{"id":744,"count":19,"description":"<div class=\"category-introduction ni-max-guide\">\r\n  <h2>NI PXI Programmable Power Supplies and SMUs<\/h2>\r\n\r\n  <div class=\"intro-box\">\r\n    <p>NI PXI Programmable Power Supplies and Source Measure Units provide software-controlled DC power, precision voltage and current sourcing, electrical measurement, current limiting and automated device characterization. They integrate DUT power and parametric measurement with PXI switching, digital, RF and waveform instruments in one synchronized test platform.<\/p>\r\n\r\n    <p>The correct instrument depends on more than maximum voltage and current. Engineers must consider channel count, source and sink operation, DC and pulsed power, current sensitivity, compliance limits, measurement speed, remote sensing, guarding, auxiliary power, chassis cooling and DUT connection requirements.<\/p>\r\n  <\/div>\r\n\r\n  <h3>Programmable Power Supply or Source Measure Unit?<\/h3>\r\n\r\n  <p>A programmable power supply primarily delivers controlled DC power to a device under test. It is well suited to functional testing, voltage-margin testing, multiple DUT power rails, startup analysis and automated power sequencing.<\/p>\r\n\r\n  <p>A Source Measure Unit, or SMU, combines precision voltage and current sourcing with precision voltage and current measurement. Many SMUs support four-quadrant operation, allowing them to source or sink current under positive or negative voltage conditions. This makes them more appropriate for semiconductor characterization, leakage measurement and current-voltage sweeps.<\/p>\r\n\r\n  <div class=\"table-wrap\">\r\n    <table>\r\n      <thead>\r\n        <tr>\r\n          <th>Selection Factor<\/th>\r\n          <th>Programmable Power Supply<\/th>\r\n          <th>Source Measure Unit<\/th>\r\n        <\/tr>\r\n      <\/thead>\r\n      <tbody>\r\n        <tr>\r\n          <td>Primary Function<\/td>\r\n          <td>Provide controlled DUT power<\/td>\r\n          <td>Source and precisely measure voltage or current<\/td>\r\n        <\/tr>\r\n        <tr>\r\n          <td>Typical Operation<\/td>\r\n          <td>Program voltage with a current limit<\/td>\r\n          <td>Source voltage and measure current, or source current and measure voltage<\/td>\r\n        <\/tr>\r\n        <tr>\r\n          <td>Current Measurement<\/td>\r\n          <td>Readback and power-consumption monitoring<\/td>\r\n          <td>Precision current measurement across multiple ranges<\/td>\r\n        <\/tr>\r\n        <tr>\r\n          <td>Source and Sink Capability<\/td>\r\n          <td>Usually source-oriented and model dependent<\/td>\r\n          <td>Four-quadrant operation on applicable models<\/td>\r\n        <\/tr>\r\n        <tr>\r\n          <td>I-V Sweeps<\/td>\r\n          <td>Not the primary application<\/td>\r\n          <td>Core capability<\/td>\r\n        <\/tr>\r\n        <tr>\r\n          <td>Low-Current Measurement<\/td>\r\n          <td>Model dependent<\/td>\r\n          <td>Available down to picoampere or femtoampere-class sensitivity on selected models<\/td>\r\n        <\/tr>\r\n        <tr>\r\n          <td>\u0422\u0438\u043f\u0438\u0447\u043d\u044b\u0435 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f<\/td>\r\n          <td>DUT power, functional test and rail sequencing<\/td>\r\n          <td>Semiconductor, component and parametric characterization<\/td>\r\n        <\/tr>\r\n      <\/tbody>\r\n    <\/table>\r\n  <\/div>\r\n\r\n  <div class=\"note-box\">\r\n    <p>Maximum voltage and maximum current cannot always be used simultaneously. Every power supply and SMU operates within a defined voltage-current-power envelope. Check the required DUT operating point, continuous duration and pulse conditions against the exact model specifications.<\/p>\r\n  <\/div>\r\n\r\n  <h3>NI PXI Power Supply and SMU Model Comparison<\/h3>\r\n\r\n  <div class=\"table-wrap\">\r\n    <table>\r\n      <thead>\r\n        <tr>\r\n          <th>\u041c\u043e\u0434\u0435\u043b\u044c<\/th>\r\n          <th>Unique Category<\/th>\r\n          <th>Key Configuration<\/th>\r\n          <th>Best Fit<\/th>\r\n        <\/tr>\r\n      <\/thead>\r\n      <tbody>\r\n        <tr>\r\n          <td><a class=\"product-link\" href=\"https:\/\/pxisource.com\/ru\/product\/pxi-4110\/\">\u041fXI-4110<\/a><\/td>\r\n          <td>Three-Rail Classic PXI Supply<\/td>\r\n          <td>Three outputs including 0 V to 6 V and positive and negative 20 V rails, with current capability up to 1 A<\/td>\r\n          <td>Legacy PXI systems requiring logic and bipolar analog power rails<\/td>\r\n        <\/tr>\r\n        <tr>\r\n          <td><a class=\"product-link\" href=\"https:\/\/pxisource.com\/ru\/product\/pxie-4112\/\">PXIe-4112<\/a><\/td>\r\n          <td>Dual-Channel High-Voltage Supply<\/td>\r\n          <td>Two