{"id":35359,"date":"2026-08-25T14:31:54","date_gmt":"2026-08-25T06:31:54","guid":{"rendered":"https:\/\/pxisource.com\/?post_type=product&#038;p=35359"},"modified":"2026-09-10T16:06:44","modified_gmt":"2026-09-10T08:06:44","slug":"pci-6013","status":"publish","type":"product","link":"https:\/\/pxisource.com\/ru\/product\/pci-6013\/","title":{"rendered":"PCI-6013"},"content":{"rendered":"<h3>PCI-6013 16-Channel 16-Bit Multifunction DAQ Device<\/h3>\n<p>\u0417\u0435\u043c\u043b\u044f <strong>NI PCI-6013<\/strong> is a B Series multifunction data acquisition board designed for OEM equipment, laboratory automation, research, design verification and manufacturing test.<\/p>\n<p>It provides 16 single-ended analog inputs with 16-bit resolution and a maximum aggregate sampling rate of 200 kS\/s. The analog subsystem is designed for general-purpose voltage measurement and conditioned sensor acquisition.<\/p>\n<p>Eight digital I\/O lines and two 24-bit counter\/timers provide additional monitoring, control and timing capabilities. The PCI-6013 does not include analog output channels.<\/p>\n<h3>Key Features of the PCI-6013<\/h3>\n<ul>\n<li>16 analog input channels<\/li>\n<li>16-bit analog input resolution<\/li>\n<li>200 kS\/s maximum aggregate sampling<\/li>\n<li>Multiplexed analog input architecture<\/li>\n<li>Eight digital I\/O lines<\/li>\n<li>Two 24-bit counter\/timers<\/li>\n<li>Digital triggering support<\/li>\n<li>Concurrent analog, digital and counter operations<\/li>\n<li>68-pin front-panel connector<\/li>\n<li>Conventional PCI interface<\/li>\n<li>NI-DAQmx support<\/li>\n<li>Designed for OEM and automated test systems<\/li>\n<\/ul>\n<h2>PCI-6013 Technical Specifications<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Product Model<\/th>\n<td>PCI-6013<\/td>\n<\/tr>\n<tr>\n<th>Orderable Part Number<\/th>\n<td>778629-01<\/td>\n<\/tr>\n<tr>\n<th>Additional Hardware Number<\/th>\n<td>188626-02<\/td>\n<\/tr>\n<tr>\n<th>Product Family<\/th>\n<td>NI B Series Multifunction DAQ<\/td>\n<\/tr>\n<tr>\n<th>\u0428\u0438\u043d\u043d\u044b\u0439 \u0438\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441<\/th>\n<td>Conventional PCI<\/td>\n<\/tr>\n<tr>\n<th>Analog Inputs<\/th>\n<td>16 single-ended channels<\/td>\n<\/tr>\n<tr>\n<th>Analog Input Resolution<\/th>\n<td>16 bits<\/td>\n<\/tr>\n<tr>\n<th>Maximum Sample Rate<\/th>\n<td>200 kS\/s aggregate<\/td>\n<\/tr>\n<tr>\n<th>Sampling Architecture<\/th>\n<td>Multiplexed<\/td>\n<\/tr>\n<tr>\n<th>Analog Outputs<\/th>\n<td>\u041d\u0438\u0447\u0435\u0433\u043e<\/td>\n<\/tr>\n<tr>\n<th>\u0426\u0438\u0444\u0440\u043e\u0432\u043e\u0439 \u0432\u0432\u043e\u0434-\u0432\u044b\u0432\u043e\u0434<\/th>\n<td>8 bidirectional lines<\/td>\n<\/tr>\n<tr>\n<th>Counter\/Timers<\/th>\n<td>2 \u00d7 24-bit<\/td>\n<\/tr>\n<tr>\n<th>\u0417\u0430\u043f\u0443\u0441\u043a<\/th>\n<td>Digital triggering<\/td>\n<\/tr>\n<tr>\n<th>Front Connector<\/th>\n<td>68-pin connector<\/td>\n<\/tr>\n<tr>\n<th>Driver Software<\/th>\n<td>\u041d\u0418-DAQmx<\/td>\n<\/tr>\n<tr>\n<th>Lifecycle Status<\/th>\n<td>Discontinued and no longer supported by NI<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The PCI-6013 can sustain digital and counter\/timer operations while performing analog acquisition. Available PCI bus and driver resources should still be considered when several tasks run concurrently.