{"id":35283,"date":"2026-08-22T15:24:46","date_gmt":"2026-08-22T07:24:46","guid":{"rendered":"https:\/\/pxisource.com\/?post_type=product&#038;p=35283"},"modified":"2026-09-18T15:03:47","modified_gmt":"2026-09-18T07:03:47","slug":"usb-6259","status":"publish","type":"product","link":"https:\/\/pxisource.com\/ru\/product\/usb-6259\/","title":{"rendered":"USB-6259"},"content":{"rendered":"<h3>USB-6259 High-Performance USB Multifunction DAQ Device<\/h3>\n<p>\u0417\u0435\u043c\u043b\u044f <strong>NI USB-6259<\/strong> is a high-performance M Series multifunction data acquisition device for automated test, laboratory measurement, industrial monitoring and control. It provides an extensive combination of analog input, analog output, digital I\/O and counter resources.<\/p>\n<p>The device includes 32 single-ended or 16 differential analog inputs with 16-bit resolution and a maximum single-channel rate of 1.25 MS\/s. Four high-speed analog outputs and 48 digital I\/O lines support complex stimulus-and-response and test-fixture applications.<\/p>\n<h3>Key Features of the USB-6259<\/h3>\n<ul>\n<li>32 single-ended or 16 differential analog inputs<\/li>\n<li>16-bit analog input resolution<\/li>\n<li>1.25 MS\/s maximum single-channel sampling<\/li>\n<li>1.00 MS\/s aggregate multichannel sampling<\/li>\n<li>Seven input ranges from \u00b10.1 V to \u00b110 V<\/li>\n<li>1.7 MHz small-signal input bandwidth<\/li>\n<li>Four 16-bit analog outputs<\/li>\n<li>High-speed hardware-timed waveform generation<\/li>\n<li>48 individually programmable digital I\/O lines<\/li>\n<li>Up to 32 correlated digital I\/O lines<\/li>\n<li>Two 32-bit counter\/timers<\/li>\n<li>Analog and digital triggering<\/li>\n<li>USB 2.0 Hi-Speed interface<\/li>\n<li>Screw-terminal, BNC, mass-termination and OEM versions<\/li>\n<li>NI-DAQmx compatibility<\/li>\n<\/ul>\n<h2>USB-6259 Technical Specifications<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Product Model<\/th>\n<td>USB-6259<\/td>\n<\/tr>\n<tr>\n<th>Product Family<\/th>\n<td>NI M Series multifunction DAQ<\/td>\n<\/tr>\n<tr>\n<th>Analog Inputs<\/th>\n<td>32 single-ended or 16 differential<\/td>\n<\/tr>\n<tr>\n<th>ADC Resolution<\/th>\n<td>16 bits<\/td>\n<\/tr>\n<tr>\n<th>Single-Channel AI Rate<\/th>\n<td>1.25 MS\/s maximum<\/td>\n<\/tr>\n<tr>\n<th>Multichannel AI Rate<\/th>\n<td>1.00 MS\/s aggregate<\/td>\n<\/tr>\n<tr>\n<th>Input Ranges<\/th>\n<td>\u00b10.1 V, \u00b10.2 V, \u00b10.5 V, \u00b11 V, \u00b12 V, \u00b15 V and \u00b110 V<\/td>\n<\/tr>\n<tr>\n<th>Input Bandwidth<\/th>\n<td>1.7 MHz<\/td>\n<\/tr>\n<tr>\n<th>Analog Outputs<\/th>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th>DAC Resolution<\/th>\n<td>16 bits<\/td>\n<\/tr>\n<tr>\n<th>Analog Output Range<\/th>\n<td>\u00b110 V<\/td>\n<\/tr>\n<tr>\n<th>Maximum AO Rate<\/th>\n<td>Up to approximately 2.86 MS\/s, channel configuration dependent<\/td>\n<\/tr>\n<tr>\n<th>\u0426\u0438\u0444\u0440\u043e\u0432\u043e\u0439 \u0432\u0432\u043e\u0434-\u0432\u044b\u0432\u043e\u0434<\/th>\n<td>48 individually programmable lines<\/td>\n<\/tr>\n<tr>\n<th>Correlated Digital I\/O<\/th>\n<td>Up to 32 hardware-timed lines<\/td>\n<\/tr>\n<tr>\n<th>Counters<\/th>\n<td>2 \u00d7 32-bit<\/td>\n<\/tr>\n<tr>\n<th>USB Interface<\/th>\n<td>USB 2.0 Hi-Speed<\/td>\n<\/tr>\n<tr>\n<th>External Power<\/th>\n<td>Required<\/td>\n<\/tr>\n<tr>\n<th>Connector Options<\/th>\n<td>Screw terminal, BNC, mass termination and OEM<\/td>\n<\/tr>\n<tr>\n<th>Driver<\/th>\n<td>\u041d\u0418-DAQmx<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>USB-6259 Part Number and Accessories<\/h2>\n<p>The USB-6259 is available in several connector configurations. Each version should be treated as a distinct hardware configuration when selecting cables, terminal blocks and mounting hardware.