PXI-6224

  • The displayed price is sourced from the official manufacturer’s website for reference only.
  • For project pricing, bulk discounts, and procurement support, please contact our sales team.

NI PXI-6224, 32 AI (16-Bit, 250 kS/s), 48 DIO, PXI Multifunction I/O Module

Для заполнения данной формы включите JavaScript в браузере.
Target price, estimated delivery time or remarks...
Категория:
15 Людей, которые сейчас смотрят этот товар!

National Instruments PXI-6224 Multifunction I/O Module, 32 AI, 16-Bit, 250 kS/s, 48 DIO PXI Data Acquisition

Product Introduction

Земля NI PXI-6224 is a multifunction PXI data acquisition (DAQ) module designed for general-purpose measurement, automated testing, laboratory research, data logging, and industrial monitoring applications.

The PXI-6224 provides 32 single-ended or 16 differential analog input channels, 16-bit analog input resolution, and a maximum analog input sampling rate of 250 kS/s. It also includes 48 digital I/O lines и two 32-bit counter/timers for digital control, timing, frequency measurement, pulse generation, and automated test applications.

As part of the NI M Series multifunction DAQ family, the PXI-6224 provides a practical combination of channel count, measurement resolution, digital I/O, timing, triggering, and PXI system integration for applications that do not require analog output functionality.

Product Overview

Земля National Instruments PXI-6224 is designed for applications requiring multiple analog input channels together with extensive digital I/O and counter/timer functionality.

Its analog input subsystem provides up to 32 single-ended or 16 differential channels with 16-bit resolution. The module uses a multiplexed analog input architecture with an aggregate sampling rate of up to 250 kS/s.

Unlike M Series models that include analog outputs, the PXI-6224 focuses on analog acquisition and digital control. This makes it a suitable choice for monitoring, data logging, sensor acquisition, test fixture control, and automated measurement systems where analog signal generation is not required.

Key Features

32 Analog Input Channels

The PXI-6224 provides a high analog input channel count for general-purpose measurement applications.

  • 32 single-ended analog input channels
  • 16 differential analog input channels
  • 16-bit analog input resolution
  • Multiplexed acquisition architecture
  • Hardware-timed acquisition
  • Multi-channel voltage measurement

Advantage: The high channel count allows engineers to monitor multiple analog signals with a single PXI module, reducing the number of DAQ devices required in a test system.

16-Bit Analog Input Resolution

The PXI-6224 uses 16-bit analog-to-digital conversion for general-purpose voltage measurements.

  • 16-bit ADC resolution
  • 65,536 theoretical quantization levels
  • Accurate voltage acquisition
  • Sensor signal measurement
  • Laboratory and production testing

Advantage: 16-bit resolution provides a useful balance between measurement resolution, acquisition speed, channel count, and system cost.

250 kS/s Analog Input Sampling

The analog input subsystem provides a maximum aggregate sampling rate of 250 kS/s.

  • Up to 250 kS/s analog input sampling
  • Hardware-timed acquisition
  • Continuous data acquisition
  • Buffered measurements
  • Multi-channel scanning

Advantage: The PXI-6224 provides sufficient acquisition performance for many general-purpose automated test, monitoring, and data logging applications.

Multiplexed Analog Input Architecture

The PXI-6224 uses a multiplexed analog input architecture in which multiple input channels share the analog-to-digital conversion subsystem.

This architecture provides a relatively high analog input channel count within one PXI slot and is particularly suitable for applications where true simultaneous sampling between channels is not required.

  • High analog input channel density
  • Efficient general-purpose DAQ architecture
  • Suitable for monitoring and data logging
  • Ideal for sequential multi-channel measurements

48 Digital I/O Lines

The PXI-6224 provides 48 digital I/O lines for device control, status monitoring, and automated test applications.

  • 48 digital I/O lines
  • Digital input operation
  • Digital output operation
  • Test fixture control
  • Logic-state monitoring
  • Automated sequencing

Advantage: Extensive digital I/O allows the module to monitor switches, control relays, interface with digital devices, and coordinate external test hardware.

Correlated Digital I/O

The PXI-6224 supports correlated digital I/O for hardware-timed digital operations.

  • Hardware-timed digital acquisition
  • Hardware-timed digital generation
  • Digital waveform operations
  • Synchronization with analog measurements
  • Mixed-signal automated testing

Advantage: Correlated digital I/O enables digital events to be synchronized with analog acquisition and other hardware-timed operations.

