National Instruments PXI-8432/2 2-Port Isolated RS232 Serial Interface

PXI-8432/2 2-Port Isolated RS232 Serial Interface

Земля PXI-8432/2 is a two-port isolated RS232 interface for PXI systems. Unlike nonisolated RS232 modules, it provides electrical isolation between the serial ports and the host system as well as port-to-port isolation.

This design helps protect the PXI system from ground-potential differences, common-mode noise and unintended current paths. It is suitable for industrial equipment, remote instruments and test installations where the connected devices do not share a clean common ground.

Key Features of the PXI-8432/2

  • Two independent isolated RS232 ports
  • 2,000 V isolation architecture
  • Port-to-port and port-to-host isolation
  • Maximum baud rate up to 1 Mbps
  • 128-byte transmit and receive FIFOs
  • High-performance DMA transfers
  • Two front-panel DB9 male connectors
  • Standard COM-port compatibility
  • NI-Serial and NI-VISA software support
  • Suitable for noisy industrial environments
  • Compact one-slot 3U PXI format

PXI-8432/2 Technical Specifications

Product ModelPXI-8432/2
Part Number779743-01
Product TypeIsolated PXI serial interface
Serial StandardRS232
Number of Ports2
Maximum Baud Rate1 Mbps
FIFO Size128 байт
Isolation TypePort-to-port and port-to-computer isolation
Рейтинг изоляции2,000 V isolation class
Front Connectors2 × DB9 male
Typical +5 V CurrentApproximately 725 mA
Maximum +5 V CurrentApproximately 1 A
Operating Temperature0°C to 55°C
Storage Temperature-20°C to 70°C
Dimensions100 mm × 160 mm, 3U
WeightApproximately 125 g

PXI-8432/2 Part Number and Cabling

ItemPart NumberОписание
PXI-8432/2779743-01Two-port isolated RS232 PXI interface
DB9 RS232 CableApplication dependentStraight-through or null-modem cable selected according to DTE/DCE wiring

Port-to-Port Isolation

Each serial channel is isolated from the other port. A ground difference or electrical disturbance on one connected device is therefore less likely to interfere with the second serial link.

Isolation does not eliminate the need to remain within the specified working-voltage and safety limits. It should not be treated as approval for connecting arbitrary hazardous circuits.

Direct DB9 Connectivity

The PXI-8432/2 provides two DB9 male connectors directly on the front panel. This simplifies integration with standard RS232 cables and avoids the separate breakout cable required by higher-port-count modules.

Confirm whether the attached device is configured as DTE or DCE. A null-modem cable may be necessary when both ends use the same interface arrangement.

Industrial Communication Applications

The isolated architecture is useful for equipment installed in test cells, production lines or separate electrical cabinets. It can reduce communication problems caused by ground loops between the PXI chassis and remote equipment.

Typical devices include PLC programming interfaces, motor controllers, environmental chambers, industrial sensors and legacy manufacturing equipment.

Typical PXI-8432/2 Applications

  • Isolated industrial RS232 communication
  • PLC and motion-controller interfaces
  • Environmental test systems
  • Remote serial instrument control
  • Production equipment integration
  • Ground-loop reduction
  • High-voltage test-system support
  • Laboratory automation

NI-Serial and NI-VISA Support

NI-Serial installs the hardware and presents both channels as standard COM ports. NI-VISA can provide resource-based communication from LabVIEW and other supported programming environments.

Applications can independently configure the baud rate, character format, flow control and timeout for each channel.

PXI-8432/2 Troubleshooting

The connected device does not respond

Check whether a straight-through or null-modem cable is required. Then confirm the baud rate, parity, data bits, stop bits and flow control.

The port works at low speed but not at 1 Mbps

Verify that the connected device supports the selected rate. Inspect cable length, shielding, grounding and connector quality.

The module is detected but no COM ports appear

Repair or reinstall NI-Serial and check Device Manager for disabled devices or resource conflicts.

Isolation does not solve the communication problem

Measure the ground-potential difference and verify that it remains within the module’s working limits. Also check cable routing and electromagnetic interference.

PXI-8432/2 vs PXI-8430/2

ФункцияPXI-8432/2PXI-8430/2
Ports2 RS2322 RS232
ИзоляцияPort-to-port and port-to-hostNonisolated
Maximum Baud Rate1 Mbps1 Mbps
Best Suited ForNoisy or separated electrical systemsDevices sharing a suitable common ground

Recommended Related Products

Frequently Asked Questions

What is the PXI-8432/2?

It is a two-port isolated RS232 serial interface module for PXI systems.

Does it provide port-to-port isolation?

Yes. Its two serial ports are isolated from each other and from the computer interface.

Which connectors are provided?

The module has two front-panel DB9 male connectors.

What is its maximum baud rate?

The maximum supported transfer rate is 1 Mbps.

What is the PXI-8432/2 part number?

The NI ordering part number is 779743-01.

Request a Quote for the PXI-8432/2

Contact us for pricing and availability for the PXI-8432/2 Isolated RS232 Interface. We can also help identify compatible cables and isolated RS485/RS422 alternatives.

Part Number(s): 779743-01

Specifications

Сопутствующие товары

Недавно просмотренные

Frequently Asked Questions

Yes. We can provide new and original products sourced through reliable supply channels. Depending on availability and customer requirements, selected models may also be available in used or refurbished condition. Please confirm the required condition when requesting a quotation.

Please contact us with the required model number, quantity, and application requirements. We provide competitive quotations and project-based pricing according to your purchasing needs.

Stock availability changes regularly. Some models are available for immediate shipment, while others require factory ordering or sourcing. Contact us with the exact model and part number for the latest availability.

Yes, we provide worldwide shipping solutions for customers in different countries and regions. We can arrange reliable logistics services based on your destination and delivery requirements.

Yes, our technical team can help verify specifications, system compatibility, accessories, and product selection based on your application requirements.