<\/p>\n<table>\n<tbody>\n<tr>\n<th>Configuration or Accessory<\/th>\n<th>\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435<\/th>\n<\/tr>\n<tr>\n<td>USB-6259 Screw Terminal<\/td>\n<td>Integrated terminal access for field and fixture wiring<\/td>\n<\/tr>\n<tr>\n<td>USB-6259 BNC<\/td>\n<td>Direct coaxial access for laboratory measurements<\/td>\n<\/tr>\n<tr>\n<td>USB-6259 Mass Termination<\/td>\n<td>High-density connection for automated test fixtures<\/td>\n<\/tr>\n<tr>\n<td>USB-6259 OEM<\/td>\n<td>Board-level integration into custom systems<\/td>\n<\/tr>\n<tr>\n<td>SHC68-68-EPM Cable<\/td>\n<td>Shielded 68-pin cable for compatible mass-termination connections<\/td>\n<\/tr>\n<tr>\n<td>SCB-68A Connector Block<\/td>\n<td>Shielded screw-terminal signal connection<\/td>\n<\/tr>\n<tr>\n<td>External Power Supply<\/td>\n<td>DC power for the enclosed USB device<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>32 Analog Inputs<\/h3>\n<p>The USB-6259 provides twice the analog input count of the USB-6251 while maintaining the same maximum single-channel sampling performance. It can measure 32 single-ended or 16 differential voltage channels.<\/p>\n<p>Because the inputs share a multiplexed ADC, signals are not sampled at exactly the same instant. Applications requiring simultaneous phase measurements should use a simultaneous-sampling DAQ architecture.<\/p>\n<h3>Four Analog Outputs<\/h3>\n<p>Four hardware-timed analog outputs allow the USB-6259 to generate multiple stimulus signals or control voltages. This is useful for multiaxis experiments, component characterization and automated DUT testing.<\/p>\n<p>Output rate depends on the number of active output channels and waveform configuration. Verify the required aggregate update performance during application design.<\/p>\n<h3>48 Digital I\/O Lines<\/h3>\n<p>The USB-6259 provides 48 programmable digital lines, making it suitable for fixture control, status monitoring and digital communication with compatible logic circuits.<\/p>\n<p>Up to 32 digital lines support correlated input or output using a supplied sample clock. This enables synchronized digital patterns and captured digital waveforms.<\/p>\n<h2>USB-6259 Applications<\/h2>\n<ul>\n<li>Complex automated functional testing<\/li>\n<li>\u041c\u043d\u043e\u0433\u043e\u0446\u0435\u043b\u0435\u0432\u043e\u0435 \u0442\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0430 \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432<\/li>\n<li>Electronic device characterization<\/li>\n<li>High-channel-count data acquisition<\/li>\n<li>Analog stimulus and response systems<\/li>\n<li>Hardware-timed digital control<\/li>\n<li>Research and prototype testing<\/li>\n<li>Encoder and motion measurement<\/li>\n<li>Mixed-signal laboratory automation<\/li>\n<\/ul>\n<h3>Multi-DUT Testing<\/h3>\n<p>Four analog outputs and 48 digital lines allow one USB-6259 to control several fixture functions or DUT interfaces. The analog inputs can then measure multiple response points.<\/p>\n<h3>\u041f\u0440\u043e\u0432\u0435\u0440\u043a\u0430 \u0441\u043c\u0435\u0448\u0430\u043d\u043d\u044b\u0445 \u0441\u0438\u0433\u043d\u0430\u043b\u043e\u0432<\/h3>\n<p>The device can coordinate analog acquisition, waveform generation, digital control and counter measurements through NI-DAQmx hardware timing and triggers.<\/p>\n<h2>USB-6259 Installation Workflow<\/h2>\n<h4>Step 1: Select the Connector Configuration<\/h4>\n<p>Choose screw terminal, BNC or mass termination based on signal density, shielding and fixture design.<\/p>\n<h4>Step 2: Install NI-DAQmx<\/h4>\n<p>Install a compatible driver before connecting the device and developing measurement tasks.<\/p>\n<h4>Step 3: Connect External Power<\/h4>\n<p>Use the specified power supply and verify the connector polarity.<\/p>\n<h4>Step 4: Connect USB<\/h4>\n<p>Connect the device to a Hi-Speed USB port using a short, reliable cable.