National Instruments PCI-6281 Multifunction PCI DAQ Board with 18-Bit Resolution and 625 kS/s Sampling

Product Introduction

Земля NI PCI-6281 is a high-accuracy M Series multifunction data acquisition (DAQ) device designed for PCI-based measurement and automated test systems. It combines high-resolution analog input, analog output, digital I/O, counters/timers, and hardware triggering on a single multifunction DAQ board.

The PCI-6281 provides up to 16 single-ended or 8 differential analog input channels с 18-bit resolution, making it particularly suitable for applications where measurement accuracy and resolution are more important than extremely high acquisition speed.

In addition to analog input, the PCI-6281 provides 2 analog output channels, 24 digital I/O lines, and two 32-bit counters/timers. This multifunction architecture allows engineers to perform measurement, generation, digital control, event counting, and timing functions with a single PCI DAQ device.

Typical applications include laboratory automation, research, design validation, electronic testing, manufacturing test, sensor measurement, data logging, process monitoring, and automated test equipment.

Product Overview

Земля National Instruments PCI-6281 belongs to the high-accuracy NI M Series multifunction DAQ family.

A typical measurement architecture is:

Sensors / Voltage Signals → Signal Conditioning → PCI-6281 → PCI Bus → Host Computer → NI-DAQmx / LabVIEW

The PCI-6281 integrates multiple measurement and control functions into a single device, reducing the number of separate interface cards required in a PC-based test system.

Key Features

18-Bit Analog Input Resolution

One of the most important characteristics of the PCI-6281 is its 18-bit analog input resolution.

The higher ADC resolution provides finer measurement granularity than conventional 16-bit multifunction DAQ devices, making the PCI-6281 suitable for precision voltage measurements and sensor acquisition applications.

Up to 625 kS/s Analog Input

The PCI-6281 provides high-resolution analog acquisition with sampling performance up to 625 kS/s.

This combination of resolution and acquisition speed makes the device suitable for precision measurement applications that require significantly more performance than low-speed monitoring hardware.

16 Single-Ended Analog Inputs

The PCI-6281 provides up to 16 single-ended analog input channels.

This configuration is useful when a test system must acquire multiple voltage or conditioned sensor signals using a common measurement architecture.

8 Differential Analog Inputs

The analog input channels can also be configured for up to 8 differential measurements.

Differential measurement can provide improved rejection of common-mode noise and is often preferred for precision measurements, remote sensors, and electrically noisy environments.

2 Analog Output Channels

The PCI-6281 provides two analog output channels for generating programmable voltage signals.

Analog outputs can be used for:

  • Device excitation
  • Control signals
  • Test stimulus generation
  • Setpoint generation
  • Closed-loop test applications
  • Automated device validation

24 Digital I/O Lines

The PCI-6281 includes 24 digital I/O lines for interfacing with digital devices and control signals.

Digital I/O can be used for:

  • Device control
  • Status monitoring
  • Relay control
  • Digital triggering
  • Logic-state monitoring
  • Automated test sequencing

Two 32-Bit Counters/Timers

The PCI-6281 provides two 32-bit counters/timers for timing and event-based measurement applications.

Counter/timer applications can include:

  • Подсчет событий
  • Frequency measurement
  • Period measurement
  • Pulse-width measurement
  • Encoder measurement
  • Генерация импульсов
  • Digital timing

Analog and Digital Triggering

The PCI-6281 supports hardware triggering capabilities for synchronized and event-driven acquisition.

Triggering allows measurements to begin or respond according to defined analog or digital events rather than relying exclusively on software timing.

PCI Interface

The PCI-6281 installs directly into a compatible PCI slot in a desktop, industrial, or rackmount computer.

It is particularly useful for maintaining and expanding existing PCI-based automated test and measurement systems.

NI-DAQmx Support

The PCI-6281 is supported through the NI-DAQmx measurement architecture, providing configuration, acquisition, generation, timing, triggering, and programming functionality.

The device can be integrated into applications developed with LabVIEW and other compatible programming environments.

