{"id":71,"date":"2025-08-20T09:42:11","date_gmt":"2025-08-20T01:42:11","guid":{"rendered":"https:\/\/pxisource.com\/?post_type=product&#038;p=71"},"modified":"2026-09-07T12:06:31","modified_gmt":"2026-09-07T04:06:31","slug":"%d0%bf%d1%8c%d0%b5-1095","status":"publish","type":"product","link":"https:\/\/pxisource.com\/ru\/product\/pxie-1095\/","title":{"rendered":"PXIe-1095"},"content":{"rendered":"<h3>PXIe-1095 18-Slot PXI Express Chassis<\/h3>\n<p>\u0417\u0435\u043c\u043b\u044f <strong>NI PXIe-1095<\/strong> is a high-performance 18-slot PXI Express chassis designed for automated test, semiconductor validation, RF measurement, high-speed data acquisition, hardware-in-the-loop testing and other demanding multichannel applications.<\/p>\n<p>The chassis provides <strong>up to 24 GB\/s of system bandwidth<\/strong>, including high-performance PCI Express Gen 3 connections that can deliver as much as 8 GB\/s of dedicated single-direction bandwidth to supported slots. Its large backplane includes 11 PXI Express peripheral slots, five PXI Express hybrid peripheral slots and one PXI Express system timing slot.<\/p>\n<p>With selectable 38 W, 58 W and 82 W cooling profiles, the PXIe-1095 can support conventional measurement instruments as well as modern high-power FPGA, RF, digitizer and source measure unit modules. The chassis also supports two hot-swappable power supplies, with one power supply included in the standard configuration.<\/p>\n<p>A Timing and Synchronization version adds an oven-controlled crystal oscillator, external clock connections, high-density trigger ports, remote inhibit, chassis monitoring and improved system timing accuracy. This configuration is suitable for synchronized multichannel and multichassis measurement systems.<\/p>\n<h3>Key Features of the PXIe-1095<\/h3>\n<ul>\n<li>18-slot 3U PXI Express chassis<\/li>\n<li>One PXI Express system controller slot<\/li>\n<li>Eleven PXI Express peripheral slots<\/li>\n<li>Five PXI Express hybrid peripheral slots<\/li>\n<li>One PXI Express system timing slot<\/li>\n<li>Up to 24 GB\/s maximum system bandwidth<\/li>\n<li>PCI Express Gen 3 backplane architecture<\/li>\n<li>Up to 8 GB\/s dedicated bandwidth to supported slots<\/li>\n<li>Accepts PXI Express modules in every peripheral position<\/li>\n<li>Supports compatible PXI modules in five hybrid slots<\/li>\n<li>38 W, 58 W and 82 W selectable cooling profiles<\/li>\n<li>82 W per-slot cooling from 0\u00b0C to 40\u00b0C<\/li>\n<li>58 W per-slot cooling from 0\u00b0C to 55\u00b0C<\/li>\n<li>Up to 900 W with one power supply<\/li>\n<li>Up to 1,644 W with two power supplies<\/li>\n<li>Supports two hot-swappable power supplies<\/li>\n<li>Power-supply replacement in less than one minute<\/li>\n<li>Optional high-accuracy OCXO timing architecture<\/li>\n<li>Low-jitter 10 MHz and 100 MHz system reference clocks<\/li>\n<li>PXI trigger bus, PXI star trigger and PXIe differential star triggers<\/li>\n<li>Optional external clock and trigger routing<\/li>\n<li>Remote power inhibit and chassis monitoring<\/li>\n<li>USB 3.0 connection for chassis configuration and monitoring<\/li>\n<li>Suitable for benchtop and 19-inch rack installations<\/li>\n<\/ul>\n<h2>PXIe-1095 Technical Specifications<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Product Model<\/th>\n<td>PXIe-1095<\/td>\n<\/tr>\n<tr>\n<th>Product Type<\/th>\n<td>High-performance PXI Express chassis<\/td>\n<\/tr>\n<tr>\n<th>Chassis Format<\/th>\n<td>3U, 18-slot<\/td>\n<\/tr>\n<tr>\n<th>Total Slot Count<\/th>\n<td>18<\/td>\n<\/tr>\n<tr>\n<th>System Controller Slot<\/th>\n<td>1 PXI Express system slot with three controller expansion positions<\/td>\n<\/tr>\n<tr>\n<th>PXI Express Peripheral Slots<\/th>\n<td>11<\/td>\n<\/tr>\n<tr>\n<th>PXI Express Hybrid Slots<\/th>\n<td>5<\/td>\n<\/tr>\n<tr>\n<th>PXI Express System Timing Slots<\/th>\n<td>1<\/td>\n<\/tr>\n<tr>\n<th>Conventional PXI-Only Slots<\/th>\n<td>0<\/td>\n<\/tr>\n<tr>\n<th>Maximum System Bandwidth<\/th>\n<td>24 \u0413\u0411\/\u0441<\/td>\n<\/tr>\n<tr>\n<th>Maximum Supported Slot Bandwidth<\/th>\n<td>Up to 8 GB\/s dedicated, single direction<\/td>\n<\/tr>\n<tr>\n<th>PCI Express Generation<\/th>\n<td>PCI Express Gen 3<\/td>\n<\/tr>\n<tr>\n<th>Maximum PXI Express Link<\/th>\n<td>x8 Gen 3 PCI Express for supported slots<\/td>\n<\/tr>\n<tr>\n<th>Cooling Profiles<\/th>\n<td>38 W, 58 W and 82 W per slot<\/td>\n<\/tr>\n<tr>\n<th>58 W Cooling Temperature Range<\/th>\n<td>0\u00b0C to 55\u00b0C<\/td>\n<\/tr>\n<tr>\n<th>82 W Cooling Temperature Range<\/th>\n<td>0\u00b0C to 40\u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Module Cooling<\/th>\n<td>Three 210 CFM fans with positive-pressure forced-air cooling<\/td>\n<\/tr>\n<tr>\n<th>Secondary Cooling<\/th>\n<td>One 70 CFM fan<\/td>\n<\/tr>\n<tr>\n<th>Module Airflow Direction<\/th>\n<td>Bottom of module to top of module<\/td>\n<\/tr>\n<tr>\n<th>Module Air Intake<\/th>\n<td>Rear of chassis<\/td>\n<\/tr>\n<tr>\n<th>Module Air Exhaust<\/th>\n<td>Top of chassis<\/td>\n<\/tr>\n<tr>\n<th>Power Supply Type<\/th>\n<td>Universal AC, hot-swappable<\/td>\n<\/tr>\n<tr>\n<th>Installed Power Supplies<\/th>\n<td>One standard; supports two<\/td>\n<\/tr>\n<tr>\n<th>Single-Supply Available Power<\/th>\n<td>900 W<\/td>\n<\/tr>\n<tr>\n<th>Dual-Supply Available Power<\/th>\n<td>1,644 W<\/td>\n<\/tr>\n<tr>\n<th>AC Input Rating<\/th>\n<td>100 VAC to 240 VAC, 50\/60 Hz, 15 A to 7.5 A<\/td>\n<\/tr>\n<tr>\n<th>400 Hz Input Support<\/th>\n<td>100 VAC to 120 VAC, up to 440 Hz<\/td>\n<\/tr>\n<tr>\n<th>Operating Voltage Range<\/th>\n<td>90 VAC to 264 VAC<\/td>\n<\/tr>\n<tr>\n<th>Typical Power-Supply Efficiency<\/th>\n<td>85%<\/td>\n<\/tr>\n<tr>\n<th>Power-Supply Replacement Time<\/th>\n<td>Less than one minute<\/td>\n<\/tr>\n<tr>\n<th>Standard Clock Type<\/th>\n<td>VCXO<\/td>\n<\/tr>\n<tr>\n<th>Timing Option Clock Type<\/th>\n<td>OCXO<\/td>\n<\/tr>\n<tr>\n<th>Standard Reference Clock Accuracy<\/th>\n<td>\u00b125 ppm maximum<\/td>\n<\/tr>\n<tr>\n<th>OCXO Accuracy<\/th>\n<td>\u00b180 ppb maximum within one year of calibration<\/td>\n<\/tr>\n<tr>\n<th>OCXO Long-Term Stability<\/th>\n<td>\u00b150 ppb per year<\/td>\n<\/tr>\n<tr>\n<th>PXI_CLK10 Slot-to-Slot Skew<\/th>\n<td>250 ps maximum<\/td>\n<\/tr>\n<tr>\n<th>PXI_CLK10 Maximum Jitter<\/th>\n<td>5 ps RMS<\/td>\n<\/tr>\n<tr>\n<th>PXIe_CLK100 Slot-to-Slot Skew<\/th>\n<td>100 ps maximum<\/td>\n<\/tr>\n<tr>\n<th>PXIe_CLK100 Maximum Jitter<\/th>\n<td>3 ps RMS from 10 Hz to 12 kHz; 2 ps RMS from 12 kHz to 20 MHz<\/td>\n<\/tr>\n<tr>\n<th>PXI Star Trigger Skew<\/th>\n<td>250 ps maximum<\/td>\n<\/tr>\n<tr>\n<th>PXIe Differential Star Trigger Skew<\/th>\n<td>150 ps maximum slot-to-slot<\/td>\n<\/tr>\n<tr>\n<th>External Clocking<\/th>\n<td>Available with Timing and Synchronization option<\/td>\n<\/tr>\n<tr>\n<th>External Trigger Access<\/th>\n<td>Available with Timing and Synchronization option<\/td>\n<\/tr>\n<tr>\n<th>Operating Temperature<\/th>\n<td>0\u00b0C to 55\u00b0C with modules requiring no more than 58 W per slot<\/td>\n<\/tr>\n<tr>\n<th>Storage Temperature<\/th>\n<td>\u221240\u00b0C to 71\u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Operating Humidity<\/th>\n<td>10% to 90%, noncondensing<\/td>\n<\/tr>\n<tr>\n<th>Maximum Operating Altitude<\/th>\n<td>4,600 m at 25\u00b0C in High fan mode<\/td>\n<\/tr>\n<tr>\n<th>Operational Shock<\/th>\n<td>30 g peak, half-sine, 11 ms<\/td>\n<\/tr>\n<tr>\n<th>Operational Random Vibration<\/th>\n<td>5 Hz to 500 Hz, 0.3 grms<\/td>\n<\/tr>\n<tr>\n<th>Dimensions<\/th>\n<td>177.1 mm \u00d7 445.5 mm \u00d7 463.6 mm (6.97 in. \u00d7 17.54 in. \u00d7 18.25 in.)