<\/p>\n<h4>Step 5: Verify Connector Pinouts<\/h4>\n<p>Check the documentation for the exact USB-6259 version. BNC, screw-terminal and mass-termination pin assignments differ.<\/p>\n<h4>Step 6: Test Individual Subsystems<\/h4>\n<p>Validate analog input, analog output, digital I\/O and counters separately before combining them.<\/p>\n<h4>Step 7: Validate Full-System Throughput<\/h4>\n<p>Run the application with the intended channels, rates and waveforms while monitoring buffer and USB transfer performance.<\/p>\n<h2>USB-6259 Troubleshooting<\/h2>\n<h4>The Wrong Channels Appear in Software<\/h4>\n<p>Confirm the exact connector version and physical channel mapping. Do not use a pinout intended for another enclosure.<\/p>\n<h4>The Analog Input Cannot Reach 1.25 MS\/s<\/h4>\n<p>The maximum 1.25 MS\/s rate applies to single-channel operation. Multichannel acquisition is limited by the aggregate rate.<\/p>\n<h4>Digital Waveform Tasks Report Clock Errors<\/h4>\n<p>Configure a compatible sample-clock source. The correlated digital subsystem relies on an external or shared internal clock.<\/p>\n<h4>The USB Buffer Overflows<\/h4>\n<p>Increase application read frequency, reduce task rate, use larger buffers and disable unnecessary background processes.<\/p>\n<h4>Analog Output Waveforms Are Clipped<\/h4>\n<p>Confirm that values remain within the \u00b110 V output range and that the connected load does not exceed the output-current specification.<\/p>\n<h2>USB-6259 Comparison<\/h2>\n<table>\n<tbody>\n<tr>\n<th>\u041c\u043e\u0434\u0435\u043b\u044c<\/th>\n<th>AI Resolution<\/th>\n<th>Analog Inputs<\/th>\n<th>Analog Outputs<\/th>\n<th>\u0426\u0438\u0444\u0440\u043e\u0432\u043e\u0439 \u0432\u0432\u043e\u0434-\u0432\u044b\u0432\u043e\u0434<\/th>\n<\/tr>\n<tr>\n<td>USB-6251<\/td>\n<td>16 bits<\/td>\n<td>16<\/td>\n<td>2<\/td>\n<td>24<\/td>\n<\/tr>\n<tr>\n<td>USB-6255<\/td>\n<td>16 bits<\/td>\n<td>80<\/td>\n<td>2<\/td>\n<td>24<\/td>\n<\/tr>\n<tr>\n<td>USB-6259<\/td>\n<td>16 bits<\/td>\n<td>32<\/td>\n<td>4<\/td>\n<td>48<\/td>\n<\/tr>\n<tr>\n<td>USB-6289<\/td>\n<td>18 bits<\/td>\n<td>32<\/td>\n<td>4<\/td>\n<td>48<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The USB-6259 offers a balanced combination of input channels, analog outputs and digital I\/O. Choose the <a href=\"https:\/\/pxisource.com\/ru\/product\/usb-6289\/\">USB-6289<\/a> when higher 18-bit analog input resolution is more important than maximum acquisition speed.<\/p>\n<h2>USB-6259 Frequently Asked Questions<\/h2>\n<h4>How many analog inputs are available?<\/h4>\n<p>The USB-6259 provides 32 single-ended or 16 differential analog inputs.<\/p>\n<h4>How many analog outputs does it provide?<\/h4>\n<p>It provides four 16-bit analog outputs.<\/p>\n<h4>How many digital lines are available?<\/h4>\n<p>The device provides 48 individually programmable digital I\/O lines.<\/p>\n<h4>Does it support hardware-timed digital I\/O?<\/h4>\n<p>Yes. Up to 32 digital lines can participate in correlated digital input or output operations.<\/p>\n<h4>Is external power required?<\/h4>\n<p>Yes. The enclosed USB-6259 requires an appropriate external DC supply.<\/p>\n<h3>Recommended Related Products<\/h3>\n<ul>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/usb-6251\/\">USB-6251 High-Speed USB DAQ<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/usb-6255\/\">USB-6255 80-Channel USB DAQ<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/usb-6289\/\">USB-6289 18-Bit Multifunction DAQ<\/a><\/li>\n<\/ul>\n<h3>Request a Quote for the USB-6259<\/h3>\n<p>Contact us for current availability, connector selection and project pricing for the <strong>NI USB-6259 high-performance multifunction DAQ device<\/strong>.