PCIe-8431/2

  • The displayed price is sourced from the official manufacturer’s website for reference only.
  • For project pricing, bulk discounts, and procurement support, please contact our sales team.

$873.00

NI PCIe-8431/2, 2-Port, RS485/RS422 Serial Interface Device

Для заполнения данной формы включите JavaScript в браузере.
Target price, estimated delivery time or remarks...
Категория:
18 Людей, которые сейчас смотрят этот товар!

National Instruments PCIe-8431/2 2-Port RS-485/RS-422 Serial Interface Device, 3 Mb/s, PCI Express

Product Introduction

Земля NI PCIe-8431/2 высокопроизводительный 2-port RS-485/RS-422 serial interface device designed for industrial communication, automated test, instrument control, production systems, laboratory automation, and integration of serial devices.

The PCIe-8431/2 combines two independent RS-485/RS-422 serial ports with a PCI Express host interface. It supports communication rates up to 3 Mb/s and provides flexible serial communication for industrial and test applications.

With support for RS-485 and RS-422 communication, the PCIe-8431/2 is suitable for systems requiring differential signaling, reliable communication in electrically noisy environments, or longer communication distances than conventional RS-232 interfaces.

Product Overview

Земля National Instruments PCIe-8431/2 provides two serial interfaces for connecting a PCI Express computer to compatible RS-485 or RS-422 equipment.

A typical system architecture is:

Host Computer → PCI Express → PCIe-8431/2 → RS-485 / RS-422 → Instrument / Controller / DUT

The two-port configuration is particularly useful for automated test and industrial systems that require multiple serial connections without the higher channel density of 8-port or 16-port serial cards.

Key Features

Two RS-485/RS-422 Serial Ports

The PCIe-8431/2 provides two serial communication ports supporting RS-485 and RS-422.

Each port can be used to communicate with compatible industrial devices, instruments, controllers, or embedded systems.

RS-485 Communication

The PCIe-8431/2 supports RS-485 differential serial communication.

RS-485 is widely used in industrial environments because it provides good noise immunity and can support multi-device network architectures.

Typical RS-485 applications include:

  • Промышленная автоматизация
  • Управление машиной
  • Process equipment
  • Distributed sensors
  • Production equipment
  • Автоматизированные системы тестирования
  • Building automation

RS-422 Communication

The PCIe-8431/2 also supports RS-422, providing differential serial communication for compatible instruments, controllers, and industrial devices.

RS-422 is commonly used where reliable point-to-point or multidrop differential communication is required.

Up to 3 Mb/s Serial Communication

The PCIe-8431/2 supports serial communication rates up to 3 Mb/s.

This provides substantially higher potential throughput than conventional low-speed serial communication and makes the device suitable for demanding industrial and automated test applications.

2-Wire RS-485 Operation

The PCIe-8431/2 supports 2-wire RS-485 configurations.

In a typical 2-wire network, the same differential pair is shared for transmitting and receiving data, providing half-duplex communication.

4-Wire Communication

The device also supports 4-wire communication configurations using separate differential transmit and receive pairs.

This architecture can support full-duplex communication with compatible RS-485 or RS-422 equipment.

Half-Duplex and Full-Duplex Operation

Depending on the wiring and connected device, the PCIe-8431/2 can be used in both half-duplex and full-duplex serial communication systems.

This flexibility allows the same interface to support a broad range of industrial communication architectures.

PCI Express Interface

The PCIe-8431/2 installs into a compatible PCI Express expansion slot.

A typical installation is:

Industrial PC → PCI Express Slot → PCIe-8431/2 → Serial Cable → External Equipment

This internal interface architecture is particularly suitable for permanently installed test stations, industrial computers, and rackmount systems.

High-Performance Data Transfer

The PCIe-8431 family is designed for high-performance serial communication and efficient data transfer between the serial interfaces and host computer.

This architecture is useful when multiple serial channels must continuously transmit and receive data during automated testing or industrial operation.

Standard Serial Port Integration

Compatible NI serial software allows the PCIe-8431/2 ports to be accessed using standard serial communication programming methods.

This simplifies integration with existing applications designed to communicate with COM-style serial interfaces.