Two 32-Bit Counter/Timers

The PXI-6224 includes two general-purpose 32-bit counter/timers for timing and pulse-related measurements.

  • 2 × 32-bit counter/timers
  • Frequency measurement
  • Period measurement
  • Pulse-width measurement
  • Подсчет событий
  • Генерация импульсов
  • Encoder measurements

Advantage: Integrated counters provide useful timing and measurement capabilities without requiring a separate counter/timer module.

Hardware Triggering

The PXI-6224 provides hardware triggering capabilities for event-driven and synchronized measurements.

  • Digital triggering
  • Analog triggering
  • Start triggering
  • Reference triggering
  • Event-based acquisition
  • PXI system synchronization

PXI Timing and Synchronization

The PXI-6224 can use PXI timing and trigger resources to coordinate measurements with other instruments in a modular test system.

  • PXI trigger bus integration
  • Multi-instrument synchronization
  • Hardware event routing
  • Automated test coordination
  • Modular system expansion

Advantage: PXI synchronization makes the PXI-6224 suitable for test systems combining DAQ, switching, oscilloscopes, digital instruments, and other measurement hardware.

NI-DAQmx Software Support

The PXI-6224 is supported by NI-DAQmx for configuration, analog acquisition, digital I/O, counters, timing, and triggering.

  • NI-DAQmx driver
  • Интеграция LabVIEW
  • NI MAX configuration
  • TestStand integration
  • C/C++ APIs
  • .NET application development

Technical Specifications

ПараметрОписание
Product TypePXI Multifunction I/O / Data Acquisition Module
МодельNI PXI-6224
Product FamilyNI M Series Multifunction DAQ
Шинный интерфейсPXI
Analog Inputs32 Single-Ended / 16 Differential
Analog Input Resolution16 Bit
Maximum Analog Input Sample Rate250 kS/s Aggregate
Sampling ArchitectureMultiplexed
Analog OutputsНичего
Цифровой ввод-вывод48 Lines
Correlated Digital I/OSupported
Counter/Timers2
Counter Resolution32 Bit
Hardware TriggeringSupported
DriverНИ-DAQmx
Primary ApplicationsData Acquisition, Monitoring, Data Logging, Automated Test and Laboratory Measurement

Analog Input Capabilities

The PXI-6224 provides up to 32 single-ended or 16 differential analog inputs for acquiring voltage signals from sensors, electronic circuits, test fixtures, and other devices.

Its 16-bit ADC provides 65,536 theoretical quantization levels, while the 250 kS/s aggregate sampling rate provides sufficient acquisition performance for many general-purpose measurement applications.

Because the PXI-6224 uses multiplexed acquisition, the maximum sampling rate is shared across enabled analog input channels rather than being available independently on every channel.

Single-Ended vs Differential Measurements

The PXI-6224 can be configured for different analog input connection methods depending on the application.

КонфигурацияMaximum ChannelsTypical Application
Single-Ended32Higher channel count and common-ground signals
Differential16Improved noise rejection and measurements with separate signal references

Differential measurements are often preferred in electrically noisy environments, while single-ended configurations maximize the number of available analog input channels.

Digital I/O Capabilities

The 48 digital I/O lines significantly expand the functionality of the PXI-6224 beyond basic analog acquisition.

  • Relay control
  • Switch monitoring
  • Logic-state acquisition
  • Test fixture control
  • Device sequencing
  • Digital communication experiments

Correlated digital I/O also allows selected digital operations to be hardware timed and synchronized with other measurement tasks.

Counter and Timing Capabilities

Two 32-bit counter/timers provide additional timing functionality for automated test and measurement systems.

  • Frequency measurements
  • Period measurements
  • Pulse-width measurements
  • Подсчет событий
  • Генерация импульсов
  • Encoder measurements

Software Ecosystem

The NI PXI-6224 integrates with the NI-DAQmx software ecosystem for measurement, control, timing, triggering, and automation.

  • NI-DAQmx: Provides the hardware driver and APIs for analog input, digital I/O, counters, triggering, and timing.
  • LabVIEW: Enables development of customized data acquisition, monitoring, control, and automated measurement applications.
  • NI MAX: Provides hardware discovery, device configuration, self-test, and basic measurement functionality.
  • TestStand: Allows PXI-6224 measurements and control functions to be incorporated into automated validation and production test sequences.
  • C/C++ and .NET: Support development of custom DAQ applications through compatible NI-DAQmx APIs.

