{"id":34892,"date":"2026-08-08T16:44:25","date_gmt":"2026-08-08T08:44:25","guid":{"rendered":"https:\/\/pxisource.com\/?post_type=product&#038;p=34892"},"modified":"2026-08-31T15:55:39","modified_gmt":"2026-08-31T07:55:39","slug":"pxi-2557","status":"publish","type":"product","link":"https:\/\/pxisource.com\/ru\/product\/pxi-2557\/","title":{"rendered":"PXI-2557"},"content":{"rendered":"<h3>PXI-2557 8\u00d71 2.5 GHz 75 \u03a9 PXI RF Multiplexer<\/h3>\n<p>\u0417\u0435\u043c\u043b\u044f <strong>PXI-2557<\/strong> is a high-density PXI RF multiplexer designed to route one of eight 75 \u03a9 RF or video signals to a single common connection. Its 8\u00d71 topology, DC to 2.5 GHz operating range and electromechanical relay architecture make it suitable for cable television, video, tuner, communications and automated RF test systems.<\/p>\n<p>The module combines eight input channels and one common connection in a single-slot PXI instrument. It provides low insertion loss, good isolation and controlled 75 \u03a9 impedance for test systems that need to connect several devices or signal sources to one RF analyzer, digitizer or other measurement instrument.<\/p>\n<h3>Key Features of the PXI-2557<\/h3>\n<ul>\n<li>Single 8\u00d71 RF multiplexer topology<\/li>\n<li>Eight input channels and one common connection<\/li>\n<li>DC to 2.5 GHz operating frequency range<\/li>\n<li>75 \u03a9 characteristic impedance<\/li>\n<li>Electromechanical latching relays<\/li>\n<li>Less than 1.1 dB insertion loss through 1 GHz<\/li>\n<li>Less than 2.0 dB insertion loss through 2.5 GHz<\/li>\n<li>Greater than 41 dB typical isolation through 2.5 GHz<\/li>\n<li>10 W maximum RF switching power<\/li>\n<li>30 V maximum switching voltage<\/li>\n<li>0.5 A maximum switching and carry current<\/li>\n<li>Less than 25 ps typical channel-to-channel skew<\/li>\n<li>1.2 ns typical propagation delay<\/li>\n<li>10.4 ms maximum relay operating time<\/li>\n<li>Onboard relay-count tracking<\/li>\n<li>PXI hardware trigger support<\/li>\n<li>NI-SWITCH software compatibility<\/li>\n<li>Single-slot 3U PXI module<\/li>\n<\/ul>\n<h3>PXI-2557 Technical Specifications<\/h3>\n<table>\n<tbody>\n<tr>\n<th>Product Model<\/th>\n<td>PXI-2557<\/td>\n<\/tr>\n<tr>\n<th>Part Number<\/th>\n<td>778572-57<\/td>\n<\/tr>\n<tr>\n<th>Product Type<\/th>\n<td>PXI RF multiplexer switch module<\/td>\n<\/tr>\n<tr>\n<th>Topology<\/th>\n<td>Single 8\u00d71 multiplexer<\/td>\n<\/tr>\n<tr>\n<th>Termination<\/th>\n<td>Unterminated<\/td>\n<\/tr>\n<tr>\n<th>Number of Input Channels<\/th>\n<td>8<\/td>\n<\/tr>\n<tr>\n<th>Number of Common Connections<\/th>\n<td>1<\/td>\n<\/tr>\n<tr>\n<th>\u0414\u0438\u0430\u043f\u0430\u0437\u043e\u043d \u0447\u0430\u0441\u0442\u043e\u0442<\/th>\n<td>DC to 2.5 GHz<\/td>\n<\/tr>\n<tr>\n<th>Characteristic Impedance<\/th>\n<td>75 \u03a9<\/td>\n<\/tr>\n<tr>\n<th>Maximum Insertion Loss through 1 GHz<\/th>\n<td>Less than 1.1 dB<\/td>\n<\/tr>\n<tr>\n<th>Maximum Insertion Loss through 2.5 GHz<\/th>\n<td>Less than 2.0 dB<\/td>\n<\/tr>\n<tr>\n<th>Typical Isolation through 1 GHz<\/th>\n<td>Greater than 48 dB<\/td>\n<\/tr>\n<tr>\n<th>Typical Isolation through 2.5 GHz<\/th>\n<td>Greater than 41 dB<\/td>\n<\/tr>\n<tr>\n<th>Maximum VSWR through 1 GHz<\/th>\n<td>Less than 1.25<\/td>\n<\/tr>\n<tr>\n<th>Maximum VSWR through 2.5 GHz<\/th>\n<td>Less than 1.6<\/td>\n<\/tr>\n<tr>\n<th>Maximum Switching Voltage<\/th>\n<td>30 V<\/td>\n<\/tr>\n<tr>\n<th>Maximum Switching Current<\/th>\n<td>0,5 \u0410 \u043d\u0430 \u043a\u0430\u043d\u0430\u043b<\/td>\n<\/tr>\n<tr>\n<th>Maximum Carry Current<\/th>\n<td>0,5 \u0410 \u043d\u0430 \u043a\u0430\u043d\u0430\u043b<\/td>\n<\/tr>\n<tr>\n<th>Maximum RF Switching Power<\/th>\n<td>10 W from channel to common<\/td>\n<\/tr>\n<tr>\n<th>Typical Initial DC Path Resistance<\/th>\n<td>Less than 0.35 \u03a9<\/td>\n<\/tr>\n<tr>\n<th>Typical Channel-to-Channel Skew<\/th>\n<td>Less than 25 ps<\/td>\n<\/tr>\n<tr>\n<th>Typical