{"id":34689,"date":"2026-08-07T14:47:43","date_gmt":"2026-08-07T06:47:43","guid":{"rendered":"https:\/\/pxisource.com\/?post_type=product&#038;p=34689"},"modified":"2026-08-27T13:24:06","modified_gmt":"2026-08-27T05:24:06","slug":"ni-6584","status":"publish","type":"product","link":"https:\/\/pxisource.com\/ru\/product\/ni-6584\/","title":{"rendered":"NI-6584"},"content":{"rendered":"<h3>Product Introduction<\/h3>\n<p>\n\u0417\u0435\u043c\u043b\u044f <strong>NI-6584<\/strong> is a high-performance FlexRIO digital I\/O adapter module designed for real-time interfacing with <strong>RS-422 and RS-485<\/strong> devices. It provides a total of <strong>32 digital I\/O channels<\/strong> organized as 16 receive and transmit pairs for serial communication, protocol interfacing, and custom FPGA-based digital test applications.\n<\/p>\n<p>\nWhen combined with a compatible NI FlexRIO FPGA module or FlexRIO controller, the NI-6584 creates a programmable digital instrument capable of acquiring, generating, and processing RS-422\/RS-485 signals in real time.\n<\/p>\n<p>\nThe module supports digital waveform sampling at clock rates up to <strong>16 MHz<\/strong> and is available in full-duplex and half-duplex configurations as well as terminated and unterminated versions. These capabilities make the NI-6584 suitable for serial communication testing, aerospace and defense electronics, industrial communications, protocol validation, hardware-in-the-loop systems, and custom digital instrumentation.\n<\/p>\n<h3>Product Overview<\/h3>\n<p>\n\u0417\u0435\u043c\u043b\u044f <strong>National Instruments NI-6584<\/strong> is part of the NI FlexRIO adapter module family. Unlike a conventional serial communication interface, the NI-6584 combines RS-422\/RS-485 electrical interfacing with a user-programmable FPGA architecture provided by a compatible FlexRIO FPGA module.\n<\/p>\n<p>\nA typical system architecture is:\n<\/p>\n<p>\n<strong>RS-422 \/ RS-485 Device \u2194 NI-6584 \u2194 FlexRIO FPGA Module \u2194 PXI\/PXIe System \u2194 Test Software<\/strong>\n<\/p>\n<p>\nThis architecture allows engineers to implement application-specific communication protocols, custom triggering, real-time data processing, hardware-timed responses, and specialized digital test functions.\n<\/p>\n<h3>Key Features<\/h3>\n<h4>32-Channel Digital I\/O<\/h4>\n<p>\nThe NI-6584 provides a total of <strong>32 digital I\/O channels<\/strong> for high-performance serial communication and digital interfacing applications.\n<\/p>\n<p>\nThe architecture supports 16 RX and TX signal pairs for interfacing with RS-422 and RS-485 equipment.\n<\/p>\n<h4>16 Bidirectional Digital Channels<\/h4>\n<p>\nThe NI-6584 provides <strong>16 bidirectional digital channels<\/strong> capable of transmitting and receiving digital signals.\n<\/p>\n<p>\nThese channels can be configured according to the selected NI-6584 hardware variant and required duplex architecture.\n<\/p>\n<h4>RS-422 Interface Support<\/h4>\n<p>\nThe NI-6584 is specifically designed for interfacing with <strong>RS-422<\/strong> devices.\n<\/p>\n<p>\nRS-422 differential signaling is commonly used in applications requiring reliable communication over longer cable distances and in electrically noisy environments.\n<\/p>\n<p>\nTypical RS-422 applications include:\n<\/p>\n<ul>\n<li>Industrial communication systems<\/li>\n<li>Aerospace electronics<\/li>\n<li>Defense systems<\/li>\n<li>Motion-control equipment<\/li>\n<li>Embedded systems<\/li>\n<li>\u041d\u0430\u0443\u0447\u043d\u043e\u0435 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435<\/li>\n<li>Custom serial interfaces<\/li>\n<\/ul>\n<h4>RS-485 Interface Support<\/h4>\n<p>\nThe NI-6584 also supports <strong>RS-485<\/strong> electrical interfaces, making it suitable for industrial serial communication and custom protocol applications.\n<\/p>\n<p>\nRS-485 is widely used in:\n<\/p>\n<ul>\n<li>\u041f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u0430\u044f \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0437\u0430\u0446\u0438\u044f<\/li>\n<li>Factory equipment<\/li>\n<li>\u0420\u0430\u0441\u043f\u0440\u0435\u0434\u0435\u043b\u0435\u043d\u043d\u044b\u0435 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f<\/li>\n<li>Instrumentation<\/li>\n<li>Motor controllers<\/li>\n<li>Embedded electronics<\/li>\n<li>Multi-device communication networks<\/li>\n<\/ul>\n<h4>Up to 16 MHz Clock Rate<\/h4>\n<p>\nThe NI-6584 can sample digital waveforms at clock rates up to <strong>16 MHz<\/strong>.\n<\/p>\n<p>\nThis capability allows the module to support high-performance digital acquisition and generation for compatible RS-422, RS-485, and electrically compatible interfaces.\n<\/p>\n<h4>Up to 16 Mbit\/s Digital Interface<\/h4>\n<p>\nThe NI-6584 is classified as a <strong>16 Mbit\/s digital I\/O adapter module<\/strong>.