PCI-6013 16-Channel 16-Bit Multifunction DAQ Device
Земля NI PCI-6013 is a B Series multifunction data acquisition board designed for OEM equipment, laboratory automation, research, design verification and manufacturing test.
It provides 16 single-ended analog inputs with 16-bit resolution and a maximum aggregate sampling rate of 200 kS/s. The analog subsystem is designed for general-purpose voltage measurement and conditioned sensor acquisition.
Eight digital I/O lines and two 24-bit counter/timers provide additional monitoring, control and timing capabilities. The PCI-6013 does not include analog output channels.
Key Features of the PCI-6013
- 16 analog input channels
- 16-bit analog input resolution
- 200 kS/s maximum aggregate sampling
- Multiplexed analog input architecture
- Eight digital I/O lines
- Two 24-bit counter/timers
- Digital triggering support
- Concurrent analog, digital and counter operations
- 68-pin front-panel connector
- Conventional PCI interface
- NI-DAQmx support
- Designed for OEM and automated test systems
PCI-6013 Technical Specifications
| Product Model | PCI-6013 |
|---|---|
| Orderable Part Number | 778629-01 |
| Additional Hardware Number | 188626-02 |
| Product Family | NI B Series Multifunction DAQ |
| Шинный интерфейс | Conventional PCI |
| Analog Inputs | 16 single-ended channels |
| Analog Input Resolution | 16 bits |
| Maximum Sample Rate | 200 kS/s aggregate |
| Sampling Architecture | Multiplexed |
| Analog Outputs | Ничего |
| Цифровой ввод-вывод | 8 bidirectional lines |
| Counter/Timers | 2 × 24-bit |
| Запуск | Digital triggering |
| Front Connector | 68-pin connector |
| Driver Software | НИ-DAQmx |
| Lifecycle Status | Discontinued and no longer supported by NI |
The PCI-6013 can sustain digital and counter/timer operations while performing analog acquisition. Available PCI bus and driver resources should still be considered when several tasks run concurrently.
PCI-6013 Part Number and Accessories
| Item | Part Number | Описание |
|---|---|---|
| PCI-6013 | 778629-01 | 16-bit, 200 kS/s PCI multifunction DAQ device |
| PCI-6013 Hardware | 188626-02 | Hardware or assembly identifier associated with some units |
| Shielded 68-Pin Cable | Length dependent | Connects the PCI-6013 to a terminal accessory |
| SCB-68A | 782536-01 | Shielded screw-terminal connector block |
| BNC-2110 | 777643-01 | BNC accessory for analog and digital signal access |
| CB-68LP | 777145-01 | General-purpose screw-terminal connector block |
Confirm whether the buyer requires commercial part number 778629-01 or a specific hardware assembly number. Different board revisions may be important when replacing a device in a validated test system.
16-Bit Analog Measurement
The 16-bit converter provides 65,536 possible digital codes across the selected input range. This offers finer voltage resolution than older 12-bit multifunction DAQ boards.
Measurement accuracy also depends on calibration, signal range, source impedance, grounding, noise and the external signal path.
200 kS/s Aggregate Sampling
The maximum 200 kS/s rate is shared by the analog input channels included in the acquisition task. The required per-channel rate should be calculated according to the number of active channels.
Because the channels are multiplexed, they are sampled sequentially rather than simultaneously. Phase-sensitive measurements may require a simultaneous-sampling device.
Eight Digital I/O Lines
Eight digital lines can monitor logic conditions or control compatible external devices. External drivers are required for relays, solenoids and higher-current loads.
Two 24-Bit Counter/Timers
The counter/timers support event counting, frequency measurement, pulse-width measurement and pulse generation. Input signals must have clean transitions and compatible logic levels.
NI-DAQmx Software
NI-DAQmx provides hardware configuration and measurement APIs. However, the PCI-6013 is discontinued, so operating-system and driver compatibility must be verified before changing the host computer.