Propagation Delay<\/th>\n<td>1.2 ns<\/td>\n<\/tr>\n<tr>\n<th>Typical Rise Time<\/th>\n<td>91 ps<\/td>\n<\/tr>\n<tr>\n<th>Maximum Relay Operate Time<\/th>\n<td>10.4 ms<\/td>\n<\/tr>\n<tr>\n<th>\u0422\u0438\u043f \u0440\u0435\u043b\u0435<\/th>\n<td>Electromechanical latching<\/td>\n<\/tr>\n<tr>\n<th>Mechanical Relay Life<\/th>\n<td>1,000,000 cycles<\/td>\n<\/tr>\n<tr>\n<th>Input Trigger Sources<\/th>\n<td>PXI trigger lines 0 through 7<\/td>\n<\/tr>\n<tr>\n<th>Minimum Trigger Pulse Width<\/th>\n<td>150 ns<\/td>\n<\/tr>\n<tr>\n<th>Front-Panel Connections<\/th>\n<td>9 mini-75 \u03a9 SMB jacks<\/td>\n<\/tr>\n<tr>\n<th>Operating Temperature<\/th>\n<td>0\u00b0C to 55\u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Module Format<\/th>\n<td>3U, single-slot PXI module<\/td>\n<\/tr>\n<tr>\n<th>\u041f\u043e\u0434\u0434\u0435\u0440\u0436\u043a\u0430 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f<\/th>\n<td>NI-SWITCH and NI Switch Executive<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>PXI-2557 Part Number and Accessories<\/h3>\n<table>\n<tbody>\n<tr>\n<th>Item<\/th>\n<th>Part Number<\/th>\n<th>\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435<\/th>\n<\/tr>\n<tr>\n<td>PXI-2557<\/td>\n<td>778572-57<\/td>\n<td>2.5 GHz, 75 \u03a9, 8\u00d71 PXI RF multiplexer module<\/td>\n<\/tr>\n<tr>\n<td>Mini-75 \u03a9 SMB Plug-to-Plug Cable<\/td>\n<td>197211-0R3<\/td>\n<td>0.3 m cable for short 75 \u03a9 RF connections<\/td>\n<\/tr>\n<tr>\n<td>Mini-75 \u03a9 SMB Plug-to-Plug Cable<\/td>\n<td>197211-01<\/td>\n<td>1 m cable for 75 \u03a9 RF system integration<\/td>\n<\/tr>\n<tr>\n<td>Type-F Female to Mini-75 \u03a9 SMB Plug Cable<\/td>\n<td>197210-0R3<\/td>\n<td>0.3 m adapter cable for Type-F RF equipment<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The PXI-2557 uses miniature 75 \u03a9 SMB front-panel connections. Confirm the connector type, cable length, impedance and frequency rating before selecting cables or designing a test fixture.<\/p>\n<h3>8\u00d71 RF Multiplexer Architecture<\/h3>\n<p>The PXI-2557 contains one common connection and eight independently selectable input channels. Software can connect any one of the eight channels to the common port, allowing several RF sources or devices under test to share a single instrument.<\/p>\n<p>A typical system connects the common port to an RF analyzer, digitizer or measurement receiver. Each channel can then be connected to a separate tuner, video source, cable assembly or device under test. Test software selects the required channel without manual cable changes.<\/p>\n<p>The multiplexer is normally operated with one channel connected to the common at a time. Applications should avoid creating unintended signal conflicts between multiple sources and should remain within the module\u2019s RF power, voltage and current ratings.<\/p>\n<h3>75 \u03a9 RF and Video Signal Routing<\/h3>\n<p>The PXI-2557 is designed for 75 \u03a9 environments commonly used in cable television, video distribution and broadcast test systems. Maintaining the correct impedance helps reduce reflections and measurement errors throughout the RF signal path.<\/p>\n<p>All external components should also maintain 75 \u03a9 impedance, including cables, adapters, connectors, fixtures and instrument inputs. Mixing 50 \u03a9 and 75 \u03a9 components can increase mismatch loss and degrade VSWR performance.<\/p>\n<h3>DC to 2.5 GHz Frequency Range<\/h3>\n<p>The module supports signals from DC through 2.5 GHz. This frequency range accommodates baseband video, intermediate-frequency signals, television and cable bands, tuner test signals and other broadband 75 \u03a9 applications.<\/p>\n<p>Overall system bandwidth depends on more than the switch module. Cable length, connector quality, adapters, fixture layout, source impedance and load impedance can all affect high-frequency performance.