\n<\/p>\n<p>\nIts combination of high-speed differential digital I\/O and programmable FPGA processing makes it useful for applications requiring more customization than conventional serial interface hardware.\n<\/p>\n<h4>Full-Duplex Configuration<\/h4>\n<p>\nSelected NI-6584 variants support <strong>full-duplex communication<\/strong>, allowing separate transmit and receive signal paths to operate simultaneously.\n<\/p>\n<p>\nFull-duplex operation is particularly useful when the device under test requires independent RX and TX differential pairs.\n<\/p>\n<h4>Half-Duplex Configuration<\/h4>\n<p>\nThe NI-6584 is also available in a <strong>half-duplex configuration<\/strong>.\n<\/p>\n<p>\nIn this architecture, transmission and reception can share the same signal connections, making the module suitable for compatible two-wire RS-485 applications.\n<\/p>\n<h4>Terminated and Unterminated Versions<\/h4>\n<p>\nDifferent NI-6584 ordering configurations provide terminated and unterminated digital interfaces.\n<\/p>\n<p>\nThe appropriate version should be selected according to the electrical architecture, cable topology, communication standard, and termination requirements of the system.\n<\/p>\n<h4>FPGA-Based Digital Processing<\/h4>\n<p>\nThe NI-6584 operates with compatible FlexRIO FPGA hardware, enabling engineers to implement custom digital communication and processing logic directly in hardware.\n<\/p>\n<p>\nPossible FPGA functions include:\n<\/p>\n<ul>\n<li>Custom serial protocol implementation<\/li>\n<li>Real-time frame processing<\/li>\n<li>Digital pattern generation<\/li>\n<li>Digital waveform acquisition<\/li>\n<li>Protocol decoding<\/li>\n<li>Custom triggering<\/li>\n<li>Error detection<\/li>\n<li>Hardware-timed responses<\/li>\n<li>Real-time data filtering<\/li>\n<\/ul>\n<h3>Technical Specifications<\/h3>\n<table>\n<tr>\n<th>\u041f\u0430\u0440\u0430\u043c\u0435\u0442\u0440<\/th>\n<th>\u0421\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f<\/th>\n<\/tr>\n<tr>\n<td width=\"270\">Product Type<\/td>\n<td>FlexRIO Digital I\/O Adapter Module<\/td>\n<\/tr>\n<tr>\n<td>\u041c\u043e\u0434\u0435\u043b\u044c<\/td>\n<td>NI-6584<\/td>\n<\/tr>\n<tr>\n<td>Manufacturer<\/td>\n<td>\u041d\u0430\u0446\u0438\u043e\u043d\u0430\u043b\u044c\u043d\u044b\u0435 \u0438\u043d\u0441\u0442\u0440\u0443\u043c\u0435\u043d\u0442\u044b<\/td>\n<\/tr>\n<tr>\n<td>Part Numbers<\/td>\n<td>781290-01 \/ 781290-02 \/ 781290-03<\/td>\n<\/tr>\n<tr>\n<td>Digital I\/O Channels<\/td>\n<td>32<\/td>\n<\/tr>\n<tr>\n<td>Bidirectional Digital Channels<\/td>\n<td>16<\/td>\n<\/tr>\n<tr>\n<td>Interface Standards<\/td>\n<td>RS-422 \/ RS-485<\/td>\n<\/tr>\n<tr>\n<td>RX\/TX Architecture<\/td>\n<td>16 RX and TX Pairs<\/td>\n<\/tr>\n<tr>\n<td>Maximum Clock Rate<\/td>\n<td>16 MHz<\/td>\n<\/tr>\n<tr>\n<td>Maximum Digital Interface Rate<\/td>\n<td>16 Mbit\/s<\/td>\n<\/tr>\n<tr>\n<td>Duplex Options<\/td>\n<td>Full Duplex \/ Half Duplex, Depending on Variant<\/td>\n<\/tr>\n<tr>\n<td>Termination Options<\/td>\n<td>Terminated \/ Unterminated, Depending on Variant<\/td>\n<\/tr>\n<tr>\n<td>Logic \/ Interface Family<\/td>\n<td>RS-422 \/ RS-485<\/td>\n<\/tr>\n<tr>\n<td>Compatible FPGA Families<\/td>\n<td>Virtex-5 \/ Kintex-7<\/td>\n<\/tr>\n<tr>\n<td>Primary Connector<\/td>\n<td>68-Pin VHDCI<\/td>\n<\/tr>\n<tr>\n<td>Platform<\/td>\n<td>NI FlexRIO<\/td>\n<\/tr>\n<tr>\n<td>Primary Application<\/td>\n<td>RS-422\/RS-485 Real-Time Digital Interfacing and Analysis<\/td>\n<\/tr>\n<\/table>\n<h3>NI-6584 Part Number Differences<\/h3>\n<p>\nThe NI-6584 is available under several ordering part numbers. The primary differences involve duplex configuration and digital I\/O termination.\n<\/p>\n<table>\n<tr>\n<th>Part Number<\/th>\n<th>Duplex Configuration<\/th>\n<th>Termination<\/th>\n<\/tr>\n<tr>\n<td><strong>781290-01<\/strong><\/td>\n<td>Half Duplex<\/td>\n<td>100 \u03a9<\/td>\n<\/tr>\n<tr>\n<td><strong>781290-02<\/strong><\/td>\n<td>Full Duplex<\/td>\n<td>100 \u03a9<\/td>\n<\/tr>\n<tr>\n<td><strong>781290-03<\/strong><\/td>\n<td>Full Duplex<\/td>\n<td>Open \/ Unterminated<\/td>\n<\/tr>\n<\/table>\n<p>\nWhen purchasing an NI-6584, always verify the exact part number because the duplex and termination configuration affects compatibility with the target RS-422 or RS-485 system.\n<\/p>\n<h3>How Does the NI-6584 Work?<\/h3>\n<p>\nThe NI-6584 provides the electrical interface between external RS-422\/RS-485 devices and the programmable FPGA resources of a compatible FlexRIO system.\n<\/p>\n<p>\nA simplified signal path is:\n<\/p>\n<p>\n<strong>RS-422 \/ RS-485 Device \u2194 NI-6584 \u2194 FlexRIO FPGA \u2194 Host Application<\/strong>\n<\/p>\n<p>\nIncoming differential digital signals can be acquired by the NI-6584 and processed directly by FPGA logic. Likewise, the FPGA can generate digital data that the NI-6584 transmits to the connected device.