Technical Specifications

ПараметрСпецификация
Product TypeM Series Multifunction DAQ Device
МодельPCI-6281
ManufacturerНациональные инструменты
Шинный интерфейсPCI
Analog Input Resolution18-Bit
Maximum Analog Input Sample RateUp to 625 kS/s
Maximum Single-Ended Analog Inputs16
Maximum Differential Analog Inputs8
Analog Output Channels2
Цифровой ввод-вывод24 Lines
Counters/Timers2
Counter Resolution32-Bit
ЗапускAnalog and Digital
I/O Connector68-Pin VHDCI
DriverНИ-DAQmx
Product FamilyNI M Series DAQ
Primary FunctionPrecision Multifunction Data Acquisition

How Does the PCI-6281 Work?

The PCI-6281 acquires analog signals from sensors, transducers, test points, and other voltage sources and converts them into digital measurement data using its high-resolution analog-to-digital converter.

A simplified acquisition path is:

Analog Signal → Input Circuitry → Multiplexer → 18-Bit ADC → PCI-6281 → PCI Bus → Host Application

The same device also provides analog output, digital I/O, counters/timers, and triggering resources, allowing measurement and control operations to be coordinated within one DAQ system.

High-Accuracy Data Acquisition

The PCI-6281 is particularly useful when measurement accuracy and resolution are major system requirements.

Its 18-bit analog input architecture provides finer voltage measurement resolution than lower-resolution multifunction DAQ hardware.

Типичные применения включают:

  • Precision voltage measurement
  • Sensor characterization
  • Electronic device validation
  • Laboratory measurement
  • Research experiments
  • Automated data logging

Sensor Measurement

The PCI-6281 can acquire signals from sensors that provide compatible voltage outputs or from sensors connected through appropriate signal-conditioning hardware.

Applications can include:

  • Pressure measurement
  • Force measurement
  • Position measurement
  • Temperature measurement with appropriate conditioning
  • Voltage monitoring
  • Process sensor acquisition

Always verify sensor output range, grounding, signal conditioning, excitation, and input protection requirements before connecting a sensor directly to the DAQ device.

Laboratory Automation

The PCI-6281 combines analog measurement, waveform generation, digital control, and timing functions in one PCI device.

This makes it suitable for automated laboratory systems where a computer must simultaneously acquire sensor data and control external equipment.

Design Verification and Electronic Test

The PCI-6281 can be used for electronic design verification and functional testing where multiple voltages, control signals, and timing events must be measured or generated.

Типичные применения включают:

  • Voltage monitoring
  • Device characterization
  • Functional validation
  • Power-supply monitoring
  • Control-signal generation
  • Automated pass/fail testing

Manufacturing Test

Manufacturing test systems can use the PCI-6281 for automated acquisition and control operations.

A typical production test sequence can:

  1. Configure analog and digital channels.
  2. Generate the required test stimulus.
  3. Control the device under test.
  4. Acquire voltage measurements.
  5. Measure timing or frequency signals.
  6. Evaluate pass/fail limits.
  7. Store the test results.

Analog Input Configuration

The PCI-6281 supports multiple analog input connection configurations according to the measurement architecture.

The appropriate configuration depends on:

  • Signal source type
  • Grounding
  • Noise environment
  • Required channel count
  • Common-mode voltage
  • Measurement accuracy requirements

Single-Ended Measurements

Single-ended configuration provides the maximum analog input channel count and can be appropriate for short connections and properly grounded signal sources.

Differential Measurements

Differential configuration measures the voltage difference between two input terminals and can provide better common-mode noise rejection.

For precision or electrically noisy applications, differential measurement is often preferred when the reduced channel count is acceptable.

Analog Output Applications

The two analog outputs allow the PCI-6281 to generate programmable voltage signals while simultaneously performing other measurement and control operations.

Typical analog output applications include:

  • Device stimulus
  • Voltage setpoints
  • Control-system references
  • Automated test excitation
  • Waveform generation

Digital I/O Applications

The 24 digital I/O lines can be incorporated into test and automation systems for controlling or monitoring digital signals.

Типичные применения включают:

  • Relay control
  • Switch control
  • Device status monitoring
  • Digital handshaking
  • Trigger generation
  • Pass/fail indicators

Counter and Timer Applications

The PCI-6281 provides two 32-bit counters/timers for hardware-timed digital measurements and generation.