Industries

  • Electronic Manufacturing
  • Industrial Measurement
  • Automated Test Equipment
  • Исследовательские лаборатории
  • Universities and Education
  • Automotive Testing
  • Product Development
  • Laboratory Automation

Applications

General-Purpose Data Acquisition

The PXI-6224 is suitable for acquiring multiple voltage signals in general-purpose measurement systems.

  • Voltage measurements
  • Multi-channel data acquisition
  • Sensor monitoring
  • Automated data collection
  • Laboratory experiments

Data Logging

The combination of 32 analog inputs and PXI system integration makes the PXI-6224 useful for multi-channel data logging.

  • Long-term signal monitoring
  • Environmental measurements
  • Machine monitoring
  • Experimental data recording
  • Process monitoring

Automated Functional Testing

Analog acquisition, extensive digital I/O, counters, and hardware triggering allow the PXI-6224 to perform multiple functions within automated test stations.

  • PCB functional testing
  • Electronic device validation
  • Automated pass/fail testing
  • Test fixture control
  • Production test systems

Design Verification

Engineers can use the PXI-6224 to monitor multiple signals during product development and design validation.

  • Prototype measurements
  • Hardware debugging
  • Электронное проектирование верификация
  • Performance monitoring
  • Automated validation

Industrial Monitoring

The PXI-6224 can acquire multiple analog and digital signals from industrial equipment when the application’s voltage, grounding, and isolation requirements are compatible with the module.

  • Machine monitoring
  • Process signal acquisition
  • Equipment status monitoring
  • Automated data logging

PXI-6224 vs Simultaneous-Sampling DAQ

ФункцияPXI-6224Simultaneous-Sampling DAQ
Analog Input ArchitectureMultiplexedSimultaneous Sampling
Maximum AI Channels32 Single-Ended / 16 DifferentialTypically Lower
Channel AcquisitionSequentialСинхронный
Primary AdvantageHigh Channel CountChannel-to-Channel Timing
Best ApplicationGeneral DAQ and MonitoringDynamic and Phase-Related Measurements

Comparison with Similar NI Multifunction I/O Modules

МодельОсновное различиеBest Application
NI PXI-6224 32 AI, 16-bit, 250 kS/s aggregate sampling and 48 DIO without analog outputs. General-purpose analog acquisition and digital control
NI PXI-6225 Higher analog input channel count for applications requiring substantially more measurement channels. High-channel-count data acquisition
NI PXI-6221 Related M Series multifunction DAQ that includes analog output functionality. General measurement and analog stimulus applications
NI PXI-6259 Higher-performance M Series module with 32 AI, faster analog acquisition and four analog outputs. Higher-speed multifunction data acquisition
NI PXI-6284 High-accuracy M Series module with 18-bit analog input resolution. Precision voltage measurements

Recommended Related Products

NI PXI-6225 Recommended when an application requires a larger number of analog input channels while remaining within the M Series DAQ platform.
NI PXI-6259 Suitable for applications requiring higher analog acquisition speed plus analog output functionality.
NI PXI-6284 High-accuracy alternative for applications where analog measurement resolution and precision are higher priorities.
NI PXI-6143 Simultaneous-sampling alternative for applications requiring precise time correlation between multiple analog input channels.

Why Choose NI PXI-6224?

  • 32 single-ended or 16 differential analog inputs
  • 16-bit analog input resolution
  • Up to 250 kS/s aggregate sampling
  • 48 digital I/O lines
  • Correlated digital I/O capability
  • 2 × 32-bit counter/timers
  • Hardware triggering
  • PXI timing and synchronization
  • NI-DAQmx software support
  • High analog input channel density
  • Suitable for general-purpose measurement
  • Ideal for data logging and monitoring
  • Useful for automated functional testing
  • Designed for modular PXI measurement systems

Frequently Asked Questions

What is the NI PXI-6224?

The NI PXI-6224 is an M Series PXI multifunction data acquisition module providing 32 single-ended or 16 differential analog inputs, 16-bit resolution, up to 250 kS/s aggregate sampling, 48 digital I/O lines, and two 32-bit counter/timers.

How many analog input channels does the PXI-6224 have?

The PXI-6224 provides up to 32 single-ended analog input channels or 16 differential analog input channels.

What is the analog input resolution of the PXI-6224?

The PXI-6224 provides 16-bit analog input resolution.

What is the maximum sampling rate of the PXI-6224?