\n<\/p>\n<h3>RS-422 Communication<\/h3>\n<p>\nRS-422 uses differential signaling and is widely used where robust serial communication is required.\n<\/p>\n<p>\nThe NI-6584 can interface directly with compatible RS-422 devices while the FlexRIO FPGA handles application-specific communication logic.\n<\/p>\n<p>\nThis architecture is useful for systems where engineers need more control over timing, framing, triggering, or protocol behavior than a standard serial interface provides.\n<\/p>\n<h3>RS-485 Communication<\/h3>\n<p>\nRS-485 is another differential signaling standard commonly used in industrial and embedded communication systems.\n<\/p>\n<p>\nThe NI-6584 can be used to acquire and generate compatible RS-485 signals for applications such as:\n<\/p>\n<ul>\n<li>Device communication testing<\/li>\n<li>Industrial protocol development<\/li>\n<li>Network simulation<\/li>\n<li>Embedded controller validation<\/li>\n<li>Communication interface testing<\/li>\n<li>Custom protocol implementation<\/li>\n<\/ul>\n<h3>Full Duplex vs Half Duplex<\/h3>\n<table>\n<tr>\n<th>\u0424\u0443\u043d\u043a\u0446\u0438\u044f<\/th>\n<th>Full Duplex<\/th>\n<th>Half Duplex<\/th>\n<\/tr>\n<tr>\n<td>Transmit and Receive<\/td>\n<td><strong>\u0421\u0438\u043d\u0445\u0440\u043e\u043d\u043d\u044b\u0439<\/strong><\/td>\n<td>Shared Communication Path<\/td>\n<\/tr>\n<tr>\n<td>Signal Architecture<\/td>\n<td>Separate RX \/ TX<\/td>\n<td><strong>Shared RX \/ TX<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Typical Application<\/td>\n<td>RS-422 \/ Four-Wire RS-485<\/td>\n<td>Two-Wire RS-485<\/td>\n<\/tr>\n<tr>\n<td>NI-6584 Availability<\/td>\n<td>\u0414\u0430<\/td>\n<td>\u0414\u0430<\/td>\n<\/tr>\n<\/table>\n<h3>Why Termination Matters<\/h3>\n<p>\nHigh-speed differential communication lines can experience signal reflections if the transmission line is not correctly terminated.\n<\/p>\n<p>\nSelected NI-6584 versions incorporate <strong>100 \u03a9 termination<\/strong>, while another version provides an open or unterminated interface.\n<\/p>\n<p>\nThe correct configuration depends on:\n<\/p>\n<ul>\n<li>Cable impedance<\/li>\n<li>Network topology<\/li>\n<li>Signal rate<\/li>\n<li>Cable length<\/li>\n<li>RS-422\/RS-485 configuration<\/li>\n<li>Location of existing termination resistors<\/li>\n<\/ul>\n<h3>Real-Time Protocol Interfacing<\/h3>\n<p>\nOne of the primary advantages of the NI-6584 is the ability to perform protocol interfacing directly in FPGA hardware.\n<\/p>\n<p>\nEngineers can develop application-specific logic for:\n<\/p>\n<ul>\n<li>Custom frame formats<\/li>\n<li>Proprietary serial protocols<\/li>\n<li>Hardware-timed message generation<\/li>\n<li>Real-time response generation<\/li>\n<li>Frame detection<\/li>\n<li>Packet processing<\/li>\n<li>Error injection<\/li>\n<li>Protocol validation<\/li>\n<\/ul>\n<h3>Custom Serial Protocol Testing<\/h3>\n<p>\nMany aerospace, defense, industrial, and embedded systems use proprietary protocols based on RS-422 or RS-485 electrical signaling.\n<\/p>\n<p>\nThe NI-6584 is particularly useful for these applications because the electrical interface and FPGA processing can be combined to create a custom protocol instrument.\n<\/p>\n<p>\nA typical test architecture is:\n<\/p>\n<p>\n<strong>Device Under Test \u2194 RS-422\/RS-485 \u2194 NI-6584 \u2194 FPGA Protocol Engine \u2194 Automated Test Software<\/strong>\n<\/p>\n<h3>Protocol Analysis<\/h3>\n<p>\nThe NI-6584 can acquire differential digital signals and transfer them to FPGA logic for real-time analysis.\n<\/p>\n<p>\nDepending on the FPGA application, engineers can analyze:\n<\/p>\n<ul>\n<li>Data frames<\/li>\n<li>Timing<\/li>\n<li>Bit patterns<\/li>\n<li>Communication errors<\/li>\n<li>Protocol states<\/li>\n<li>Device responses<\/li>\n<li>Custom message structures<\/li>\n<\/ul>\n<h3>Digital Pattern Generation<\/h3>\n<p>\nThe NI-6584 can also be used to generate digital patterns through compatible FlexRIO FPGA hardware.\n<\/p>\n<p>\nThis enables engineers to simulate communication devices, generate test sequences, stimulate devices under test, and reproduce specific communication conditions.\n<\/p>\n<h3>Error Injection<\/h3>\n<p>\nCustom FPGA logic can be developed to intentionally generate abnormal communication conditions for validation testing.\n<\/p>\n<p>\nDepending on the application, test systems can simulate:\n<\/p>\n<ul>\n<li>Incorrect data<\/li>\n<li>Timing errors<\/li>\n<li>Missing messages<\/li>\n<li>Modified frames<\/li>\n<li>Unexpected communication sequences<\/li>\n<\/ul>\n<p>\nThis capability is useful for validating how embedded systems respond to communication faults.\n<\/p>\n<h3>Hardware-in-the-Loop Testing<\/h3>\n<p>\nThe NI-6584 can be integrated into hardware-in-the-loop systems where an embedded controller or communication device must interact with simulated external equipment in real time.