<\/td>\n<\/tr>\n<tr>\n<th>Weight with One Power Supply<\/th>\n<td>16.0 kg (35.2 lb)<\/td>\n<\/tr>\n<tr>\n<th>Weight with Two Power Supplies<\/th>\n<td>17.7 kg (39.0 lb)<\/td>\n<\/tr>\n<tr>\n<th>Configuration Software<\/th>\n<td>NI Measurement &amp; Automation Explorer and PXI Platform Services<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The stated bandwidth is the theoretical capability of the chassis backplane. Actual application throughput depends on the selected controller, module link width, DMA implementation, driver, memory architecture, processor and storage system.<\/p>\n<p>The 82 W rating applies to the chassis cooling capability and does not mean that every configuration can automatically power 82 W in all slots simultaneously. Total power-supply capacity, individual voltage-rail limits and module cooling requirements must be calculated together.<\/p>\n<h2>PXIe-1095 Part Number and Accessories<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Item<\/th>\n<th>Part Number<\/th>\n<th>\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435<\/th>\n<\/tr>\n<tr>\n<td>PXIe-1095 Standard Chassis<\/td>\n<td>783882-01<\/td>\n<td>18-slot, 24 GB\/s PXI Express chassis with standard VCXO timing<\/td>\n<\/tr>\n<tr>\n<td>PXIe-1095 with Timing and Synchronization<\/td>\n<td>785971-01<\/td>\n<td>18-slot chassis with OCXO, external clocking, trigger routing and chassis monitoring connections<\/td>\n<\/tr>\n<tr>\n<td>PXIe-1095 AC\/DC Power Supply<\/td>\n<td>786300-01<\/td>\n<td>900 W hot-swappable power supply for single- or dual-supply configurations<\/td>\n<\/tr>\n<tr>\n<td>DB-to-BNC Breakout Trigger Cable<\/td>\n<td>149055-0R2<\/td>\n<td>20 cm cable providing six BNC connections for PFI 0\u20133, remote inhibit and fault signals<\/td>\n<\/tr>\n<tr>\n<td>HDMI-to-HDMI Trigger Cable<\/td>\n<td>148864-01<\/td>\n<td>1 m cable for compatible trigger-routing connections<\/td>\n<\/tr>\n<tr>\n<td>U.S. IEC Power Cord<\/td>\n<td>763830-01<\/td>\n<td>125 VAC, 15 A AC power cord<\/td>\n<\/tr>\n<tr>\n<td>China IEC Power Cord<\/td>\n<td>784686-01<\/td>\n<td>250 V, 10 A AC power cord for China<\/td>\n<\/tr>\n<tr>\n<td>Japan IEC Power Cord<\/td>\n<td>786377-01<\/td>\n<td>125 VAC, 12 A AC power cord for Japan<\/td>\n<\/tr>\n<tr>\n<td>European IEC Power Cord<\/td>\n<td>763067-01<\/td>\n<td>240 V, 10 A right-angle AC power cord<\/td>\n<\/tr>\n<tr>\n<td>PXI EMC Filler Panels<\/td>\n<td>Included with chassis<\/td>\n<td>Seven single-slot, one double-slot and two quadruple-slot filler panels<\/td>\n<\/tr>\n<tr>\n<td>Second Power Supply<\/td>\n<td>Optional<\/td>\n<td>Increases available chassis power and provides a serviceable dual-supply configuration<\/td>\n<\/tr>\n<tr>\n<td>PXIe-1095 Rack-Mount Kit<\/td>\n<td>Configuration dependent<\/td>\n<td>Hardware for installing the chassis in a compatible 19-inch equipment rack<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The standard <strong>783882-01<\/strong> configuration uses a VCXO and does not provide integrated external clock or trigger access. The <strong>785971-01<\/strong> Timing and Synchronization version adds an OCXO, rear-panel reference clock connections, high-density trigger connections, remote inhibit and chassis-monitoring features.<\/p>\n<p>Both versions support two hot-swappable power supplies. One supply is included with the chassis; a second compatible power supply can be installed when the system requires additional power capacity or improved serviceability.<\/p>\n<h3>18-Slot PXI Express Architecture<\/h3>\n<p>The PXIe-1095 provides one system controller slot and 17 peripheral positions. The peripheral positions consist of 11 dedicated PXI Express slots, five PXI Express hybrid slots and one PXI Express system timing slot.<\/p>\n<p>This configuration provides enough capacity to combine digitizers, waveform generators, RF instruments, source measure units, switching modules, FPGA devices and communication interfaces in a single chassis.<\/p>\n<p>The controller position also provides three adjacent system expansion positions. These positions accommodate wider embedded controllers or system devices that require more than one physical slot.<\/p>\n<h3>Eleven PXI Express Peripheral Slots<\/h3>\n<p>The 11 dedicated PXI Express peripheral positions accept compatible PXI Express instruments. These slots are appropriate for digitizers, RF analyzers, waveform generators, FlexRIO devices and other modules that require PCI Express data transfer.<\/p>\n<p>PXI Express modules cannot be installed in conventional PXI-only chassis positions. The PXIe-1095 avoids this limitation by providing a PCI Express connection to every peripheral position.<\/p>\n<h3>Five PXI Express Hybrid Slots<\/h3>\n<p>The five hybrid slots accept PXI Express modules and supported PXI hybrid-compatible instruments. This allows a system to combine current PXIe hardware with selected conventional PXI switch, measurement and communication modules.<\/p>\n<p>Not every older PXI module is compatible with a hybrid slot. Modules with incompatible connector features or unsupported local-bus requirements must be checked against the module documentation before installation.<\/p>\n<h3>PXI Express System Timing Slot<\/h3>\n<p>The PXI Express system timing slot provides dedicated clock and trigger connections to the peripheral slots. A compatible timing module can replace, discipline or redistribute the chassis reference clocks and generate precisely aligned trigger signals.<\/p>\n<p>This position is valuable in phase-coherent RF systems, synchronized digitizer arrays, multichannel waveform generation and multichassis data-acquisition applications.<\/p>\n<p>If dedicated system timing functionality is not required, the position can support compatible PXI Express peripheral modules according to the applicable hardware documentation.<\/p>\n<h3>24 GB\/s System Bandwidth<\/h3>\n<p>The PXIe-1095 backplane provides up to 24 GB\/s of aggregate system bandwidth. Its PCI Express Gen 3 architecture supports high-speed data movement between the controller and installed instruments.<\/p>\n<p>Supported peripheral positions can receive up to 8 GB\/s of dedicated single-direction bandwidth through x8 Gen 3 PCI Express links. This is particularly useful for high-channel-count digitizers, FPGA coprocessing, peer-to-peer streaming and wideband RF acquisition.<\/p>\n<p>Modules that require less bandwidth remain compatible, but their transfer rate is limited by the module interface and assigned PCI Express link. A complete system design should map the highest-throughput instruments to the most appropriate backplane positions.<\/p>\n<h3>Peer-to-Peer Data Streaming<\/h3>\n<p>Compatible PXI Express instruments can transfer data through the backplane without routing every sample through the host processor. Peer-to-peer streaming can reduce CPU loading and improve latency in FPGA, RF and real-time signal-processing applications.