{"id":34646,"date":"2026-08-07T13:22:09","date_gmt":"2026-08-07T05:22:09","guid":{"rendered":"https:\/\/pxisource.com\/?post_type=product&#038;p=34646"},"modified":"2026-08-27T14:13:54","modified_gmt":"2026-08-27T06:13:54","slug":"pci-6230","status":"publish","type":"product","link":"https:\/\/pxisource.com\/ru\/product\/pci-6230\/","title":{"rendered":"PCI-6230"},"content":{"rendered":"<h3>Product Introduction<\/h3>\n<p>\n\u0417\u0435\u043c\u043b\u044f <strong>NI PCI-6230<\/strong> \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f <strong>isolated M Series multifunction data acquisition (DAQ) device<\/strong> designed for PCI-based measurement, control, and automated test systems. It combines analog input, analog output, digital I\/O, counters\/timers, hardware timing, and bank isolation on a single PCI DAQ board.\n<\/p>\n<p>\nThe PCI-6230 provides up to <strong>8 single-ended or 4 differential analog input channels<\/strong> \u0441 <strong>16-\u0431\u0438\u0442\u043d\u043e\u0435 \u0440\u0430\u0437\u0440\u0435\u0448\u0435\u043d\u0438\u0435<\/strong> and a maximum sampling rate of <strong>250 kS\/s<\/strong>. It also includes <strong>4 analog output channels, 6 digital input lines, 4 digital output lines, and two 32-bit counters\/timers<\/strong>.\n<\/p>\n<p>\nOne of the most important characteristics of the PCI-6230 is its <strong>bank-isolated I\/O architecture<\/strong>. Isolation helps protect the measurement system and reduce problems caused by ground potential differences, making the PCI-6230 particularly useful in industrial measurement, automated test, machine monitoring, and electrically noisy environments.\n<\/p>\n<h3>Product Overview<\/h3>\n<p>\n\u0417\u0435\u043c\u043b\u044f <strong>National Instruments PCI-6230<\/strong> integrates multiple measurement and control functions into one PCI device.\n<\/p>\n<p>\nA typical system architecture is:\n<\/p>\n<p>\n<strong>Sensors \/ Voltage Signals \u2192 PCI-6230 \u2192 PCI Bus \u2192 Host Computer \u2192 NI-DAQmx \/ LabVIEW<\/strong>\n<\/p>\n<p>\nAt the same time, the device can generate analog signals, monitor digital inputs, control digital outputs, and perform counter\/timer measurements.\n<\/p>\n<h3>Key Features<\/h3>\n<h4>8 Analog Input Channels<\/h4>\n<p>\nThe PCI-6230 provides up to <strong>8 single-ended analog input channels<\/strong> for acquiring voltage signals from sensors, transducers, electronic circuits, and other measurement sources.\n<\/p>\n<p>\nFor applications requiring differential measurements, the device supports up to <strong>4 differential analog input channels<\/strong>.\n<\/p>\n<h4>16-Bit Analog Input Resolution<\/h4>\n<p>\nThe analog-to-digital converter provides <strong>16-\u0431\u0438\u0442\u043d\u043e\u0435 \u0440\u0430\u0437\u0440\u0435\u0448\u0435\u043d\u0438\u0435<\/strong>, allowing the PCI-6230 to capture detailed voltage measurements for industrial, laboratory, and automated test applications.\n<\/p>\n<h4>250 kS\/s Maximum Sample Rate<\/h4>\n<p>\nThe PCI-6230 provides a maximum single-channel analog input sampling rate of <strong>250 kS\/s<\/strong>.\n<\/p>\n<p>\nThis acquisition rate is suitable for many sensor measurement, monitoring, control, and electronic test applications.\n<\/p>\n<h4>Multiple Analog Input Ranges<\/h4>\n<p>\nThe PCI-6230 supports multiple programmable analog input ranges, including:\n<\/p>\n<ul>\n<li>\u00b10.2 V<\/li>\n<li>\u00b11 V<\/li>\n<li>\u00b15 V<\/li>\n<li>\u00b110 V<\/li>\n<\/ul>\n<p>\nSelecting an appropriate input range can improve measurement resolution for signals with different voltage levels.