<\/p>\n<h2>PCI-6013 Part Number and Accessories<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Item<\/th>\n<th>Part Number<\/th>\n<th>\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435<\/th>\n<\/tr>\n<tr>\n<td>PCI-6013<\/td>\n<td>778629-01<\/td>\n<td>16-bit, 200 kS\/s PCI multifunction DAQ device<\/td>\n<\/tr>\n<tr>\n<td>PCI-6013 Hardware<\/td>\n<td>188626-02<\/td>\n<td>Hardware or assembly identifier associated with some units<\/td>\n<\/tr>\n<tr>\n<td>Shielded 68-Pin Cable<\/td>\n<td>Length dependent<\/td>\n<td>Connects the PCI-6013 to a terminal accessory<\/td>\n<\/tr>\n<tr>\n<td>SCB-68A<\/td>\n<td>782536-01<\/td>\n<td>Shielded screw-terminal connector block<\/td>\n<\/tr>\n<tr>\n<td>BNC-2110<\/td>\n<td>777643-01<\/td>\n<td>BNC accessory for analog and digital signal access<\/td>\n<\/tr>\n<tr>\n<td>CB-68LP<\/td>\n<td>777145-01<\/td>\n<td>General-purpose screw-terminal connector block<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Confirm whether the buyer requires commercial part number 778629-01 or a specific hardware assembly number. Different board revisions may be important when replacing a device in a validated test system.<\/p>\n<h3>16-Bit Analog Measurement<\/h3>\n<p>The 16-bit converter provides 65,536 possible digital codes across the selected input range. This offers finer voltage resolution than older 12-bit multifunction DAQ boards.<\/p>\n<p>Measurement accuracy also depends on calibration, signal range, source impedance, grounding, noise and the external signal path.<\/p>\n<h3>200 kS\/s Aggregate Sampling<\/h3>\n<p>The maximum 200 kS\/s rate is shared by the analog input channels included in the acquisition task. The required per-channel rate should be calculated according to the number of active channels.<\/p>\n<p>Because the channels are multiplexed, they are sampled sequentially rather than simultaneously. Phase-sensitive measurements may require a simultaneous-sampling device.<\/p>\n<h3>Eight Digital I\/O Lines<\/h3>\n<p>Eight digital lines can monitor logic conditions or control compatible external devices. External drivers are required for relays, solenoids and higher-current loads.<\/p>\n<h3>Two 24-Bit Counter\/Timers<\/h3>\n<p>The counter\/timers support event counting, frequency measurement, pulse-width measurement and pulse generation. Input signals must have clean transitions and compatible logic levels.<\/p>\n<h3>NI-DAQmx Software<\/h3>\n<p>NI-DAQmx provides hardware configuration and measurement APIs. However, the PCI-6013 is discontinued, so operating-system and driver compatibility must be verified before changing the host computer.<\/p>\n<h2>PCI-6013 Applications<\/h2>\n<ul>\n<li>OEM measurement equipment<\/li>\n<li>Laboratory data acquisition<\/li>\n<li>Manufacturing test<\/li>\n<li>Design verification<\/li>\n<li>General-purpose voltage monitoring<\/li>\n<li>Conditioned sensor acquisition<\/li>\n<li>Digital status monitoring<\/li>\n<li>Fixture control<\/li>\n<li>Frequency and event measurement<\/li>\n<\/ul>\n<h3>OEM Measurement Systems<\/h3>\n<p>The PCI-6013 provides analog, digital and counter resources for dedicated measurement equipment built around a desktop or industrial computer.<\/p>\n<h3>Manufacturing Test<\/h3>\n<p>The analog inputs can verify DUT voltage levels while digital lines and counters monitor production fixture and timing signals.<\/p>\n<h3>Long-Term Data Logging<\/h3>\n<p>The device can record moderate-bandwidth voltage and conditioned sensor signals. Application software should monitor disk space, buffer status and acquisition errors.<\/p>\n<h2>PCI-6013 Installation Workflow<\/h2>\n<h4>Step 1: Verify the Host Computer<\/h4>\n<p>Confirm that the computer provides an available conventional PCI slot.<\/p>\n<h4>Step 2: Check Driver Compatibility<\/h4>\n<p>Verify that the planned operating system and NI-DAQmx version support the discontinued PCI-6013.<\/p>\n<h4>Step 3: Install the Board<\/h4>\n<p>Power down the computer, observe ESD precautions and install the card securely.<\/p>\n<h4>Step 4: Connect the Terminal Accessory<\/h4>\n<p>Install a compatible shielded 68-pin cable and verify the PCI-6013 pinout.<\/p>\n<h4>Step 5: Run NI MAX Diagnostics<\/h4>\n<p>Perform a device self-test and acquire a known voltage using a test panel.<\/p>\n<h4>Step 6: Validate the DAQ Task<\/h4>\n<p>Confirm channel ranges, sampling rate, grounding, digital directions and counter terminals.