PXI-8431/8

  • The displayed price is sourced from the official manufacturer’s website for reference only.
  • For project pricing, bulk discounts, and procurement support, please contact our sales team.

NI PXI-8431/8, 8-Port, RS485/RS422 PXI Serial Interface Module

Для заполнения данной формы включите JavaScript в браузере.
Target price, estimated delivery time or remarks...
Категория:
11 Людей, которые сейчас смотрят этот товар!

National Instruments PXI-8431/8 8-Port RS-485 and RS-422 PXI Serial Module

PXI-8431/8 8-Port RS-485 and RS-422 Serial Module

Земля NI PXI-8431/8 is an eight-port, nonisolated RS-485 and RS-422 serial interface module for industrial communication, automated testing and embedded-device validation. Differential signaling provides better noise rejection and supports longer cable distances than conventional single-ended RS-232 communication.

The module supports communication rates up to 3 Mbaud in applicable RS-422 and RS-485 configurations. It also provides DMA transfers, multithreaded operation and flexible transceiver modes for communicating with point-to-point and multidrop serial networks.

Key Features of the PXI-8431/8

  • Eight independent RS-485/RS-422 ports
  • Up to 3 Mbaud serial communication
  • Two-wire and four-wire operation
  • Full-duplex and half-duplex configurations
  • Automatic transceiver control for two-wire RS-485
  • DMA-based data transfers
  • Multithreaded communication support
  • Suitable for multidrop networks
  • Nonisolated port design
  • NI-Serial and NI-VISA support
  • Compact 3U PXI form factor
  • High-density breakout connectivity

PXI-8431/8 Technical Specifications

Product ModelPXI-8431/8
Product TypeEight-port PXI serial interface
Serial StandardsRS-485 and RS-422
Number of Ports8
Port IsolationNonisolated
Maximum Baud RateUp to 3 Mbaud
Two-Wire Auto-Control RateUp to 2 Mbaud
Wiring ModesTwo-wire and four-wire
Duplex ModesHalf duplex and full duplex, configuration dependent
Network TypesPoint-to-point and multidrop
Data TransferDMA-based architecture
SoftwareNI-Serial and NI-VISA
Bus PlatformPXI
Module Format3U PXI
Front ConnectionHigh-density connector used with compatible breakout cabling

RS-485 and RS-422 Communication

RS-422 is commonly used for point-to-point or multidrop receive configurations with separate transmit and receive pairs. RS-485 adds support for shared-bus multidrop networks in which multiple transceivers can communicate over the same differential pair.

The correct operating mode depends on the connected equipment. Two-wire RS-485 normally uses a shared transmit/receive pair, while four-wire operation uses separate pairs and can support full-duplex communication.

Automatic Transceiver Control

In a two-wire RS-485 network, a transmitter must release the bus after sending data so another node can respond. Automatic transceiver control manages this direction change without requiring the application to toggle a separate control line manually.

The supported rate for two-wire auto-control operation can differ from the module’s highest general serial rate. Confirm the selected transceiver mode and baud-rate limitation during system configuration.

Differential Serial Advantages

Differential signaling improves immunity to common-mode electrical noise and is useful for factory automation, environmental chambers and distributed test equipment. Proper cable selection and termination remain essential for reliable high-speed operation.

PXI-8431/8 Part Number and Accessories

ItemОписание
PXI-8431/8Eight-port, nonisolated RS-485/RS-422 PXI module
High-Density Serial CableConnects the module to a compatible eight-port breakout assembly
RS-485/RS-422 Breakout AssemblyProvides accessible connectors for the individual serial ports
Twisted-Pair CableMaintains the differential signal path between nodes
Termination and Bias ComponentsProvide appropriate line termination and idle-bus bias when required
External IsolatorAdds galvanic isolation for installations with ground-potential differences

Select cables according to the exact PXI-8431/8 pinout. RS-232 breakout products must not be substituted simply because their connectors appear mechanically similar.