<\/p>\n<h3>Insertion Loss Performance<\/h3>\n<p>The PXI-2557 specifies less than 1.1 dB insertion loss through 1 GHz and less than 2.0 dB through 2.5 GHz. Low insertion loss helps preserve signal amplitude between the selected input and common connection.<\/p>\n<p>For accurate RF measurements, characterize the complete signal path and compensate for cable and switch losses where necessary. Calibration should be performed using the same cables, adapters and routing configuration employed during testing.<\/p>\n<h3>RF Isolation<\/h3>\n<p>Typical channel isolation is greater than 48 dB through 1 GHz and greater than 41 dB through 2.5 GHz. Isolation reduces leakage from unselected channels into the active measurement path.<\/p>\n<p>System-level isolation can be affected by external cables, connector spacing, fixture shielding and grounding. Keep sensitive signal paths separated from high-power RF sources and use properly shielded 75 \u03a9 cabling.<\/p>\n<h3>VSWR and Impedance Matching<\/h3>\n<p>The PXI-2557 provides a maximum VSWR below 1.25 through 1 GHz and below 1.6 through 2.5 GHz. These ratings help limit reflections when the module is connected to properly matched 75 \u03a9 equipment.<\/p>\n<p>Unused channels in the unterminated multiplexer are not internally connected to matched loads. If the test architecture requires defined termination on unselected inputs, provide suitable external 75 \u03a9 terminations or consider a terminated RF switch configuration.<\/p>\n<h3>10 W RF Power Capability<\/h3>\n<p>The maximum RF switching power from a channel to the common connection is 10 W. The applied signal must also remain within the module\u2019s 30 V maximum switching voltage and 0.5 A maximum current ratings.<\/p>\n<p>RF power limits can vary with frequency, load mismatch and switching conditions. Avoid operating the relays while high-power RF energy is present whenever possible because cold switching generally reduces contact stress and extends relay life.<\/p>\n<h3>Electromechanical Latching Relays<\/h3>\n<p>The PXI-2557 uses electromechanical latching relays. Latching operation allows a relay to maintain its selected state without continuous coil power, helping reduce internal heat generation.<\/p>\n<p>Electromechanical relays provide a broadband signal path extending to DC, but relay contacts have a finite service life. Switching high-power, capacitive or active signals can shorten electrical life compared with low-level cold-switching operation.<\/p>\n<h3>Relay-Count Tracking<\/h3>\n<p>Onboard relay-count tracking records the number of operations performed by each relay. This information helps users monitor channel utilization and plan preventive maintenance in production and laboratory test systems.<\/p>\n<p>Frequently used routes can be identified before relay wear affects test reliability. Where the fixture design permits, switching activity can be distributed across channels to balance relay usage.<\/p>\n<h3>Hardware Triggering and Automated Scanning<\/h3>\n<p>The PXI-2557 can accept hardware triggers from PXI trigger lines 0 through 7. Hardware triggering allows route changes to be coordinated with digitizers, RF instruments and other modules in an automated PXI test system.<\/p>\n<p>Trigger-controlled scanning can provide more repeatable timing than software commands alone. The complete sequence should allow sufficient time for relay operation, signal settling and instrument acquisition.<\/p>\n<h3>Typical PXI-2557 Applications<\/h3>\n<ul>\n<li>Cable television tuner testing<\/li>\n<li>Broadcast video test systems<\/li>\n<li>75 \u03a9 RF signal routing<\/li>\n<li>Automated tuner validation<\/li>\n<li>Set-top box production testing<\/li>\n<li>Video distribution equipment testing<\/li>\n<li>RF analyzer input selection<\/li>\n<li>Broadband signal-source selection<\/li>\n<li>Cable and connector testing<\/li>\n<li>Communications equipment validation<\/li>\n<li>Laboratory RF automation<\/li>\n<li>Production functional testing<\/li>\n<\/ul>\n<h3>Multiple-Tuner Test Systems<\/h3>\n<p>The 8\u00d71 topology is well suited for test systems that connect several video or cable tuners to one RF analyzer. Software can select each device sequentially, perform the required measurements and record the results without moving cables.