<\/p>\n<p>Actual peer-to-peer support depends on the installed modules, controller, drivers and application software. Confirm that all selected devices support the required streaming architecture.<\/p>\n<h3>82 W Per-Slot Cooling<\/h3>\n<p>The PXIe-1095 provides selectable cooling profiles for modules with different thermal requirements. The 38 W profile supports conventional PXI Express instruments while reducing acoustic noise when maximum fan performance is unnecessary.<\/p>\n<p>The 58 W profile supports modules dissipating up to 58 W per slot across the chassis\u2019s 0\u00b0C to 55\u00b0C operating-temperature range. The 82 W profile supports modules dissipating up to 82 W per slot from 0\u00b0C to 40\u00b0C.<\/p>\n<p>The higher profile is useful for high-performance FPGA, RF and power instruments. When any installed module requires more than 58 W of cooling, the maximum permitted ambient temperature is reduced to 40\u00b0C.<\/p>\n<h3>Advanced Chassis Cooling Design<\/h3>\n<p>Three 210 CFM fans provide positive-pressure cooling for the controller and peripheral modules. Air enters through the rear of the chassis, travels from the bottom to the top of each module and exits through the top enclosure vents.<\/p>\n<p>A separate 70 CFM fan provides secondary cooling. Each power supply also includes dedicated fans, and the Timing and Synchronization hardware uses an additional controlled airflow path.<\/p>\n<p>The chassis requires at least 101.6 mm of rear clearance and 44.45 mm of clearance above and on each side. Blocking these areas can increase internal temperature and reduce the available cooling margin.<\/p>\n<h3>Cooling Profile Selection<\/h3>\n<p>PXI Platform Services can determine the cooling requirements of supported NI modules and optimize chassis fan operation. Cooling profiles that cannot meet the installed module requirements may be disabled automatically.<\/p>\n<p>The selected profile should always support the highest-power instrument in the system. Reducing fan speed to decrease noise is not appropriate when doing so would violate a module\u2019s required cooling capacity.<\/p>\n<h3>Acoustic Performance<\/h3>\n<p>In the 38 W profile and Auto fan mode, the chassis can operate at approximately 37.7 dBA sound pressure at ambient temperatures up to 30\u00b0C. This setting is suitable for laboratories and engineering workspaces where acoustic noise is important.<\/p>\n<p>The 58 W\/82 W cooling profile produces higher fan noise because it must move more air through the modules. In Auto mode, the sound pressure is approximately 52.1 dBA at ambient temperatures up to 30\u00b0C.<\/p>\n<p>High fan mode provides maximum airflow and is best suited to production racks, high-power configurations and elevated-temperature environments.<\/p>\n<h3>900 W Single-Power-Supply Operation<\/h3>\n<p>A standard PXIe-1095 includes one 900 W AC\/DC power supply. The supply accepts a wide input-voltage range and provides power to the chassis controller, backplane and installed instruments.<\/p>\n<p>The power supply includes protection against short circuits, overload and overvoltage conditions. Automatic recovery allows the outputs to resume operation after a qualifying overload condition has been removed.<\/p>\n<h3>Dual Hot-Swappable Power Supplies<\/h3>\n<p>A second 900 W supply can be installed to increase the maximum available chassis power to 1,644 W. This additional capacity is useful when many high-power modules are operated simultaneously.<\/p>\n<p>The supplies are hot-swappable, allowing a failed or serviceable power supply to be replaced without disassembling the complete chassis. NI specifies a power-supply replacement time of less than one minute.<\/p>\n<p>Dual supplies increase power capacity and maintainability, but the system designer must confirm whether the application\u2019s actual load permits operation during the removal or failure of one supply. Dual installation should not automatically be interpreted as unconditional full-load redundancy.<\/p>\n<h3>Standard VCXO Reference Clock<\/h3>\n<p>The standard PXIe-1095 uses a voltage-controlled crystal oscillator with specified reference-clock accuracy of \u00b125 ppm. The chassis distributes a low-jitter 10 MHz clock and a differential 100 MHz clock to compatible modules.<\/p>\n<p>The 10 MHz PXI_CLK10 signal provides maximum slot-to-slot skew of 250 ps and maximum phase jitter of 5 ps RMS. PXIe_CLK100 provides maximum slot-to-slot skew of 100 ps.<\/p>\n<h3>Optional OCXO Timing<\/h3>\n<p>The Timing and Synchronization version uses an oven-controlled crystal oscillator to provide improved clock accuracy and long-term stability. Within one year of calibration, the specified OCXO accuracy is \u00b180 ppb after the required warm-up period.<\/p>\n<p>The OCXO version is beneficial for frequency measurements, RF generation and analysis, phase-coherent acquisition and tests requiring reduced reference-clock drift.<\/p>\n<p>The OCXO requires warm-up time to reach its specified accuracy. NI\u2019s calibration procedure specifies continuous operation before precision verification or adjustment.<\/p>\n<h3>PXI and PXI Express Triggering<\/h3>\n<p>The PXIe-1095 provides the standard eight-line PXI trigger bus, PXI star trigger and PXI Express differential star trigger resources. These backplane connections allow instruments to coordinate acquisition, generation and control operations.<\/p>\n<p>PXI star triggering provides maximum slot-to-slot skew of 250 ps. The differential PXIe-DSTAR connections provide maximum slot-to-slot skew of 150 ps and maximum differential skew of 25 ps.<\/p>\n<h3>Timing and Synchronization Connections<\/h3>\n<p>The Timing and Synchronization configuration provides rear-panel 10 MHz reference input and output, high-density trigger connections and programmable function interface lines.<\/p>\n<p>The external 10 MHz reference output has specified temperature accuracy of \u00b15 ppb and an aging rate of \u00b150 ppb per year. These connections can be used to coordinate the PXIe-1095 with compatible laboratory references or additional PXI chassis.<\/p>\n<h3>Remote Inhibit and Chassis Monitoring<\/h3>\n<p>The Timing and Synchronization configuration provides remote power-inhibit and chassis-monitoring signals. Remote inhibit can be integrated into a rack-level safety system, emergency shutdown circuit or facility-control architecture.<\/p>\n<p>Fault and monitoring signals can be accessed using the compatible DB-to-BNC breakout cable. The interface should be wired according to the official pinout and logic-level specifications.<\/p>\n<h3>USB 3.0 Chassis Connection<\/h3>\n<p>A rear-panel USB 3.0 port supports chassis communication and configuration functions. PXI Platform Services and NI Measurement &amp; Automation Explorer can be used to identify the chassis and review supported status or configuration information.<\/p>\n<p>The USB connection does not replace the PXI Express system controller. Measurement data from installed instruments is transferred through the controller and chassis backplane.