PXI-8431/8 Applications

  • Industrial controller communication
  • RS-485 multidrop networks
  • Environmental chamber control
  • Motor-drive and motion-system testing
  • Embedded-device validation
  • Автоматизация производства
  • Building-control communication
  • Modbus RTU test systems
  • Long-distance serial links
  • Multi-device production testing

Industrial Communication

The PXI-8431/8 can connect a test system to programmable logic controllers, motor drives, power meters and other industrial equipment. Protocol handling such as Modbus RTU is normally implemented by the application or an appropriate software library.

Multidrop Test Networks

Multiple addressed devices can share an RS-485 bus, reducing cable count. The system designer must manage addressing, termination, biasing, response timing and transmitter contention.

PXI-8431/8 Installation Workflow

Step 1: Install the Driver

Install a compatible NI-Serial driver and NI-VISA before configuring the hardware.

Step 2: Install the PXI Module

Power down the chassis, insert the PXI-8431/8 into an appropriate slot and secure the front panel.

Step 3: Connect the Breakout Hardware

Attach the compatible high-density cable and breakout assembly. Verify port numbering before connecting field devices.

Step 4: Select the Transceiver Mode

Configure two-wire or four-wire operation and choose the appropriate transceiver-control mode for the network.

Step 5: Wire and Terminate the Bus

Maintain signal-pair polarity, use twisted-pair cable and install termination only at the correct physical ends of the bus.

Step 6: Verify Communication

Begin at a moderate baud rate with one node, then add additional nodes after the basic command-and-response path is operating reliably.

PXI-8431/8 Troubleshooting

No devices respond

Check the TX+/TX− and RX+/RX− polarity, common reference, transceiver mode and whether the system uses two-wire or four-wire wiring.

Communication works at low speed but fails at high speed

Inspect cable impedance, termination, stub length and grounding. Long branches and incorrect termination can distort high-speed differential signals.

Only one multidrop node responds

Confirm that each node has a unique address and that no device holds the shared bus in the transmit state. Review protocol response delays and turnaround timing.

Replies are truncated in two-wire mode

Check the automatic transceiver-control configuration and timing. Ensure the remote device does not begin its response before the transmitter has released the bus.

Communication changes when other equipment is powered

The ports are nonisolated. Measure ground-potential differences and consider an externally isolated interface if the installation cannot maintain a safe common reference.

PXI-8431/8 Comparison

МодельInterfaceBest Suited For
PXI-8431/88-port RS-485/RS-422, nonisolatedHigh-density differential serial communication
PXI-8431/44-port RS-485/RS-422Smaller differential serial systems
PXI-8430/88-port RS-232Single-ended RS-232 instruments
PXI-8433/4Isolated RS-485/RS-422Four-port systems requiring galvanic isolation

PXI-8431/8 Frequently Asked Questions

How many ports does the PXI-8431/8 provide?

It provides eight independently configurable RS-485/RS-422 ports.

What is the maximum baud rate?

The module supports rates up to 3 Mbaud, while applicable two-wire automatic-control configurations support lower maximum rates.

Does it support two-wire RS-485?

Yes. It supports two-wire half-duplex and applicable automatic transceiver-control operation.

Are its ports isolated?

No. The PXI-8431/8 is a nonisolated serial interface.

Can it run Modbus RTU?

Yes, when the Modbus protocol is implemented through compatible application software or a suitable library.

Request a Quote for the PXI-8431/8

Contact us for availability and pricing for the NI PXI-8431/8 eight-port RS-485/RS-422 module. We can also identify compatible breakout cables, isolated alternatives and related PXI communication modules.

Part Number(s): 779537-01

Specifications

Бренд

Национальные инструменты

Condition

Used

Сопутствующие товары

Недавно просмотренные

Frequently Asked Questions

Yes. We can provide new and original products sourced through reliable supply channels. Depending on availability and customer requirements, selected models may also be available in used or refurbished condition. Please confirm the required condition when requesting a quotation.

Please contact us with the required model number, quantity, and application requirements. We provide competitive quotations and project-based pricing according to your purchasing needs.

Stock availability changes regularly. Some models are available for immediate shipment, while others require factory ordering or sourcing. Contact us with the exact model and part number for the latest availability.

Yes, we provide worldwide shipping solutions for customers in different countries and regions. We can arrange reliable logistics services based on your destination and delivery requirements.

Yes, our technical team can help verify specifications, system compatibility, accessories, and product selection based on your application requirements.