<\/p>","protected":false},"excerpt":{"rendered":"<p>USB-6259 High-Performance USB Multifunction DAQ Device The NI USB-6259 is a high-performance M Series multifunction data acquisition device for automated<\/p>","protected":false},"featured_media":35270,"template":"","meta":{"_acf_changed":false},"product_brand":[18],"product_cat":[674,800],"product_tag":[],"class_list":["post-35283","product","type-product","status-publish","has-post-thumbnail","product_brand-national-instruments","product_cat-pci-modules","product_cat-usb-devices","first","instock","shipping-taxable","product-type-simple"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.0 (Yoast SEO v28.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>NI USB-6259 USB Multifunction I\/O Device 779628-02, In Stock | Project Pricing<\/title>\n<meta name=\"description\" content=\"The USB-6259 is a high-performance USB DAQ device with 32 analog inputs, four analog outputs, 48 DIO lines and two 32-bit counters.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/pxisource.com\/ru\/product\/usb-6259\/\" \/>\n<meta property=\"og:locale\" content=\"ru_RU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"USB-6259\" \/>\n<meta property=\"og:description\" content=\"The USB-6259 is a high-performance USB DAQ device with 32 analog inputs, four analog outputs, 48 DIO lines and two 32-bit counters.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/pxisource.com\/ru\/product\/usb-6259\/\" \/>\n<meta property=\"og:site_name\" content=\"PXI Source\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=61582573040385\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-18T07:03:47+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/08\/USB-6259.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"800\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u0426\u0435\u043d\u0430\" \/>\n\t<meta name=\"twitter:data1\" content=\"\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c\" \/>\n\t<meta name=\"twitter:data2\" content=\"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/usb-6259\\\/\",\"url\":\"https:\\\/\\\/pxisource.com\\\/product\\\/usb-6259\\\/\",\"name\":\"NI USB-6259 USB Multifunction I\\\/O Device 779628-02, In Stock | Project Pricing\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/usb-6259\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/usb-6259\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/USB-6259.webp\",\"datePublished\":\"2026-08-22T07:24:46+00:00\",\"dateModified\":\"2026-09-18T07:03:47+00:00\",\"description\":\"The USB-6259 is a high-performance USB DAQ device with 32 analog inputs, four analog outputs, 48 DIO lines and two 32-bit counters.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/usb-6259\\\/#breadcrumb\"},\"inLanguage\":\"ru-RU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/pxisource.com\\\/product\\\/usb-6259\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/usb-6259\\\/#primaryimage\",\"url\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/USB-6259.webp\",\"contentUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/USB-6259.webp\",\"width\":800,\"height\":800,\"caption\":\"USB-6259\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/usb-6259\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/pxisource.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\\\/\\\/pxisource.com\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"USB-6259\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\",\"url\":\"https:\\\/\\\/pxisource.com\\\/\",\"name\":\"PXI Systems\",\"description\":\"NI PXI, PXIe Modular Test Instrument Supplier\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/pxisource.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ru-RU\"}]}<\/script>\n<meta property=\"product:brand\" content=\"National Instruments\" \/>\n<meta property=\"product:price:currency\" content=\"USD\" \/>\n<meta property=\"og:availability\" content=\"instock\" \/>\n<meta property=\"product:availability\" content=\"instock\" \/>\n<meta property=\"product:condition\" content=\"new\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"NI USB-6259 USB Multifunction I\/O Device 779628-02, In Stock | Project Pricing","description":"The USB-6259 is a high-performance USB DAQ device with 32 analog inputs, four analog outputs, 48 DIO lines and two 32-bit counters.