<\/p>\n<h3>Rack-Mount Integration<\/h3>\n<p>The 17.54-inch chassis width is designed for installation in a standard 19-inch equipment rack using compatible rack-mount hardware. Its 18-slot architecture is suitable for large automated test installations where many instruments must be centrally integrated.<\/p>\n<p>The rack must provide sufficient structural support, cooling clearance and cable management. Because the chassis weighs as much as 17.7 kg with two supplies before instruments are installed, appropriate lifting and mounting procedures are required.<\/p>\n<h2>PXIe-1095 Applications<\/h2>\n<ul>\n<li>Semiconductor characterization and production testing<\/li>\n<li>High-channel-count automated test equipment<\/li>\n<li>RF and wireless device validation<\/li>\n<li>Radar and electronic-warfare testing<\/li>\n<li>High-speed oscilloscope and digitizer systems<\/li>\n<li>Wideband signal generation and analysis<\/li>\n<li>FPGA-based real-time signal processing<\/li>\n<li>\u0421\u0438\u043c\u0443\u043b\u044f\u0446\u0438\u044f \u0441 \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u044b\u043c \u0432\u0445\u043e\u0434\u043e\u043c<\/li>\n<li>Automotive ECU and powertrain testing<\/li>\n<li>Aerospace and defense validation<\/li>\n<li>Electronic power and battery testing<\/li>\n<li>Multichannel synchronized data acquisition<\/li>\n<li>Peer-to-peer instrument streaming<\/li>\n<li>Production functional testing<\/li>\n<li>Research and laboratory automation<\/li>\n<\/ul>\n<h3>\u0421\u0438\u0441\u0442\u0435\u043c\u044b \u0442\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f \u043f\u043e\u043b\u0443\u043f\u0440\u043e\u0432\u043e\u0434\u043d\u0438\u043a\u043e\u0432<\/h3>\n<p>The PXIe-1095 can host source measure units, digital pattern instruments, waveform generators, digitizers, power supplies and switching modules in a single high-density platform.<\/p>\n<p>Its high-power and cooling capacity supports modules used for parametric test, mixed-signal validation, device characterization and production test. The 24 GB\/s backplane helps move measurement data between instruments and the controller efficiently.<\/p>\n<h3>RF and Wireless Validation<\/h3>\n<p>Wideband RF test systems can combine vector signal transceivers, RF signal generators, analyzers, digitizers and RF switches inside the PXIe-1095.<\/p>\n<p>The high-bandwidth backplane supports waveform transfer and real-time processing, while the optional OCXO and external clock connections help maintain frequency alignment between instruments.<\/p>\n<h3>Radar and Electronic-Warfare Testing<\/h3>\n<p>Radar and electronic-warfare applications often require wide instantaneous bandwidth, low-latency FPGA processing and coordinated generation and acquisition across several instruments.<\/p>\n<p>The chassis\u2019s Gen 3 backplane, system timing slot and high cooling capacity support these demanding configurations. Peer-to-peer transfers can move waveform data directly between compatible FPGA, digitizer and RF modules.<\/p>\n<h3>High-Speed Data Acquisition<\/h3>\n<p>Multiple high-speed digitizers can be installed for transient capture, physics research, component validation and multichannel waveform recording.<\/p>\n<p>For sustained acquisition, the controller, memory, software buffers and storage array must be able to accept the combined data rate. Backplane bandwidth alone does not guarantee uninterrupted disk recording.<\/p>\n<h3>Hardware-in-the-Loop Testing<\/h3>\n<p>The PXIe-1095 can integrate FPGA modules, analog I\/O, digital I\/O, communication interfaces, fault-insertion switches and real-time controllers for HIL validation.<\/p>\n<p>The large slot count allows engineers to simulate many ECU signals in one system. Hardware clocks and triggers can coordinate simulation models, stimulus generation and response acquisition.<\/p>\n<h3>Electronic Power Testing<\/h3>\n<p>The 82 W cooling profile and dual-power-supply capacity support configurations containing high-power source measure units, programmable supplies and electronic loads.<\/p>\n<p>Total power, rail current, module dissipation and rack temperature must be checked carefully. High-power instruments may also require additional wiring, safety barriers and fixture-level protection.<\/p>\n<h3>Multichannel Synchronized Measurement<\/h3>\n<p>The system timing slot and PXIe differential star triggers support synchronization across large groups of compatible instruments. This is valuable for phase measurements, acoustic arrays, vibration analysis and multichannel RF systems.<\/p>\n<p>The Timing and Synchronization configuration can further improve reference-clock stability and provide external signal access for multichassis systems.<\/p>\n<h2>PXIe-1095 Installation Workflow<\/h2>\n<h4>Step 1: Inspect the Chassis and Included Components<\/h4>\n<p>Inspect the enclosure, backplane connectors, power-supply bay, fans, air intake and rack-mounting points. Confirm that the required filler panels and regulatory documentation are included.<\/p>\n<p>Do not power or install modules in a chassis that shows evidence of impact damage, bent backplane connectors, liquid contamination or damaged AC components.<\/p>\n<h4>Step 2: Prepare the Installation Environment<\/h4>\n<p>Place the chassis on a stable surface or install it in a properly supported 19-inch equipment rack. Account for the chassis weight plus the weight of the controller, instruments, power supplies and front-panel cables.<\/p>\n<h5>Rear Clearance<\/h5>\n<p>Provide at least 101.6 mm of clearance behind the chassis for module cooling air, power connections and cable access.<\/p>\n<h5>Top Clearance<\/h5>\n<p>Provide at least 44.45 mm above the chassis because the primary module and power-supply exhaust vents are located on the top.<\/p>\n<h5>Side Clearance<\/h5>\n<p>Provide at least 44.45 mm on each side to support secondary cooling and the Timing and Synchronization airflow path.<\/p>\n<h4>Step 3: Connect Protective Earth<\/h4>\n<p>Connect the chassis to a properly grounded AC supply. Where required by the facility installation or 400 Hz dual-supply operation, connect the rear protective-earth terminal using correctly rated grounding hardware.<\/p>\n<p>Do not use an adapter that defeats the protective-earth conductor. Both AC power cords must be disconnected to remove all power from a dual-supply chassis.<\/p>\n<h4>Step 4: Plan the Slot Assignment<\/h4>\n<p>Create a slot map before installing hardware. Consider PCI Express bandwidth, module compatibility, cooling profile, power consumption, timing resources, controller width and cable clearance.<\/p>\n<h5>Controller Position<\/h5>\n<p>Install the PXI Express embedded controller or remote-control interface in the system controller slot. Reserve the adjacent expansion positions when the controller requires additional width.<\/p>\n<h5>High-Bandwidth Positions<\/h5>\n<p>Assign digitizers, FPGA devices and RF instruments to slots that provide the PCI Express link width required by each module.<\/p>\n<h5>Hybrid Positions<\/h5>\n<p>Use the five hybrid slots for supported conventional PXI instruments or PXI Express modules. Confirm hybrid compatibility before installing an older PXI device.