{"id":34660,"date":"2026-08-07T13:27:35","date_gmt":"2026-08-07T05:27:35","guid":{"rendered":"https:\/\/pxisource.com\/?post_type=product&#038;p=34660"},"modified":"2026-08-27T18:48:13","modified_gmt":"2026-08-27T10:48:13","slug":"usb-6229","status":"publish","type":"product","link":"https:\/\/pxisource.com\/ru\/product\/usb-6229\/","title":{"rendered":"USB-6229"},"content":{"rendered":"<h3>Product Introduction<\/h3>\n<p>\n\u0417\u0435\u043c\u043b\u044f <strong>NI USB-6229<\/strong> is a high-channel-count <strong>M Series multifunction data acquisition (DAQ) device<\/strong> designed for laboratory measurement, automated test, data logging, control, research, and industrial measurement applications.\n<\/p>\n<p>\nThe USB-6229 combines <strong>32 \u0430\u043d\u0430\u043b\u043e\u0433\u043e\u0432\u044b\u0445 \u0432\u0445\u043e\u0434\u043d\u044b\u0445 \u043a\u0430\u043d\u0430\u043b\u0430<\/strong>, \u0434\u043e <strong>250 kS\/s analog input sampling<\/strong>, <strong>4 \u0430\u043d\u0430\u043b\u043e\u0433\u043e\u0432\u044b\u0445 \u0432\u044b\u0445\u043e\u0434\u043d\u044b\u0445 \u043a\u0430\u043d\u0430\u043b\u0430<\/strong>, <strong>48 digital I\/O lines<\/strong>, and hardware counter\/timer functionality in a single USB-connected measurement device.\n<\/p>\n<p>\nIts multifunction architecture allows engineers to acquire analog signals, generate analog outputs, monitor or control digital signals, perform frequency and event measurements, and synchronize measurement tasks from one DAQ platform.\n<\/p>\n<h3>Product Overview<\/h3>\n<p>\n\u0417\u0435\u043c\u043b\u044f <strong>National Instruments USB-6229<\/strong> belongs to the NI M Series family of multifunction DAQ devices.\n<\/p>\n<p>\nA typical measurement architecture is:\n<\/p>\n<p>\n<strong>Sensors \/ DUT \u2192 USB-6229 \u2192 USB \u2192 Host Computer \u2192 NI-DAQmx \/ LabVIEW<\/strong>\n<\/p>\n<p>\nBecause it uses USB connectivity, the USB-6229 is suitable for desktop and laboratory systems where installing an internal PCI or PCI Express DAQ card is inconvenient.\n<\/p>\n<h3>Key Features<\/h3>\n<h4>32 Analog Input Channels<\/h4>\n<p>\nThe USB-6229 provides up to <strong>32 single-ended or 16 differential analog input channels<\/strong>, allowing a relatively large number of voltage signals to be acquired with one DAQ device.\n<\/p>\n<p>\nTypical analog input applications include:\n<\/p>\n<ul>\n<li>Voltage measurement<\/li>\n<li>Sensor data acquisition<\/li>\n<li>Automated test<\/li>\n<li>Laboratory experiments<\/li>\n<li>Process monitoring<\/li>\n<li>Electronic validation<\/li>\n<li>Multi-channel data logging<\/li>\n<\/ul>\n<h4>250 kS\/s Analog Input Sampling<\/h4>\n<p>\nThe USB-6229 supports an aggregate analog input sampling rate of up to <strong>250 kS\/s<\/strong>.\n<\/p>\n<p>\nThe analog inputs use a multiplexed architecture, meaning the available sampling rate is shared across the active analog input channels rather than providing 250 kS\/s independently on every channel.\n<\/p>\n<p>\nThis distinction is important when selecting the USB-6229 for multi-channel acquisition applications.\n<\/p>\n<h4>16-Bit Analog Input Resolution<\/h4>\n<p>\nThe USB-6229 provides <strong>16-bit analog input resolution<\/strong> for general-purpose voltage measurements and sensor acquisition.\n<\/p>\n<p>\nThe combination of 16-bit resolution and programmable input ranges allows the device to accommodate a wide variety of measurement signals.\n<\/p>\n<h4>Programmable Analog Input Ranges<\/h4>\n<p>\nThe USB-6229 supports multiple programmable analog input ranges, allowing measurement sensitivity to be adapted to the expected signal amplitude.\n<\/p>\n<p>\nTypical bipolar ranges include:\n<\/p>\n<ul>\n<li>\u00b110 V<\/li>\n<li>\u00b15 V<\/li>\n<li>\u00b11 V<\/li>\n<li>\u00b10.2 V<\/li>\n<\/ul>\n<p>\nSelecting the smallest appropriate range can improve effective measurement resolution for lower-amplitude signals.\n<\/p>\n<h4>4 Analog Output Channels<\/h4>\n<p>\nThe USB-6229 provides <strong>4 \u0430\u043d\u0430\u043b\u043e\u0433\u043e\u0432\u044b\u0445 \u0432\u044b\u0445\u043e\u0434\u043d\u044b\u0445 \u043a\u0430\u043d\u0430\u043b\u0430<\/strong> for programmable voltage generation.\n<\/p>\n<p>\nAnalog outputs can be used for:\n<\/p>\n<ul>\n<li>Device stimulus<\/li>\n<li>Control voltage generation<\/li>\n<li>Waveform generation<\/li>\n<li>Sensor simulation<\/li>\n<li>Automated test<\/li>\n<li>Laboratory experiments<\/li>\n<\/ul>\n<h4>16-Bit Analog Output Resolution<\/h4>\n<p>\nThe analog output subsystem provides <strong>16-\u0431\u0438\u0442\u043d\u043e\u0435 \u0440\u0430\u0437\u0440\u0435\u0448\u0435\u043d\u0438\u0435<\/strong>, allowing programmable voltage signals to be generated for compatible test and control applications.\n<\/p>\n<h4>48 Digital I\/O Lines<\/h4>\n<p>\nThe USB-6229 provides <strong>48 digital I\/O lines<\/strong> for digital control, status monitoring, triggering, and mixed-signal test applications.