<\/p>\n<p>This configuration helps improve equipment utilization because one measurement instrument can serve as many as eight test paths. Additional PXI-2557 modules can be installed when a system requires more than eight inputs.<\/p>\n<h3>RF Analyzer and Digitizer Integration<\/h3>\n<p>The common connection can be routed to a 75 \u03a9 RF analyzer, digitizer, receiver or other measurement instrument. Each channel can connect to a separate source, output or test fixture path.<\/p>\n<p>When the receiving instrument uses a 50 \u03a9 input, an appropriate impedance-matching device may be required. A simple connector adapter changes the physical interface but does not convert the electrical impedance.<\/p>\n<h3>NI-SWITCH Software Support<\/h3>\n<p>The PXI-2557 is controlled through the NI-SWITCH instrument driver. NI-SWITCH provides functions for initializing the module, connecting and disconnecting routes, creating scan lists, configuring triggers and retrieving relay-count information.<\/p>\n<p>The driver can be used with LabVIEW, LabWindows\/CVI and supported text-based programming environments. Test applications can select RF paths programmatically as part of automated measurement sequences.<\/p>\n<h3>NI Switch Executive Integration<\/h3>\n<p>NI Switch Executive allows developers to assign meaningful names to channels and routes. Instead of managing physical relay names directly, application software can connect routes representing devices, instruments or fixture locations.<\/p>\n<p>Named routes are particularly useful in systems containing several RF switch modules. They make test sequences easier to understand and help separate application logic from physical wiring details.<\/p>\n<h3>PXI Chassis Integration<\/h3>\n<p>The PXI-2557 is a single-slot 3U PXI module. It can be installed with RF analyzers, digitizers, signal generators, digital instruments and other PXI modules to create a compact automated test system.<\/p>\n<p>Before installation, verify chassis compatibility, slot availability, controller support and the required NI-SWITCH driver version. Allow sufficient front-panel clearance for all nine RF connectors and avoid excessive bending force on miniature SMB cables.<\/p>\n<h3>PXI-2557 Troubleshooting<\/h3>\n<h4>The PXI-2557 Is Not Detected in NI MAX<\/h4>\n<p>Confirm that the module is fully seated in a compatible PXI slot. Check chassis power, controller communication and NI-SWITCH installation, then restart NI Measurement &amp; Automation Explorer and rescan the system.<\/p>\n<h4>No Signal Appears at the Common Port<\/h4>\n<p>Verify that the correct channel-to-common route is closed. Check cable continuity, connector seating, source output and analyzer configuration. Confirm that the channel names in the software correspond to the physical front-panel connections.<\/p>\n<h4>Insertion Loss Is Higher Than Expected<\/h4>\n<p>Inspect every cable, adapter and connector in the signal path. Confirm that all components have 75 \u03a9 impedance and adequate bandwidth. Damaged connectors, long cables and 50 \u03a9 components can increase measured loss.<\/p>\n<h4>Signal Reflections or Poor VSWR Occur<\/h4>\n<p>Confirm that the source, load, cables and terminations are all designed for 75 \u03a9 operation. Remove unnecessary adapters and keep cables as short as practical. Add external 75 \u03a9 terminations where required by the test configuration.<\/p>\n<h4>Signals Leak Between Channels<\/h4>\n<p>Check external fixture shielding, cable routing and grounding. Separate high-level RF sources from sensitive measurement paths and verify that unselected sources are not coupling through external wiring.