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/pxisource.com\/ru\/product\/usb-6259\/","og_locale":"ru_RU","og_type":"article","og_title":"USB-6259","og_description":"The USB-6259 is a high-performance USB DAQ device with 32 analog inputs, four analog outputs, 48 DIO lines and two 32-bit counters.","og_url":"https:\/\/pxisource.com\/ru\/product\/usb-6259\/","og_site_name":"PXI Source","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=61582573040385","article_modified_time":"2026-09-18T07:03:47+00:00","og_image":[{"width":800,"height":800,"url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/08\/USB-6259.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"\u0426\u0435\u043d\u0430":"","\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c":"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/pxisource.com\/product\/usb-6259\/","url":"https:\/\/pxisource.com\/product\/usb-6259\/","name":"NI USB-6259 USB Multifunction I\/O Device 779628-02, In Stock | Project Pricing","isPartOf":{"@id":"https:\/\/pxisource.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/pxisource.com\/product\/usb-6259\/#primaryimage"},"image":{"@id":"https:\/\/pxisource.com\/product\/usb-6259\/#primaryimage"},"thumbnailUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/08\/USB-6259.webp","datePublished":"2026-08-22T07:24:46+00:00","dateModified":"2026-09-18T07:03:47+00:00","description":"The USB-6259 is a high-performance USB DAQ device with 32 analog inputs, four analog outputs, 48 DIO lines and two 32-bit counters.","breadcrumb":{"@id":"https:\/\/pxisource.com\/product\/usb-6259\/#breadcrumb"},"inLanguage":"ru-RU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/pxisource.com\/product\/usb-6259\/"]}]},{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/pxisource.com\/product\/usb-6259\/#primaryimage","url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/08\/USB-6259.webp","contentUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/08\/USB-6259.webp","width":800,"height":800,"caption":"USB-6259"},{"@type":"BreadcrumbList","@id":"https:\/\/pxisource.com\/product\/usb-6259\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/pxisource.com\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/pxisource.com\/shop\/"},{"@type":"ListItem","position":3,"name":"USB-6259"}]},{"@type":"WebSite","@id":"https:\/\/pxisource.com\/#website","url":"https:\/\/pxisource.com\/","name":"\u0421\u0438\u0441\u0442\u0435\u043c\u044b PXI","description":"NI PXI, PXIe Modular Test Instrument Supplier","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/pxisource.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ru-RU"}]},"product_brand":"National Instruments","product_price_currency":"USD","og_availability":"instock","product_availability":"instock","product_condition":"new"},"_links":{"self":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/35283","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":3,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/35283\/revisions"}],"predecessor-version":[{"id":36340,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/35283\/revisions\/36340"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media\/35270"}],"wp:attachment":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media?parent=35283"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_brand?post=35283"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_cat?post=35283"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_tag?post=35283"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}