isolated channels, up to 60 V and 1 A per channel, 120 W total output power<\/td>\r\n          <td>Higher-voltage functional testing and independently controlled DUT rails<\/td>\r\n        <\/tr>\r\n        <tr>\r\n          <td><a class=\"product-link\" href=\"https:\/\/pxisource.com\/ru\/product\/pxie-4113\/\">PXIe-4113<\/a><\/td>\r\n          <td>Dual-Channel High-Current Supply<\/td>\r\n          <td>Two isolated channels, up to 10 V and 6 A per channel, 120 W total output power<\/td>\r\n          <td>Low-voltage electronics requiring higher current<\/td>\r\n        <\/tr>\r\n        <tr>\r\n          <td><a class=\"product-link\" href=\"https:\/\/pxisource.com\/ru\/product\/pxie-4137\/\">PXIe-4137<\/a><\/td>\r\n          <td>200 V Precision System SMU<\/td>\r\n          <td>One channel, \u00b1200 V, \u00b11 A DC, \u00b13 A pulsed, up to 40 W DC and 100 fA current sensitivity<\/td>\r\n          <td>High-voltage semiconductor, optoelectronic and component characterization<\/td>\r\n        <\/tr>\r\n        <tr>\r\n          <td><a class=\"product-link\" href=\"https:\/\/pxisource.com\/ru\/product\/pxie-4139\/\">PXIe-4139<\/a><\/td>\r\n          <td>High-Current Pulse System SMU<\/td>\r\n          <td>One channel, \u00b160 V, \u00b13 A DC, \u00b110 A pulsed, up to 40 W DC and 100 fA current sensitivity<\/td>\r\n          <td>PMIC, RFIC, LED and power-device characterization<\/td>\r\n        <\/tr>\r\n        <tr>\r\n          <td><a class=\"product-link\" href=\"https:\/\/pxisource.com\/ru\/product\/pxie-4140\/\">PXIe-4140<\/a><\/td>\r\n          <td>General-Purpose 10 V Four-Channel SMU<\/td>\r\n          <td>Four channels, \u00b110 V, 100 mA, four-quadrant operation and 100 pA current sensitivity<\/td>\r\n          <td>Multi-terminal devices and moderate-precision automated measurements<\/td>\r\n        <\/tr>\r\n        <tr>\r\n          <td><a class=\"product-link\" href=\"https:\/\/pxisource.com\/ru\/product\/pxie-4141\/\">PXIe-4141<\/a><\/td>\r\n          <td>Precision 10 V Four-Channel SMU<\/td>\r\n          <td>Four channels, \u00b110 V, 100 mA, 10 pA sensitivity and SourceAdapt transient-response control<\/td>\r\n          <td>Low-current, multi-pin semiconductor characterization<\/td>\r\n        <\/tr>\r\n        <tr>\r\n          <td><a class=\"product-link\" href=\"https:\/\/pxisource.com\/ru\/product\/pxie-4142\/\">PXIe-4142<\/a><\/td>\r\n          <td>General-Purpose 24 V Four-Channel SMU<\/td>\r\n          <td>Four channels, \u00b124 V, 150 mA, 3.6 W per channel and 100 pA sensitivity<\/td>\r\n          <td>Multi-rail IC and component testing requiring wider voltage range<\/td>\r\n        <\/tr>\r\n        <tr>\r\n          <td><a class=\"product-link\" href=\"https:\/\/pxisource.com\/ru\/product\/pxie-4143\/\">PXIe-4143<\/a><\/td>\r\n          <td>Precision 24 V Four-Channel SMU<\/td>\r\n          <td>Four channels, \u00b124 V, 150 mA, 10 pA sensitivity and SourceAdapt<\/td>\r\n          <td>Precision multi-terminal semiconductor and sensor characterization<\/td>\r\n        <\/tr>\r\n        <tr>\r\n          <td><a class=\"product-link\" href=\"https:\/\/pxisource.com\/ru\/product\/pxie-4144\/\">PXIe-4144<\/a><\/td>\r\n          <td>Low-Voltage High-Current Four-Channel SMU<\/td>\r\n          <td>Four channels, \u00b16 V, 500 mA and up to 3 W source or sink power per channel<\/td>\r\n          <td>Low-voltage IC rails and devices needing more current per channel<\/td>\r\n        <\/tr>\r\n        <tr>\r\n          <td><a class=\"product-link\" href=\"https:\/\/pxisource.com\/ru\/product\/pxie-4147\/\">PXIe-4147<\/a><\/td>\r\n          <td>High-Current Precision Four-Channel SMU<\/td>\r\n          <td>Four channels, \u00b18 V, \u00b13 A, up to 24 W per channel, 100 fA sensitivity and SourceAdapt<\/td>\r\n          <td>High-current PMIC and semiconductor production testing<\/td>\r\n        <\/tr>\r\n        <tr>\r\n          <td><a class=\"product-link\" href=\"https:\/\/pxisource.com\/ru\/product\/pxie-4150\/\">PXIe-4150<\/a><\/td>\r\n          <td>60 V 300 W PXI Power Supply<\/td>\r\n          <td>One channel, up to 60 V, 10 A and 300 W with high-speed voltage and current measurement<\/td>\r\n          <td>Higher-voltage boards, converters and electronic assemblies<\/td>\r\n        <\/tr>\r\n        <tr>\r\n          <td><a class=\"product-link\" href=\"https:\/\/pxisource.com\/ru\/product\/pxie-4151\/\">PXIe-4151<\/a><\/td>\r\n          <td>25 A 300 W PXI Power Supply<\/td>\r\n          <td>One channel, up to 20 V, 25 A and 300 W with remote sensing and integrated measurement<\/td>\r\n          <td>Low-voltage, high-current DUT and PMIC power testing<\/td>\r\n        <\/tr>\r\n        <tr>\r\n          <td><a class=\"product-link\" href=\"https:\/\/pxisource.com\/ru\/product\/%d0%bf%d0%ba%d1%81%d0%b8%d0%b5-4162\/\">PXIe-4162<\/a><\/td>\r\n          <td>Guarded 12-Channel Precision SMU<\/td>\r\n          <td>Twelve identical \u00b124 V SMU channels with remote sensing, guarding and SourceAdapt<\/td>\r\n          <td>Precision mixed-signal IC and multi-site production test<\/td>\r\n        <\/tr>\r\n        <tr>\r\n          <td><a class=\"product-link\" href=\"https:\/\/pxisource.com\/ru\/product\/pxie-4163\/\">PXIe-4163<\/a><\/td>\r\n          <td>24-Channel High-Density Precision SMU<\/td>\r\n          <td>Twenty-four identical \u00b124 V SMU channels with four-quadrant operation and SourceAdapt<\/td>\r\n          <td>High-pin-count ICs and systems requiring maximum SMU channel density<\/td>\r\n        <\/tr>\r\n        <tr>\r\n          <td><a class=\"product-link\" href=\"https:\/\/pxisource.com\/ru\/product\/pxie-4190\/\">PXIe-4190<\/a><\/td>\r\n          <td>LCR Meter with Integrated SMU<\/td>\r\n          <td>Up to 2 MHz LCR stimulus, up to \u00b140 V DC bias and femtoampere-class SMU measurement on selected configuration<\/td>\r\n          <td>Capacitance-voltage, impedance and semiconductor parametric testing<\/td>\r\n        <\/tr>\r\n        <tr>\r\n          <td><a class=\"product-link\" href=\"https:\/\/pxisource.com\/ru\/product\/rmx-4101\/\">RMX-4101<\/a><\/td>\r\n          <td>Compact 216 W Rack Power Supply<\/td>\r\n          <td>Single-channel 2U rack supply with configurations up to 216 W, 100 V or 10 A<\/td>\r\n          <td>Compact rack systems needing moderate programmable DC power<\/td>\r\n        <\/tr>\r\n        <tr>\r\n          <td><a class=\"product-link\" href=\"https:\/\/pxisource.com\/ru\/product\/rmx-4102\/\">RMX-4102<\/a><\/td>\r\n          <td>Compact 432 W Rack Power Supply<\/td>\r\n          <td>Single-channel 2U rack supply with configurations up to 432 W, 100 V or 20 A<\/td>\r\n          <td>Higher-power rack-mounted functional test systems<\/td>\r\n        <\/tr>\r\n        <tr>\r\n          <td><a class=\"product-link\" href=\"https:\/\/pxisource.com\/ru\/product\/rmx-4123\/\">RMX-4123<\/a><\/td>\r\n          <td>High-Voltage 750 W Rack Power Supply<\/td>\r\n          <td>One channel, 0 V to 650 V, up to 3.5 A and 750 W in a 1U full-width enclosure<\/td>\r\n          <td>High-voltage component, insulation and power-electronics testing<\/td>\r\n        <\/tr>\r\n      <\/tbody>\r\n    <\/table>\r\n  <\/div>\r\n\r\n  <div class=\"note-box\">\r\n    <p>The RMX-4101, RMX-4102 and RMX-4123 are standalone or rack-mounted power supplies rather than PXI plug-in modules. The PXIe-4190 is primarily an LCR meter with integrated SMU capability. Confirm the required form factor before including these instruments in a PXI system quotation.<\/p>\r\n  <\/div>\r\n\r\n  <h3>How to Select a PXI Programmable Power Supply or SMU<\/h3>\r\n\r\n  <h4>1. Define the DUT Voltage Range<\/h4>\r\n\r\n  <p>Record the minimum and maximum voltage required for normal operation, margin testing, startup, shutdown and fault simulation. Include any negative-bias requirement. A unipolar programmable power supply cannot replace a bipolar four-quadrant SMU when both voltage polarities are required.<\/p>\r\n\r\n  <p>Do not automatically select the highest available voltage. A lower-voltage instrument may provide greater current, better channel density or more suitable measurement ranges.<\/p>\r\n\r\n  <h4>2. Determine Continuous and Pulsed Current<\/h4>\r\n\r\n  <p>Specify continuous current separately from short-duration peak current. Wireless transmitters, processors, PMICs, LEDs and other devices can draw brief current pulses substantially higher than their steady-state consumption.<\/p>\r\n\r\n  <p>For pulsed operation, identify pulse amplitude, duration, repetition rate, duty cycle and acceptable voltage droop. Verify the complete pulsed operating envelope rather than relying only on a headline peak-current value.<\/p>\r\n\r\n  <h4>3. Check the Complete Power Envelope<\/h4>\r\n\r\n  <p>Voltage, current and power limits must be evaluated together. For example, the PXIe-4150 supports up to 60 V and 10 A but has a maximum output power of 300 W, so it cannot supply 60 V at 10 A simultaneously.<\/p>\r\n\r\n  <p>Plot demanding DUT operating points against the model\u2019s quadrant or power-envelope diagram. This is particularly important for power converters, PMICs, LEDs, active devices and loads whose current changes significantly during testing.<\/p>\r\n\r\n  <h4>4. Determine Whether the Instrument Must Sink Current<\/h4>\r\n\r\n  <p>A conventional single-quadrant power supply normally delivers power to the DUT. Four-quadrant SMUs can source or absorb current within their specified operating envelopes.<\/p>\r\n\r\n  <p>Controlled sinking may be required when testing active circuits, charged capacitive devices, bidirectional power stages or source-like DUTs. High-power discharge testing may require a dedicated electronic load rather than a precision SMU.