\n<\/p>\n<p>\nA typical HIL architecture is:\n<\/p>\n<p>\n<strong>Real-Time Test System \u2192 FlexRIO FPGA \u2192 NI-6584 \u2194 Device Under Test<\/strong>\n<\/p>\n<p>\nFPGA-based processing provides deterministic timing that is valuable for real-time simulation and protocol emulation.\n<\/p>\n<h3>Aerospace and Defense Applications<\/h3>\n<p>\nRS-422 interfaces are widely used in aerospace, avionics, defense, and other embedded electronic systems.\n<\/p>\n<p>\nThe NI-6584 can be incorporated into custom automated test systems for:\n<\/p>\n<ul>\n<li>Avionics interface testing<\/li>\n<li>Embedded electronics validation<\/li>\n<li>Communication bus simulation<\/li>\n<li>Subsystem integration testing<\/li>\n<li>Protocol verification<\/li>\n<li>Production testing<\/li>\n<\/ul>\n<h3>Industrial Communication Testing<\/h3>\n<p>\nRS-485 is widely used in industrial equipment because differential signaling provides robust communication in electrically noisy environments.\n<\/p>\n<p>\nThe NI-6584 can be used for development and validation of industrial communication interfaces, controllers, instrumentation, and embedded devices.\n<\/p>\n<h3>FPGA-Based Processing<\/h3>\n<p>\nA conventional RS-422 or RS-485 interface normally relies heavily on software running on a CPU.\n<\/p>\n<p>\nWith the NI-6584 and FlexRIO architecture, critical communication functions can be implemented directly in FPGA hardware.\n<\/p>\n<p>\nPotential advantages include:\n<\/p>\n<ul>\n<li>\u0414\u0435\u0442\u0435\u0440\u043c\u0438\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u043e\u0435 \u0432\u0440\u0435\u043c\u044f<\/li>\n<li>Low-latency processing<\/li>\n<li>Parallel protocol processing<\/li>\n<li>Custom digital logic<\/li>\n<li>Hardware-timed responses<\/li>\n<li>Real-time data filtering<\/li>\n<li>High-speed event detection<\/li>\n<\/ul>\n<h3>Compatible FlexRIO FPGA Modules<\/h3>\n<p>\nThe NI-6584 requires a compatible FlexRIO FPGA module or supported FlexRIO controller to create a complete programmable digital instrument.\n<\/p>\n<p>\nCompatible FlexRIO FPGA modules include selected models such as:\n<\/p>\n<ul>\n<li>PXIe-7971R<\/li>\n<li>PXIe-7972R<\/li>\n<li>PXIe-7975R<\/li>\n<li>PXIe-7976R<\/li>\n<\/ul>\n<p>\nCompatibility should always be verified for the exact NI-6584 part number, FlexRIO FPGA module, software version, and system configuration before purchasing.\n<\/p>\n<h3>NI-6584 with PXIe-7976R<\/h3>\n<p>\n\u0417\u0435\u043c\u043b\u044f <strong>PXIe-7976R<\/strong> is a Kintex-7-based FlexRIO FPGA module that can be paired with the NI-6584 for demanding custom digital communication applications.\n<\/p>\n<p>\nThis combination provides:\n<\/p>\n<ul>\n<li>RS-422\/RS-485 electrical interfacing<\/li>\n<li>Programmable FPGA processing<\/li>\n<li>Custom protocol implementation<\/li>\n<li>Real-time data analysis<\/li>\n<li>High-throughput PXI Express communication<\/li>\n<\/ul>\n<h3>VHDCI Connectivity<\/h3>\n<p>\nThe NI-6584 uses a <strong>68-\u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043d\u044b\u0439 \u0440\u0430\u0437\u044a\u0435\u043c VHDCI<\/strong> for connecting the digital I\/O signals to external equipment.\n<\/p>\n<p>\nNI configurations can use a VHDCI-to-multiple-DB9 cable assembly to provide convenient connections to RS-422\/RS-485 devices.\n<\/p>\n<p>\nAlways verify the pinout and cable configuration for the specific full-duplex or half-duplex NI-6584 variant before wiring the device under test.\n<\/p>\n<h3>NI-6584 vs Standard RS-485 Interface<\/h3>\n<table>\n<tr>\n<th>\u0424\u0443\u043d\u043a\u0446\u0438\u044f<\/th>\n<th>NI-6584 FlexRIO<\/th>\n<th>Standard RS-485 Interface<\/th>\n<\/tr>\n<tr>\n<td>RS-485 Electrical Interface<\/td>\n<td>\u0414\u0430<\/td>\n<td>\u0414\u0430<\/td>\n<\/tr>\n<tr>\n<td>RS-422 Support<\/td>\n<td><strong>\u0414\u0430<\/strong><\/td>\n<td>Device Dependent<\/td>\n<\/tr>\n<tr>\n<td>Programmable FPGA<\/td>\n<td><strong>Available Through FlexRIO<\/strong><\/td>\n<td>Usually No<\/td>\n<\/tr>\n<tr>\n<td>Custom Protocol Logic<\/td>\n<td><strong>Highly Flexible<\/strong><\/td>\n<td>\u041e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u043d\u044b\u0439<\/td>\n<\/tr>\n<tr>\n<td>Deterministic Processing<\/td>\n<td><strong>FPGA Based<\/strong><\/td>\n<td>Architecture Dependent<\/td>\n<\/tr>\n<tr>\n<td>Error Injection<\/td>\n<td><strong>Customizable<\/strong><\/td>\n<td>Usually Limited<\/td>\n<\/tr>\n<tr>\n<td>Primary Application<\/td>\n<td>Advanced Test and Protocol Validation<\/td>\n<td>General Serial Communication<\/td>\n<\/tr>\n<\/table>\n<h3>NI-6584 System Architecture<\/h3>\n<p>\nA complete NI-6584 FlexRIO system typically consists of:\n<\/p>\n<p>\n<strong>Device Under Test<\/strong><br \/>\n\u2193<br \/>\n<strong>RS-422 \/ RS-485 Connection<\/strong><br \/>\n\u2193<br \/>\n<strong>NI-6584 Digital I\/O Adapter Module<\/strong><br \/>\n\u2193<br \/>\n<strong>Compatible FlexRIO FPGA Module<\/strong><br \/>\n\u2193<br \/>\n<strong>\u0428\u0430\u0441\u0441\u0438 PXI Express<\/strong><br \/>\n\u2193<br \/>\n<strong>PXI Controller \/ Host Computer<\/strong><br \/>\n\u2193<br \/>\n<strong>LabVIEW FPGA \/ Test Application<\/strong>\n<\/p>\n<h3>Software and Programming<\/h3>\n<p>\nThe NI-6584 is designed for programmable FlexRIO applications where engineers define digital communication behavior according to the requirements of the device under test.