\n<\/p>\n<p>\nDigital I\/O applications can include:\n<\/p>\n<ul>\n<li>Relay control<\/li>\n<li>Switch monitoring<\/li>\n<li>DUT control<\/li>\n<li>Digital status acquisition<\/li>\n<li>Test fixture control<\/li>\n<li>Trigger generation<\/li>\n<li>Digital logic interfacing<\/li>\n<\/ul>\n<h4>Counter\/Timer Functionality<\/h4>\n<p>\nThe USB-6229 includes hardware counter\/timer resources for timing and pulse-related measurements.\n<\/p>\n<p>\nCounter applications can include:\n<\/p>\n<ul>\n<li>\u041f\u043e\u0434\u0441\u0447\u0435\u0442 \u0441\u043e\u0431\u044b\u0442\u0438\u0439<\/li>\n<li>Frequency measurement<\/li>\n<li>Period measurement<\/li>\n<li>Pulse-width measurement<\/li>\n<li>Encoder measurement<\/li>\n<li>\u0413\u0435\u043d\u0435\u0440\u0430\u0446\u0438\u044f \u0438\u043c\u043f\u0443\u043b\u044c\u0441\u043e\u0432<\/li>\n<\/ul>\n<h4>USB Connectivity<\/h4>\n<p>\nThe USB-6229 connects to a host computer through USB, eliminating the need to install an internal measurement card.\n<\/p>\n<p>\nThis makes the device convenient for:\n<\/p>\n<ul>\n<li>Desktop measurement systems<\/li>\n<li>Laboratory benches<\/li>\n<li>Portable test systems<\/li>\n<li>University laboratories<\/li>\n<li>Research environments<\/li>\n<li>Temporary test setups<\/li>\n<\/ul>\n<h4>NI-DAQmx Support<\/h4>\n<p>\nThe USB-6229 is supported by the <strong>\u041d\u0418-DAQmx<\/strong> driver architecture for compatible operating systems and development environments.\n<\/p>\n<p>\nNI-DAQmx provides configuration and programming support for analog input, analog output, digital I\/O, counters, triggering, and timing.\n<\/p>\n<h3>Technical Specifications<\/h3>\n<table>\n<tr>\n<th>\u041f\u0430\u0440\u0430\u043c\u0435\u0442\u0440<\/th>\n<th>\u0421\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f<\/th>\n<\/tr>\n<tr>\n<td width=\"280\">Product Type<\/td>\n<td>M Series Multifunction DAQ Device<\/td>\n<\/tr>\n<tr>\n<td>\u041c\u043e\u0434\u0435\u043b\u044c<\/td>\n<td>USB-6229<\/td>\n<\/tr>\n<tr>\n<td>Manufacturer<\/td>\n<td>\u041d\u0430\u0446\u0438\u043e\u043d\u0430\u043b\u044c\u043d\u044b\u0435 \u0438\u043d\u0441\u0442\u0440\u0443\u043c\u0435\u043d\u0442\u044b<\/td>\n<\/tr>\n<tr>\n<td>\u0428\u0438\u043d\u043d\u044b\u0439 \u0438\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441<\/td>\n<td>USB<\/td>\n<\/tr>\n<tr>\n<td>Analog Input Channels<\/td>\n<td>32 Single-Ended \/ 16 Differential<\/td>\n<\/tr>\n<tr>\n<td>Analog Input Architecture<\/td>\n<td>Multiplexed<\/td>\n<\/tr>\n<tr>\n<td>Maximum AI Sample Rate<\/td>\n<td>250 kS\/s Aggregate<\/td>\n<\/tr>\n<tr>\n<td>Analog Input Resolution<\/td>\n<td>16 Bit<\/td>\n<\/tr>\n<tr>\n<td>Maximum Analog Input Range<\/td>\n<td>\u00b110 V<\/td>\n<\/tr>\n<tr>\n<td>Analog Output Channels<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<td>Analog Output Resolution<\/td>\n<td>16 Bit<\/td>\n<\/tr>\n<tr>\n<td>\u0426\u0438\u0444\u0440\u043e\u0432\u043e\u0439 \u0432\u0432\u043e\u0434-\u0432\u044b\u0432\u043e\u0434<\/td>\n<td>48 Lines<\/td>\n<\/tr>\n<tr>\n<td>Counter\/Timers<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>Counter Resolution<\/td>\n<td>32 Bit<\/td>\n<\/tr>\n<tr>\n<td>Driver<\/td>\n<td>\u041d\u0418-DAQmx<\/td>\n<\/tr>\n<tr>\n<td>Product Family<\/td>\n<td>NI M Series<\/td>\n<\/tr>\n<tr>\n<td>Primary Applications<\/td>\n<td>Data Acquisition, Automated Test, Data Logging, Laboratory Measurement and Control<\/td>\n<\/tr>\n<\/table>\n<h3>How Does the USB-6229 Work?<\/h3>\n<p>\nThe USB-6229 acquires analog and digital signals from sensors or devices under test and transfers measurement data to a host computer through USB.\n<\/p>\n<p>\nA simplified analog acquisition path is:\n<\/p>\n<p>\n<strong>Sensor \/ Signal \u2192 USB-6229 Analog Input \u2192 ADC \u2192 USB \u2192 Computer \u2192 Measurement Software<\/strong>\n<\/p>\n<p>\nFor automated test applications, the device can also generate analog and digital outputs:\n<\/p>\n<p>\n<strong>Computer \u2192 USB-6229 \u2192 Analog \/ Digital Output \u2192 DUT \u2192 USB-6229 Input \u2192 Measurement<\/strong>\n<\/p>\n<p>\nThis bidirectional measurement and control capability makes the USB-6229 suitable for multifunction test systems.\n<\/p>\n<h3>What Is an M Series Multifunction DAQ Device?<\/h3>\n<p>\nNI M Series devices combine several measurement and control functions within one DAQ platform.\n<\/p>\n<p>\nDepending on the model, these functions can include:\n<\/p>\n<ul>\n<li>Analog input<\/li>\n<li>Analog output<\/li>\n<li>Digital input<\/li>\n<li>Digital output<\/li>\n<li>Counter\/timers<\/li>\n<li>Hardware timing<\/li>\n<li>\u0417\u0430\u043f\u0443\u0441\u043a<\/li>\n<\/ul>\n<p>\nThe USB-6229 is particularly useful when a system requires a relatively large number of analog and digital channels without requiring extremely high sampling rates.\n<\/p>\n<h3>32 Single-Ended vs 16 Differential Inputs<\/h3>\n<p>\nThe USB-6229 can provide up to <strong>32 single-ended analog input channels<\/strong> \u0438\u043b\u0438 <strong>16 differential analog input channels<\/strong>.