PCI-6024E 16-Channel Multifunction PCI DAQ Device
Земля NI PCI-6024E is an E Series multifunction data acquisition device designed for laboratory automation, research, design verification, manufacturing test and general-purpose voltage measurement. It combines analog input, analog output, digital I/O and counter/timer functions on one conventional PCI board.
The PCI-6024E provides 16 single-ended or eight differential analog inputs with 12-bit resolution and a maximum aggregate sampling rate of 200 kS/s. Two analog output channels can generate programmable control voltages and basic stimulus signals.
Eight digital I/O lines and two 24-bit counter/timers support fixture control, status monitoring, frequency measurement, event counting and pulse generation. Compatible SCC or SCXI signal conditioning can extend the board to sensor and higher-voltage measurements.
Key Features of the PCI-6024E
- 16 single-ended or eight differential analog inputs
- 12-bit analog input resolution
- 200 kS/s maximum aggregate sample rate
- Software-selectable bipolar input ranges
- Two analog output channels
- Eight digital I/O lines
- Two 24-bit counter/timers
- Digital triggering support
- RTSI synchronization capability
- 68-pin front-panel connector
- Conventional PCI interface
- SCC and SCXI signal-conditioning compatibility
- NI-DAQmx software support
PCI-6024E Technical Specifications
| Product Model | PCI-6024E |
|---|---|
| Common Orderable Part Number | 777743-01 |
| Product Family | NI E Series Multifunction DAQ |
| Шинный интерфейс | Conventional PCI |
| Analog Inputs | 16 single-ended or 8 differential |
| Analog Input Resolution | 12 bits |
| Maximum AI Sample Rate | 200 kS/s aggregate |
| Input Coupling | DC |
| Input Configuration | Single-ended or differential |
| Analog Outputs | 2 voltage outputs |
| Цифровой ввод-вывод | 8 lines |
| Counter/Timers | 2 × 24-bit |
| Запуск | Digital triggering |
| Синхронизация | RTSI bus |
| Front Connector | 68-pin connector |
| Power Source | PCI bus powered |
| Driver Software | NI-DAQmx and supported legacy NI software |
| Lifecycle | Legacy/discontinued product |
The PCI-6024E uses multiplexed analog input acquisition. Its 200 kS/s rate is shared across every channel included in the acquisition task rather than being available independently on each channel.
PCI-6024E Part Number and Accessories
| Item | Part Number | Описание |
|---|---|---|
| PCI-6024E | 777743-01 | 16-channel, 12-bit PCI multifunction DAQ device |
| SH68-68-EP Cable | Length dependent | Shielded 68-pin cable for E Series DAQ devices |
| SCB-68A | 782536-01 | Shielded screw-terminal connector block |
| BNC-2110 | 777643-01 | BNC accessory for analog, digital and counter signals |
| CB-68LP | 777145-01 | General-purpose 68-pin screw-terminal block |
| RTSI Cable | Configuration dependent | Shares timing and trigger signals between PCI devices |
Legacy PCI-6024E boards can carry different assembly numbers in addition to the commercial orderable part number. Confirm the complete label, connector type and hardware revision when purchasing a replacement.
12-Bit Analog Acquisition
The PCI-6024E provides 16 single-ended inputs for maximum channel count or eight differential inputs for improved common-mode noise rejection. Programmable gain allows the input range to be matched to different voltage levels.
A 12-bit converter divides the selected full-scale range into 4,096 codes. For measurements requiring finer voltage resolution, a 16-bit device such as the PCI-6014 или PCI-6221 may be more appropriate.
200 kS/s Multiplexed Sampling
The board supports an aggregate analog input rate up to 200 kS/s. If ten channels are sampled at the same rate, each channel can operate at approximately 20 kS/s before considering settling and application constraints.
High source impedance can increase settling errors after the multiplexer changes channels. Lowering the scanning rate or adding an external buffer may improve accuracy.
Two Analog Outputs
Two analog outputs can generate DC setpoints, low-frequency waveforms and DUT stimulus. These outputs are intended for compatible low-current loads.
An external power amplifier or driver is required for motors, actuators, lamps, power relays and other loads that exceed the board’s output capability.
Digital I/O and Counter Functions
Eight digital lines can monitor logic states and control test-fixture functions. Two 24-bit counters support event counting, frequency measurement, pulse-width measurement and pulse generation.