<\/p>\n<h2>PCI-6013 Troubleshooting<\/h2>\n<h4>The device does not appear in NI MAX<\/h4>\n<p>Check PCI slot compatibility, board seating and whether the NI-DAQmx version supports the PCI-6013.<\/p>\n<h4>The input readings are unstable<\/h4>\n<p>Review grounding, shielding, signal-source impedance and nearby interference sources.<\/p>\n<h4>The acquisition is slower than expected<\/h4>\n<p>The 200 kS\/s rate is an aggregate value shared by all active channels.<\/p>\n<h4>A digital output cannot drive a relay<\/h4>\n<p>Install an external transistor, relay driver or isolated digital interface.<\/p>\n<h4>The replacement board behaves differently<\/h4>\n<p>Compare the orderable part number, assembly number, revision, calibration status and software configuration.<\/p>\n<h2>PCI-6013 Comparison<\/h2>\n<table>\n<tbody>\n<tr>\n<th>\u041c\u043e\u0434\u0435\u043b\u044c<\/th>\n<th>AI<\/th>\n<th>\u0420\u0430\u0437\u0440\u0435\u0448\u0435\u043d\u0438\u0435<\/th>\n<th>AO<\/th>\n<th>Primary Difference<\/th>\n<\/tr>\n<tr>\n<td>PCI-6013<\/td>\n<td>16<\/td>\n<td>16-\u0431\u0438\u0442\u043d\u044b\u0439<\/td>\n<td>0<\/td>\n<td>Input-focused B Series DAQ<\/td>\n<\/tr>\n<tr>\n<td><a href=\"https:\/\/pxisource.com\/ru\/product\/pci-6014\/\">PCI-6014<\/a><\/td>\n<td>16<\/td>\n<td>16-\u0431\u0438\u0442\u043d\u044b\u0439<\/td>\n<td>2<\/td>\n<td>Adds analog outputs<\/td>\n<\/tr>\n<tr>\n<td><a href=\"https:\/\/pxisource.com\/ru\/product\/pci-6024e\/\">PCI-6024E<\/a><\/td>\n<td>16<\/td>\n<td>12-bit<\/td>\n<td>2<\/td>\n<td>Lower input resolution<\/td>\n<\/tr>\n<tr>\n<td><a href=\"https:\/\/pxisource.com\/ru\/product\/pci-6220\/\">PCI-6220<\/a><\/td>\n<td>16<\/td>\n<td>16-\u0431\u0438\u0442\u043d\u044b\u0439<\/td>\n<td>0<\/td>\n<td>M Series with additional digital resources<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>PCI-6013 vs PCI-6014<\/h3>\n<p>The two boards provide similar 16-bit, 200 kS\/s analog input functionality. The PCI-6014 adds two analog output channels, while the PCI-6013 is focused on acquisition.<\/p>\n<h3>PCI-6013 vs PCI-6220<\/h3>\n<p>The PCI-6220 provides a newer M Series architecture, a 250 kS\/s sample rate, 24 digital I\/O lines and 32-bit counters. Migration requires connector, software and timing verification.<\/p>\n<h3>Why Choose the PCI-6013?<\/h3>\n<p>Choose the PCI-6013 when maintaining a validated legacy system that requires the same B Series architecture, PCI interface and existing fixture wiring.<\/p>\n<h2>PCI-6013 Frequently Asked Questions<\/h2>\n<h4>What is the PCI-6013 part number?<\/h4>\n<p>The commercial orderable part number is <strong>778629-01<\/strong>. Some units may also reference hardware number 188626-02.<\/p>\n<h4>How many analog inputs are provided?<\/h4>\n<p>The PCI-6013 provides 16 analog input channels.<\/p>\n<h4>Does it include analog outputs?<\/h4>\n<p>No. The PCI-6014 is a related model with two analog outputs.<\/p>\n<h4>What is the maximum sample rate?<\/h4>\n<p>The maximum aggregate analog input rate is 200 kS\/s.<\/p>\n<h4>Is the PCI-6013 discontinued?<\/h4>\n<p>Yes. NI lists the product as discontinued and no longer supported.<\/p>\n<h4>What should be checked when buying a replacement?<\/h4>\n<p>Verify the part number, assembly revision, connector, calibration condition and driver compatibility.<\/p>\n<h3>Recommended Related Products<\/h3>\n<ul>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pci-6014\/\">PCI-6014 Multifunction DAQ Device<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pci-6024e\/\">PCI-6024E Multifunction DAQ Device<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pci-6220\/\">PCI-6220 Multifunction DAQ Device<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pcie-6320\/\">PCIe-6320 Multifunction DAQ Device<\/a><\/li>\n<\/ul>\n<h3>Request a Quote for the PCI-6013<\/h3>\n<p>Contact us for availability and pricing for the <strong>NI PCI-6013 Multifunction DAQ Device<\/strong>. Please provide the complete part number and board revision so that we can verify compatibility.