\n<\/p>\n<table>\n<tr>\n<th>\u041a\u043e\u043d\u0444\u0438\u0433\u0443\u0440\u0430\u0446\u0438\u044f<\/th>\n<th>Maximum Channels<\/th>\n<th>Typical Advantage<\/th>\n<\/tr>\n<tr>\n<td>Single-Ended<\/td>\n<td>32<\/td>\n<td>Higher Channel Count<\/td>\n<\/tr>\n<tr>\n<td>Differential<\/td>\n<td>16<\/td>\n<td>Better Noise Rejection<\/td>\n<\/tr>\n<\/table>\n<p>\nDifferential measurements are often preferred in electrically noisy environments or when signal sources do not share a clean common reference.\n<\/p>\n<h3>Multiplexed Analog Input Architecture<\/h3>\n<p>\nThe USB-6229 uses a <strong>multiplexed analog input architecture<\/strong>.\n<\/p>\n<p>\nMultiple analog input channels share the ADC and are sampled sequentially.\n<\/p>\n<p>\nA simplified architecture is:\n<\/p>\n<p>\n<strong>AI0 \/ AI1 \/ AI2 \/ AI3 \/ &#8230; \u2192 Multiplexer \u2192 ADC \u2192 Digital Data<\/strong>\n<\/p>\n<p>\nTherefore, the specified 250 kS\/s maximum sampling rate should not be interpreted as 250 kS\/s simultaneously on every analog input channel.\n<\/p>\n<h3>Multi-Channel Data Logging<\/h3>\n<p>\nThe relatively high analog input channel count makes the USB-6229 useful for multi-channel data logging applications.\n<\/p>\n<p>\nTypical signals can include:\n<\/p>\n<ul>\n<li>Voltage sensors<\/li>\n<li>Pressure sensor outputs<\/li>\n<li>Position signals<\/li>\n<li>Process signals<\/li>\n<li>Laboratory instrumentation outputs<\/li>\n<li>Conditioned temperature signals<\/li>\n<\/ul>\n<p>\nSensors requiring excitation, isolation, amplification, or specialized conditioning may require external signal-conditioning hardware.\n<\/p>\n<h3>Automated Test Applications<\/h3>\n<p>\nThe combination of analog input, analog output, digital I\/O, and counter\/timers makes the USB-6229 suitable for automated functional test systems.\n<\/p>\n<p>\nA typical sequence can:\n<\/p>\n<ol>\n<li>Configure digital control lines.<\/li>\n<li>Generate an analog stimulus.<\/li>\n<li>Activate the device under test.<\/li>\n<li>Acquire analog response signals.<\/li>\n<li>Measure digital states or pulse signals.<\/li>\n<li>Analyze the acquired data.<\/li>\n<li>Determine pass or fail status.<\/li>\n<\/ol>\n<h3>Analog Output Generation<\/h3>\n<p>\nThe four analog outputs can generate programmable voltage signals for test, simulation, and control applications.\n<\/p>\n<p>\nA typical stimulus-response test architecture is:\n<\/p>\n<p>\n<strong>USB-6229 AO \u2192 DUT \u2192 USB-6229 AI \u2192 Computer Analysis<\/strong>\n<\/p>\n<p>\nThis allows the same multifunction DAQ device to generate test signals and measure the resulting DUT response.\n<\/p>\n<h3>Digital I\/O Applications<\/h3>\n<p>\nThe 48 digital I\/O lines provide substantial flexibility for mixed-signal test systems.\n<\/p>\n<p>\nThey can be used for:\n<\/p>\n<ul>\n<li>Test fixture control<\/li>\n<li>Relay switching<\/li>\n<li>Device configuration<\/li>\n<li>Status monitoring<\/li>\n<li>Digital triggering<\/li>\n<li>Logic control<\/li>\n<li>Production test interfaces<\/li>\n<\/ul>\n<h3>Counter\/Timer Applications<\/h3>\n<p>\nThe two 32-bit counter\/timers can perform hardware-timed pulse and event measurements.\n<\/p>\n<p>\n\u0422\u0438\u043f\u0438\u0447\u043d\u044b\u0435 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f \u0432\u043a\u043b\u044e\u0447\u0430\u044e\u0442:\n<\/p>\n<ul>\n<li>Frequency measurement<\/li>\n<li>\u041f\u043e\u0434\u0441\u0447\u0435\u0442 \u0441\u043e\u0431\u044b\u0442\u0438\u0439<\/li>\n<li>Period measurement<\/li>\n<li>Pulse-width measurement<\/li>\n<li>Encoder acquisition<\/li>\n<li>\u0413\u0435\u043d\u0435\u0440\u0430\u0446\u0438\u044f \u0438\u043c\u043f\u0443\u043b\u044c\u0441\u043e\u0432<\/li>\n<\/ul>\n<h3>Encoder Measurement<\/h3>\n<p>\nCompatible incremental encoder signals can be acquired using the counter\/timer subsystem.\n<\/p>\n<p>\nA typical architecture is:\n<\/p>\n<p>\n<strong>Encoder A\/B\/Z \u2192 USB-6229 Counter \u2192 Position \/ Direction \u2192 Host Application<\/strong>\n<\/p>\n<p>\nThis allows motion-related measurements to be combined with analog and digital data acquisition.\n<\/p>\n<h3>Frequency Measurement<\/h3>\n<p>\nThe USB-6229 can use its hardware counters to measure compatible digital pulse frequencies.\n<\/p>\n<p>\nPossible signal sources include:\n<\/p>\n<ul>\n<li>Tachometers<\/li>\n<li>Pulse-output sensors<\/li>\n<li>Encoders<\/li>\n<li>Digital oscillators<\/li>\n<li>Rotational speed sensors<\/li>\n<\/ul>\n<h3>Hardware Triggering<\/h3>\n<p>\nHardware triggering allows measurement operations to begin or coordinate according to an external or internally routed event.\n<\/p>\n<p>\nA typical triggered acquisition architecture is:\n<\/p>\n<p>\n<strong>External Trigger \u2192 USB-6229 \u2192 Analog Acquisition \u2192 USB \u2192 Host Application<\/strong>\n<\/p>\n<p>\nThis is useful for capturing specific DUT events and synchronizing measurement operations.