Technical Specifications

ПараметрСпецификация
Product TypeSerial Interface Device
МодельPCIe-8431/2
ManufacturerНациональные инструменты
Host InterfacePCI Express
Serial InterfaceRS-485 / RS-422
Number of Serial Ports2
Maximum Baud RateUp to 3 Mb/s
Communication ModesHalf-Duplex / Full-Duplex
RS-485 Wiring2-Wire / 4-Wire
SignalingDifferential
ИзоляцияNon-Isolated
Primary FunctionRS-485 / RS-422 Serial Communication
Типичные примененияIndustrial Automation, Automated Test, Instrument Control and Serial Data Communication

How Does the PCIe-8431/2 Work?

The PCIe-8431/2 provides an interface between software running on a host computer and external equipment using RS-485 or RS-422.

For transmitted data:

Application → Serial Driver → PCIe-8431/2 → RS-485 / RS-422 → External Device

For received data:

External Device → RS-485 / RS-422 → PCIe-8431/2 → Serial Driver → Application

This bidirectional communication allows the computer to configure equipment, transmit commands, collect measurements, monitor device status, and automate industrial processes.

What Is RS-485?

RS-485 is a differential serial communication standard widely used in industrial automation and control systems.

Compared with RS-232, RS-485 generally provides:

  • Better electrical noise immunity
  • Longer practical communication distances
  • Differential signaling
  • Multi-device network capability
  • Better suitability for industrial environments

These characteristics make RS-485 one of the most widely used physical-layer standards for industrial serial communication.

What Is RS-422?

RS-422 is another differential serial communication standard used in industrial, instrumentation, and control applications.

It provides separate differential signaling and is commonly used when reliable communication over longer distances or in electrically noisy environments is required.

RS-485 vs RS-422

ФункцияRS-485RS-422
SignalingDifferentialDifferential
Multi-Device NetworksWell SuitedMore Limited
2-Wire OperationCommonTypically Not Used
4-Wire OperationSupportedCommon
Noise ImmunityHighHigh
Промышленные примененияVery CommonCommon

2-Wire vs 4-Wire Communication

Функция2-Wire4-Wire
Differential Pairs12
Transmit and ReceiveShared PairSeparate Pairs
Typical ModeHalf-DuplexFull-Duplex
Wiring ComplexityLowerHigher
Simultaneous TX/RXNoДа

The appropriate wiring configuration depends on the external equipment and serial network architecture.

Two-Port Serial Architecture

The PCIe-8431/2 provides two independent serial interfaces.

Например:

Port 1 → Industrial Controller
Port 2 → Test Instrument

This allows one computer to communicate with multiple devices without requiring separate serial adapters.

Промышленная автоматизация

The PCIe-8431/2 is well suited for industrial automation applications requiring reliable differential serial communication.

Compatible equipment can include:

  • PLCs
  • Industrial controllers
  • Motor controllers
  • Sensors
  • Machine controllers
  • Process equipment
  • Industrial instruments

A typical architecture is:

Industrial PC → PCIe-8431/2 → RS-485 Network → Industrial Devices

Automated Test Applications

The PCIe-8431/2 can integrate RS-485 and RS-422 devices into automated test systems.

A complete test platform may include:

  • PCIe-8431/2 serial interface
  • DAQ devices
  • Цифровой ввод-вывод
  • Oscilloscopes or digitizers
  • Programmable power supplies
  • Electronic loads
  • Switch systems
  • DUT fixtures

Test software can coordinate serial communication with measurement and stimulus hardware to automate DUT validation.

Instrument Control

Compatible instruments with RS-485 or RS-422 interfaces can be controlled through the PCIe-8431/2.

Typical instrument-control operations include:

  • Sending configuration commands
  • Starting measurements
  • Reading measurement data
  • Monitoring equipment status
  • Changing operating parameters
  • Logging serial data

Production Test

Production test stations can use the PCIe-8431/2 to communicate with DUTs, fixtures, controllers, and test equipment through RS-485 or RS-422.

A typical sequence can include:

  1. Initialize the serial interface.
  2. Configure baud rate and communication parameters.
  3. Send initialization commands to the DUT.
  4. Perform required measurements.
  5. Read DUT response data.
  6. Compare results against test limits.
  7. Record the test result.

Serial Communication Parameters

The PCIe-8431/2 and connected equipment must use compatible serial communication settings.

Important parameters include:

  • Baud rate
  • Data bits
  • Parity
  • Stop bits
  • Flow control
  • 2-wire or 4-wire mode
  • Half-duplex or full-duplex operation
  • Termination
  • Biasing

RS-485 Network Termination

Correct termination is important for reliable RS-485 communication, especially when using higher baud rates or longer cables.