<\/p>\n<h4>A Relay Does Not Change State<\/h4>\n<p>Check the route command, relay status and relay-count data. Disconnect the external circuit and test the channel with a known signal path. If the fault remains, the relay may require service after extensive use or operation beyond its ratings.<\/p>\n<h4>Relay Life Is Shorter Than Expected<\/h4>\n<p>Avoid switching while RF power is present. Verify that the signal remains below the voltage, current and power limits, and check for capacitive discharge or transient energy. Cold switching typically provides longer contact life.<\/p>\n<h4>High-Frequency Measurements Are Inconsistent<\/h4>\n<p>Use stable RF cables, minimize movement and allow the measurement system to settle after each route change. Perform path calibration with the switch, cables and adapters in their final configuration.<\/p>\n<h3>PXI-2557 Comparison with Similar RF Switches<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u041c\u043e\u0434\u0435\u043b\u044c<\/th>\n<th>\u041a\u043e\u043d\u0444\u0438\u0433\u0443\u0440\u0430\u0446\u0438\u044f<\/th>\n<th>Best Suited For<\/th>\n<\/tr>\n<tr>\n<td>PXI-2554<\/td>\n<td>2.5 GHz, 75 \u03a9, unterminated 4\u00d71<\/td>\n<td>Basic four-channel RF multiplexing<\/td>\n<\/tr>\n<tr>\n<td>PXI-2555<\/td>\n<td>2.5 GHz, 75 \u03a9, terminated 4\u00d71<\/td>\n<td>Applications requiring terminated unselected channels<\/td>\n<\/tr>\n<tr>\n<td>PXI-2556<\/td>\n<td>2.5 GHz, 75 \u03a9, dual 4\u00d71<\/td>\n<td>Two independent four-channel multiplexers<\/td>\n<\/tr>\n<tr>\n<td>PXI-2557<\/td>\n<td>2.5 GHz, 75 \u03a9, unterminated 8\u00d71<\/td>\n<td>Connecting eight RF paths to one instrument<\/td>\n<\/tr>\n<tr>\n<td>PXI-2558<\/td>\n<td>2.5 GHz, 75 \u03a9, quad SPDT<\/td>\n<td>Four independent changeover switches<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>PXI-2557 vs PXI-2554<\/h3>\n<p>The PXI-2557 provides a single 8\u00d71 multiplexer, while the <a href=\"https:\/\/pxisource.com\/ru\/product\/pxi-2554\/\">PXI-2554<\/a> provides a single 4\u00d71 multiplexer. Both modules support 75 \u03a9 signals through 2.5 GHz and use unterminated RF switch architectures.<\/p>\n<p>Choose the PXI-2557 when one instrument must select among as many as eight signals. Choose the PXI-2554 when four input paths are sufficient and fewer front-panel connections are preferred.<\/p>\n<h3>PXI-2557 vs PXI-2555<\/h3>\n<p>The PXI-2557 offers eight unterminated inputs, while the <a href=\"https:\/\/pxisource.com\/ru\/product\/pxi-2555\/\">PXI-2555<\/a> provides a terminated 4\u00d71 configuration. Internal termination can help control the impedance presented by unselected channels in certain RF systems.<\/p>\n<p>Select the PXI-2557 for greater channel density. Select the PXI-2555 when four channels are sufficient and matched termination of unselected paths is important.<\/p>\n<h3>PXI-2557 vs PXI-2556<\/h3>\n<p>The PXI-2557 contains one 8\u00d71 multiplexer, while the <a href=\"https:\/\/pxisource.com\/ru\/product\/pxi-2556\/\">PXI-2556<\/a> contains two independent 4\u00d71 multiplexers. Both provide eight total input channels, but their routing architectures serve different requirements.<\/p>\n<p>Choose the PXI-2557 when all eight signals must share one common instrument connection. Choose the PXI-2556 when the system needs two independent groups connected to two separate common ports.