<\/p>","protected":false},"excerpt":{"rendered":"<p>PCI-6013 16-Channel 16-Bit Multifunction DAQ Device The NI PCI-6013 is a B Series multifunction data acquisition board designed for OEM<\/p>","protected":false},"featured_media":35234,"template":"","meta":{"_acf_changed":false},"product_brand":[18],"product_cat":[674],"product_tag":[],"class_list":["post-35359","product","type-product","status-publish","has-post-thumbnail","product_brand-national-instruments","product_cat-pci-modules","first","instock","shipping-taxable","product-type-simple"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.0 (Yoast SEO v28.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>NI PCI-6013 PCI Multifunction I\/O Device 188626-02, In Stock | Project Pricing<\/title>\n<meta name=\"description\" content=\"The PCI-6013 is a 16-bit PCI multifunction DAQ device with 16 analog inputs, 200 kS\/s sampling, eight DIO lines and two counters.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/pxisource.com\/ru\/product\/pci-6013\/\" \/>\n<meta property=\"og:locale\" content=\"ru_RU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"PCI-6013\" \/>\n<meta property=\"og:description\" content=\"The PCI-6013 is a 16-bit PCI multifunction DAQ device with 16 analog inputs, 200 kS\/s sampling, eight DIO lines and two counters.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/pxisource.com\/ru\/product\/pci-6013\/\" \/>\n<meta property=\"og:site_name\" content=\"PXI Source\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=61582573040385\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-10T08:06:44+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/08\/PCI-6013.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"800\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u0426\u0435\u043d\u0430\" \/>\n\t<meta name=\"twitter:data1\" content=\"\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c\" \/>\n\t<meta name=\"twitter:data2\" content=\"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pci-6013\\\/\",\"url\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pci-6013\\\/\",\"name\":\"NI PCI-6013 PCI Multifunction I\\\/O Device 188626-02, In Stock | Project Pricing\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pci-6013\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pci-6013\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/PCI-6013.webp\",\"datePublished\":\"2026-08-25T06:31:54+00:00\",\"dateModified\":\"2026-09-10T08:06:44+00:00\",\"description\":\"The PCI-6013 is a 16-bit PCI multifunction DAQ device with 16 analog inputs, 200 kS\\\/s sampling, eight DIO lines and two counters.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pci-6013\\\/#breadcrumb\"},\"inLanguage\":\"ru-RU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/pxisource.com\\\/product\\\/pci-6013\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pci-6013\\\/#primaryimage\",\"url\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/PCI-6013.webp\",\"contentUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/PCI-6013.webp\",\"width\":800,\"height\":800,\"caption\":\"PCI-6013\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pci-6013\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/pxisource.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\\\/\\\/pxisource.com\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"PCI-6013\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\",\"url\":\"https:\\\/\\\/pxisource.com\\\/\",\"name\":\"PXI Systems\",\"description\":\"NI PXI, PXIe Modular Test Instrument Supplier\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/pxisource.