{"id":36422,"date":"2026-09-07T22:44:01","date_gmt":"2026-09-07T14:44:01","guid":{"rendered":"https:\/\/pxisource.com\/?post_type=product&#038;p=36422"},"modified":"2026-09-18T15:04:23","modified_gmt":"2026-09-18T07:04:23","slug":"pci-6280","status":"publish","type":"product","link":"https:\/\/pxisource.com\/ru\/product\/pci-6280\/","title":{"rendered":"PCI-6280"},"content":{"rendered":"<h3>PCI-6280 18-Bit Multifunction Data Acquisition Device<\/h3>\n<p>\u0417\u0435\u043c\u043b\u044f <strong>PCI-6280<\/strong> is a high-accuracy M Series multifunction data acquisition device designed for PCI-based automated measurement, laboratory and electronic test systems. It provides 16 single-ended or eight differential analog input channels with 18-bit resolution.<\/p>\n<p>The device supports single-channel sampling rates up to 625 kS\/s and multichannel aggregate rates up to 500 kS\/s. It also includes 24 digital I\/O lines, two 32-bit counters\/timers, digital triggering and RTSI synchronization for coordinating multiple PCI measurement devices.<\/p>\n<h3>Key Features of the PCI-6280<\/h3>\n<ul>\n<li>16 single-ended or eight differential analog inputs<\/li>\n<li>18-bit analog input resolution<\/li>\n<li>625 kS\/s maximum single-channel sampling rate<\/li>\n<li>500 kS\/s maximum multichannel aggregate rate<\/li>\n<li>Seven software-selectable input ranges<\/li>\n<li>\u00b110 V maximum nominal input range<\/li>\n<li>Selectable 40 kHz low-pass input filter<\/li>\n<li>24 programmable digital I\/O lines<\/li>\n<li>Two 32-bit general-purpose counters\/timers<\/li>\n<li>80 MHz counter timebase<\/li>\n<li>Digital waveform acquisition and generation<\/li>\n<li>RTSI synchronization support<\/li>\n<li>68-pin VHDCI front-panel connector<\/li>\n<li>NI-DAQmx software support<\/li>\n<\/ul>\n<h2>PCI-6280 Technical Specifications<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Product Model<\/th>\n<td>PCI-6280<\/td>\n<\/tr>\n<tr>\n<th>Product Series<\/th>\n<td>High-Accuracy M Series DAQ<\/td>\n<\/tr>\n<tr>\n<th>\u0428\u0438\u043d\u043d\u044b\u0439 \u0438\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441<\/th>\n<td>32-bit PCI, 3.3 V or 5 V signaling environment<\/td>\n<\/tr>\n<tr>\n<th>Analog Input Channels<\/th>\n<td>16 single-ended or 8 differential<\/td>\n<\/tr>\n<tr>\n<th>ADC Resolution<\/th>\n<td>18 bits<\/td>\n<\/tr>\n<tr>\n<th>Single-Channel Sample Rate<\/th>\n<td>625 kS\/s maximum<\/td>\n<\/tr>\n<tr>\n<th>Multichannel Sample Rate<\/th>\n<td>500 kS\/s maximum aggregate<\/td>\n<\/tr>\n<tr>\n<th>Input Ranges<\/th>\n<td>\u00b10.1 V, \u00b10.2 V, \u00b10.5 V, \u00b11 V, \u00b12 V, \u00b15 V and \u00b110 V<\/td>\n<\/tr>\n<tr>\n<th>Input Coupling<\/th>\n<td>DC<\/td>\n<\/tr>\n<tr>\n<th>Input Bandwidth<\/th>\n<td>750 kHz with filter off; 40 kHz with filter on<\/td>\n<\/tr>\n<tr>\n<th>CMRR<\/th>\n<td>110 dB, DC to 60 Hz<\/td>\n<\/tr>\n<tr>\n<th>\u0426\u0438\u0444\u0440\u043e\u0432\u043e\u0439 \u0432\u0432\u043e\u0434-\u0432\u044b\u0432\u043e\u0434<\/th>\n<td>24 programmable lines<\/td>\n<\/tr>\n<tr>\n<th>Counters\/Timers<\/th>\n<td>2 \u00d7 32-bit<\/td>\n<\/tr>\n<tr>\n<th>Counter Timebases<\/th>\n<td>80 MHz, 20 MHz and 100 kHz<\/td>\n<\/tr>\n<tr>\n<th>Synchronization Bus<\/th>\n<td>RTSI<\/td>\n<\/tr>\n<tr>\n<th>DMA Channels<\/th>\n<td>6<\/td>\n<\/tr>\n<tr>\n<th>I\/O Connector<\/th>\n<td>68-pin VHDCI<\/td>\n<\/tr>\n<tr>\n<th>Calibration Interval<\/th>\n<td>2 years<\/td>\n<\/tr>\n<tr>\n<th>Operating Temperature<\/th>\n<td>0\u00b0C to 55\u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Weight<\/th>\n<td>Approximately 151 g<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>PCI-6280 Part Number and Accessories<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Item<\/th>\n<th>Part Number<\/th>\n<th>\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435<\/th>\n<\/tr>\n<tr>\n<td>PCI-6280<\/td>\n<td>779108-01<\/td>\n<td>18-bit, 16-channel high-accuracy PCI multifunction DAQ device<\/td>\n<\/tr>\n<tr>\n<td>SHC68-68-EPM