Counter functions can support applications involving:

  • Frequency
  • Period
  • Pulse width
  • Подсчет событий
  • Encoder signals
  • Pulse trains
  • Digital timing

Hardware Triggering

Hardware triggering is important when acquisition must begin in response to a specific electrical event.

The PCI-6281 can participate in triggered measurement architectures for applications such as:

  • Transient capture
  • Automated device testing
  • Event-based data acquisition
  • Synchronized measurements
  • Repeatable laboratory experiments

PCI-6281 vs PXI-6281

The PCI-6281 and PXI-6281 provide closely related M Series multifunction DAQ capabilities but use different system platforms.

ФункцияPCI-6281PXI-6281
PlatformPCIPXI
Analog Input Resolution18-Bit18-Bit
Analog Input Channels16 SE / 8 Differential16 SE / 8 Differential
Analog Output Channels22
Цифровой ввод-вывод2424
Counters/Timers22
InstallationDesktop / Industrial PCPXI Шасси
Best ApplicationPC-Based DAQModular PXI Test Systems

PCI-6281 vs USB-6281

The PCI-6281 and USB-6281 belong to the same high-accuracy M Series DAQ family but use different host interfaces.

ФункцияPCI-6281USB-6281
Host InterfacePCIUSB 2.0
Analog Input Resolution18-Bit18-Bit
Maximum Single-Ended AI1616
Maximum Differential AI88
Цифровой ввод-вывод2424
Counters/Timers22
InstallationInternal PC CardExternal USB Device
Best ApplicationPermanent PC-Based SystemsPortable / External DAQ Systems

PCI-6281 vs PCI-6280

The PCI-6281 and PCI-6280 are both high-accuracy M Series DAQ devices. The PCI-6281 adds analog output capability, making it better suited to applications requiring both acquisition and analog signal generation.

ФункцияPCI-6281PCI-6280
Analog Input Resolution18-Bit18-Bit
Analog InputДаДа
Analog Output2 ChannelsNo
Цифровой ввод-вывод2424
Counters/Timers22
Primary AdvantageMultifunction AI + AOAcquisition-Focused Applications

PCI-6281 vs PCI-6284

Both the PCI-6281 and PCI-6284 belong to the high-accuracy M Series family. The PCI-6284 provides a larger analog input channel count, while the PCI-6281 is designed for applications requiring fewer analog inputs together with analog output capability.

ФункцияPCI-6281PCI-6284
Analog Input Resolution18-Bit18-Bit
Single-Ended Analog Inputs1632
Differential Analog Inputs816
I/O Connector ArchitectureSingle VHDCIDual VHDCI
Primary AdvantageCompact Multifunction MeasurementHigher Analog Input Channel Count

68-Pin VHDCI Connectivity

The PCI-6281 uses a 68-pin VHDCI I/O connection.

The appropriate NI cable and terminal block should be selected according to the required signal connections, shielding, mounting method, and application environment.

Before purchasing accessories, verify compatibility with the PCI-6281 rather than selecting accessories only by connector appearance.

Signal Conditioning

Some sensors cannot be connected directly to a multifunction DAQ device and require signal conditioning.

Depending on the sensor and application, signal conditioning may provide:

  • Amplification
  • Filtering
  • Изоляция
  • Sensor excitation
  • Voltage attenuation
  • Current-to-voltage conversion
  • Sensor-specific linearization

The signal-conditioning architecture should be selected according to the sensor output and measurement requirements.

NI-DAQmx Software

The PCI-6281 uses НИ-DAQmx for hardware configuration and application development.

NI-DAQmx provides functionality for:

  • Device configuration
  • Analog input acquisition
  • Analog output generation
  • Цифровой ввод-вывод
  • Counter/timer operations
  • Timing configuration
  • Hardware triggering
  • Calibration information
  • Device diagnostics

LabVIEW Integration

The PCI-6281 can be integrated into LabVIEW-based measurement and automated test applications using compatible NI-DAQmx software.