When designing the network, consider:

  • Termination resistance
  • Cable impedance
  • Network topology
  • Cable length
  • Communication speed
  • Number of connected nodes
  • Stub length

Incorrect termination can cause signal reflections, intermittent communication errors, corrupted data, or complete communication failure.

RS-485 Biasing

Some RS-485 networks require bias resistors to maintain a known bus state when no transmitter is actively driving the network.

Biasing requirements depend on the connected devices, network topology, termination configuration, and transceiver architecture.

Communication Distance

RS-485 and RS-422 can generally communicate over longer distances than conventional RS-232.

However, practical communication distance depends on:

  • Baud rate
  • Cable quality
  • Cable impedance
  • Electrical noise
  • Network topology
  • Termination
  • Connected transceivers
  • Installation environment

Higher communication rates generally require greater attention to cable quality and network design.

PCIe-8431/2 vs PCIe-8430/2

The PCIe-8431/2 and PCIe-8430/2 are both two-port PCI Express serial interfaces, but they support different electrical standards.

ФункцияPCIe-8431/2PCIe-8430/2
Serial InterfaceRS-485 / RS-422РС-232
Serial Ports22
SignalingDifferentialSingle-Ended
Maximum Baud RateUp to 3 Mb/sModel Dependent
Multi-Device NetworksWell SuitedPrimarily Point-to-Point
Industrial Noise ImmunityHigherLower
Primary ApplicationIndustrial Serial CommunicationRS-232 Instrument Control

PCIe-8431/2 vs PCIe-8431/4

ФункцияPCIe-8431/2PCIe-8431/4
Serial StandardRS-485 / RS-422RS-485 / RS-422
Serial Ports24
Maximum Baud RateUp to 3 Mb/sUp to 3 Mb/s
Host InterfacePCI ExpressPCI Express
Best ApplicationLow Port Count SystemsMedium Port Count Systems

PCIe-8431/2 vs PCIe-8431/16

Both devices belong to the same RS-485/RS-422 serial interface family. The major difference is channel density.

ФункцияPCIe-8431/2PCIe-8431/16
Serial StandardRS-485 / RS-422RS-485 / RS-422
Serial Ports216
Maximum Baud RateUp to 3 Mb/sUp to 3 Mb/s
Host InterfacePCI ExpressPCI Express
Best ApplicationTwo-Device / Low-Port SystemsHigh-Density Serial Systems

For applications requiring only one or two independent serial interfaces, the PCIe-8431/2 avoids the unnecessary channel density of a 16-port device.

PCIe-8431/2 vs Isolated RS-485 Interface

The PCIe-8431/2 is intended for applications where a standard non-isolated RS-485/RS-422 interface is appropriate.

For applications with significant ground-potential differences or where electrical isolation is required, an isolated serial interface should be considered.

Isolation can be valuable when:

  • Ground loops are possible
  • Equipment uses different ground references
  • Electrical noise is severe
  • Devices are physically distributed
  • Additional electrical protection is required

PCIe-8431/2 vs USB RS-485 Adapter

ФункцияPCIe-8431/2Typical USB RS-485 Adapter
Host ConnectionInternal PCI ExpressExternal USB
Serial Ports2Model Dependent
Maximum SpeedUp to 3 Mb/sDevice Dependent
Permanent InstallationWell SuitedApplication Dependent
Portable UseОграниченныйBetter

The PCIe-8431/2 is particularly suitable for permanently integrated industrial and automated test systems, while USB interfaces may be more convenient for temporary or portable connections.

NI-Serial Driver

The PCIe-8431/2 operates with compatible NI-Serial driver software.

The driver provides the interface between the operating system, application software, and serial hardware.

Before integrating the device into an existing system, verify compatibility between:

  • PCIe-8431/2
  • NI-Serial version
  • Operating system
  • Development environment
  • Existing application software

NI-VISA Integration

Compatible applications can use NI-VISA for serial instrument communication.

A typical VISA workflow is:

VISA Open → Configure Serial Port → VISA Write → VISA Read → VISA Close

This provides a familiar programming architecture for automated instrument-control applications.

LabVIEW Integration

The PCIe-8431/2 can be integrated into compatible ЛабВью applications for serial communication and automation.

