PCI-6236

  • The displayed price is sourced from the official manufacturer’s website for reference only.
  • For project pricing, bulk discounts, and procurement support, please contact our sales team.

NI PCI-6236, 16-Bit, 250 kS/s, 4 Analog Inputs (±20 mA), Bank Isolation PCI Multifunction I/O Device

Для заполнения данной формы включите JavaScript в браузере.
Target price, estimated delivery time or remarks...
Категория:
15 Людей, которые сейчас смотрят этот товар!

National Instruments PCI-6236 4-Channel Isolated Current Input Multifunction DAQ

PCI-6236 Isolated Current-Input Multifunction DAQ Device

Земля PCI-6236 is an isolated M Series multifunction data acquisition board designed for industrial current-loop measurement and voltage-based control. It provides four differential ±20 mA analog inputs and four 16-bit ±10 V analog outputs.

The board also includes six digital inputs, four digital outputs, two 32-bit counters and hardware triggering. Bank isolation helps separate field-side signals from the computer bus and reduces problems caused by differences in electrical ground potential.

Key Features of the PCI-6236

  • Four differential current-input channels
  • ±20 mA input range
  • 16-bit analog input resolution
  • 250 kS/s aggregate input sampling
  • Four 16-bit voltage outputs
  • ±10 V analog output range
  • Up to 500 kS/s on one analog output
  • Six fixed-direction digital inputs
  • Four fixed-direction digital outputs
  • Two 32-bit counters/timers
  • Bank-isolated analog and digital architecture
  • 700 kHz analog input bandwidth
  • 37-pin D-Sub connectivity
  • NI-DAQmx software support

PCI-6236 Technical Specifications

Product ModelPCI-6236
Product SeriesIsolated M Series DAQ
Шинный интерфейсPCI
Analog Inputs4 differential current inputs
Input Range±20 мА
ADC Resolution16 bits
Maximum Input Sample Rate250 kS/s aggregate
Input Impedance92 Ω typical in parallel with 100 pF
Input Bandwidth700 kHz
Overcurrent Limit±40 mA maximum
Analog Outputs4 voltage outputs
DAC Resolution16 bits
Analog Output Range±10 V
Maximum Output Rate500 kS/s using one channel; 400 kS/s/ch using four
Output Drive±5 mA
Digital Inputs6
Digital Outputs4
Counters/Timers2 × 32-bit
I/O Connector37-pin D-Sub
Calibration Interval1 year
Operating Temperature0°C to 55°C

PCI-6236 Part Number and Accessories

ItemPart NumberОписание
PCI-6236779621-01Four-channel isolated current-input PCI multifunction DAQ
SH37F-37M CableLength dependentShielded 37-pin D-Sub DAQ cable
37-Pin Terminal BlockConfiguration dependentProvides field-wiring access to the card signals
Loop Power SupplyUser suppliedPowers two-wire current transmitters when required
RTSI CableConfiguration dependentRoutes synchronization signals between PCI devices

Current-loop transmitters may be active or loop powered. Determine the transmitter type before wiring the PCI-6236, and never allow the current to exceed the specified ±40 mA protection limit.

Direct ±20 mA Current Measurement

The four inputs measure current directly without requiring an external shunt resistor. Their differential configuration is suited to common industrial transmitter and process-loop signals.

When measuring a conventional 4–20 mA transmitter, the application can convert the measured current into pressure, flow, level, temperature or another engineering unit.

Four Voltage Output Channels

The four ±10 V outputs can generate programmable control references, actuator commands and simulated sensor signals. Maximum output drive is approximately ±5 mA, so high-current loads require external buffering.

Bank Isolation

Isolation separates the field-side I/O subsystem from the PCI computer bus. It does not mean that every input channel is isolated from every other channel. All common references and isolation groups must be reviewed during system design.

PCI-6236 Applications

  • 4–20 mA process monitoring
  • Industrial transmitter acquisition
  • Process-control system testing
  • Управление клапаном и приводом
  • PLC and controller simulation
  • Automated production testing
  • Industrial data logging
  • Sensor calibration systems
  • Hardware-in-the-loop testing
  • Ground-loop reduction
  • Research and laboratory automation
  • Legacy PCI control-system maintenance

Process Transmitter Monitoring

The current inputs can acquire four industrial transmitters directly. Software can apply scaling equations and alarms according to each transmitter’s 4–20 mA measurement range.