\n<\/p>\n<h3>Sensor Measurement<\/h3>\n<p>\nThe USB-6229 directly measures compatible voltage signals. Many sensors require external signal conditioning before connection to a multifunction DAQ device.\n<\/p>\n<p>\nSignal conditioning may be required for:\n<\/p>\n<ul>\n<li>\u0422\u0435\u0440\u043c\u043e\u043f\u0430\u0440\u044b<\/li>\n<li>\u0420\u0422\u0414<\/li>\n<li>Strain gauges<\/li>\n<li>Load cells<\/li>\n<li>IEPE accelerometers<\/li>\n<li>Current signals<\/li>\n<li>High-voltage signals<\/li>\n<\/ul>\n<p>\nAlways verify signal level, grounding, isolation, excitation, bandwidth, and sensor requirements before connecting a sensor to the USB-6229.\n<\/p>\n<h3>USB-6229 vs PCI-6229<\/h3>\n<p>\nThe USB-6229 and PCI-6229 belong to the same M Series multifunction DAQ family but use different host interfaces.\n<\/p>\n<table>\n<tr>\n<th>\u0424\u0443\u043d\u043a\u0446\u0438\u044f<\/th>\n<th>USB-6229<\/th>\n<th>PCI-6229<\/th>\n<\/tr>\n<tr>\n<td>Host Interface<\/td>\n<td><strong>USB<\/strong><\/td>\n<td>PCI<\/td>\n<\/tr>\n<tr>\n<td>Analog Inputs<\/td>\n<td>32 SE \/ 16 DI<\/td>\n<td>32 SE \/ 16 DI<\/td>\n<\/tr>\n<tr>\n<td>Maximum AI Rate<\/td>\n<td>250 kS\/s<\/td>\n<td>250 kS\/s<\/td>\n<\/tr>\n<tr>\n<td>Analog Outputs<\/td>\n<td>4<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<td>\u0426\u0438\u0444\u0440\u043e\u0432\u043e\u0439 \u0432\u0432\u043e\u0434-\u0432\u044b\u0432\u043e\u0434<\/td>\n<td>48<\/td>\n<td>48<\/td>\n<\/tr>\n<tr>\n<td>Installation<\/td>\n<td><strong>External<\/strong><\/td>\n<td>Internal PC Card<\/td>\n<\/tr>\n<tr>\n<td>Typical Advantage<\/td>\n<td>Easy USB Connectivity<\/td>\n<td>Internal Desktop Integration<\/td>\n<\/tr>\n<\/table>\n<h3>USB-6229 vs PCIe-6323<\/h3>\n<p>\nThe USB-6229 is an M Series USB device, while newer PCI Express multifunction DAQ devices such as the PCIe-6323 belong to the X Series family.\n<\/p>\n<p>\nWhen comparing these devices, consider:\n<\/p>\n<ul>\n<li>USB versus PCI Express interface<\/li>\n<li>Analog input channel count<\/li>\n<li>Sampling performance<\/li>\n<li>Digital I\/O requirements<\/li>\n<li>Counter\/timer architecture<\/li>\n<li>Hardware timing requirements<\/li>\n<li>System expansion requirements<\/li>\n<\/ul>\n<h3>USB-6229 vs Simultaneous-Sampling DAQ<\/h3>\n<table>\n<tr>\n<th>\u0424\u0443\u043d\u043a\u0446\u0438\u044f<\/th>\n<th>USB-6229<\/th>\n<th>Simultaneous-Sampling DAQ<\/th>\n<\/tr>\n<tr>\n<td>Analog Input Architecture<\/td>\n<td><strong>Multiplexed<\/strong><\/td>\n<td>\u0421\u0438\u043d\u0445\u0440\u043e\u043d\u043d\u044b\u0439<\/td>\n<\/tr>\n<tr>\n<td>Channel Density<\/td>\n<td><strong>High<\/strong><\/td>\n<td>Usually Lower<\/td>\n<\/tr>\n<tr>\n<td>Interchannel Sampling<\/td>\n<td>Sequential<\/td>\n<td><strong>Same-Time Sampling<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Phase-Sensitive Measurement<\/td>\n<td>Limited by Multiplexing<\/td>\n<td><strong>Better Suited<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Typical Application<\/td>\n<td>General Data Acquisition<\/td>\n<td>Dynamic \/ Phase-Related Measurement<\/td>\n<\/tr>\n<\/table>\n<h3>USB-6229 vs CompactDAQ<\/h3>\n<p>\nThe USB-6229 provides fixed multifunction I\/O in a single device, while CompactDAQ uses a modular chassis and interchangeable C Series modules.\n<\/p>\n<table>\n<tr>\n<th>\u0424\u0443\u043d\u043a\u0446\u0438\u044f<\/th>\n<th>USB-6229<\/th>\n<th>\u041a\u043e\u043c\u043f\u0430\u043a\u0442\u043d\u044b\u0439 \u0426\u0410\u041f<\/th>\n<\/tr>\n<tr>\n<td>Architecture<\/td>\n<td><strong>Fixed Multifunction DAQ<\/strong><\/td>\n<td>Modular<\/td>\n<\/tr>\n<tr>\n<td>Module Replacement<\/td>\n<td>No<\/td>\n<td><strong>\u0414\u0430<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Built-In Analog and Digital I\/O<\/td>\n<td><strong>\u0414\u0430<\/strong><\/td>\n<td>Depends on Installed Modules<\/td>\n<\/tr>\n<tr>\n<td>Sensor-Specific Conditioning<\/td>\n<td>External When Required<\/td>\n<td><strong>Available Through C Series Modules<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Expansion Flexibility<\/td>\n<td>Fixed<\/td>\n<td><strong>High<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Typical Advantage<\/td>\n<td>Simple Multifunction Architecture<\/td>\n<td>Flexible Sensor Measurement Platform<\/td>\n<\/tr>\n<\/table>\n<h3>NI-DAQmx Integration<\/h3>\n<p>\nThe USB-6229 uses the <strong>\u041d\u0418-DAQmx<\/strong> driver for device configuration and programming.\n<\/p>\n<p>\nNI-DAQmx supports measurement tasks including:\n<\/p>\n<ul>\n<li>Analog input<\/li>\n<li>Analog output<\/li>\n<li>Digital input<\/li>\n<li>Digital output<\/li>\n<li>Counter input<\/li>\n<li>Counter output<\/li>\n<li>Timing<\/li>\n<li>\u0417\u0430\u043f\u0443\u0441\u043a<\/li>\n<\/ul>\n<h3>LabVIEW Integration<\/h3>\n<p>\nThe USB-6229 can be used with compatible versions of <strong>\u041b\u0430\u0431\u0412\u044c\u044e<\/strong> through NI-DAQmx.