<\/p>\n<h5>System Timing Position<\/h5>\n<p>Install a compatible timing module in the system timing slot when dedicated clock or differential star-trigger control is required.<\/p>\n<h4>Step 5: Calculate the Power Budget<\/h4>\n<p>Add the maximum power consumption of the controller and all peripheral modules. Check the total against the 900 W single-supply or 1,644 W dual-supply capacity.<\/p>\n<p>Also verify the current required from the +12 V, +5 V, +3.3 V, \u221212 V and auxiliary rails. Remaining below the total wattage rating does not guarantee that every rail remains within its current limit.<\/p>\n<h4>Step 6: Select the Cooling Profile<\/h4>\n<p>Select the 38 W, 58 W or 82 W profile according to the highest cooling requirement among the installed modules.<\/p>\n<p>Use the 58 W profile for operation up to 55\u00b0C when all modules dissipate 58 W or less. If any module requires more than 58 W and up to 82 W, keep the ambient temperature between 0\u00b0C and 40\u00b0C.<\/p>\n<h4>Step 7: Install the Controller and Instruments<\/h4>\n<p>Turn off the chassis and disconnect external signals before installing modules. Use appropriate electrostatic-discharge protection.<\/p>\n<p>Align each module with the upper and lower guides, slide it evenly toward the backplane and use the injector\/ejector handle to fully engage the connectors. Tighten the module retaining screws.<\/p>\n<h4>Step 8: Install Filler Panels<\/h4>\n<p>Cover all unused positions with the supplied filler panels. Filler panels maintain positive air pressure, direct cooling through the installed modules and support electromagnetic-compliance performance.<\/p>\n<h4>Step 9: Install the Second Power Supply if Required<\/h4>\n<p>Install the second compatible supply when the calculated system load exceeds the single-supply capacity or when the maintenance strategy requires a dual-supply configuration.<\/p>\n<p>For high-power configurations, confirm that the facility branch circuit can support the required current. Separate branch circuits may be necessary for two heavily loaded supplies.<\/p>\n<h4>Step 10: Connect Timing and Trigger Cables<\/h4>\n<p>For the Timing and Synchronization configuration, connect the external reference clock, trigger-routing cables and remote-inhibit signals according to the system timing diagram.<\/p>\n<p>Use 50 \u03a9 clock cabling and suitable termination. Do not connect TTL or other incompatible signals to reference outputs that use a different specified amplitude or impedance.<\/p>\n<h4>Step 11: Power On and Configure the Chassis<\/h4>\n<p>Apply AC power and turn on the chassis. Confirm normal power-supply, temperature and fan indications before starting the controller.<\/p>\n<p>Open NI Measurement &amp; Automation Explorer and verify the chassis model, controller, installed modules and assigned slot positions.<\/p>\n<h4>Step 12: Validate the Complete System<\/h4>\n<p>Run instrument self-tests, verify clock-lock status and test the required trigger routes. Execute a representative data-transfer test to confirm that the controller and storage system meet the expected throughput.<\/p>\n<p>Monitor chassis temperature, fan operation and power status during the initial full-load test before releasing the system for unattended use.<\/p>\n<h2>PXIe-1095 Troubleshooting<\/h2>\n<h4>Chassis Power Problems<\/h4>\n<h5>The chassis does not power on<\/h5>\n<p>Verify the AC source, power cord, branch-circuit capacity and front-panel power-inhibit setting. On the Timing and Synchronization model, confirm that the remote-inhibit signal is not preventing startup.<\/p>\n<h5>One power supply does not operate<\/h5>\n<p>Check the rear-panel supply indicator and AC input connection. Confirm that the power supply is fully seated and that both supplies are compatible with the PXIe-1095.<\/p>\n<h5>The chassis shuts down under load<\/h5>\n<p>Review total system power and individual voltage-rail current. Remove nonessential modules and test again. A high-power dual-supply system may require separate facility branch circuits.<\/p>\n<h4>Module Detection Problems<\/h4>\n<h5>A module is missing in NI MAX<\/h5>\n<p>Power off the system and make sure the module is installed in a compatible slot and fully engaged with the backplane. Check the required instrument driver and refresh the NI MAX hardware list.<\/p>\n<h5>A conventional PXI module does not fit<\/h5>\n<p>The PXIe-1095 has five hybrid positions but no dedicated PXI-only slots. Confirm that the module supports installation in a PXI Express hybrid slot.<\/p>\n<h5>A PXI Express module operates at reduced bandwidth<\/h5>\n<p>Check the module\u2019s PCI Express link requirements and the backplane link assigned to its slot. Move high-throughput instruments to the appropriate positions when the system slot map permits.<\/p>\n<h4>Cooling Problems<\/h4>\n<h5>A module reports excessive temperature<\/h5>\n<p>Verify that the selected cooling profile meets the module requirement. Inspect the rear intake, top exhaust, side vents and filler panels. Switch to the appropriate high-performance fan setting when necessary.<\/p>\n<h5>The chassis fans are unusually loud<\/h5>\n<p>Higher cooling profiles intentionally increase fan speed. Check whether the installed modules require the 58 W\/82 W profile and verify that high intake temperature is not causing the automatic fan controller to increase airflow.<\/p>\n<h5>A chassis fan reports a fault<\/h5>\n<p>Stop high-power operation and inspect the corresponding fan module. Continuing operation without adequate forced-air cooling can cause instruments to exceed their permitted temperature.<\/p>\n<h4>Bandwidth Problems<\/h4>\n<h5>Data transfer is lower than 24 GB\/s<\/h5>\n<p>The 24 GB\/s value is an aggregate theoretical backplane rating. Actual throughput depends on the controller, slot link, instrument, DMA configuration, software and destination storage system.<\/p>\n<h5>Streaming stops during long acquisitions<\/h5>\n<p>Check host memory, DMA buffer size, processor utilization and disk write speed. Use a suitable RAID or NVMe storage architecture when continuous data exceeds the capability of a single storage device.<\/p>\n<h5>Peer-to-peer transfer does not work<\/h5>\n<p>Confirm that both modules, the selected slots, installed drivers and application software support peer-to-peer streaming. Standard host-based transfers do not automatically become peer-to-peer operations.<\/p>\n<h4>Clock and Trigger Problems<\/h4>\n<h5>The external reference does not lock<\/h5>\n<p>Verify the reference frequency, amplitude, connector, impedance and termination. Make sure the signal is connected to the reference input and not the reference output.<\/p>\n<h5>Instruments drift apart over time<\/h5>\n<p>Confirm that every instrument uses the same chassis or external reference. A shared frequency reference reduces clock drift but does not automatically align the start time of separate acquisitions.<\/p>\n<h5>Trigger timing is inconsistent<\/h5>\n<p>Use backplane star or differential star triggers when low skew is required. Review the trigger route, timing-slot configuration and individual module trigger capabilities.