Controller and PLC Testing

Voltage outputs can simulate analog signals while digital and counter functions reproduce status and timing events. This supports automated testing of industrial controllers and input modules.

PCI-6236 Installation Workflow

Step 1: Verify the PCI Computer

Confirm availability of a conventional PCI slot and a supported operating system and NI-DAQmx combination.

Step 2: Install the PCI-6236

Shut down the computer, insert the card and secure the bracket.

Step 3: Connect the D-Sub Accessory

Use a compatible shielded 37-pin cable and terminal block. Confirm the current-input polarity and ground references.

Step 4: Wire the Current Loops

Determine whether each transmitter provides its own loop power or requires an external supply. Add appropriate fusing and current limitation.

Step 5: Configure NI-DAQmx

Create current-input channels with the ±20 mA range and voltage-output channels with the required limits.

Step 6: Validate with a Calibrator

Apply known current levels such as 4 mA, 12 mA and 20 mA and confirm the resulting software scaling.

Step 7: Test the Outputs

Measure the analog outputs with a high-impedance meter before connecting them to the final load.

PCI-6236 Troubleshooting

A current input always reads zero

Check loop continuity, transmitter polarity and loop power. A two-wire transmitter requires a suitable external supply.

The current reading is lower than expected

Check the total loop resistance, supply voltage and transmitter compliance voltage. Inspect wiring for unintended parallel current paths.

An analog output cannot reach the programmed voltage

The load may require more than the available ±5 mA drive. Disconnect the load and test with a high-impedance meter.

The card reports an overrange condition

Confirm that the current remains within ±20 mA for normal measurement. Currents beyond ±40 mA can permanently damage the input circuitry.

Measurements contain industrial noise

Use twisted shielded wiring, separate signal cables from motor drives and verify the isolation and grounding arrangement.

PCI-6236 Comparison

МодельAnalog ConfigurationBest Suited For
PCI-62364 current AI and 4 voltage AOCurrent acquisition with voltage control
PCI-62388 current AI without analog outputsHigher-density current acquisition
PCI-62398 current AI and 2 current AOCurrent-loop measurement and generation
PCI-623316 voltage AI and 2 voltage AOIsolated voltage-based systems

Recommended Related Products

Frequently Asked Questions

What does the PCI-6236 measure?

It provides four differential current inputs with a fixed ±20 mA measurement range.

Does the PCI-6236 provide current outputs?

No. Its four analog outputs generate ±10 V voltage signals. Select the PCI-6239 when current output is required.

Can it measure a 4–20 mA transmitter directly?

Yes, provided the loop is wired and powered correctly and remains within the device’s electrical limits.

How many counters does it provide?

The PCI-6236 includes two 32-bit general-purpose counters/timers.

What is the PCI-6236 part number?

The standard ordering part number is 779621-01.

Request a Quote for the PCI-6236

Contact us for current availability and project pricing for the PCI-6236 Isolated Current-Input Multifunction DAQ Device. We can also help select cables, terminal blocks and suitable current-loop DAQ alternatives.

Part Number(s): 779621-01

Specifications

Бренд

Национальные инструменты

Сопутствующие товары

Недавно просмотренные

Frequently Asked Questions

Yes. We can provide new and original products sourced through reliable supply channels. Depending on availability and customer requirements, selected models may also be available in used or refurbished condition. Please confirm the required condition when requesting a quotation.

Please contact us with the required model number, quantity, and application requirements. We provide competitive quotations and project-based pricing according to your purchasing needs.

Stock availability changes regularly. Some models are available for immediate shipment, while others require factory ordering or sourcing. Contact us with the exact model and part number for the latest availability.

Yes, we provide worldwide shipping solutions for customers in different countries and regions. We can arrange reliable logistics services based on your destination and delivery requirements.

Yes, our technical team can help verify specifications, system compatibility, accessories, and product selection based on your application requirements.