<\/p>\r\n\r\n  <h4>5. Specify the Required Measurement Sensitivity<\/h4>\r\n\r\n  <p>Maximum current does not describe the complete measurement requirement. Semiconductor test can involve amperes during active operation and picoamperes or femtoamperes during leakage measurements.<\/p>\r\n\r\n  <p>Document the smallest current that must be measured, required accuracy, acceptable noise, measurement time and expected DUT capacitance. Selectable current ranges, aperture time, settling time and environmental leakage can all affect the usable result.<\/p>\r\n\r\n  <h4>6. Calculate the Required Channel Count<\/h4>\r\n\r\n  <p>Count every DUT supply rail, bias terminal and independent source-measure connection. Then include the number of DUTs that will be tested simultaneously.<\/p>\r\n\r\n  <p>A single-channel system SMU may provide the best performance for one demanding terminal. Four-, 12- or 24-channel SMUs can provide better density for high-pin-count devices and parallel semiconductor production testing.<\/p>\r\n\r\n  <h4>7. Confirm Remote Sense and Guarding<\/h4>\r\n\r\n  <p>Remote sensing uses separate force and sense conductors to compensate for voltage drop in cables, switches and fixtures. It is particularly important in high-current applications and whenever the voltage must be controlled accurately at the DUT terminals.<\/p>\r\n\r\n  <p>Guarding helps reduce leakage through cables, connectors and fixtures during very-low-current measurements. A precision SMU cannot deliver femtoampere-class system performance if the fixture, switching or contamination introduces substantially greater leakage.<\/p>\r\n\r\n  <h4>8. Evaluate Speed, Sequencing and Synchronization<\/h4>\r\n\r\n  <p>Measurement speed affects production throughput and transient capture. Selected PXI power instruments can acquire voltage and current at high rates, perform hardware-timed source sequences and coordinate operations through PXI trigger lines.<\/p>\r\n\r\n  <p>Define whether the application needs static DC readings, fast rail sequencing, I-V sweeps, startup-current capture or synchronization with digital, RF or waveform instruments.<\/p>\r\n\r\n  <h3>Four-Quadrant SMU Operation<\/h3>\r\n\r\n  <div class=\"table-wrap\">\r\n    <table>\r\n      <thead>\r\n        <tr>\r\n          <th>Quadrant<\/th>\r\n          <th>Voltage<\/th>\r\n          <th>Current<\/th>\r\n          <th>Instrument Behavior<\/th>\r\n        <\/tr>\r\n      <\/thead>\r\n      <tbody>\r\n        <tr>\r\n          <td>I<\/td>\r\n          <td>Positive<\/td>\r\n          <td>Positive<\/td>\r\n          <td>Sources power under positive bias<\/td>\r\n        <\/tr>\r\n        <tr>\r\n          <td>II<\/td>\r\n          <td>Positive<\/td>\r\n          <td>Negative<\/td>\r\n          <td>Sinks power under positive bias<\/td>\r\n        <\/tr>\r\n        <tr>\r\n          <td>III<\/td>\r\n          <td>Negative<\/td>\r\n          <td>Negative<\/td>\r\n          <td>Sources power under negative bias<\/td>\r\n        <\/tr>\r\n        <tr>\r\n          <td>IV<\/td>\r\n          <td>Negative<\/td>\r\n          <td>Positive<\/td>\r\n          <td>Sinks power under negative bias<\/td>\r\n        <\/tr>\r\n      <\/tbody>\r\n    <\/table>\r\n  <\/div>\r\n\r\n  <p>Four-quadrant capability supports positive and negative device bias, controlled sourcing and sinking, and characterization across a wider I-V region. The permitted voltage, current and power are still limited by the exact model\u2019s quadrant diagram.<\/p>\r\n\r\n  <h3>Precision I-V and Leakage Measurements<\/h3>\r\n\r\n  <p>An SMU can source a series of voltage values and measure the resulting current, or source current and measure voltage. The resulting I-V curve can identify forward voltage, threshold behavior, resistance, breakdown behavior, leakage and other electrical characteristics.<\/p>\r\n\r\n  <p>Common devices include:<\/p>\r\n\r\n  <ul>\r\n    <li>Diodes, LEDs and laser diodes<\/li>\r\n    <li>MOSFETs and bipolar transistors<\/li>\r\n    <li>Power-management integrated circuits<\/li>\r\n    <li>RF and mixed-signal integrated circuits<\/li>\r\n    <li>MEMS devices and semiconductor sensors<\/li>\r\n    <li>Optical transceivers and optoelectronic components<\/li>\r\n    <li>Passive devices requiring DC-bias characterization<\/li>\r\n  <\/ul>\r\n\r\n  <p>For low-current measurements, use suitable triaxial or low-leakage cabling where required, keep connectors clean and dry, control fixture leakage and allow sufficient settling time. Switching modules must also support the required leakage, isolation, guarding and four-wire topology.<\/p>\r\n\r\n  <h3>PXI Power Sequencing and Transient Testing<\/h3>\r\n\r\n  <p>Modern DUTs often contain several rails that must be enabled and disabled in a defined order. A PXI power system can coordinate rail sequencing with digital inputs, oscilloscopes, waveform generators and switching modules.