Typical LabVIEW applications include:

  • Industrial device control
  • Automated test
  • Instrument communication
  • Serial data logging
  • Production test
  • Laboratory automation
  • Device configuration

Legacy Serial System Replacement

The PCIe-8431/2 can be used when upgrading an existing RS-485 or RS-422 test system to a computer with PCI Express expansion capability.

Before replacing another serial interface, verify:

  • RS-485 or RS-422 requirement
  • Required number of ports
  • 2-wire or 4-wire wiring
  • Half-duplex or full-duplex operation
  • Baud rate
  • Connector and pinout
  • Termination requirements
  • Biasing requirements
  • Isolation requirements
  • PCI Express slot availability
  • NI-Serial compatibility
  • Operating system
  • Existing software application

Troubleshooting RS-485/RS-422 Communication

If communication does not work correctly, check the complete serial communication path.

  1. Verify that the PCIe-8431/2 is detected by the computer.
  2. Confirm that the correct serial port is selected.
  3. Verify RS-485 or RS-422 mode.
  4. Check 2-wire or 4-wire configuration.
  5. Confirm baud rate.
  6. Verify data bits, parity, and stop bits.
  7. Check cable pinout and polarity.
  8. Verify termination.
  9. Check network biasing.
  10. Confirm the external device communication protocol.
  11. Reduce the baud rate temporarily when troubleshooting signal-integrity problems.

How to Choose an RS-485/RS-422 Interface

Before selecting the PCIe-8431/2, determine:

  • RS-485 or RS-422 requirement
  • Number of required serial ports
  • Required maximum baud rate
  • 2-wire or 4-wire configuration
  • Half-duplex or full-duplex operation
  • Communication distance
  • Network topology
  • Termination requirements
  • Biasing requirements
  • Electrical isolation requirements
  • Available PCI Express slot
  • Driver compatibility
  • Application software compatibility

Industries

  • Промышленная автоматизация
  • Automated Test
  • Electronic Manufacturing
  • Production Test
  • Process Control
  • Laboratory Automation
  • Machine Automation
  • Research and Development
  • Embedded Systems
  • Системная интеграция

Applications

Промышленная автоматизация

The PCIe-8431/2 provides RS-485 and RS-422 connectivity for industrial controllers, sensors, machines, and automation equipment.

Automated Test

The two serial interfaces can communicate with instruments, controllers, and DUTs as part of automated electronic test systems.

Instrument Control

Compatible RS-485 and RS-422 instruments can be configured, controlled, monitored, and queried through the PCIe-8431/2.

Production Test

Production test systems can use the PCIe-8431/2 to communicate with serial DUTs, fixtures, and supporting test equipment.

Serial Data Logging

The device can receive and log serial data from compatible industrial or laboratory equipment.

Legacy Equipment Integration

Existing RS-485 and RS-422 equipment can be retained when upgrading the host computer to a PCI Express-based platform.

Recommended Related Products

PCIe-8431/22-port PCI Express RS-485/RS-422 interface for industrial communication and automated test.
PCIe-8431/44-port RS-485/RS-422 serial interface for systems requiring additional communication channels.
PCIe-8431/88-port PCI Express RS-485/RS-422 interface for medium-density serial systems.
PCIe-8431/1616-port PCI Express RS-485/RS-422 interface for high-density industrial serial communication.
PCIe-8430/22-port PCI Express RS-232 interface for equipment requiring RS-232 instead of RS-485/RS-422.

Why Choose PCIe-8431/2?

  • Two independent serial ports
  • RS-485 support
  • RS-422 support
  • Up to 3 Mb/s communication
  • Differential signaling
  • 2-wire RS-485 operation
  • 4-wire communication
  • Half-duplex support
  • Full-duplex support
  • PCI Express host interface
  • NI-Serial software support
  • NI-VISA integration
  • LabVIEW compatibility
  • Suitable for industrial automation
  • Suitable for automated test
  • Suitable for instrument control
  • Suitable for production test
  • Suitable for legacy serial equipment integration

Frequently Asked Questions

What is the NI PCIe-8431/2?

The NI PCIe-8431/2 is a two-port PCI Express serial interface device designed for RS-485 and RS-422 communication in industrial, laboratory, and automated test applications.

How many serial ports does PCIe-8431/2 have?

The PCIe-8431/2 provides two independent serial communication ports.

Does PCIe-8431/2 support RS-485?

Yes. The PCIe-8431/2 supports RS-485 differential serial communication.