SCC and SCXI Signal Conditioning
Compatible SCC or SCXI hardware can add amplification, filtering, isolation, excitation and sensor-specific conditioning. This allows the PCI-6024E to work with thermocouples, strain gauges and industrial signals that cannot be connected directly.
NI-DAQmx Integration
NI-DAQmx provides channel configuration, timing, triggering and data-transfer functions. Because the PCI-6024E is a legacy product, confirm driver and operating-system compatibility before migrating an existing system.
PCI-6024E Applications
- Laboratory data acquisition
- Automated functional testing
- Manufacturing test
- Design verification
- OEM measurement systems
- General-purpose voltage monitoring
- Analog stimulus generation
- Digital fixture control
- Event and frequency measurement
- Sensor measurement with external conditioning
Laboratory Automation
The PCI-6024E can measure analog voltages, generate basic stimulus and monitor digital states from one software-controlled board.
Производственное тестирование
Analog inputs can verify DUT voltage levels while digital outputs control fixture functions and counters measure frequency or pulse signals.
Sensor Measurement
With suitable external conditioning, the PCI-6024E can acquire signals from temperature, force, pressure and displacement sensors.
PCI-6024E Installation Workflow
Step 1: Confirm the PCI Slot
Verify that the host computer contains an available conventional PCI slot.
Step 2: Check Software Compatibility
Confirm that the operating system and NI-DAQmx version support the PCI-6024E.
Step 3: Install the Board
Power down the computer, observe ESD precautions and secure the board in its PCI slot.
Step 4: Connect the Accessory
Install a compatible shielded 68-pin cable and terminal block using the PCI-6024E pinout.
Step 5: Test in NI MAX
Run the device self-test and verify analog input, analog output, digital and counter operation.
Step 6: Validate the Application
Confirm signal ranges, sample-rate allocation, grounding, output limits and trigger configuration.
PCI-6024E Troubleshooting
The PCI-6024E is not detected
Check PCI slot compatibility, board seating, BIOS resources and NI-DAQmx support.
The measured signal contains excessive noise
Use differential wiring, shielded cables and appropriate grounding. Keep analog signals away from high-current wiring.
The per-channel sampling rate is too low
The 200 kS/s aggregate rate is divided among the active analog input channels.
The analog output voltage decreases under load
The connected circuit may draw excessive current. Test the output with a high-impedance meter and add a buffer if required.
The counter reports false edges
Improve signal grounding and edge quality or use external Schmitt-trigger conditioning.
PCI-6024E Comparison
| Модель | AI Resolution | AI Rate | AO | Best Suited For |
|---|---|---|---|---|
| PCI-6024E | 12-bit | 200 kS/s | 2 | Legacy general-purpose E Series DAQ |
| PCI-6014 | 16-битный | 200 kS/s | 2 | Higher-resolution legacy acquisition |
| PCI-6221 | 16-битный | 250 kS/s | 2 | M Series multifunction applications |
| PCIe-6321 | 16-битный | 250 kS/s | 2 | PCI Express replacement systems |
PCI-6024E vs PCI-6014
Both models provide 16 analog inputs, two analog outputs and a 200 kS/s maximum input rate. The PCI-6014 provides 16-bit analog input resolution compared with 12-bit resolution on the PCI-6024E.
Why Choose the PCI-6024E?
Choose the PCI-6024E when maintaining an existing PCI system that depends on its E Series timing behavior, 68-pin wiring and software configuration.
PCI-6024E Frequently Asked Questions
How many analog inputs does the PCI-6024E provide?
It provides 16 single-ended or eight differential analog inputs.
What is its maximum sampling rate?
The maximum aggregate analog input rate is 200 kS/s.
Does it provide analog outputs?
Yes. The PCI-6024E includes two analog output channels.
What type of counters are included?
The board provides two 24-bit counter/timers.
Can it measure thermocouples?
Yes, when suitable external amplification, filtering and cold-junction compensation are provided.
Is the PCI-6024E suitable for PCI Express slots?
No. It is a conventional PCI board and cannot be installed directly in a PCIe-only slot.
Recommended Related Products
- PCI-6014 Multifunction DAQ Device
- PCI-6221 Multifunction DAQ Device
- PCIe-6321 Multifunction DAQ Device
- View More NI DAQ Products
Request a Quote for the PCI-6024E
Contact us for current availability and pricing for the NI PCI-6024E Multifunction DAQ Device. Include the complete part number, board revision and required connection accessories in your inquiry.