<\/p>\n<h4>Communication Problems<\/h4>\n<h5>The external host cannot detect the chassis<\/h5>\n<p>Check the PXI Express remote-control interface, host adapter and connecting cable. Follow the required system power-on sequence and confirm operating-system and driver support.<\/p>\n<h5>The chassis USB connection is unavailable<\/h5>\n<p>Inspect the USB cable and host port, then verify the installed PXI Platform Services version. The chassis USB connection is used for chassis services and does not replace the system controller connection.<\/p>\n<h2>PXIe-1095 Comparison<\/h2>\n<h3>PXIe-1095 vs PXIe-1092<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u0424\u0443\u043d\u043a\u0446\u0438\u044f<\/th>\n<th>PXIe-1095<\/th>\n<th><a href=\"https:\/\/pxisource.com\/ru\/product\/pxie-1092\/\">PXIe-1092<\/a><\/th>\n<\/tr>\n<tr>\n<td>\u041e\u0431\u0449\u0435\u0435 \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u0441\u043b\u043e\u0442\u043e\u0432<\/td>\n<td>18<\/td>\n<td>10<\/td>\n<\/tr>\n<tr>\n<td>Maximum System Bandwidth<\/td>\n<td>24 \u0413\u0411\/\u0441<\/td>\n<td>24 \u0413\u0411\/\u0441<\/td>\n<\/tr>\n<tr>\n<td>Maximum Cooling<\/td>\n<td>82 \u0412\u0442 \u043d\u0430 \u0441\u043b\u043e\u0442<\/td>\n<td>82 \u0412\u0442 \u043d\u0430 \u0441\u043b\u043e\u0442<\/td>\n<\/tr>\n<tr>\n<td>\u0413\u0438\u0431\u0440\u0438\u0434\u043d\u044b\u0435 \u0441\u043b\u043e\u0442\u044b<\/td>\n<td>5<\/td>\n<td>7<\/td>\n<\/tr>\n<tr>\n<td>Power-Supply Architecture<\/td>\n<td>Supports two hot-swappable supplies<\/td>\n<td>Lower-capacity chassis architecture<\/td>\n<\/tr>\n<tr>\n<td>Best Suited For<\/td>\n<td>Large, high-channel-count systems<\/td>\n<td>Compact high-performance systems<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Choose the PXIe-1095 when the application requires maximum slot capacity, many simultaneous instruments or dual hot-swappable power supplies. Choose the PXIe-1092 when comparable backplane performance is required in a smaller chassis.<\/p>\n<h3>PXIe-1095 vs PXIe-1085<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u0424\u0443\u043d\u043a\u0446\u0438\u044f<\/th>\n<th>PXIe-1095<\/th>\n<th><a href=\"https:\/\/pxisource.com\/ru\/product\/pxie-1085\/\">PXIe-1085<\/a><\/th>\n<\/tr>\n<tr>\n<td>\u041e\u0431\u0449\u0435\u0435 \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u0441\u043b\u043e\u0442\u043e\u0432<\/td>\n<td>18<\/td>\n<td>18<\/td>\n<\/tr>\n<tr>\n<td>Maximum System Bandwidth<\/td>\n<td>24 \u0413\u0411\/\u0441<\/td>\n<td>Up to 24 GB\/s, configuration dependent<\/td>\n<\/tr>\n<tr>\n<td>Maximum Per-Slot Cooling<\/td>\n<td>82 \u0412\u0442<\/td>\n<td>Lower than the PXIe-1095 maximum profile<\/td>\n<\/tr>\n<tr>\n<td>Hot-Swappable Dual Supplies<\/td>\n<td>Supported<\/td>\n<td>Different power-supply architecture<\/td>\n<\/tr>\n<tr>\n<td>Optional OCXO Timing<\/td>\n<td>Available<\/td>\n<td>Configuration dependent<\/td>\n<\/tr>\n<tr>\n<td>Best Suited For<\/td>\n<td>High-power, high-density modern systems<\/td>\n<td>Established 18-slot PXIe systems<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The PXIe-1095 is designed for applications requiring increased per-slot power and cooling. The PXIe-1085 remains suitable when the installed modules do not require the PXIe-1095\u2019s 82 W thermal profile.<\/p>\n<h3>PXIe-1095 vs PXIe-1095 Timing and Synchronization<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u0424\u0443\u043d\u043a\u0446\u0438\u044f<\/th>\n<th>Standard PXIe-1095<\/th>\n<th>Timing and Synchronization Version<\/th>\n<\/tr>\n<tr>\n<td>Part Number<\/td>\n<td>783882-01<\/td>\n<td>785971-01<\/td>\n<\/tr>\n<tr>\n<td>Oscillator<\/td>\n<td>VCXO<\/td>\n<td>OCXO<\/td>\n<\/tr>\n<tr>\n<td>Clock Accuracy<\/td>\n<td>\u00b125 ppm<\/td>\n<td>\u00b180 ppb within one year of calibration<\/td>\n<\/tr>\n<tr>\n<td>External Clock Access<\/td>\n<td>No integrated access<\/td>\n<td>\u0414\u0430<\/td>\n<\/tr>\n<tr>\n<td>External Trigger Access<\/td>\n<td>No integrated access<\/td>\n<td>\u0414\u0430<\/td>\n<\/tr>\n<tr>\n<td>Remote Inhibit and Monitoring<\/td>\n<td>Limited standard controls<\/td>\n<td>Rear-panel interface provided<\/td>\n<\/tr>\n<tr>\n<td>Best Suited For<\/td>\n<td>General automated test<\/td>\n<td>Precision timing and multichassis synchronization<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Selecting the Right PXI Express Chassis<\/h3>\n<p>Choose the PXIe-1095 when the test system requires 18 slots, up to 24 GB\/s of backplane bandwidth, high-power modules, 82 W cooling or dual hot-swappable power supplies.<\/p>\n<p>Select the Timing and Synchronization version when the system requires an OCXO, external reference-clock access, rear-panel trigger connections or remote chassis monitoring.<\/p>\n<p>Consider the PXIe-1092 when a smaller ten-slot chassis provides sufficient capacity. Consider a lower-power 18-slot chassis when the installed modules do not require the PXIe-1095\u2019s advanced cooling and power architecture.<\/p>\n<h3>Why Choose the PXIe-1095?<\/h3>\n<ul>\n<li>Provides 18 slots for large PXI Express systems<\/li>\n<li>Accepts PXI Express modules in every peripheral position<\/li>\n<li>Supports compatible PXI instruments in five hybrid slots<\/li>\n<li>Delivers up to 24 GB\/s of system bandwidth<\/li>\n<li>Supports up to 8 GB\/s dedicated slot bandwidth<\/li>\n<li>Provides as much as 82 W of cooling per slot<\/li>\n<li>Supports two hot-swappable power supplies<\/li>\n<li>Provides up to 1,644 W with dual supplies<\/li>\n<li>Offers an optional high-accuracy OCXO<\/li>\n<li>Supports low-skew differential star triggering<\/li>\n<li>Provides external clock and trigger routing options<\/li>\n<li>Supports remote inhibit and chassis monitoring<\/li>\n<li>Suitable for high-density laboratory and production systems<\/li>\n<\/ul>\n<h2>PXIe-1095 Frequently Asked Questions<\/h2>\n<h4>What is the PXIe-1095?<\/h4>\n<p>The PXIe-1095 is an 18-slot, high-bandwidth PXI Express chassis designed for large automated test and measurement systems.<\/p>\n<h4>How many peripheral slots does the PXIe-1095 provide?<\/h4>\n<p>The chassis provides 17 peripheral positions: 11 PXI Express peripheral slots, five PXI Express hybrid slots and one PXI Express system timing slot.<\/p>\n<h4>What is the maximum system bandwidth?<\/h4>\n<p>The PXIe-1095 provides up to 24 GB\/s of theoretical aggregate system bandwidth.<\/p>\n<h4>What is the maximum bandwidth per slot?<\/h4>\n<p>Supported positions can provide up to 8 GB\/s of dedicated single-direction bandwidth through an x8 PCI Express Gen 3 link.<\/p>\n<h4>Can conventional PXI modules be installed?<\/h4>\n<p>Yes. Up to five compatible conventional PXI modules can be installed in the hybrid peripheral slots. The modules must support PXI Express hybrid-slot installation.<\/p>\n<h4>Does the chassis have PXI-only slots?<\/h4>\n<p>No. The PXIe-1095 has no dedicated PXI-only peripheral slots. Its conventional PXI compatibility is provided through the five hybrid positions.<\/p>\n<h4>What is the maximum cooling capacity?<\/h4>\n<p>The chassis supports up to 82 W of cooling per slot from 0\u00b0C to 40\u00b0C. It supports 58 W per slot across the broader 0\u00b0C to 55\u00b0C operating range.<\/p>\n<h4>How much power does the PXIe-1095 provide?<\/h4>\n<p>One power supply provides up to 900 W. Installing two compatible supplies increases the maximum available chassis power to 1,644 W.