\n<\/p>\n<p>\nA typical data acquisition workflow is:\n<\/p>\n<p>\n<strong>Create DAQmx Task \u2192 Configure Channels \u2192 Configure Timing \u2192 Configure Trigger \u2192 Start \u2192 Read Data \u2192 Analyze \/ Log \u2192 Stop<\/strong>\n<\/p>\n<p>\nThe same application can combine analog, digital, and counter measurements according to the test requirements.\n<\/p>\n<h3>Legacy System Replacement<\/h3>\n<p>\nThe USB-6229 is frequently encountered in existing laboratory, research, and automated test systems.\n<\/p>\n<p>\nWhen replacing an existing USB-6229, verify:\n<\/p>\n<ul>\n<li>Exact model and part number<\/li>\n<li>Analog input channel configuration<\/li>\n<li>Terminal configuration<\/li>\n<li>Analog output requirements<\/li>\n<li>Digital I\/O wiring<\/li>\n<li>Counter\/timer usage<\/li>\n<li>USB interface<\/li>\n<li>Connector and cable configuration<\/li>\n<li>NI-DAQmx version<\/li>\n<li>LabVIEW version<\/li>\n<li>Operating system compatibility<\/li>\n<li>Existing application software<\/li>\n<\/ul>\n<p>\nReplacing the device with a newer DAQ model may require changes to wiring, connectors, software configuration, timing, or application code.\n<\/p>\n<h3>How to Choose a Multifunction DAQ Device<\/h3>\n<p>\nBefore selecting the USB-6229, evaluate:\n<\/p>\n<ul>\n<li>Required analog input channel count<\/li>\n<li>Single-ended or differential measurement<\/li>\n<li>Required aggregate sampling rate<\/li>\n<li>Signal voltage range<\/li>\n<li>Required resolution<\/li>\n<li>Analog output requirements<\/li>\n<li>Digital I\/O requirements<\/li>\n<li>Counter\/timer requirements<\/li>\n<li>USB connectivity requirements<\/li>\n<li>Triggering requirements<\/li>\n<li>Signal-conditioning requirements<\/li>\n<li>Connector and cable requirements<\/li>\n<li>NI-DAQmx compatibility<\/li>\n<li>Operating system compatibility<\/li>\n<\/ul>\n<h3>Industries<\/h3>\n<ul>\n<li>Automated Test<\/li>\n<li>Industrial Measurement<\/li>\n<li>Electronics Testing<\/li>\n<li>Research and Development<\/li>\n<li>Laboratory Automation<\/li>\n<li>Education<\/li>\n<li>Manufacturing Test<\/li>\n<li>\u041c\u043e\u043d\u0438\u0442\u043e\u0440\u0438\u043d\u0433 \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u043e\u0432<\/li>\n<li>Control-System Development<\/li>\n<li>Prototype Validation<\/li>\n<\/ul>\n<h3>Applications<\/h3>\n<h4>\u041c\u043d\u043e\u0433\u043e\u043a\u0430\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0441\u0431\u043e\u0440 \u0434\u0430\u043d\u043d\u044b\u0445<\/h4>\n<p>\nWith up to 32 single-ended analog input channels, the USB-6229 is suitable for systems requiring acquisition from multiple voltage signals.\n<\/p>\n<h4>Automated Test<\/h4>\n<p>\nAnalog input, analog output, digital I\/O, and counters can be combined to create multifunction automated test systems.\n<\/p>\n<h4>Data Logging<\/h4>\n<p>\nThe USB-6229 can acquire and log multiple conditioned sensor and voltage signals for laboratory and industrial monitoring applications.\n<\/p>\n<h4>Electronic Validation<\/h4>\n<p>\nAnalog outputs can stimulate a DUT while analog and digital inputs measure the resulting response.\n<\/p>\n<h4>Laboratory Measurement<\/h4>\n<p>\nUSB connectivity and multifunction I\/O make the USB-6229 convenient for desktop laboratory experiments and research systems.\n<\/p>\n<h4>Control Applications<\/h4>\n<p>\nAnalog and digital outputs can be combined with measurement inputs for compatible monitoring and control applications.\n<\/p>\n<h3>Recommended Related Products<\/h3>\n<table>\n<tr>\n<td width=\"220\"><strong>USB-6229<\/strong><\/td>\n<td>High-channel-count USB M Series multifunction DAQ device with 32 analog inputs and 48 digital I\/O lines.<\/td>\n<\/tr>\n<tr>\n<td><strong>PCI-6229<\/strong><\/td>\n<td>PCI version for desktop systems requiring similar M Series multifunction DAQ functionality.<\/td>\n<\/tr>\n<tr>\n<td><strong>PXI-6229<\/strong><\/td>\n<td>PXI platform version for modular automated test and measurement systems.<\/td>\n<\/tr>\n<tr>\n<td><strong>USB-6259<\/strong><\/td>\n<td>Higher-performance M Series USB multifunction DAQ option for applications requiring faster analog acquisition.<\/td>\n<\/tr>\n<tr>\n<td><strong>USB-6363<\/strong><\/td>\n<td>X Series USB multifunction DAQ option for newer high-performance data acquisition and automated test systems.<\/td>\n<\/tr>\n<\/table>\n<h3>Why Choose USB-6229?<\/h3>\n<ul>\n<li>32 single-ended or 16 differential analog inputs<\/li>\n<li>250 kS\/s aggregate analog input sampling<\/li>\n<li>16-bit analog input resolution<\/li>\n<li>Programmable input ranges up to \u00b110 V<\/li>\n<li>4 \u0430\u043d\u0430\u043b\u043e\u0433\u043e\u0432\u044b\u0445 \u0432\u044b\u0445\u043e\u0434\u043d\u044b\u0445 \u043a\u0430\u043d\u0430\u043b\u0430<\/li>\n<li>16-bit analog output resolution<\/li>\n<li>48 digital I\/O lines<\/li>\n<li>Two 32-bit counter\/timers<\/li>\n<li>USB connectivity<\/li>\n<li>NI M Series multifunction architecture<\/li>\n<li>Hardware timing and triggering<\/li>\n<li>NI-DAQmx support<\/li>\n<li>\u0418\u043d\u0442\u0435\u0433\u0440\u0430\u0446\u0438\u044f LabVIEW<\/li>\n<li>High channel density<\/li>\n<li>Automated test applications<\/li>\n<li>Multi-channel data logging<\/li>\n<li>Laboratory measurement<\/li>\n<\/ul>\n<h3>Frequently Asked Questions<\/h3>\n<h4>What is the NI USB-6229?