Cable<\/td>\n<td>Length dependent<\/td>\n<td>Shielded 68-pin cable for M Series DAQ connections<\/td>\n<\/tr>\n<tr>\n<td>SCB-68A<\/td>\n<td>Configuration dependent<\/td>\n<td>Shielded screw-terminal connector block<\/td>\n<\/tr>\n<tr>\n<td>BNC-2120<\/td>\n<td>Configuration dependent<\/td>\n<td>BNC connectivity accessory for laboratory signal access<\/td>\n<\/tr>\n<tr>\n<td>RTSI Cable<\/td>\n<td>Configuration dependent<\/td>\n<td>Routes timing and triggering between compatible PCI devices<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The PCI-6280 uses one 68-pin VHDCI connector. Confirm cable compatibility because similarly sized 68-pin cables may have different shielding, connector orientation or supported signal assignments.<\/p>\n<h3>18-Bit High-Accuracy Analog Input<\/h3>\n<p>The 18-bit ADC provides greater measurement resolution than standard 16-bit M Series devices. This is useful when small signal changes must be detected across a relatively wide input range.<\/p>\n<p>The card offers ranges down to \u00b10.1 V, allowing the programmable gain stage to use more of the ADC range for low-level voltage measurements. Source impedance, noise, grounding and settling time must still be considered when scanning several channels.<\/p>\n<h3>Selectable 40 kHz Input Filter<\/h3>\n<p>A selectable analog input filter reduces the signal bandwidth from approximately 750 kHz to 40 kHz. It can help reduce high-frequency noise when measuring slowly changing sensor and control signals.<\/p>\n<p>Enabling the filter increases settling requirements during multichannel scanning. The application should allow sufficient convert time after changing channels or input ranges.<\/p>\n<h3>Digital I\/O and Counters<\/h3>\n<p>The 24 digital lines support static control and correlated digital waveform operations. Two 32-bit counters can perform edge counting, pulse measurement, frequency measurement, encoder input and pulse-train generation.<\/p>\n<h3>RTSI Multi-Device Synchronization<\/h3>\n<p>The RTSI bus can route clocks and triggers between compatible PCI devices inside the same computer. This allows analog acquisition, digital I\/O and counter tasks on several cards to start from a common hardware event.<\/p>\n<h2>PCI-6280 Applications<\/h2>\n<ul>\n<li>Precision voltage acquisition<\/li>\n<li>Automated electronic testing<\/li>\n<li>Scientific laboratory measurements<\/li>\n<li>Sensor and transducer monitoring<\/li>\n<li>Production functional testing<\/li>\n<li>\u0420\u0435\u0433\u0438\u0441\u0442\u0440\u0430\u0446\u0438\u044f \u0434\u0430\u043d\u043d\u044b\u0445<\/li>\n<li>Low-level signal measurements<\/li>\n<li>Digital control and monitoring<\/li>\n<li>Encoder and frequency measurements<\/li>\n<li>Multi-device synchronized acquisition<\/li>\n<li>Research and development<\/li>\n<li>Legacy PCI test-system maintenance<\/li>\n<\/ul>\n<h3>Precision Sensor Acquisition<\/h3>\n<p>The selectable input ranges and 18-bit ADC make the PCI-6280 suitable for conditioned sensor signals. External signal conditioning is still required for thermocouples, strain gauges, IEPE sensors and other sensors that do not directly provide a compatible voltage.<\/p>\n<h3>Automated Test Equipment<\/h3>\n<p>Analog inputs can measure DUT voltages while digital lines and counters control fixtures, monitor status signals and generate timing events. NI-DAQmx coordinates these functions within one automated test application.<\/p>\n<h2>PCI-6280 Installation Workflow<\/h2>\n<h4>Step 1: Confirm the Computer Interface<\/h4>\n<p>Verify that the computer provides a compatible conventional PCI slot. PCI Express-only systems require a different DAQ model or an appropriate external chassis solution.<\/p>\n<h4>Step 2: Install NI-DAQmx<\/h4>\n<p>Install a driver version compatible with the operating system and PCI-6280 before developing the measurement application.<\/p>\n<h4>Step 3: Install the PCI Card<\/h4>\n<p>Shut down and disconnect the computer, insert the PCI-6280 into the slot and secure its mounting bracket.