<\/p>\r\n\r\n  <div class=\"solution-box\">\r\n    <p>A typical automated power-up test may:<\/p>\r\n    <ol>\r\n      <li>Configure voltage levels and compliance limits.<\/li>\r\n      <li>Enable the primary DUT supply.<\/li>\r\n      <li>Enable secondary bias and logic rails after defined delays.<\/li>\r\n      <li>Capture startup voltage and current waveforms.<\/li>\r\n      <li>Run functional or parametric measurements.<\/li>\r\n      <li>Disable the rails in the specified shutdown order.<\/li>\r\n    <\/ol>\r\n  <\/div>\r\n\r\n  <p>Selected instruments provide programmable transient-response control through NI SourceAdapt technology. This helps balance settling time, overshoot and stability for capacitive loads, long cables and complex test fixtures.<\/p>\r\n\r\n  <h3>Auxiliary Power, Cooling and PXI Compatibility<\/h3>\r\n\r\n  <p>High-power PXI modules can require more input power and cooling than ordinary measurement cards. The PXIe-4112 and PXIe-4113 are available in configurations with or without their auxiliary power source, while the PXIe-4150 and PXIe-4151 require compatible APS-415x auxiliary power hardware.<\/p>\r\n\r\n  <p>Before ordering, verify:<\/p>\r\n\r\n  <ul>\r\n    <li>Classic PXI, PXI Hybrid or PXI Express slot compatibility<\/li>\r\n    <li>Number of adjacent slots required by the module<\/li>\r\n    <li>Chassis cooling capacity per slot<\/li>\r\n    <li>Required auxiliary power model and power cable<\/li>\r\n    <li>Total power consumption of all installed modules<\/li>\r\n    <li>Ambient-temperature and airflow requirements<\/li>\r\n    <li>Output connector, force\/sense cable and fixture compatibility<\/li>\r\n  <\/ul>\r\n\r\n  <p>Select a compatible <a class=\"product-link\" href=\"https:\/\/pxisource.com\/ru\/product-category\/%d0%bd%d0%b8\/pxi-%d1%81%d0%b8%d1%81%d1%82%d0%b5%d0%bc%d1%81\/pxi-chassis\/\">PXI or PXIe chassis<\/a> by slot type, power and cooling\u2014not only by the number of available slots.<\/p>\r\n\r\n  <h3>Software and Test-System Integration<\/h3>\r\n\r\n  <p>NI PXI programmable power supplies, SMUs and the PXIe-4190 use NI-DCPower for supported instrument configuration and automation. Depending on the model, NI-DCPower can control voltage, current, compliance limits, measurement ranges, source sequences, triggers and output-disconnect states.<\/p>\r\n\r\n  <p>InstrumentStudio provides interactive instrument panels for initial setup and troubleshooting. LabVIEW, Python, C\/C++, C# and other supported environments can be used for custom automation, while TestStand can coordinate complete production-test sequences.<\/p>\r\n\r\n  <p>A complete automated system may combine the power instrument with:<\/p>\r\n\r\n  <ul>\r\n    <li><a class=\"product-link\" href=\"https:\/\/pxisource.com\/ru\/product-category\/%d0%bd%d0%b8\/pxi-%d1%81%d0%b8%d1%81%d1%82%d0%b5%d0%bc%d1%81\/%d0%bc%d0%be%d0%b4%d1%83%d0%bb%d0%b8-pxi\/pxi-switches\/\">PXI switches<\/a> for routing instruments to multiple terminals or DUT sites<\/li>\r\n    <li>Digital pattern instruments for semiconductor functional testing<\/li>\r\n    <li><a class=\"product-link\" href=\"https:\/\/pxisource.com\/ru\/product-category\/%d0%bd%d0%b8\/pxi-%d1%81%d0%b8%d1%81%d1%82%d0%b5%d0%bc%d1%81\/%d0%bc%d0%be%d0%b4%d1%83%d0%bb%d0%b8-pxi\/pxi-oscilloscopes-digitizers\/\">PXI oscilloscopes and digitizers<\/a> for transient waveform acquisition<\/li>\r\n    <li><a class=\"product-link\" href=\"https:\/\/pxisource.com\/ru\/product-category\/%d0%bd%d0%b8\/pxi-%d1%81%d0%b8%d1%81%d1%82%d0%b5%d0%bc%d1%81\/%d0%bc%d0%be%d0%b4%d1%83%d0%bb%d0%b8-pxi\/pxi-signal-generators\/\">PXI signal generators<\/a> for device stimulus<\/li>\r\n    <li>RF instruments for RFIC and wireless-device testing<\/li>\r\n    <li>Digital multimeters for additional precision measurements<\/li>\r\n  <\/ul>\r\n\r\n  <h3>\u0422\u0438\u043f\u0438\u0447\u043d\u044b\u0435 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f<\/h3>\r\n\r\n  <ul>\r\n    <li>Semiconductor wafer and packaged-device characterization<\/li>\r\n    <li>PMIC active, standby, shutdown and leakage-current testing<\/li>\r\n    <li>Multi-site semiconductor production test<\/li>\r\n    <li>PCB assembly and electronic product functional testing<\/li>\r\n    <li>Automated voltage-margin and power-sequencing tests<\/li>\r\n    <li>LED, laser-diode and optical-transceiver characterization<\/li>\r\n    <li>Sensor and MEMS electrical testing<\/li>\r\n    <li>Automotive electronic control-unit validation<\/li>\r\n    <li>Aerospace and defense electronics testing<\/li>\r\n    <li>Power-converter and power-management circuit evaluation<\/li>\r\n    <li>Capacitance-voltage and impedance measurement<\/li>\r\n    <li>Laboratory research and automated component characterization<\/li>\r\n  <\/ul>\r\n\r\n  <h3>Legacy PXI Power Instrument Replacement<\/h3>\r\n\r\n  <p>Replacing an older PXI power supply or SMU requires more than matching its maximum voltage and current. Differences in connector type, channel isolation, compliance behavior, transient response, measurement sensitivity and software can require fixture or test-program changes.