\n<\/p>\n<p>\nTypical development tools can include:\n<\/p>\n<ul>\n<li>\u041b\u0430\u0431\u0412\u044c\u044e<\/li>\n<li>LabVIEW FPGA Module<\/li>\n<li>FlexRIO support software<\/li>\n<li>Custom host applications<\/li>\n<li>Automated test software<\/li>\n<\/ul>\n<p>\nThe LabVIEW FPGA environment can be used to implement custom hardware logic for protocol communication, triggering, signal generation, acquisition, and real-time processing.\n<\/p>\n<h3>How to Choose an NI-6584 Configuration<\/h3>\n<p>\nBefore purchasing the NI-6584, evaluate:\n<\/p>\n<ul>\n<li>RS-422 or RS-485 interface requirements<\/li>\n<li>Full-duplex or half-duplex operation<\/li>\n<li>Terminated or unterminated interface requirements<\/li>\n<li>Required number of communication channels<\/li>\n<li>Maximum clock rate<\/li>\n<li>Communication protocol<\/li>\n<li>Custom FPGA processing requirements<\/li>\n<li>Compatible FlexRIO FPGA module<\/li>\n<li>VHDCI cable requirements<\/li>\n<li>PXI\/PXIe chassis compatibility<\/li>\n<li>LabVIEW FPGA compatibility<\/li>\n<li>Required real-time processing performance<\/li>\n<\/ul>\n<h3>Industries<\/h3>\n<ul>\n<li>\u0410\u044d\u0440\u043e\u043a\u043e\u0441\u043c\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u0438 \u043e\u0431\u043e\u0440\u043e\u043d\u043d\u0430\u044f \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0441\u0442\u044c<\/li>\n<li>Avionics<\/li>\n<li>\u041f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u0430\u044f \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0437\u0430\u0446\u0438\u044f<\/li>\n<li>Embedded Systems<\/li>\n<li>Transportation<\/li>\n<li>Electronic Validation<\/li>\n<li>Scientific Instrumentation<\/li>\n<li>Automated Test<\/li>\n<li>Research and Development<\/li>\n<\/ul>\n<h3>Applications<\/h3>\n<h4>RS-422 Interface Testing<\/h4>\n<p>\nThe NI-6584 can acquire and generate RS-422 differential digital signals for embedded interface development and validation.\n<\/p>\n<h4>RS-485 Interface Testing<\/h4>\n<p>\nThe module can interface with compatible RS-485 devices for industrial communication testing, protocol development, and device validation.\n<\/p>\n<h4>Custom Protocol Testing<\/h4>\n<p>\nFlexRIO FPGA processing enables custom serial protocols to be implemented directly in programmable hardware.\n<\/p>\n<h4>Protocol Analysis<\/h4>\n<p>\nIncoming digital signals can be processed by FPGA logic for real-time frame detection, timing analysis, error detection, and protocol validation.\n<\/p>\n<h4>Hardware-in-the-Loop Testing<\/h4>\n<p>\nDeterministic FPGA processing makes the NI-6584 suitable for HIL applications requiring real-time communication with a device under test.\n<\/p>\n<h4>Avionics Testing<\/h4>\n<p>\nThe NI-6584 can be incorporated into specialized avionics and aerospace test systems that use compatible RS-422 electrical interfaces.\n<\/p>\n<h4>Automated Production Testing<\/h4>\n<p>\nThe module can be used in automated systems for validating RS-422\/RS-485 communication interfaces during electronic equipment production.\n<\/p>\n<h3>Recommended Related Products<\/h3>\n<table>\n<tr>\n<td width=\"210\">\n<strong>NI-6584<\/strong>\n<\/td>\n<td>\n16 Mbit\/s, 32-channel FlexRIO digital I\/O adapter module for RS-422 and RS-485 interfacing.\n<\/td>\n<\/tr>\n<tr>\n<td>\n<strong>PXIe-7971R<\/strong>\n<\/td>\n<td>\nKintex-7 K325T FlexRIO FPGA module compatible with NI-6584 for programmable digital test applications.\n<\/td>\n<\/tr>\n<tr>\n<td>\n<strong>PXIe-7972R<\/strong>\n<\/td>\n<td>\nKintex-7 K325T FlexRIO FPGA module with onboard memory for advanced data acquisition and processing.\n<\/td>\n<\/tr>\n<tr>\n<td>\n<strong>PXIe-7975R<\/strong>\n<\/td>\n<td>\nKintex-7 K410T FlexRIO FPGA module for high-performance custom instrumentation and signal processing.\n<\/td>\n<\/tr>\n<tr>\n<td>\n<strong>PXIe-7976R<\/strong>\n<\/td>\n<td>\nKintex-7 K410T FlexRIO FPGA module with 2 GB RAM and high-throughput PXI Express data transfer.\n<\/td>\n<\/tr>\n<tr>\n<td>\n<strong>\u0428\u0430\u0441\u0441\u0438 PXI Express<\/strong>\n<\/td>\n<td>\nModular instrumentation chassis for integrating FlexRIO FPGA modules with other PXIe measurement and test hardware.