A typical application workflow is:

Configure Channels → Configure Timing → Configure Trigger → Start Acquisition → Read Data → Analyze → Log Results

Legacy System Replacement

The PCI-6281 is particularly relevant for maintaining existing test systems built around conventional PCI computers.

When replacing a failed PCI-6281 or migrating an older system, verify:

  • PCI slot availability
  • Operating system compatibility
  • NI-DAQmx version
  • LabVIEW version
  • Existing cable compatibility
  • Terminal block compatibility
  • Application source code
  • Timing and triggering requirements
  • Analog input configuration
  • Analog output requirements

How to Choose a Multifunction DAQ Device

Before selecting the PCI-6281, evaluate:

  • Required analog input resolution
  • Required sample rate
  • Number of analog input channels
  • Single-ended or differential measurements
  • Required input voltage ranges
  • Analog output requirements
  • Digital I/O requirements
  • Counter/timer requirements
  • Triggering requirements
  • PCI slot availability
  • Cable and terminal block requirements
  • Sensor signal-conditioning requirements
  • NI-DAQmx compatibility
  • Operating system compatibility

Industries

  • Automated Test
  • Electronic Validation
  • Industrial Measurement
  • Laboratory Automation
  • Research and Development
  • Manufacturing Test
  • Scientific Research
  • Мониторинг процессов
  • Education and Research

Applications

Precision Voltage Measurement

The 18-bit analog input architecture makes the PCI-6281 suitable for applications requiring precise voltage measurements and high measurement resolution.

Sensor Data Acquisition

Compatible sensors and conditioned sensor signals can be acquired through the PCI-6281 for monitoring, research, and automated testing.

Automated Test

Analog input, analog output, digital I/O, counters, and triggering can be combined to build multifunction automated test systems.

Laboratory Automation

The PCI-6281 can acquire experimental data while controlling external equipment through analog and digital signals.

Electronic Validation

Engineers can use the PCI-6281 for voltage monitoring, stimulus generation, digital control, and timing measurements during electronic device validation.

Manufacturing Test

The multifunction architecture supports automated production test applications requiring measurement, control, timing, and pass/fail evaluation.

Recommended Related Products

PCI-628118-bit multifunction PCI DAQ device with analog input, analog output, digital I/O, and counters.
PXI-6281PXI version for modular test and measurement systems requiring similar high-accuracy M Series DAQ functionality.
USB-6281USB-based high-accuracy M Series DAQ option for external and portable measurement systems.
PCI-6280High-accuracy PCI M Series DAQ device for applications focused primarily on analog input acquisition.
PCI-6284Higher-channel-count 18-bit M Series PCI DAQ device for applications requiring additional analog inputs.
PCI-6289High-channel-count M Series multifunction DAQ device for more extensive measurement and control systems.

Why Choose PCI-6281?

  • 18-bit analog input resolution
  • Up to 625 kS/s analog acquisition
  • 16 single-ended analog inputs
  • 8 differential analog inputs
  • 2 analog output channels
  • 24 digital I/O lines
  • Two 32-bit counters/timers
  • Analog and digital triggering
  • PCI host interface
  • 68-pin VHDCI connectivity
  • NI-DAQmx support
  • Интеграция LabVIEW
  • Suitable for precision measurement
  • Suitable for automated testing
  • Suitable for laboratory automation

Frequently Asked Questions

What is the NI PCI-6281?

The NI PCI-6281 is an 18-bit M Series multifunction data acquisition device for PCI-based computers. It combines analog input, analog output, digital I/O, counters/timers, and hardware triggering.

What is the analog input resolution of PCI-6281?

The PCI-6281 provides 18-bit analog input resolution, making it suitable for high-accuracy measurement applications.

What is the maximum sample rate of PCI-6281?

The PCI-6281 supports analog input sampling rates up to 625 kS/s.

How many analog input channels does PCI-6281 have?

The PCI-6281 supports up to 16 single-ended analog inputs or 8 differential analog inputs.

Does PCI-6281 have analog outputs?

Yes. The PCI-6281 provides two analog output channels for programmable signal generation and control applications.

How many digital I/O lines does PCI-6281 have?

The PCI-6281 provides 24 digital I/O lines.