<\/p>\r\n\r\n  <p>Compare the following before approving a replacement:<\/p>\r\n\r\n  <ul>\r\n    <li>PXI or PXI Express bus and slot compatibility<\/li>\r\n    <li>Number of channels and channel isolation<\/li>\r\n    <li>Voltage, current and source-power envelope<\/li>\r\n    <li>Sink power and quadrant support<\/li>\r\n    <li>Continuous and pulsed-current capability<\/li>\r\n    <li>Minimum current range and measurement sensitivity<\/li>\r\n    <li>Remote-sense and guard connections<\/li>\r\n    <li>Output connector and cable pinout<\/li>\r\n    <li>Auxiliary power and cooling requirements<\/li>\r\n    <li>NI-DCPower and operating-system support<\/li>\r\n    <li>Sequencing, triggering and application-code behavior<\/li>\r\n    <li>Calibration and production requalification requirements<\/li>\r\n  <\/ul>\r\n\r\n  <h3>PXI Power Supply and SMU Procurement Guide<\/h3>\r\n\r\n  <div class=\"solution-box\">\r\n    <p>Provide the following information for accurate model selection and quotation:<\/p>\r\n    <ul>\r\n      <li>Required model and part number, if already selected<\/li>\r\n      <li>Programmable power supply, SMU or LCR measurement requirement<\/li>\r\n      <li>Number of independent channels<\/li>\r\n      <li>Minimum and maximum voltage<\/li>\r\n      <li>Continuous current and maximum source power<\/li>\r\n      <li>Pulse current, pulse duration and duty cycle<\/li>\r\n      <li>Required sink current or sink power<\/li>\r\n      <li>Smallest current that must be measured<\/li>\r\n      <li>Required measurement accuracy and speed<\/li>\r\n      <li>Remote-sense, four-wire and guarding requirements<\/li>\r\n      <li>Existing PXI chassis and controller models<\/li>\r\n      <li>Required auxiliary power, cables and connector accessories<\/li>\r\n      <li>Switching and multi-site test requirements<\/li>\r\n      <li>Operating system and NI-DCPower version<\/li>\r\n      <li>Calibration documentation requirements<\/li>\r\n      <li>Required quantity, condition, destination and delivery date<\/li>\r\n    <\/ul>\r\n  <\/div>\r\n\r\n  <p>Part numbers within one model family can represent different performance, included auxiliary power or current-sensitivity configurations. Quotations should therefore identify both the model and complete NI part number whenever possible.<\/p>\r\n\r\n  <h3>\u0427\u0430\u0441\u0442\u043e \u0437\u0430\u0434\u0430\u0432\u0430\u0435\u043c\u044b\u0435 \u0432\u043e\u043f\u0440\u043e\u0441\u044b<\/h3>\r\n\r\n  <h4>What is the main difference between a PXI power supply and an SMU?<\/h4>\r\n\r\n  <p>A programmable power supply is primarily intended to power the DUT. An SMU is designed to source voltage or current while precisely measuring the corresponding current or voltage. SMUs are generally the better choice for I-V sweeps, leakage measurements and semiconductor parametric testing.<\/p>\r\n\r\n  <h4>Can every PXI SMU sink power?<\/h4>\r\n\r\n  <p>No. Source and sink capability depends on the exact instrument and its operating envelope. Verify four-quadrant operation, maximum sink power and the permitted voltage-current combinations before selection.<\/p>\r\n\r\n  <h4>Which model is suitable for high-voltage precision measurements?<\/h4>\r\n\r\n  <p>The PXIe-4137 supports a voltage range up to \u00b1200 V and is intended for precision system-SMU applications. If the primary need is high-voltage power rather than precision SMU measurement, the rack-mounted RMX-4123 supports up to 650 V and 750 W.<\/p>\r\n\r\n  <h4>Which model provides the highest SMU channel density?<\/h4>\r\n\r\n  <p>The PXIe-4163 provides 24 precision SMU channels. The PXIe-4162 provides 12 channels and adds guarded connections for applications in which low-current leakage control is particularly important.<\/p>\r\n\r\n  <h4>What is the difference between PXIe-4142 and PXIe-4143?<\/h4>\r\n\r\n  <p>Both provide four \u00b124 V, 150 mA SMU channels. The PXIe-4143 is the precision version, offering greater current sensitivity and SourceAdapt transient-response control.<\/p>\r\n\r\n  <h4>What is the difference between PXIe-4150 and PXIe-4151?<\/h4>\r\n\r\n  <p>Both are single-channel 300 W programmable power supplies. The PXIe-4150 supports up to 60 V and 10 A, while the PXIe-4151 supports up to 20 V and 25 A. Select according to the DUT voltage-current operating point.<\/p>\r\n\r\n  <h4>Is the PXIe-4190 a conventional SMU?