\n<\/td>\n<\/tr>\n<\/table>\n<h3>Why Choose NI-6584?<\/h3>\n<ul>\n<li>32-channel digital I\/O architecture<\/li>\n<li>16 bidirectional digital channels<\/li>\n<li>16 RX and TX differential pairs<\/li>\n<li>RS-422 interface support<\/li>\n<li>RS-485 interface support<\/li>\n<li>Up to 16 MHz clock rate<\/li>\n<li>Up to 16 Mbit\/s digital interfacing<\/li>\n<li>Full-duplex configurations available<\/li>\n<li>Half-duplex configuration available<\/li>\n<li>Terminated and unterminated options<\/li>\n<li>FlexRIO FPGA integration<\/li>\n<li>Custom protocol implementation<\/li>\n<li>Deterministic real-time processing<\/li>\n<li>Custom triggering capability<\/li>\n<li>Suitable for HIL testing<\/li>\n<li>Suitable for aerospace and defense testing<\/li>\n<li>Suitable for industrial communication validation<\/li>\n<\/ul>\n<h3>Frequently Asked Questions<\/h3>\n<h4>What is the NI-6584?<\/h4>\n<p>\nThe NI-6584 is a 16 Mbit\/s, 32-channel FlexRIO digital I\/O adapter module designed primarily for real-time interfacing and analysis of RS-422 and RS-485 signals.\n<\/p>\n<h4>What are the NI-6584 part numbers?<\/h4>\n<p>\nNI currently lists <strong>781290-01, 781290-02, and 781290-03<\/strong> as NI-6584 ordering part numbers. The variants provide different duplex and termination configurations.\n<\/p>\n<h4>How many channels does the NI-6584 have?<\/h4>\n<p>\nThe NI-6584 is classified as a <strong>32-channel digital I\/O adapter module<\/strong> and provides 16 bidirectional digital channels for RS-422\/RS-485 interfacing.\n<\/p>\n<h4>What communication standards does the NI-6584 support?<\/h4>\n<p>\nThe NI-6584 is designed primarily for <strong>RS-422 and RS-485<\/strong> electrical interfaces and can also be used with other electrically compatible interfaces where the signal requirements are satisfied.\n<\/p>\n<h4>What is the maximum clock rate of the NI-6584?<\/h4>\n<p>\nThe NI-6584 supports digital waveform sampling at clock rates up to <strong>16 MHz<\/strong>.\n<\/p>\n<h4>Does the NI-6584 support full-duplex communication?<\/h4>\n<p>\nYes. The 781290-02 and 781290-03 configurations support full-duplex operation.\n<\/p>\n<h4>Does the NI-6584 support half-duplex communication?<\/h4>\n<p>\nYes. The 781290-01 configuration provides half-duplex operation.\n<\/p>\n<h4>What is the difference between NI-6584 part numbers?<\/h4>\n<p>\nThe main differences are the duplex configuration and input termination. The 781290-01 is a half-duplex 100 \u03a9 configuration, the 781290-02 is a full-duplex 100 \u03a9 configuration, and the 781290-03 provides a full-duplex unterminated configuration.\n<\/p>\n<h4>Does the NI-6584 have an FPGA?<\/h4>\n<p>\nThe NI-6584 is the digital I\/O adapter portion of the FlexRIO system. Programmable FPGA resources are provided by the compatible FlexRIO FPGA module or supported FlexRIO controller used with it.\n<\/p>\n<h4>Which FPGA modules are compatible with the NI-6584?<\/h4>\n<p>\nNI currently lists compatible FlexRIO modules including the PXIe-7971R, PXIe-7972R, PXIe-7975R, and PXIe-7976R. Compatibility should be verified for the exact hardware and software configuration.\n<\/p>\n<h4>Can the NI-6584 be used for custom protocols?<\/h4>\n<p>\nYes. This is one of the major advantages of the FlexRIO architecture. Engineers can implement custom FPGA logic for proprietary protocols, specialized timing, triggering, data processing, and device simulation.\n<\/p>\n<h4>Can the NI-6584 be used for protocol analysis?<\/h4>\n<p>\nYes. RS-422\/RS-485 data can be acquired and processed by FPGA logic for real-time protocol monitoring and analysis.\n<\/p>\n<h4>Can the NI-6584 generate RS-422 or RS-485 signals?<\/h4>\n<p>\nYes. The NI-6584 supports digital generation as well as acquisition when configured with compatible FlexRIO FPGA hardware.\n<\/p>\n<h4>Can the NI-6584 be used for hardware-in-the-loop testing?<\/h4>\n<p>\nYes. Its FPGA-based architecture makes it suitable for deterministic HIL communication and embedded-controller validation applications.\n<\/p>\n<h4>Can the NI-6584 be used for avionics testing?<\/h4>\n<p>\nYes. The module can be incorporated into custom aerospace and avionics test systems that use compatible RS-422\/RS-485 electrical interfaces.\n<\/p>\n<h4>What connector does the NI-6584 use?<\/h4>\n<p>\nThe NI-6584 uses a <strong>68-\u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043d\u044b\u0439 \u0440\u0430\u0437\u044a\u0435\u043c VHDCI<\/strong> for its RS-422\/RS-485 digital I\/O connections. Compatible cable assemblies can break the signals out to DB9 connectors for connection to external devices.\n<\/p>\n<h4>What hardware is required to use the NI-6584?<\/h4>\n<p>\nA complete system typically requires the NI-6584 adapter module, a compatible FlexRIO FPGA module or supported FlexRIO controller, an appropriate PXI\/PXIe system, required cables, and compatible NI software.