PCI-6013 Applications
- OEM measurement equipment
- Laboratory data acquisition
- Manufacturing test
- Design verification
- General-purpose voltage monitoring
- Conditioned sensor acquisition
- Digital status monitoring
- Fixture control
- Frequency and event measurement
OEM Measurement Systems
The PCI-6013 provides analog, digital and counter resources for dedicated measurement equipment built around a desktop or industrial computer.
Manufacturing Test
The analog inputs can verify DUT voltage levels while digital lines and counters monitor production fixture and timing signals.
Long-Term Data Logging
The device can record moderate-bandwidth voltage and conditioned sensor signals. Application software should monitor disk space, buffer status and acquisition errors.
PCI-6013 Installation Workflow
Step 1: Verify the Host Computer
Confirm that the computer provides an available conventional PCI slot.
Step 2: Check Driver Compatibility
Verify that the planned operating system and NI-DAQmx version support the discontinued PCI-6013.
Step 3: Install the Board
Power down the computer, observe ESD precautions and install the card securely.
Step 4: Connect the Terminal Accessory
Install a compatible shielded 68-pin cable and verify the PCI-6013 pinout.
Step 5: Run NI MAX Diagnostics
Perform a device self-test and acquire a known voltage using a test panel.
Step 6: Validate the DAQ Task
Confirm channel ranges, sampling rate, grounding, digital directions and counter terminals.
PCI-6013 Troubleshooting
The device does not appear in NI MAX
Check PCI slot compatibility, board seating and whether the NI-DAQmx version supports the PCI-6013.
The input readings are unstable
Review grounding, shielding, signal-source impedance and nearby interference sources.
The acquisition is slower than expected
The 200 kS/s rate is an aggregate value shared by all active channels.
A digital output cannot drive a relay
Install an external transistor, relay driver or isolated digital interface.
The replacement board behaves differently
Compare the orderable part number, assembly number, revision, calibration status and software configuration.
PCI-6013 Comparison
| Модель | AI | Разрешение | AO | Primary Difference |
|---|---|---|---|---|
| PCI-6013 | 16 | 16-битный | 0 | Input-focused B Series DAQ |
| PCI-6014 | 16 | 16-битный | 2 | Adds analog outputs |
| PCI-6024E | 16 | 12-bit | 2 | Lower input resolution |
| PCI-6220 | 16 | 16-битный | 0 | M Series with additional digital resources |
PCI-6013 vs PCI-6014
The two boards provide similar 16-bit, 200 kS/s analog input functionality. The PCI-6014 adds two analog output channels, while the PCI-6013 is focused on acquisition.
PCI-6013 vs PCI-6220
The PCI-6220 provides a newer M Series architecture, a 250 kS/s sample rate, 24 digital I/O lines and 32-bit counters. Migration requires connector, software and timing verification.
Why Choose the PCI-6013?
Choose the PCI-6013 when maintaining a validated legacy system that requires the same B Series architecture, PCI interface and existing fixture wiring.
PCI-6013 Frequently Asked Questions
What is the PCI-6013 part number?
The commercial orderable part number is 778629-01. Some units may also reference hardware number 188626-02.
How many analog inputs are provided?
The PCI-6013 provides 16 analog input channels.
Does it include analog outputs?
No. The PCI-6014 is a related model with two analog outputs.
What is the maximum sample rate?
The maximum aggregate analog input rate is 200 kS/s.
Is the PCI-6013 discontinued?
Yes. NI lists the product as discontinued and no longer supported.
What should be checked when buying a replacement?
Verify the part number, assembly revision, connector, calibration condition and driver compatibility.
Recommended Related Products
- PCI-6014 Multifunction DAQ Device
- PCI-6024E Multifunction DAQ Device
- PCI-6220 Multifunction DAQ Device
- PCIe-6320 Multifunction DAQ Device
Request a Quote for the PCI-6013
Contact us for availability and pricing for the NI PCI-6013 Multifunction DAQ Device. Please provide the complete part number and board revision so that we can verify compatibility.