<\/p>\n<h4>Are the power supplies hot-swappable?<\/h4>\n<p>Yes. The PXIe-1095 supports two hot-swappable supplies, and NI specifies replacement in less than one minute.<\/p>\n<h4>Does the standard chassis include two power supplies?<\/h4>\n<p>No. One power supply is included. A second compatible power supply can be purchased and installed separately.<\/p>\n<h4>Does the PXIe-1095 provide redundant power?<\/h4>\n<p>It supports a dual hot-swappable power-supply architecture. Whether the system can continue operating after one supply is removed depends on the total installed load and available single-supply capacity.<\/p>\n<h4>What is the difference between the two PXIe-1095 part numbers?<\/h4>\n<p>Part number <strong>783882-01<\/strong> identifies the standard VCXO chassis. Part number <strong>785971-01<\/strong> adds the Timing and Synchronization option with an OCXO and external clock, trigger and monitoring connections.<\/p>\n<h4>What is the OCXO accuracy?<\/h4>\n<p>The Timing and Synchronization version specifies \u00b180 ppb maximum accuracy within one year of calibration after the required operating and warm-up conditions are met.<\/p>\n<h4>Can the PXIe-1095 synchronize multiple instruments?<\/h4>\n<p>Yes. It distributes 10 MHz and 100 MHz reference clocks and provides PXI trigger, PXI star and PXI Express differential star connections.<\/p>\n<h4>Can the chassis be synchronized with external equipment?<\/h4>\n<p>Yes, when using the Timing and Synchronization configuration. That version provides rear-panel reference clock and trigger connections.<\/p>\n<h4>Can the PXIe-1095 be controlled by an external computer?<\/h4>\n<p>Yes. A compatible PXI Express remote-control interface can be installed in the system controller slot and connected to an appropriate host-side interface.<\/p>\n<h4>Can the chassis operate from 400 Hz aircraft power?<\/h4>\n<p>Yes. The specified input-frequency range extends to 440 Hz, with 400 Hz operation supported from 100 VAC to 120 VAC. Protective-earth and power-circuit requirements must be followed.<\/p>\n<h4>What clearance is required around the chassis?<\/h4>\n<p>Provide at least 101.6 mm behind the chassis and 44.45 mm above and on each side to maintain the required cooling airflow.<\/p>\n<h4>Is the PXIe-1095 suitable for rack installation?<\/h4>\n<p>Yes. Its 18-slot form factor is designed for integration into compatible 19-inch equipment racks using the correct mounting hardware.<\/p>\n<h4>Which software configures the chassis?<\/h4>\n<p>The PXIe-1095 can be identified and configured through NI Measurement &amp; Automation Explorer and the services included with NI PXI Platform Services.<\/p>\n<h3>Recommended Related Products<\/h3>\n<ul>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxie-1092\/\">PXIe-1092 10-Slot PXI Express Chassis<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxie-1090\/\">PXIe-1090 PXI Express Chassis<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxie-1085\/\">PXIe-1085 18-Slot PXI Express Chassis<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxie-1086\/\">PXIe-1086 PXI Express Chassis<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxie-1086dc\/\">PXIe-1086DC DC-Powered PXI Express Chassis<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxie-8842\/\">PXIe-8842 Embedded Controller<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxie-8862\/\">PXIe-8862 Embedded Controller<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxie-8881\/\">PXIe-8881 High-Performance Embedded Controller<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxie-6674t\/\">PXIe-6674T Timing and Synchronization Module<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product-category\/%d0%bd%d0%b8\/pxi-%d1%81%d0%b8%d1%81%d1%82%d0%b5%d0%bc%d1%81\/pxi-chassis\/\">View More NI PXI and PXI Express Chassis<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product-category\/%d0%bd%d0%b8\/pxi-%d1%81%d0%b8%d1%81%d1%82%d0%b5%d0%bc%d1%81\/%d0%bc%d0%be%d0%b4%d1%83%d0%bb%d0%b8-pxi\/\">View More NI PXI and PXI Express Modules<\/a><\/li>\n<\/ul>\n<h3>Request a Quote for the PXIe-1095<\/h3>\n<p>Contact us for current availability, lead time and project pricing for the <strong>NI PXIe-1095 18-Slot PXI Express Chassis<\/strong>. We can supply the standard chassis or the Timing and Synchronization configuration and help identify compatible controllers, power supplies, rack-mount hardware and trigger cables.<\/p>\n<p>When requesting a quote, provide the required part number, power-cord region, controller model and a list of the PXI or PXI Express instruments that will be installed. This allows the slot compatibility, backplane bandwidth, power budget and cooling profile to be reviewed before ordering.<\/p>","protected":false},"excerpt":{"rendered":"<p>\u0422\u0438\u043f \u0448\u0430\u0441\u0441\u0438 PXI: PXI Express<br \/>\n\u0422\u0438\u043f \u0431\u043b\u043e\u043a\u0430 \u043f\u0438\u0442\u0430\u043d\u0438\u044f \u0448\u0430\u0441\u0441\u0438: \u043f\u0435\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0439 \u0442\u043e\u043a<br \/>\n\u041a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u0433\u0438\u0431\u0440\u0438\u0434\u043d\u044b\u0445 \u0441\u043b\u043e\u0442\u043e\u0432: 5<br \/>\n\u041a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u0441\u043b\u043e\u0442\u043e\u0432 PXI Express: 11<br \/>\n\u0418\u0437\u0431\u044b\u0442\u043e\u0447\u043d\u0430\u044f \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u0430\u044f \u043e\u043f\u0446\u0438\u044f: \u0414\u0430<br \/>\n\u041c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u0430\u044f \u043f\u0440\u043e\u043f\u0443\u0441\u043a\u043d\u0430\u044f \u0441\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u044c \u0441\u0438\u0441\u0442\u0435\u043c\u044b: 24 \u0413\u0411\/\u0441<br \/>\n\u041a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u0441\u043b\u043e\u0442\u043e\u0432: 18<br \/>\n\u041a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u0441\u043b\u043e\u0442\u043e\u0432 PXI: 0<br \/>\n\u0421\u0438\u0441\u0442\u0435\u043c\u0430: \u0412\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0439 \u0441\u043b\u043e\u0442: \u0414\u0430<br \/>\n\u041c\u043e\u0449\u043d\u043e\u0441\u0442\u044c \u043e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u044f \u0441\u043b\u043e\u0442\u0430: 82 \u0412\u0442<\/p>","protected":false},"featured_media":31675,"template":"","meta":{"_acf_changed":false},"product_brand":[18],"product_cat":[19],"product_tag":[],"class_list":["post-71","product","type-product","status-publish","has-post-thumbnail","product_brand-national-instruments","product_cat-pxi-chassis","first","instock","shipping-taxable","purchasable","product-type-simple"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.0 (Yoast SEO v28.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>NI PXIe-1095 PXI Chassis 783882-01, 785971-01, In Stock | Project Pricing<\/title>\n<meta name=\"description\" content=\"PXIe-1095 PXI Express chassis provides 18-slot high-performance modular instrumentation capability with advanced cooling and high-bandwidth connectivity for test and measurement systems.