Does PCIe-8431/2 support RS-422?

Yes. The PCIe-8431/2 supports both RS-485 and RS-422 communication.

What is the maximum baud rate of PCIe-8431/2?

The PCIe-8431/2 supports serial communication rates up to 3 Mb/s, depending on the selected operating configuration.

Does PCIe-8431/2 support 2-wire RS-485?

Yes. The PCIe-8431/2 supports 2-wire RS-485 operation for compatible half-duplex serial networks.

Does PCIe-8431/2 support 4-wire communication?

Yes. Four-wire operation can be used for compatible full-duplex RS-485 or RS-422 communication systems.

Is PCIe-8431/2 isolated?

The PCIe-8431/2 is a non-isolated RS-485/RS-422 serial interface. Applications requiring electrical isolation should use an appropriate isolated serial interface.

What is the difference between PCIe-8431/2 and PCIe-8430/2?

The PCIe-8431/2 is designed for RS-485/RS-422, while the PCIe-8430/2 is designed for РС-232. The correct model should be selected according to the electrical serial interface used by the external equipment.

What is the difference between PCIe-8431/2 and PCIe-8431/16?

Both devices support RS-485/RS-422 communication, but the PCIe-8431/2 provides two serial ports while the PCIe-8431/16 provides sixteen. The two-port version is more appropriate when only a small number of independent serial connections are required.

Can PCIe-8431/2 be used with LabVIEW?

Yes. The PCIe-8431/2 can be integrated into compatible LabVIEW applications for industrial communication, automated test, serial data logging, and instrument control.

Can PCIe-8431/2 be used with NI-VISA?

Yes. Compatible applications can use NI-VISA to communicate with serial instruments and other devices connected through the PCIe-8431/2.

Can PCIe-8431/2 communicate with Modbus devices?

The PCIe-8431/2 provides the RS-485/RS-422 physical serial interface required by many Modbus RTU systems. Modbus communication itself must be implemented by compatible application software or a Modbus library, and the connected device’s protocol and serial settings must match.

Can PCIe-8431/2 communicate with two devices simultaneously?

Yes. Its two independent serial ports can communicate with separate compatible devices, subject to the software and communication architecture used by the application.

Why is my RS-485 device not communicating with PCIe-8431/2?

Check the RS-485 wiring polarity, 2-wire or 4-wire mode, baud rate, data bits, parity, stop bits, termination, network biasing, device address, serial protocol, and communication cable.

What should I check before purchasing PCIe-8431/2?

Verify whether the equipment uses RS-485 or RS-422, the required number of ports, maximum baud rate, 2-wire or 4-wire architecture, half-duplex or full-duplex operation, connector and cable requirements, termination, biasing, isolation requirements, PCI Express slot, NI-Serial driver, operating system, NI-VISA, LabVIEW, and existing application compatibility.

Заключение

Земля NI PCIe-8431/2 2-Port RS-485/RS-422 Serial Interface Device provides two independent differential serial communication ports through a PCI Express host interface. With communication rates up to 3 Mb/s and support for RS-485, RS-422, 2-wire, 4-wire, half-duplex, and full-duplex configurations, it is well suited for industrial automation, automated test, instrument control, production testing, serial data logging, and integration of existing RS-485/RS-422 equipment.

Part Number(s): 782124-01

Specifications

Supported Power Input: —
Bus Connection: PCI Express
Тип изоляции: Нет
Number of Serial Channels: 2
Supported Serial Protocols: RS485#RS422
Operating Temperature Range: —
Maximum Baud Rate: —
Front Connection Type: D-SUB(2)
Number of Bidirectional Digital Channels: —

Бренд

Национальные инструменты

Сопутствующие товары

Недавно просмотренные

Frequently Asked Questions

Yes. We can provide new and original products sourced through reliable supply channels. Depending on availability and customer requirements, selected models may also be available in used or refurbished condition. Please confirm the required condition when requesting a quotation.

Please contact us with the required model number, quantity, and application requirements. We provide competitive quotations and project-based pricing according to your purchasing needs.

Stock availability changes regularly. Some models are available for immediate shipment, while others require factory ordering or sourcing. Contact us with the exact model and part number for the latest availability.

Yes, we provide worldwide shipping solutions for customers in different countries and regions. We can arrange reliable logistics services based on your destination and delivery requirements.

Yes, our technical team can help verify specifications, system compatibility, accessories, and product selection based on your application requirements.