<\/h4>\r\n\r\n  <p>No. It is primarily an LCR meter with integrated precision SMU functionality. It is intended for impedance, capacitance-voltage, current-voltage and related semiconductor parametric measurements.<\/p>\r\n\r\n  <h4>Are RMX power supplies installed in a PXI chassis?<\/h4>\r\n\r\n  <p>No. RMX models are standalone or rack-mounted instruments. They can operate as part of a PXI-based automated test system but do not occupy PXI peripheral slots.<\/p>\r\n\r\n  <h4>Why is remote sensing important?<\/h4>\r\n\r\n  <p>Force-cable and fixture resistance creates voltage drop when current flows. Remote sensing measures voltage at the DUT and allows the instrument to compensate for this loss, improving voltage accuracy at the device terminals.<\/p>\r\n\r\n  <h3>Recommended NI PXI Power Instruments<\/h3>\r\n\r\n  <div class=\"related-info\">\r\n    <p>Consider the <a class=\"product-link\" href=\"https:\/\/pxisource.com\/ru\/product\/pxie-4113\/\">PXIe-4113<\/a> for two low-voltage, higher-current power channels; the <a class=\"product-link\" href=\"https:\/\/pxisource.com\/ru\/product\/pxie-4139\/\">PXIe-4139<\/a> for high-performance single-channel semiconductor characterization; the <a class=\"product-link\" href=\"https:\/\/pxisource.com\/ru\/product\/pxie-4147\/\">PXIe-4147<\/a> for four high-current precision SMU channels; the <a class=\"product-link\" href=\"https:\/\/pxisource.com\/ru\/product\/pxie-4150\/\">PXIe-4150<\/a> for 300 W power delivery up to 60 V; or the <a class=\"product-link\" href=\"https:\/\/pxisource.com\/ru\/product\/pxie-4163\/\">PXIe-4163<\/a> for high-density 24-channel source-measure testing.<\/p>\r\n  <\/div>\r\n\r\n  <h3>Related NI PXI Solutions<\/h3>\r\n\r\n  <p>Browse additional <a class=\"product-link\" href=\"https:\/\/pxisource.com\/ru\/product-category\/%d0%bd%d0%b8\/pxi-%d1%81%d0%b8%d1%81%d1%82%d0%b5%d0%bc%d1%81\/%d0%bc%d0%be%d0%b4%d1%83%d0%bb%d0%b8-pxi\/\">PXI and PXIe modules<\/a> for switching, waveform generation, digital test, RF measurement and data acquisition. Complete systems also require a compatible <a class=\"product-link\" href=\"https:\/\/pxisource.com\/ru\/product-category\/%d0%bd%d0%b8\/pxi-%d1%81%d0%b8%d1%81%d1%82%d0%b5%d0%bc%d1%81\/pxi-controller\/\">PXI controller<\/a>, chassis, cables and DUT interface selected for the required software, power and cooling configuration.<\/p>\r\n\r\n  <h3>NI PXI Programmable Power Supplies and SMUs from PXISOURCE<\/h3>\r\n\r\n  <p>PXISOURCE supports engineers, system integrators and procurement teams with model selection, part-number verification, chassis compatibility review, auxiliary-power matching, connectivity planning and legacy instrument replacement. Send the DUT voltage-current envelope, channel count, minimum measurable current, pulse requirements and existing PXI configuration for a technically matched quotation.<\/p>\r\n\r\n  <div class=\"contact-email-box\">\r\n    <p>Need help selecting an NI PXI power supply or SMU? Email <a href=\"mailto:sales@pxisource.com\">sales@pxisource.com<\/a> or contact PXISOURCE on <a href=\"https:\/\/wa.me\/8617621710987\">WhatsApp<\/a>.<\/p>\r\n  <\/div>\r\n<\/div>","link":"https:\/\/pxisource.com\/ru\/product-category\/ni\/pxi-systems\/pxi-modules\/pxi-programmable-power-supplies-smu\/","name":"PXI Programmable Power Supplies &amp; SMU","slug":"pxi-programmable-power-supplies-smu","taxonomy":"product_cat","parent":667,"meta":[],"menu_order":9,"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.0 (Yoast SEO v28.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>NI PXI Programmable Power Supplies &amp; SMUs - PXI Source<\/title>\n<meta name=\"description\" content=\"NI PXI programmable power supplies and SMUs for DUT power, precision I-V testing, semiconductor characterization and automated test.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/pxisource.com\/ru\/product-category\/\u043d\u0438\/pxi-\u0441\u0438\u0441\u0442\u0435\u043c\u0441\/\u043c\u043e\u0434\u0443\u043b\u0438-pxi\/pxi-programmable-power-supplies-smu\/\" \/>\n<meta property=\"og:locale\" content=\"ru_RU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"PXI Programmable Power Supplies &amp; SMU Archives\" \/>\n<meta property=\"og:description\" content=\"NI PXI programmable power supplies and SMUs for DUT power, precision I-V testing, semiconductor characterization and automated test.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/pxisource.com\/ru\/product-category\/\u043d\u0438\/pxi-\u0441\u0438\u0441\u0442\u0435\u043c\u0441\/\u043c\u043e\u0434\u0443\u043b\u0438-pxi\/pxi-programmable-power-supplies-smu\/\" \/>\n<meta property=\"og:site_name\" content=\"PXI Source\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"CollectionPage\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product-category\\\/ni\\\/pxi-systems\\\/pxi-modules\\\/pxi-programmable-power-supplies-smu\\\/\",\"url\":\"https:\\\/\\\/pxisource.com\\\/product-category\\\/ni\\\/pxi-systems\\\/pxi-modules\\\/pxi-programmable-power-supplies-smu\\\/\",\"name\":\"NI PXI Programmable Power Supplies & SMUs - PXI Source\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\"},\"description\":\"NI PXI programmable power supplies and SMUs for DUT power, precision I-V testing, semiconductor characterization and automated test.