<\/p>\n<h4>Step 4: Connect the Cable and Terminal Block<\/h4>\n<p>Attach the supported shielded cable and terminal accessory. Verify the PCI-6280 pinout before applying any signals.<\/p>\n<h4>Step 5: Configure the Device in NI MAX<\/h4>\n<p>Confirm that the board is detected, create channel configurations and run a self-test.<\/p>\n<h4>Step 6: Validate the Analog Inputs<\/h4>\n<p>Apply a known voltage within the selected range and compare the acquired result with a calibrated reference instrument.<\/p>\n<h4>Step 7: Configure Timing and Triggering<\/h4>\n<p>Set the sample rate, channel list, terminal configuration, filter state and hardware trigger required by the test.<\/p>\n<h2>PCI-6280 Troubleshooting<\/h2>\n<h4>The computer does not detect the PCI-6280<\/h4>\n<p>Reseat the board, try another compatible PCI slot and confirm that the installed NI-DAQmx version supports both the device and operating system.<\/p>\n<h4>The acquired voltage is inaccurate<\/h4>\n<p>Check differential or single-ended terminal configuration, signal grounding, source impedance and input range. Allow at least the recommended 15-minute warm-up period.<\/p>\n<h4>Adjacent channels affect one another<\/h4>\n<p>Reduce source impedance, slow the convert clock or insert additional settling time between channels. Ghosting is more likely when scanning high-impedance sources.<\/p>\n<h4>The measurement contains excessive noise<\/h4>\n<p>Use differential connections and shielded cable, improve grounding and enable the 40 kHz filter when the required signal bandwidth permits it.<\/p>\n<h4>Digital waveform tasks do not start<\/h4>\n<p>The digital subsystem requires a sample clock from another onboard subsystem or an external source. Verify the clock route and trigger configuration.<\/p>\n<h2>PCI-6280 Comparison<\/h2>\n<table>\n<tbody>\n<tr>\n<th>\u041c\u043e\u0434\u0435\u043b\u044c<\/th>\n<th>Primary Configuration<\/th>\n<th>Best Suited For<\/th>\n<\/tr>\n<tr>\n<td>PCI-6280<\/td>\n<td>16 AI, 18 bit, 625 kS\/s, 24 DIO, no AO<\/td>\n<td>High-resolution analog acquisition<\/td>\n<\/tr>\n<tr>\n<td>PCI-6281<\/td>\n<td>16 AI, 18 bit, analog output and digital I\/O<\/td>\n<td>High-accuracy multifunction input and output<\/td>\n<\/tr>\n<tr>\n<td>PCI-6284<\/td>\n<td>32 AI, 18 bit, 48 DIO<\/td>\n<td>Higher analog and digital channel density<\/td>\n<\/tr>\n<tr>\n<td>PCI-6224<\/td>\n<td>32 AI, 16 bit, 250 kS\/s, 48 DIO<\/td>\n<td>Cost-effective high-channel-count acquisition<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Recommended Related Products<\/h3>\n<ul>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pci-6281\/\">PCI-6281 High-Accuracy Multifunction DAQ<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pci-6224\/\">PCI-6224 Multifunction DAQ Device<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pci-6233\/\">PCI-6233 Isolated Multifunction DAQ<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product-category\/%d0%bd%d0%b8\/pci-usb-data-acquisition\/\">View More NI PCI and USB DAQ Products<\/a><\/li>\n<\/ul>\n<h2>Frequently Asked Questions<\/h2>\n<h4>What is the PCI-6280?<\/h4>\n<p>The PCI-6280 is an 18-bit PCI multifunction data acquisition board with analog inputs, digital I\/O and counter\/timer functions.<\/p>\n<h4>What is its maximum sample rate?<\/h4>\n<p>It supports up to 625 kS\/s on one channel or 500 kS\/s aggregate when scanning multiple channels.<\/p>\n<h4>Does the PCI-6280 provide analog outputs?<\/h4>\n<p>No. Select the PCI-6281 or another multifunction model when analog output channels are required.<\/p>\n<h4>How many digital I\/O lines are available?<\/h4>\n<p>The device provides 24 programmable digital I\/O lines.<\/p>\n<h4>What is the PCI-6280 part number?<\/h4>\n<p>The standard ordering part number is <strong>779108-01<\/strong>.<\/p>\n<h3>Request a Quote for the PCI-6280<\/h3>\n<p>Contact us for availability, lead time and pricing for the <strong>PCI-6280 18-Bit Multifunction DAQ Device<\/strong>. We can also help identify compatible cables, terminal blocks and replacement PCI or PCI Express DAQ models.