<\/p>\n<h3>Recommended Related Products<\/h3>\n<ul>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxi-2554\/\">PXI-2554 4\u00d71 75 \u03a9 RF Multiplexer<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxi-2555\/\">PXI-2555 Terminated 4\u00d71 75 \u03a9 RF Multiplexer<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxi-2556\/\">PXI-2556 Dual 4\u00d71 75 \u03a9 RF Multiplexer<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxi-2558\/\">PXI-2558 Quad SPDT 75 \u03a9 RF Switch<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxi-2559\/\">PXI-2559 75 \u03a9 RF Switch Module<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product-category\/%d0%bd%d0%b8\/pxi-%d1%81%d0%b8%d1%81%d1%82%d0%b5%d0%bc%d1%81\/%d0%bc%d0%be%d0%b4%d1%83%d0%bb%d0%b8-pxi\/\">View More NI PXI and PXI Express Modules<\/a><\/li>\n<\/ul>\n<h3>Selecting the Right 75 \u03a9 RF Switch<\/h3>\n<p>Choose the PXI-2557 when the test system requires a single common instrument to access as many as eight 75 \u03a9 RF or video paths. Its 8\u00d71 architecture provides greater input density than the 4\u00d71 PXI-2554 and PXI-2555.<\/p>\n<p>Select the PXI-2556 when two independent 4\u00d71 multiplexers are required. Consider the PXI-2558 when the application requires multiple independent SPDT changeover switches rather than one multiplexer.<\/p>\n<h3>Why Choose the PXI-2557?<\/h3>\n<ul>\n<li>Routes eight 75 \u03a9 RF signals to one common connection<\/li>\n<li>Supports signals from DC through 2.5 GHz<\/li>\n<li>Provides low insertion loss and good RF isolation<\/li>\n<li>Offers higher input density than a 4\u00d71 multiplexer<\/li>\n<li>Supports cable, video and tuner test applications<\/li>\n<li>Handles up to 10 W of RF switching power<\/li>\n<li>Includes onboard relay-count tracking<\/li>\n<li>Supports PXI hardware triggering<\/li>\n<li>Integrates with NI-SWITCH and NI Switch Executive<\/li>\n<\/ul>\n<h3>Frequently Asked Questions<\/h3>\n<h4>What Is the PXI-2557?<\/h4>\n<p>The PXI-2557 is a 75 \u03a9, 8\u00d71 PXI RF multiplexer that routes one of eight input channels to a single common connection over a DC to 2.5 GHz frequency range.<\/p>\n<h4>What Is the PXI-2557 Part Number?<\/h4>\n<p>The standard NI part number for the PXI-2557 is <strong>778572-57<\/strong>.<\/p>\n<h4>How Many Channels Does the PXI-2557 Provide?<\/h4>\n<p>The module provides eight input channels and one common connection in a single 8\u00d71 multiplexer topology.<\/p>\n<h4>Is the PXI-2557 a 50 \u03a9 or 75 \u03a9 Switch?<\/h4>\n<p>The PXI-2557 is designed for 75 \u03a9 RF and video systems. Its cables, adapters, sources and measurement instruments should also use 75 \u03a9 impedance whenever possible.<\/p>\n<h4>What Is the Maximum Frequency?<\/h4>\n<p>The PXI-2557 supports signals from DC through 2.5 GHz.<\/p>\n<h4>What Is the Maximum RF Power?<\/h4>\n<p>The maximum RF switching power is 10 W from a channel to the common connection, subject to the module\u2019s voltage, current, frequency and load restrictions.<\/p>\n<h4>Are Unselected Channels Terminated?<\/h4>\n<p>No. The PXI-2557 uses an unterminated 8\u00d71 architecture. External 75 \u03a9 termination should be provided if required by the application.<\/p>\n<h4>What Type of Relays Does It Use?<\/h4>\n<p>The PXI-2557 uses electromechanical latching relays that provide broadband operation extending to DC.<\/p>\n<h4>Does the PXI-2557 Track Relay Usage?<\/h4>\n<p>Yes. Onboard relay-count tracking records switching activity and can support preventive maintenance planning.<\/p>\n<h4>Which Software Controls the PXI-2557?<\/h4>\n<p>The module is controlled through NI-SWITCH and can be integrated into named-route systems using NI Switch Executive.<\/p>\n<h4>Is the PXI-2557 Still Available from NI?<\/h4>\n<p>NI lists the PXI-2557 as discontinued and no longer available for direct purchase. Used or refurbished modules may remain available from specialized PXI equipment suppliers.<\/p>\n<h3>Request a Quote for the PXI-2557<\/h3>\n<p>Contact us for current availability, condition, lead time and project pricing for the <strong>PXI-2557 8\u00d71 2.5 GHz 75 \u03a9 PXI RF Multiplexer<\/strong>. We can also help identify compatible mini-75 \u03a9 SMB cables, PXI chassis and alternative 75 \u03a9 RF switch modules for your test system.