Does PCI-6281 have counters?

Yes. The PCI-6281 provides two 32-bit counters/timers for frequency, period, event-counting, encoder, pulse-generation, and timing applications.

What connector does PCI-6281 use?

The PCI-6281 uses a 68-pin VHDCI I/O connector. Compatible NI cables and terminal blocks should be selected according to the required wiring architecture.

What is the difference between PCI-6281 and PXI-6281?

The primary difference is the system interface. PCI-6281 installs in a conventional PCI computer, while PXI-6281 installs in a PXI chassis. They provide closely related M Series DAQ functionality.

What is the difference between PCI-6281 and USB-6281?

PCI-6281 is an internal PCI DAQ board, while USB-6281 is an external USB-based DAQ device. The appropriate model depends primarily on the required host interface and system architecture.

What is the difference between PCI-6281 and PCI-6280?

Both are high-accuracy M Series DAQ devices, but the PCI-6281 includes two analog output channels, making it more suitable for multifunction applications requiring both measurement and analog signal generation.

Can PCI-6281 be used with LabVIEW?

Yes. PCI-6281 can be used in LabVIEW data acquisition and automated test applications through compatible NI-DAQmx software.

What driver does PCI-6281 use?

The PCI-6281 uses the НИ-DAQmx driver architecture.

Can PCI-6281 measure sensors directly?

It can directly acquire compatible voltage signals. Sensors requiring excitation, amplification, isolation, filtering, or other signal conditioning require appropriate external signal-conditioning hardware.

Can PCI-6281 be used for differential measurements?

Yes. The PCI-6281 supports up to eight differential analog input channels. Differential measurement can be useful when improved common-mode noise rejection is required.

Can PCI-6281 generate analog signals?

Yes. Its two analog output channels can generate programmable voltage signals for device excitation, control, stimulus generation, and automated testing.

What should I check before purchasing a PCI-6281?

Before purchasing, verify the required 18-bit measurement resolution, analog input channel count, sample rate, analog output requirements, digital I/O, counters, PCI slot availability, 68-pin cable and terminal block compatibility, signal-conditioning requirements, operating system, NI-DAQmx version, and application software compatibility.

Заключение

Земля NI PCI-6281 M Series Multifunction DAQ combines high-resolution 18-bit analog acquisition with up to 16 single-ended or 8 differential analog inputs, two analog outputs, 24 digital I/O lines, two 32-bit counters/timers, and hardware triggering. Its combination of precision measurement and multifunction I/O makes it well suited for laboratory automation, sensor acquisition, electronic validation, research, manufacturing test, process monitoring, and legacy PCI-based automated test systems.

Part Number(s): 779109-01

Specifications

Количество двунаправленных цифровых каналов: 24
Питание от шины
Максимальное количество односторонних аналоговых входов: 16
Number of Counters/Timers: 2
Максимальное количество дифференциальных аналоговых входных каналов: 8
Analog Input Absolute Accuracy: 980 μV
Размер FIFO буфера аналогового ввода: 2047 выборок
Maximum Sample Rate: 625 kS/s
Одновременная выборка: Нет
В комплект входит: Да
Analog Input Resolution: 18 bits
Bus Connector: PCI
Front Connection Type: VHDCI(1)
Число аналоговых выходных каналов: 2
Maximum Analog Update Rate: 2.86 MS/s
Bus Connection: PCI

Бренд

Национальные инструменты

Сопутствующие товары

Недавно просмотренные

Frequently Asked Questions

Yes. We can provide new and original products sourced through reliable supply channels. Depending on availability and customer requirements, selected models may also be available in used or refurbished condition. Please confirm the required condition when requesting a quotation.

Please contact us with the required model number, quantity, and application requirements. We provide competitive quotations and project-based pricing according to your purchasing needs.

Stock availability changes regularly. Some models are available for immediate shipment, while others require factory ordering or sourcing. Contact us with the exact model and part number for the latest availability.

Yes, we provide worldwide shipping solutions for customers in different countries and regions. We can arrange reliable logistics services based on your destination and delivery requirements.

Yes, our technical team can help verify specifications, system compatibility, accessories, and product selection based on your application requirements.