<\/h4>\n<p>\nThe NI USB-6229 is an M Series USB multifunction DAQ device that combines analog input, analog output, digital I\/O, and hardware counter\/timer functionality for data acquisition and automated test applications.\n<\/p>\n<h4>How many analog input channels does USB-6229 have?<\/h4>\n<p>\nThe USB-6229 supports up to <strong>32 single-ended or 16 differential analog input channels<\/strong>.\n<\/p>\n<h4>What is the maximum sample rate of USB-6229?<\/h4>\n<p>\nThe USB-6229 supports an aggregate analog input sampling rate of up to <strong>250 kS\/s<\/strong>.\n<\/p>\n<h4>Does USB-6229 provide 250 kS\/s on every analog input channel?<\/h4>\n<p>\nNo. The USB-6229 uses a multiplexed analog input architecture. The 250 kS\/s specification represents the maximum aggregate sampling rate rather than 250 kS\/s independently on every channel.\n<\/p>\n<h4>What is the analog input resolution of USB-6229?<\/h4>\n<p>\nThe USB-6229 provides <strong>16-bit analog input resolution<\/strong>.\n<\/p>\n<h4>What is the analog input range of USB-6229?<\/h4>\n<p>\nThe USB-6229 supports programmable bipolar input ranges up to approximately <strong>\u00b110 V<\/strong>, with smaller ranges available for lower-amplitude signals.\n<\/p>\n<h4>How many analog outputs does USB-6229 have?<\/h4>\n<p>\nThe USB-6229 provides <strong>4 \u0430\u043d\u0430\u043b\u043e\u0433\u043e\u0432\u044b\u0445 \u0432\u044b\u0445\u043e\u0434\u043d\u044b\u0445 \u043a\u0430\u043d\u0430\u043b\u0430<\/strong>.\n<\/p>\n<h4>How many digital I\/O lines does USB-6229 have?<\/h4>\n<p>\nThe USB-6229 provides <strong>48 digital I\/O lines<\/strong>.\n<\/p>\n<h4>How many counter\/timers does USB-6229 have?<\/h4>\n<p>\nThe device provides <strong>two 32-bit counter\/timers<\/strong> for frequency, period, pulse, encoder, and event-counting applications.\n<\/p>\n<h4>Can USB-6229 measure encoder signals?<\/h4>\n<p>\nYes. Compatible encoder signals can be measured using the hardware counter\/timer resources.\n<\/p>\n<h4>Can USB-6229 generate analog signals?<\/h4>\n<p>\nYes. Its four analog output channels can generate programmable voltage signals for stimulus, simulation, test, and control applications.\n<\/p>\n<h4>Is USB-6229 a simultaneous-sampling DAQ device?<\/h4>\n<p>\nNo. The USB-6229 uses a <strong>multiplexed analog input architecture<\/strong>. Applications requiring true simultaneous sampling should use a DAQ device specifically designed with simultaneous ADC channels.\n<\/p>\n<h4>Can USB-6229 measure thermocouples directly?<\/h4>\n<p>\nThe USB-6229 is primarily a voltage measurement device. Accurate thermocouple measurement typically requires appropriate signal conditioning and cold-junction compensation. A sensor-specific DAQ solution may be more appropriate for dedicated temperature measurement applications.\n<\/p>\n<h4>What software is used with USB-6229?<\/h4>\n<p>\nThe USB-6229 uses the <strong>\u041d\u0418-DAQmx<\/strong> driver and can be integrated with compatible LabVIEW and other NI-DAQmx-supported development environments.\n<\/p>\n<h4>What is the difference between USB-6229 and PCI-6229?<\/h4>\n<p>\nThe primary difference is the host interface and physical architecture. The USB-6229 is an external USB device, while the PCI-6229 installs internally in a compatible PCI slot.\n<\/p>\n<h4>What is the difference between USB-6229 and USB-6259?<\/h4>\n<p>\nBoth belong to the M Series multifunction DAQ family. The USB-6259 targets applications requiring higher analog acquisition performance, while the USB-6229 is suitable for general-purpose high-channel-count data acquisition where 250 kS\/s aggregate sampling is sufficient.\n<\/p>\n<h4>Is USB-6229 suitable for automated test?<\/h4>\n<p>\nYes. Its combination of analog inputs, analog outputs, digital I\/O, counters, triggering, and USB connectivity makes it suitable for many automated functional test and electronic validation applications.\n<\/p>\n<h4>What should I check before purchasing USB-6229?<\/h4>\n<p>\nVerify the required analog input channel count, single-ended or differential configuration, aggregate sampling rate, input voltage range, analog output requirements, digital I\/O count, counter\/timer requirements, connector and cable configuration, USB interface, signal-conditioning requirements, NI-DAQmx version, operating system, and application software compatibility.