<\/p>","protected":false},"excerpt":{"rendered":"<p>PXI-2557 8\u00d71 2.5 GHz 75 \u03a9 PXI RF Multiplexer The PXI-2557 is a high-density PXI RF multiplexer designed to route<\/p>","protected":false},"featured_media":34815,"template":"","meta":{"_acf_changed":false},"product_brand":[18],"product_cat":[667],"product_tag":[],"class_list":["post-34892","product","type-product","status-publish","has-post-thumbnail","product_brand-national-instruments","product_cat-pxi-modules","first","instock","shipping-taxable","product-type-simple"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.0 (Yoast SEO v28.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>NI PXI-2557 PXI RF Multiplexer Switch Module 778572-57, In Stock | Project Pricing<\/title>\n<meta name=\"description\" content=\"The PXI-2557 is a 2.5 GHz, 75 \u03a9, 8\u00d71 PXI RF multiplexer for routing eight RF or video signals to one analyzer or measurement channel.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/pxisource.com\/ru\/product\/pxi-2557\/\" \/>\n<meta property=\"og:locale\" content=\"ru_RU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"PXI-2557\" \/>\n<meta property=\"og:description\" content=\"The PXI-2557 is a 2.5 GHz, 75 \u03a9, 8\u00d71 PXI RF multiplexer for routing eight RF or video signals to one analyzer or measurement channel.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/pxisource.com\/ru\/product\/pxi-2557\/\" \/>\n<meta property=\"og:site_name\" content=\"PXI Source\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=61582573040385\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-31T07:55:39+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/08\/PXI-2557.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"800\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u0426\u0435\u043d\u0430\" \/>\n\t<meta name=\"twitter:data1\" content=\"\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c\" \/>\n\t<meta name=\"twitter:data2\" content=\"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxi-2557\\\/\",\"url\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxi-2557\\\/\",\"name\":\"NI PXI-2557 PXI RF Multiplexer Switch Module 778572-57, In Stock | Project Pricing\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxi-2557\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxi-2557\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/PXI-2557.webp\",\"datePublished\":\"2026-08-08T08:44:25+00:00\",\"dateModified\":\"2026-08-31T07:55:39+00:00\",\"description\":\"The PXI-2557 is a 2.5 GHz, 75 \u03a9, 8\u00d71 PXI RF multiplexer for routing eight RF or video signals to one analyzer or measurement channel.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxi-2557\\\/#breadcrumb\"},\"inLanguage\":\"ru-RU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/pxisource.com\\\/product\\\/pxi-2557\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxi-2557\\\/#primaryimage\",\"url\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/PXI-2557.webp\",\"contentUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/PXI-2557.webp\",\"width\":800,\"height\":800,\"caption\":\"PXI-2557\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxi-2557\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/pxisource.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\\\/\\\/pxisource.com\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"PXI-2557\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\",\"url\":\"https:\\\/\\\/pxisource.com\\\/\",\"name\":\"PXI Systems\",\"description\":\"NI PXI, PXIe Modular Test Instrument Supplier\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/pxisource.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ru-RU\"}]}<\/script>\n<meta property=\"product:brand\" content=\"National Instruments\" \/>\n<meta property=\"product:price:currency\" content=\"USD\" \/>\n<meta property=\"og:availability\" content=\"instock\" \/>\n<meta property=\"product:availability\" content=\"instock\" \/>\n<meta property=\"product:condition\" content=\"new\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"NI PXI-2557 PXI RF Multiplexer Switch Module 778572-57, In Stock | Project Pricing","description":"The PXI-2557 is a 2.5 GHz, 75 \u03a9, 8\u00d71 PXI RF multiplexer for routing eight RF or video signals to one analyzer or measurement channel.