<\/p>","protected":false},"excerpt":{"rendered":"<p>PCI-6280 18-Bit Multifunction Data Acquisition Device The PCI-6280 is a high-accuracy M Series multifunction data acquisition device designed for PCI-based<\/p>","protected":false},"featured_media":36423,"template":"","meta":{"_acf_changed":false},"product_brand":[18],"product_cat":[674],"product_tag":[],"class_list":["post-36422","product","type-product","status-publish","has-post-thumbnail","product_brand-national-instruments","product_cat-pci-modules","first","instock","shipping-taxable","product-type-simple"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.0 (Yoast SEO v28.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>NI PCI-6280 PCI Multifunction I\/O Device 779108-01, In Stock | Project Pricing<\/title>\n<meta name=\"description\" content=\"The PCI-6280 provides 18-bit analog acquisition, up to 625 kS\/s single-channel sampling, 24 digital I\/O and programmable timing.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/pxisource.com\/ru\/product\/pci-6280\/\" \/>\n<meta property=\"og:locale\" content=\"ru_RU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"PCI-6280\" \/>\n<meta property=\"og:description\" content=\"The PCI-6280 provides 18-bit analog acquisition, up to 625 kS\/s single-channel sampling, 24 digital I\/O and programmable timing.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/pxisource.com\/ru\/product\/pci-6280\/\" \/>\n<meta property=\"og:site_name\" content=\"PXI Source\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=61582573040385\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-18T07:04:23+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/09\/PCI-6280.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"800\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u0426\u0435\u043d\u0430\" \/>\n\t<meta name=\"twitter:data1\" content=\"\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c\" \/>\n\t<meta name=\"twitter:data2\" content=\"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pci-6280\\\/\",\"url\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pci-6280\\\/\",\"name\":\"NI PCI-6280 PCI Multifunction I\\\/O Device 779108-01, In Stock | Project Pricing\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pci-6280\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pci-6280\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/PCI-6280.jpg\",\"datePublished\":\"2026-09-07T14:44:01+00:00\",\"dateModified\":\"2026-09-18T07:04:23+00:00\",\"description\":\"The PCI-6280 provides 18-bit analog acquisition, up to 625 kS\\\/s single-channel sampling, 24 digital I\\\/O and programmable timing.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pci-6280\\\/#breadcrumb\"},\"inLanguage\":\"ru-RU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/pxisource.com\\\/product\\\/pci-6280\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pci-6280\\\/#primaryimage\",\"url\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/PCI-6280.jpg\",\"contentUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/PCI-6280.jpg\",\"width\":800,\"height\":800,\"caption\":\"PCI-6280\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pci-6280\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/pxisource.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\\\/\\\/pxisource.com\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"PCI-6280\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\",\"url\":\"https:\\\/\\\/pxisource.com\\\/\",\"name\":\"PXI Systems\",\"description\":\"NI PXI, PXIe Modular Test Instrument Supplier\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/pxisource.