The PXI-6224 provides a maximum analog input sampling rate of 250 kS/s aggregate. Because it uses a multiplexed architecture, this sampling rate is shared across enabled analog input channels rather than being available independently on every channel.

Does the PXI-6224 support simultaneous sampling?

No. The PXI-6224 uses a multiplexed analog input architecture. Applications requiring true simultaneous acquisition should use an appropriate simultaneous-sampling DAQ module.

Does the PXI-6224 have analog outputs?

No. The PXI-6224 does not provide analog output channels. If analog stimulus or waveform generation is required, another M Series multifunction DAQ model with analog outputs should be considered.

How many digital I/O lines does the PXI-6224 provide?

The PXI-6224 provides 48 digital I/O lines for device control, logic monitoring, test fixture operation, and hardware-timed digital applications.

Does the PXI-6224 support correlated digital I/O?

Yes. The PXI-6224 supports correlated digital I/O, allowing hardware-timed digital operations to be synchronized with other measurement tasks.

How many counter/timers does the PXI-6224 have?

The module provides two 32-bit general-purpose counter/timers for frequency, period, pulse-width, event-counting, pulse-generation, and encoder applications.

What software supports the PXI-6224?

The PXI-6224 uses NI-DAQmx and can be integrated with compatible LabVIEW, NI MAX, TestStand, C/C++, and .NET measurement applications.

What is the difference between PXI-6224 and PXI-6225?

Both belong to the NI M Series multifunction DAQ family, but the PXI-6225 is designed for applications requiring a substantially larger analog input channel count. The PXI-6224 is suitable when 32 single-ended or 16 differential analog inputs are sufficient.

What is the difference between PXI-6224 and PXI-6259?

The PXI-6224 provides 32 analog inputs with 250 kS/s maximum aggregate acquisition and does not include analog outputs. The PXI-6259 provides the same basic 32-channel analog input count but offers substantially higher analog acquisition speed and four analog outputs, making it more suitable for higher-performance multifunction testing.

What is the difference between PXI-6224 and PXI-6284?

The PXI-6224 is a general-purpose 16-bit M Series DAQ module, while the PXI-6284 is a high-accuracy M Series module with 18-bit analog input resolution. The PXI-6224 is suitable for standard data acquisition and monitoring, while the PXI-6284 is better suited to applications where higher measurement resolution is required.

What is the difference between PXI-6224 and PXI-6143?

The PXI-6224 provides a higher analog input channel count using multiplexed acquisition. The PXI-6143 provides fewer analog input channels but uses simultaneous sampling. Choose the PXI-6224 for general-purpose high-channel-count acquisition and the PXI-6143 when channel-to-channel timing correlation is critical.

What applications are suitable for the PXI-6224?

Typical applications include general-purpose data acquisition, multi-channel voltage monitoring, data logging, laboratory experiments, automated functional testing, electronic design verification, industrial monitoring, test fixture control, and manufacturing test.

What should I check before purchasing a PXI-6224?

Before purchasing a PXI-6224, verify the exact model and part number, PXI chassis compatibility, analog input configuration, required sampling rate, connector and cabling requirements, digital I/O requirements, and NI-DAQmx software compatibility.

Заключение

Земля NI PXI-6224 Multifunction I/O Module provides 32 single-ended or 16 differential analog inputs, 16-bit resolution, up to 250 kS/s aggregate sampling, 48 digital I/O lines, two 32-bit counter/timers, correlated digital I/O, hardware triggering, and NI-DAQmx integration. Its combination of high analog input channel count and extensive digital resources makes the PXI-6224 a practical solution for general-purpose data acquisition, data logging, automated functional testing, laboratory measurement, design verification, and monitoring applications.

Part Number(s): 779114-01

Specifications

Бренд

Национальные инструменты

Сопутствующие товары

Недавно просмотренные

Frequently Asked Questions

Yes. We can provide new and original products sourced through reliable supply channels. Depending on availability and customer requirements, selected models may also be available in used or refurbished condition. Please confirm the required condition when requesting a quotation.

Please contact us with the required model number, quantity, and application requirements. We provide competitive quotations and project-based pricing according to your purchasing needs.

Stock availability changes regularly. Some models are available for immediate shipment, while others require factory ordering or sourcing. Contact us with the exact model and part number for the latest availability.

Yes, we provide worldwide shipping solutions for customers in different countries and regions. We can arrange reliable logistics services based on your destination and delivery requirements.

Yes, our technical team can help verify specifications, system compatibility, accessories, and product selection based on your application requirements.