\n<\/p>\n<h4>What should I check before purchasing an NI-6584?<\/h4>\n<p>\nBefore purchasing the NI-6584, verify the exact part number, RS-422 or RS-485 interface, full-duplex or half-duplex requirement, termination configuration, channel requirements, communication speed, compatible FlexRIO FPGA module, cable configuration, PXI\/PXIe chassis, and software environment.\n<\/p>\n<h3>\u0417\u0430\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435<\/h3>\n<p>\n\u0417\u0435\u043c\u043b\u044f <strong>NI-6584 FlexRIO Digital I\/O Adapter Module<\/strong> provides 32-channel digital I\/O for real-time RS-422 and RS-485 communication, acquisition, generation, and protocol analysis. With support for up to 16 MHz clock rates, full-duplex and half-duplex configurations, terminated and unterminated variants, and programmable FlexRIO FPGA processing, the NI-6584 is well suited for custom serial communication, avionics testing, industrial interface validation, hardware-in-the-loop systems, embedded electronics, protocol analysis, and advanced automated test applications.<\/p>","protected":false},"excerpt":{"rendered":"<p>Number of Bidirectional Digital Channels: 16<br \/>\nMaximum Clock Rate: 16 MHz<br \/>\nLogic Levels And Range: RS-422\/RS-485<br \/>\n\u0421\u043e\u0432\u043c\u0435\u0441\u0442\u0438\u043c\u044b\u0439 FPGA: Kintex-7, Virtex-5<br \/>\nMaximum Data Rate: 16 Mbits\/s<br \/>\n\u0422\u0438\u043f \u0441\u0438\u0433\u043d\u0430\u043b\u0438\u0437\u0430\u0446\u0438\u0438: \u0414\u0438\u0444\u0444\u0435\u0440\u0435\u043d\u0446\u0438\u0430\u043b\u044c\u043d\u044b\u0439<\/p>","protected":false},"featured_media":31005,"template":"","meta":{"_acf_changed":false},"product_brand":[18],"product_cat":[673],"product_tag":[],"class_list":["post-34689","product","type-product","status-publish","has-post-thumbnail","product_brand-national-instruments","product_cat-c-module","first","instock","shipping-taxable","purchasable","product-type-simple"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.0 (Yoast SEO v28.1) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>NI-6584 Digital I\/O Adapter Module for FlexRIO 781290-02, In Stock | Project Pricing<\/title>\n<meta name=\"description\" content=\"NI-6584 is a 16 Mbit\/s, 32-channel FlexRIO digital I\/O adapter module for real-time RS-422\/RS-485 interfacing, protocol analysis and FPGA-based test systems.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/pxisource.com\/ru\/product\/ni-6584\/\" \/>\n<meta property=\"og:locale\" content=\"ru_RU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"NI-6584\" \/>\n<meta property=\"og:description\" content=\"NI-6584 is a 16 Mbit\/s, 32-channel FlexRIO digital I\/O adapter module for real-time RS-422\/RS-485 interfacing, protocol analysis and FPGA-based test systems.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/pxisource.com\/ru\/product\/ni-6584\/\" \/>\n<meta property=\"og:site_name\" content=\"PXI Source\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=61582573040385\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-27T05:24:06+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/NI-6584.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"800\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u0426\u0435\u043d\u0430\" \/>\n\t<meta name=\"twitter:data1\" content=\"&#036;2,667.00\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c\" \/>\n\t<meta name=\"twitter:data2\" content=\"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/ni-6584\\\/\",\"url\":\"https:\\\/\\\/pxisource.com\\\/product\\\/ni-6584\\\/\",\"name\":\"NI-6584 Digital I\\\/O Adapter Module for FlexRIO 781290-02, In Stock | Project Pricing\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/ni-6584\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/ni-6584\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/NI-6584.webp\",\"datePublished\":\"2026-08-07T06:47:43+00:00\",\"dateModified\":\"2026-08-27T05:24:06+00:00\",\"description\":\"NI-6584 is a 16 Mbit\\\/s, 32-channel FlexRIO digital I\\\/O adapter module for real-time RS-422\\\/RS-485 interfacing, protocol analysis and FPGA-based test systems.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/ni-6584\\\/#breadcrumb\"},\"inLanguage\":\"ru-RU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/pxisource.com\\\/product\\\/ni-6584\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/ni-6584\\\/#primaryimage\",\"url\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/NI-6584.webp\",\"contentUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/NI-6584.webp\",\"width\":800,\"height\":800,\"caption\":\"NI-6584\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/ni-6584\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/pxisource.