\n<\/p>\n<h3>\u0417\u0430\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435<\/h3>\n<p>\n\u0417\u0435\u043c\u043b\u044f <strong>NI USB-6229 M Series Multifunction DAQ Device<\/strong> combines up to 32 single-ended or 16 differential analog inputs, 16-bit resolution, 250 kS\/s aggregate sampling, four analog outputs, 48 digital I\/O lines, hardware counter\/timers, triggering, and convenient USB connectivity. Its high I\/O channel density and multifunction architecture make it well suited for automated test, multi-channel data logging, laboratory measurement, electronic validation, research, and general-purpose data acquisition systems.<\/p>","protected":false},"excerpt":{"rendered":"<p>\u041a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u0434\u0432\u0443\u043d\u0430\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u043d\u044b\u0445 \u0446\u0438\u0444\u0440\u043e\u0432\u044b\u0445 \u043a\u0430\u043d\u0430\u043b\u043e\u0432: 48<br \/>\nSupported Power Input: Korea 220VAC<br \/>\n\u041c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u0435 \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u043e\u0434\u043d\u043e\u043a\u0430\u043d\u0430\u043b\u044c\u043d\u044b\u0445 \u0430\u043d\u0430\u043b\u043e\u0433\u043e\u0432\u044b\u0445 \u0432\u0445\u043e\u0434\u043d\u044b\u0445 \u043a\u0430\u043d\u0430\u043b\u043e\u0432: 32<br \/>\nNumber of Counters\/Timers: 2<br \/>\nAnalog Input Absolute Accuracy: 3100 \u03bcV<br \/>\n\u041e\u0434\u043d\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u0430\u044f \u0432\u044b\u0431\u043e\u0440\u043a\u0430: \u041d\u0435\u0442<br \/>\n\u0412 \u043a\u043e\u043c\u043f\u043b\u0435\u043a\u0442 \u0432\u0445\u043e\u0434\u0438\u0442: \u0414\u0430<br \/>\n\u0420\u0430\u0437\u0440\u0435\u0448\u0435\u043d\u0438\u0435 \u0430\u043d\u0430\u043b\u043e\u0433\u043e\u0432\u043e\u0433\u043e \u0432\u0445\u043e\u0434\u0430: 16 \u0431\u0438\u0442<br \/>\nFront Connection Type: Screw Terminal(1)#BNC(30)<br \/>\n\u041a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u0430\u043d\u0430\u043b\u043e\u0433\u043e\u0432\u044b\u0445 \u0432\u044b\u0445\u043e\u0434\u043d\u044b\u0445 \u043a\u0430\u043d\u0430\u043b\u043e\u0432: 4<\/p>","protected":false},"featured_media":33672,"template":"","meta":{"_acf_changed":false},"product_brand":[18],"product_cat":[674],"product_tag":[],"class_list":["post-34660","product","type-product","status-publish","has-post-thumbnail","product_brand-national-instruments","product_cat-pci-usb","first","instock","shipping-taxable","product-type-simple"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.0 (Yoast SEO v28.1) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>NI USB-6229 USB Multifunction I\/O Device 780116-02, In Stock | Project Pricing<\/title>\n<meta name=\"description\" content=\"NI USB-6229 is a USB M Series multifunction DAQ device with 32 analog inputs, 250 kS\/s sampling, 4 analog outputs and 48 digital I\/O lines for test and measurement.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/pxisource.com\/ru\/product\/usb-6229\/\" \/>\n<meta property=\"og:locale\" content=\"ru_RU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"USB-6229\" \/>\n<meta property=\"og:description\" content=\"NI USB-6229 is a USB M Series multifunction DAQ device with 32 analog inputs, 250 kS\/s sampling, 4 analog outputs and 48 digital I\/O lines for test and measurement.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/pxisource.com\/ru\/product\/usb-6229\/\" \/>\n<meta property=\"og:site_name\" content=\"PXI Source\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=61582573040385\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-27T10:48:13+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/07\/USB-6229.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"800\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u0426\u0435\u043d\u0430\" \/>\n\t<meta name=\"twitter:data1\" content=\"\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c\" \/>\n\t<meta name=\"twitter:data2\" content=\"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/usb-6229\\\/\",\"url\":\"https:\\\/\\\/pxisource.com\\\/product\\\/usb-6229\\\/\",\"name\":\"NI USB-6229 USB Multifunction I\\\/O Device 780116-02, In Stock | Project Pricing\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/usb-6229\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/usb-6229\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/USB-6229.webp\",\"datePublished\":\"2026-08-07T05:27:35+00:00\",\"dateModified\":\"2026-08-27T10:48:13+00:00\",\"description\":\"NI USB-6229 is a USB M Series multifunction DAQ device with 32 analog inputs, 250 kS\\\/s sampling, 4 analog outputs and 48 digital I\\\/O lines for test and measurement.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/usb-6229\\\/#breadcrumb\"},\"inLanguage\":\"ru-RU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/pxisource.com\\\/product\\\/usb-6229\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/usb-6229\\\/#primaryimage\",\"url\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/USB-6229.webp\",\"contentUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/USB-6229.webp\",\"width\":800,\"height\":800,\"caption\":\"USB-6229\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/usb-6229\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/pxisource.