RS422 normally uses separate differential pairs for transmitting and receiving data. This full-duplex arrangement allows simultaneous communication in both directions between the PXI module and a compatible device.

RS422 is commonly used for point-to-point or multidrop communication where greater cable length and noise immunity are required.

RS485 Multipoint Networks

RS485 supports multiple transceivers on a shared differential bus. The PXI-8433/4 can be used as the master or another participating device in compatible two-wire or four-wire networks.

Correct termination and biasing are critical. Termination resistors are normally installed at the physical ends of the bus rather than at every node.

Isolation for Industrial Installations

Each PXI-8433/4 port is isolated from the host and other ports. This helps protect communication when devices are distributed across different cabinets, grounding systems or power domains.

Isolation also helps prevent a problem on one serial network from disrupting other networks connected to the module.

3 Mbps Maximum Baud Rate

The module supports communication rates up to 3 Mbps. Maximum usable cable length normally decreases as the baud rate increases.

Cable impedance, termination, topology, stub length and connected transceivers must all be considered when designing a high-speed RS485 network.

Typical PXI-8433/4 Applications

  • Industrial RS485 networks
  • RS422 instrument communication
  • PLC and motion-control systems
  • Distributed sensor networks
  • Automotive controller testing
  • Aerospace and defense test systems
  • Manufacturing automation
  • Environmental test equipment
  • Multi-drop serial communication
  • Long-distance device control

NI-Serial and NI-VISA Integration

NI-Serial presents the four interfaces as standard COM ports. Application software can configure the transceiver mode, baud rate, character format and flow-control behavior.

NI-VISA enables common serial read-and-write functions from LabVIEW, LabWindows/CVI and other supported development environments.

PXI-8433/4 Troubleshooting

No device responds on an RS485 network

Check A/B polarity, termination, biasing and two-wire versus four-wire mode. Different manufacturers may label differential conductors differently.

Only the nearest device communicates

Inspect bus topology, termination placement and cable continuity. Long stubs and star wiring can produce reflections at higher baud rates.

Communication works at low speed only

Reduce cable length, improve termination and use twisted-pair cable with the correct impedance. Check the response time of every connected device.

Received data is echoed unexpectedly

Review the selected transceiver mode and application settings. Some two-wire RS485 configurations can receive the data being transmitted.

One network interferes with another

Verify the isolation and wiring for each port. Ensure that shields, references and cable drains have not created an unintended connection between networks.

PXI-8433/4 vs PXI-8432/4

ФункцияPXI-8433/4PXI-8432/4
Serial StandardRS485 and RS422RS232
Ports4 isolated ports4 isolated ports
Maximum Baud Rate3 Mbps1 Mbps
SignalingDifferentialSingle-ended
Best Suited ForLong-distance and multipoint networksConventional point-to-point RS232 devices

Recommended Related Products

Frequently Asked Questions

What is the PXI-8433/4?

It is a four-port isolated RS485 and RS422 serial interface for PXI systems.

What is its maximum baud rate?

The maximum supported communication rate is 3 Mbps.

Can it communicate with multiple RS485 devices?

Yes. It can be used in correctly designed multipoint RS485 networks.

Does it support RS422?

Yes. It supports differential RS422 communication as well as RS485 modes.

Does it provide port-to-port isolation?

Yes. Each serial port is isolated from the computer interface and the other ports.

What is the PXI-8433/4 part number?

The NI ordering part number is 779539-01.

Request a Quote for the PXI-8433/4

Contact us for availability and project pricing for the PXI-8433/4 4-Port Isolated RS485/RS422 Interface. We can also help confirm compatible cables, termination requirements and alternative NI serial modules.

Part Number(s): 779539-01

Specifications

Бренд

Национальные инструменты

Сопутствующие товары

Недавно просмотренные

Frequently Asked Questions

Yes. We can provide new and original products sourced through reliable supply channels. Depending on availability and customer requirements, selected models may also be available in used or refurbished condition. Please confirm the required condition when requesting a quotation.

Please contact us with the required model number, quantity, and application requirements. We provide competitive quotations and project-based pricing according to your purchasing needs.

Stock availability changes regularly. Some models are available for immediate shipment, while others require factory ordering or sourcing. Contact us with the exact model and part number for the latest availability.

Yes, we provide worldwide shipping solutions for customers in different countries and regions. We can arrange reliable logistics services based on your destination and delivery requirements.

Yes, our technical team can help verify specifications, system compatibility, accessories, and product selection based on your application requirements.