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ru-RU\"}]}<\/script>\n<meta property=\"product:brand\" content=\"National Instruments\" \/>\n<meta property=\"product:price:currency\" content=\"USD\" \/>\n<meta property=\"og:availability\" content=\"instock\" \/>\n<meta property=\"product:availability\" content=\"instock\" \/>\n<meta property=\"product:condition\" content=\"new\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"NI PCI-6013 PCI Multifunction I\/O Device 188626-02, In Stock | Project Pricing","description":"The PCI-6013 is a 16-bit PCI multifunction DAQ device with 16 analog inputs, 200 kS\/s sampling, eight DIO lines and two counters.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/pxisource.com\/ru\/product\/pci-6013\/","og_locale":"ru_RU","og_type":"article","og_title":"PCI-6013","og_description":"The PCI-6013 is a 16-bit PCI multifunction DAQ device with 16 analog inputs, 200 kS\/s sampling, eight DIO lines and two counters.","og_url":"https:\/\/pxisource.com\/ru\/product\/pci-6013\/","og_site_name":"PXI Source","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=61582573040385","article_modified_time":"2026-09-10T08:06:44+00:00","og_image":[{"width":800,"height":800,"url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/08\/PCI-6013.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"\u0426\u0435\u043d\u0430":"","\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c":"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/pxisource.com\/product\/pci-6013\/","url":"https:\/\/pxisource.com\/product\/pci-6013\/","name":"NI PCI-6013 PCI Multifunction I\/O Device 188626-02, In Stock | Project Pricing","isPartOf":{"@id":"https:\/\/pxisource.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/pxisource.com\/product\/pci-6013\/#primaryimage"},"image":{"@id":"https:\/\/pxisource.com\/product\/pci-6013\/#primaryimage"},"thumbnailUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/08\/PCI-6013.webp","datePublished":"2026-08-25T06:31:54+00:00","dateModified":"2026-09-10T08:06:44+00:00","description":"The PCI-6013 is a 16-bit PCI multifunction DAQ device with 16 analog inputs, 200 kS\/s sampling, eight DIO lines and two counters.","breadcrumb":{"@id":"https:\/\/pxisource.com\/product\/pci-6013\/#breadcrumb"},"inLanguage":"ru-RU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/pxisource.com\/product\/pci-6013\/"]}]},{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/pxisource.com\/product\/pci-6013\/#primaryimage","url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/08\/PCI-6013.webp","contentUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/08\/PCI-6013.webp","width":800,"height":800,"caption":"PCI-6013"},{"@type":"BreadcrumbList","@id":"https:\/\/pxisource.com\/product\/pci-6013\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/pxisource.com\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/pxisource.com\/shop\/"},{"@type":"ListItem","position":3,"name":"PCI-6013"}]},{"@type":"WebSite","@id":"https:\/\/pxisource.com\/#website","url":"https:\/\/pxisource.com\/","name":"\u0421\u0438\u0441\u0442\u0435\u043c\u044b PXI","description":"NI PXI, PXIe Modular Test Instrument Supplier","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/pxisource.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ru-RU"}]},"product_brand":"National Instruments","product_price_currency":"USD","og_availability":"instock","product_availability":"instock","product_condition":"new"},"_links":{"self":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/35359","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":3,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/35359\/revisions"}],"predecessor-version":[{"id":36560,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/35359\/revisions\/36560"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media\/35234"}],"wp:attachment":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media?parent=35359"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_brand?post=35359"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_cat?post=35359"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_tag?post=35359"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}