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ru-RU\"}]}<\/script>\n<meta property=\"product:brand\" content=\"National Instruments\" \/>\n<meta property=\"product:price:currency\" content=\"USD\" \/>\n<meta property=\"og:availability\" content=\"instock\" \/>\n<meta property=\"product:availability\" content=\"instock\" \/>\n<meta property=\"product:condition\" content=\"new\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"NI PCI-6280 PCI Multifunction I\/O Device 779108-01, In Stock | Project Pricing","description":"The PCI-6280 provides 18-bit analog acquisition, up to 625 kS\/s single-channel sampling, 24 digital I\/O and programmable timing.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/pxisource.com\/ru\/product\/pci-6280\/","og_locale":"ru_RU","og_type":"article","og_title":"PCI-6280","og_description":"The PCI-6280 provides 18-bit analog acquisition, up to 625 kS\/s single-channel sampling, 24 digital I\/O and programmable timing.","og_url":"https:\/\/pxisource.com\/ru\/product\/pci-6280\/","og_site_name":"PXI Source","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=61582573040385","article_modified_time":"2026-09-18T07:04:23+00:00","og_image":[{"width":800,"height":800,"url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/09\/PCI-6280.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"\u0426\u0435\u043d\u0430":"","\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c":"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/pxisource.com\/product\/pci-6280\/","url":"https:\/\/pxisource.com\/product\/pci-6280\/","name":"NI PCI-6280 PCI Multifunction I\/O Device 779108-01, In Stock | Project Pricing","isPartOf":{"@id":"https:\/\/pxisource.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/pxisource.com\/product\/pci-6280\/#primaryimage"},"image":{"@id":"https:\/\/pxisource.com\/product\/pci-6280\/#primaryimage"},"thumbnailUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/09\/PCI-6280.jpg","datePublished":"2026-09-07T14:44:01+00:00","dateModified":"2026-09-18T07:04:23+00:00","description":"The PCI-6280 provides 18-bit analog acquisition, up to 625 kS\/s single-channel sampling, 24 digital I\/O and programmable timing.","breadcrumb":{"@id":"https:\/\/pxisource.com\/product\/pci-6280\/#breadcrumb"},"inLanguage":"ru-RU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/pxisource.com\/product\/pci-6280\/"]}]},{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/pxisource.com\/product\/pci-6280\/#primaryimage","url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/09\/PCI-6280.jpg","contentUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/09\/PCI-6280.jpg","width":800,"height":800,"caption":"PCI-6280"},{"@type":"BreadcrumbList","@id":"https:\/\/pxisource.com\/product\/pci-6280\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/pxisource.com\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/pxisource.com\/shop\/"},{"@type":"ListItem","position":3,"name":"PCI-6280"}]},{"@type":"WebSite","@id":"https:\/\/pxisource.com\/#website","url":"https:\/\/pxisource.com\/","name":"\u0421\u0438\u0441\u0442\u0435\u043c\u044b PXI","description":"NI PXI, PXIe Modular Test Instrument Supplier","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/pxisource.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ru-RU"}]},"product_brand":"National Instruments","product_price_currency":"USD","og_availability":"instock","product_availability":"instock","product_condition":"new"},"_links":{"self":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/36422","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":4,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/36422\/revisions"}],"predecessor-version":[{"id":36426,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/36422\/revisions\/36426"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media\/36423"}],"wp:attachment":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media?parent=36422"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_brand?post=36422"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_cat?post=36422"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_tag?post=36422"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}