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product-category\\\/ni\\\/pxi-systems\\\/pxi-modules\\\/pxi-programmable-power-supplies-smu\\\/#breadcrumb\"},\"inLanguage\":\"ru-RU\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product-category\\\/ni\\\/pxi-systems\\\/pxi-modules\\\/pxi-programmable-power-supplies-smu\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/pxisource.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"National Instruments\",\"item\":\"https:\\\/\\\/pxisource.com\\\/product-category\\\/ni\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"PXI Systems\",\"item\":\"https:\\\/\\\/pxisource.com\\\/product-category\\\/ni\\\/pxi-systems\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"PXI Modules\",\"item\":\"https:\\\/\\\/pxisource.com\\\/product-category\\\/ni\\\/pxi-systems\\\/pxi-modules\\\/\"},{\"@type\":\"ListItem\",\"position\":5,\"name\":\"PXI Programmable Power Supplies &amp; SMU\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\",\"url\":\"https:\\\/\\\/pxisource.com\\\/\",\"name\":\"PXI Systems\",\"description\":\"NI PXI, PXIe Modular Test Instrument Supplier\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/pxisource.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ru-RU\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"NI PXI Programmable Power Supplies & SMUs - PXI Source","description":"NI PXI programmable power supplies and SMUs for DUT power, precision I-V testing, semiconductor characterization and automated test.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/pxisource.com\/ru\/product-category\/\u043d\u0438\/pxi-\u0441\u0438\u0441\u0442\u0435\u043c\u0441\/\u043c\u043e\u0434\u0443\u043b\u0438-pxi\/pxi-programmable-power-supplies-smu\/","og_locale":"ru_RU","og_type":"article","og_title":"PXI Programmable Power Supplies &amp; SMU Archives","og_description":"NI PXI programmable power supplies and SMUs for DUT power, precision I-V testing, semiconductor characterization and automated test.","og_url":"https:\/\/pxisource.com\/ru\/product-category\/\u043d\u0438\/pxi-\u0441\u0438\u0441\u0442\u0435\u043c\u0441\/\u043c\u043e\u0434\u0443\u043b\u0438-pxi\/pxi-programmable-power-supplies-smu\/","og_site_name":"PXI Source","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"CollectionPage","@id":"https:\/\/pxisource.com\/product-category\/ni\/pxi-systems\/pxi-modules\/pxi-programmable-power-supplies-smu\/","url":"https:\/\/pxisource.com\/product-category\/ni\/pxi-systems\/pxi-modules\/pxi-programmable-power-supplies-smu\/","name":"NI PXI Programmable Power Supplies & SMUs - PXI Source","isPartOf":{"@id":"https:\/\/pxisource.com\/#website"},"description":"NI PXI programmable power supplies and SMUs for DUT power, precision I-V testing, semiconductor characterization and automated test.","breadcrumb":{"@id":"https:\/\/pxisource.com\/product-category\/ni\/pxi-systems\/pxi-modules\/pxi-programmable-power-supplies-smu\/#breadcrumb"},"inLanguage":"ru-RU"},{"@type":"BreadcrumbList","@id":"https:\/\/pxisource.com\/product-category\/ni\/pxi-systems\/pxi-modules\/pxi-programmable-power-supplies-smu\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/pxisource.com\/"},{"@type":"ListItem","position":2,"name":"National Instruments","item":"https:\/\/pxisource.com\/product-category\/ni\/"},{"@type":"ListItem","position":3,"name":"PXI Systems","item":"https:\/\/pxisource.com\/product-category\/ni\/pxi-systems\/"},{"@type":"ListItem","position":4,"name":"PXI Modules","item":"https:\/\/pxisource.com\/product-category\/ni\/pxi-systems\/pxi-modules\/"},{"@type":"ListItem","position":5,"name":"PXI Programmable Power Supplies &amp; SMU"}]},{"@type":"WebSite","@id":"https:\/\/pxisource.com\/#website","url":"https:\/\/pxisource.com\/","name":"\u0421\u0438\u0441\u0442\u0435\u043c\u044b PXI","description":"NI PXI, PXIe Modular Test Instrument Supplier","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/pxisource.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ru-RU"}]}},"_links":{"self":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_cat\/744","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_cat"}],"about":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/taxonomies\/product_cat"}],"up":[{"embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_cat\/667"}],"wp:post_type":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product?product_cat=744"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}