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/pxisource.com\/ru\/product\/pxi-2557\/","og_locale":"ru_RU","og_type":"article","og_title":"PXI-2557","og_description":"The PXI-2557 is a 2.5 GHz, 75 \u03a9, 8\u00d71 PXI RF multiplexer for routing eight RF or video signals to one analyzer or measurement channel.","og_url":"https:\/\/pxisource.com\/ru\/product\/pxi-2557\/","og_site_name":"PXI Source","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=61582573040385","article_modified_time":"2026-08-31T07:55:39+00:00","og_image":[{"width":800,"height":800,"url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/08\/PXI-2557.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"\u0426\u0435\u043d\u0430":"","\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c":"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/pxisource.com\/product\/pxi-2557\/","url":"https:\/\/pxisource.com\/product\/pxi-2557\/","name":"NI PXI-2557 PXI RF Multiplexer Switch Module 778572-57, In Stock | Project Pricing","isPartOf":{"@id":"https:\/\/pxisource.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/pxisource.com\/product\/pxi-2557\/#primaryimage"},"image":{"@id":"https:\/\/pxisource.com\/product\/pxi-2557\/#primaryimage"},"thumbnailUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/08\/PXI-2557.webp","datePublished":"2026-08-08T08:44:25+00:00","dateModified":"2026-08-31T07:55:39+00:00","description":"The PXI-2557 is a 2.5 GHz, 75 \u03a9, 8\u00d71 PXI RF multiplexer for routing eight RF or video signals to one analyzer or measurement channel.","breadcrumb":{"@id":"https:\/\/pxisource.com\/product\/pxi-2557\/#breadcrumb"},"inLanguage":"ru-RU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/pxisource.com\/product\/pxi-2557\/"]}]},{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/pxisource.com\/product\/pxi-2557\/#primaryimage","url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/08\/PXI-2557.webp","contentUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/08\/PXI-2557.webp","width":800,"height":800,"caption":"PXI-2557"},{"@type":"BreadcrumbList","@id":"https:\/\/pxisource.com\/product\/pxi-2557\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/pxisource.com\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/pxisource.com\/shop\/"},{"@type":"ListItem","position":3,"name":"PXI-2557"}]},{"@type":"WebSite","@id":"https:\/\/pxisource.com\/#website","url":"https:\/\/pxisource.com\/","name":"\u0421\u0438\u0441\u0442\u0435\u043c\u044b PXI","description":"NI PXI, PXIe Modular Test Instrument Supplier","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/pxisource.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ru-RU"}]},"product_brand":"National Instruments","product_price_currency":"USD","og_availability":"instock","product_availability":"instock","product_condition":"new"},"_links":{"self":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/34892","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":3,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/34892\/revisions"}],"predecessor-version":[{"id":35895,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/34892\/revisions\/35895"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media\/34815"}],"wp:attachment":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media?parent=34892"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_brand?post=34892"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_cat?post=34892"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_tag?post=34892"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}