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u5546\u5e97\",\"item\":\"https:\\\/\\\/pxisource.com\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"NI-6584\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\",\"url\":\"https:\\\/\\\/pxisource.com\\\/\",\"name\":\"PXI Systems\",\"description\":\"PXI, PXIe and Modular Test Equipment\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/pxisource.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ru-RU\"}]}<\/script>\n<meta property=\"product:brand\" content=\"National Instruments\" \/>\n<meta property=\"product:price:amount\" content=\"2667.00\" \/>\n<meta property=\"product:price:currency\" content=\"USD\" \/>\n<meta property=\"og:availability\" content=\"instock\" \/>\n<meta property=\"product:availability\" content=\"instock\" \/>\n<meta property=\"product:condition\" content=\"new\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"NI-6584 Digital I\/O Adapter Module for FlexRIO 781290-02, In Stock | Project Pricing","description":"NI-6584 is a 16 Mbit\/s, 32-channel FlexRIO digital I\/O adapter module for real-time RS-422\/RS-485 interfacing, protocol analysis and FPGA-based test systems.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/pxisource.com\/ru\/product\/ni-6584\/","og_locale":"ru_RU","og_type":"article","og_title":"NI-6584","og_description":"NI-6584 is a 16 Mbit\/s, 32-channel FlexRIO digital I\/O adapter module for real-time RS-422\/RS-485 interfacing, protocol analysis and FPGA-based test systems.","og_url":"https:\/\/pxisource.com\/ru\/product\/ni-6584\/","og_site_name":"PXI Source","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=61582573040385","article_modified_time":"2026-08-27T05:24:06+00:00","og_image":[{"width":800,"height":800,"url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/NI-6584.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"\u0426\u0435\u043d\u0430":"&#36;2,667.00","\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c":"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/pxisource.com\/product\/ni-6584\/","url":"https:\/\/pxisource.com\/product\/ni-6584\/","name":"NI-6584 Digital I\/O Adapter Module for FlexRIO 781290-02, In Stock | Project Pricing","isPartOf":{"@id":"https:\/\/pxisource.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/pxisource.com\/product\/ni-6584\/#primaryimage"},"image":{"@id":"https:\/\/pxisource.com\/product\/ni-6584\/#primaryimage"},"thumbnailUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/NI-6584.webp","datePublished":"2026-08-07T06:47:43+00:00","dateModified":"2026-08-27T05:24:06+00:00","description":"NI-6584 is a 16 Mbit\/s, 32-channel FlexRIO digital I\/O adapter module for real-time RS-422\/RS-485 interfacing, protocol analysis and FPGA-based test systems.","breadcrumb":{"@id":"https:\/\/pxisource.com\/product\/ni-6584\/#breadcrumb"},"inLanguage":"ru-RU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/pxisource.com\/product\/ni-6584\/"]}]},{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/pxisource.com\/product\/ni-6584\/#primaryimage","url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/NI-6584.webp","contentUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/NI-6584.webp","width":800,"height":800,"caption":"NI-6584"},{"@type":"BreadcrumbList","@id":"https:\/\/pxisource.com\/product\/ni-6584\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/pxisource.com\/"},{"@type":"ListItem","position":2,"name":"\u5546\u5e97","item":"https:\/\/pxisource.com\/shop\/"},{"@type":"ListItem","position":3,"name":"NI-6584"}]},{"@type":"WebSite","@id":"https:\/\/pxisource.com\/#website","url":"https:\/\/pxisource.com\/","name":"\u0421\u0438\u0441\u0442\u0435\u043c\u044b PXI","description":"PXI, PXIe and Modular Test Equipment","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/pxisource.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ru-RU"}]},"product_brand":"National Instruments","product_price_amount":"2667.00","product_price_currency":"USD","og_availability":"instock","product_availability":"instock","product_condition":"new"},"_links":{"self":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/34689","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":3,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/34689\/revisions"}],"predecessor-version":[{"id":35463,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/34689\/revisions\/35463"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media\/31005"}],"wp:attachment":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media?parent=34689"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_brand?post=34689"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_cat?post=34689"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_tag?post=34689"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}