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u5546\u5e97\",\"item\":\"https:\\\/\\\/pxisource.com\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"USB-6229\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\",\"url\":\"https:\\\/\\\/pxisource.com\\\/\",\"name\":\"PXI Systems\",\"description\":\"PXI, PXIe and Modular Test Equipment\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/pxisource.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ru-RU\"}]}<\/script>\n<meta property=\"product:brand\" content=\"National Instruments\" \/>\n<meta property=\"product:price:currency\" content=\"USD\" \/>\n<meta property=\"og:availability\" content=\"instock\" \/>\n<meta property=\"product:availability\" content=\"instock\" \/>\n<meta property=\"product:condition\" content=\"new\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"NI USB-6229 USB Multifunction I\/O Device 780116-02, In Stock | Project Pricing","description":"NI USB-6229 is a USB M Series multifunction DAQ device with 32 analog inputs, 250 kS\/s sampling, 4 analog outputs and 48 digital I\/O lines for test and measurement.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/pxisource.com\/ru\/product\/usb-6229\/","og_locale":"ru_RU","og_type":"article","og_title":"USB-6229","og_description":"NI USB-6229 is a USB M Series multifunction DAQ device with 32 analog inputs, 250 kS\/s sampling, 4 analog outputs and 48 digital I\/O lines for test and measurement.","og_url":"https:\/\/pxisource.com\/ru\/product\/usb-6229\/","og_site_name":"PXI Source","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=61582573040385","article_modified_time":"2026-08-27T10:48:13+00:00","og_image":[{"width":800,"height":800,"url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/07\/USB-6229.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"\u0426\u0435\u043d\u0430":"","\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c":"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/pxisource.com\/product\/usb-6229\/","url":"https:\/\/pxisource.com\/product\/usb-6229\/","name":"NI USB-6229 USB Multifunction I\/O Device 780116-02, In Stock | Project Pricing","isPartOf":{"@id":"https:\/\/pxisource.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/pxisource.com\/product\/usb-6229\/#primaryimage"},"image":{"@id":"https:\/\/pxisource.com\/product\/usb-6229\/#primaryimage"},"thumbnailUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/07\/USB-6229.webp","datePublished":"2026-08-07T05:27:35+00:00","dateModified":"2026-08-27T10:48:13+00:00","description":"NI USB-6229 is a USB M Series multifunction DAQ device with 32 analog inputs, 250 kS\/s sampling, 4 analog outputs and 48 digital I\/O lines for test and measurement.","breadcrumb":{"@id":"https:\/\/pxisource.com\/product\/usb-6229\/#breadcrumb"},"inLanguage":"ru-RU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/pxisource.com\/product\/usb-6229\/"]}]},{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/pxisource.com\/product\/usb-6229\/#primaryimage","url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/07\/USB-6229.webp","contentUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/07\/USB-6229.webp","width":800,"height":800,"caption":"USB-6229"},{"@type":"BreadcrumbList","@id":"https:\/\/pxisource.com\/product\/usb-6229\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/pxisource.com\/"},{"@type":"ListItem","position":2,"name":"\u5546\u5e97","item":"https:\/\/pxisource.com\/shop\/"},{"@type":"ListItem","position":3,"name":"USB-6229"}]},{"@type":"WebSite","@id":"https:\/\/pxisource.com\/#website","url":"https:\/\/pxisource.com\/","name":"\u0421\u0438\u0441\u0442\u0435\u043c\u044b PXI","description":"PXI, PXIe and Modular Test Equipment","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/pxisource.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ru-RU"}]},"product_brand":"National Instruments","product_price_currency":"USD","og_availability":"instock","product_availability":"instock","product_condition":"new"},"_links":{"self":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/34660","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":3,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/34660\/revisions"}],"predecessor-version":[{"id":35506,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/34660\/revisions\/35506"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media\/33672"}],"wp:attachment":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media?parent=34660"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_brand?post=34660"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_cat?post=34660"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_tag?post=34660"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}