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/pxisource.com\/ru\/product\/\u043f\u044c\u0435-1095\/\" \/>\n<meta property=\"og:locale\" content=\"ru_RU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"PXIe-1095\" \/>\n<meta property=\"og:description\" content=\"PXIe-1095 PXI Express chassis provides 18-slot high-performance modular instrumentation capability with advanced cooling and high-bandwidth connectivity for test and measurement systems.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/pxisource.com\/ru\/product\/\u043f\u044c\u0435-1095\/\" \/>\n<meta property=\"og:site_name\" content=\"PXI Source\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=61582573040385\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-07T04:06:31+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PXIe-1095.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"800\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u0426\u0435\u043d\u0430\" \/>\n\t<meta name=\"twitter:data1\" content=\"&#036;18,561.00\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c\" \/>\n\t<meta name=\"twitter:data2\" content=\"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-1095\\\/\",\"url\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-1095\\\/\",\"name\":\"NI PXIe-1095 PXI Chassis 783882-01, 785971-01, In Stock | Project Pricing\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-1095\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-1095\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/PXIe-1095.webp\",\"datePublished\":\"2025-08-20T01:42:11+00:00\",\"dateModified\":\"2026-09-07T04:06:31+00:00\",\"description\":\"PXIe-1095 PXI Express chassis provides 18-slot high-performance modular instrumentation capability with advanced cooling and high-bandwidth connectivity for test and measurement systems.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-1095\\\/#breadcrumb\"},\"inLanguage\":\"ru-RU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-1095\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-1095\\\/#primaryimage\",\"url\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/PXIe-1095.webp\",\"contentUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/PXIe-1095.webp\",\"width\":800,\"height\":800,\"caption\":\"PXIe-1095\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-1095\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/pxisource.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\\\/\\\/pxisource.com\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"PXIe-1095\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\",\"url\":\"https:\\\/\\\/pxisource.com\\\/\",\"name\":\"PXI Systems\",\"description\":\"NI PXI, PXIe Modular Test Instrument Supplier\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/pxisource.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ru-RU\"}]}<\/script>\n<meta property=\"product:brand\" content=\"National Instruments\" \/>\n<meta property=\"product:price:amount\" content=\"18561.00\" \/>\n<meta property=\"product:price:currency\" content=\"USD\" \/>\n<meta property=\"og:availability\" content=\"instock\" \/>\n<meta property=\"product:availability\" content=\"instock\" \/>\n<meta property=\"product:condition\" content=\"new\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"NI PXIe-1095 PXI Chassis 783882-01, 785971-01, In Stock | Project Pricing","description":"PXIe-1095 PXI Express chassis provides 18-slot high-performance modular instrumentation capability with advanced cooling and high-bandwidth connectivity for test and measurement systems.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/pxisource.com\/ru\/product\/\u043f\u044c\u0435-1095\/","og_locale":"ru_RU","og_type":"article","og_title":"PXIe-1095","og_description":"PXIe-1095 PXI Express chassis provides 18-slot high-performance modular instrumentation capability with advanced cooling and high-bandwidth connectivity for test and measurement systems.","og_url":"https:\/\/pxisource.com\/ru\/product\/\u043f\u044c\u0435-1095\/","og_site_name":"PXI Source","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=61582573040385","article_modified_time":"2026-09-07T04:06:31+00:00","og_image":[{"width":800,"height":800,"url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PXIe-1095.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"\u0426\u0435\u043d\u0430":"&#36;18,561.00","\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c":"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/pxisource.com\/product\/pxie-1095\/","url":"https:\/\/pxisource.com\/product\/pxie-1095\/","name":"NI PXIe-1095 PXI Chassis 783882-01, 785971-01, In Stock | Project Pricing","isPartOf":{"@id":"https:\/\/pxisource.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/pxisource.com\/product\/pxie-1095\/#primaryimage"},"image":{"@id":"https:\/\/pxisource.com\/product\/pxie-1095\/#primaryimage"},"thumbnailUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PXIe-1095.webp","datePublished":"2025-08-20T01:42:11+00:00","dateModified":"2026-09-07T04:06:31+00:00","description":"PXIe-1095 PXI Express chassis provides 18-slot high-performance modular instrumentation capability with advanced cooling and high-bandwidth connectivity for test and measurement systems.","breadcrumb":{"@id":"https:\/\/pxisource.com\/product\/pxie-1095\/#breadcrumb"},"inLanguage":"ru-RU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/pxisource.com\/product\/pxie-1095\/"]}]},{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/pxisource.com\/product\/pxie-1095\/#primaryimage","url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PXIe-1095.webp","contentUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PXIe-1095.webp","width":800,"height":800,"caption":"PXIe-1095"},{"@type":"BreadcrumbList","@id":"https:\/\/pxisource.com\/product\/pxie-1095\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/pxisource.com\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/pxisource.com\/shop\/"},{"@type":"ListItem","position":3,"name":"PXIe-1095"}]},{"@type":"WebSite","@id":"https:\/\/pxisource.com\/#website","url":"https:\/\/pxisource.com\/","name":"\u0421\u0438\u0441\u0442\u0435\u043c\u044b PXI","description":"NI PXI, PXIe Modular Test Instrument Supplier","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/pxisource.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ru-RU"}]},"product_brand":"National Instruments","product_price_amount":"18561.00","product_price_currency":"USD","og_availability":"instock","product_availability":"instock","product_condition":"new"},"_links":{"self":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/71","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":17,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/71\/revisions"}],"predecessor-version":[{"id":36301,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/71\/revisions\/36301"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media\/31675"}],"wp:attachment":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media?parent=71"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_brand?post=71"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_cat?post=71"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_tag?post=71"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}