\n<\/p>\n<h4>4 Analog Output Channels<\/h4>\n<p>\nThe PCI-6230 provides <strong>4 \u0430\u043d\u0430\u043b\u043e\u0433\u043e\u0432\u044b\u0445 \u0432\u044b\u0445\u043e\u0434\u043d\u044b\u0445 \u043a\u0430\u043d\u0430\u043b\u0430<\/strong>, allowing the same DAQ device to perform both signal acquisition and analog signal generation.\n<\/p>\n<p>\nAnalog outputs can be used for:\n<\/p>\n<ul>\n<li>Control voltage generation<\/li>\n<li>Device excitation<\/li>\n<li>Test stimulus generation<\/li>\n<li>Programmable setpoints<\/li>\n<li>\u0417\u0430\u043c\u043a\u043d\u0443\u0442\u0430\u044f \u0441\u0438\u0441\u0442\u0435\u043c\u0430 \u0443\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u0438\u044f<\/li>\n<li>Automated device testing<\/li>\n<\/ul>\n<h4>6 Digital Inputs<\/h4>\n<p>\nThe PCI-6230 provides <strong>6 digital input lines<\/strong> for monitoring digital states and external equipment.\n<\/p>\n<p>\n\u0422\u0438\u043f\u0438\u0447\u043d\u044b\u0435 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f \u0432\u043a\u043b\u044e\u0447\u0430\u044e\u0442:\n<\/p>\n<ul>\n<li>Equipment status monitoring<\/li>\n<li>Limit switch detection<\/li>\n<li>External trigger detection<\/li>\n<li>Machine-state monitoring<\/li>\n<li>Digital event detection<\/li>\n<\/ul>\n<h4>4 Digital Outputs<\/h4>\n<p>\nThe device also provides <strong>4 digital output lines<\/strong> for controlling compatible external digital devices.\n<\/p>\n<p>\nDigital outputs can be used for control signals, indicators, external logic, relays through appropriate interfacing circuitry, and automated test sequencing.\n<\/p>\n<h4>5 V TTL\/CMOS Digital I\/O<\/h4>\n<p>\nThe PCI-6230 digital interface is designed for <strong>5 V TTL\/CMOS<\/strong> digital signaling.\n<\/p>\n<p>\nSignal voltage levels and current requirements should always be verified before connecting external equipment directly to the digital I\/O terminals.\n<\/p>\n<h4>Bank Isolation<\/h4>\n<p>\nA major advantage of the PCI-6230 is its <strong>bank isolation<\/strong>.\n<\/p>\n<p>\nElectrical isolation helps separate sections of the measurement hardware from the host computer and can reduce problems associated with:\n<\/p>\n<ul>\n<li>Ground loops<\/li>\n<li>Ground potential differences<\/li>\n<li>Electrical noise<\/li>\n<li>Industrial equipment interference<\/li>\n<li>Transient disturbances<\/li>\n<\/ul>\n<p>\nThis makes the PCI-6230 particularly useful for industrial and automated test applications where measurement signals may not share the same ground potential as the host computer.\n<\/p>\n<h4>Two 32-Bit Counters\/Timers<\/h4>\n<p>\nThe PCI-6230 provides <strong>two 32-bit counters\/timers<\/strong> for timing and digital measurement applications.\n<\/p>\n<p>\nCounter\/timer functions can be used for:\n<\/p>\n<ul>\n<li>\u041f\u043e\u0434\u0441\u0447\u0435\u0442 \u0441\u043e\u0431\u044b\u0442\u0438\u0439<\/li>\n<li>Frequency measurement<\/li>\n<li>Period measurement<\/li>\n<li>Pulse-width measurement<\/li>\n<li>Encoder measurements<\/li>\n<li>\u0413\u0435\u043d\u0435\u0440\u0430\u0446\u0438\u044f \u0438\u043c\u043f\u0443\u043b\u044c\u0441\u043e\u0432<\/li>\n<li>Digital timing<\/li>\n<\/ul>\n<h4>PCI Host Interface<\/h4>\n<p>\nThe PCI-6230 installs directly into a compatible conventional <strong>PCI slot<\/strong> in a desktop, industrial, or rackmount computer.\n<\/p>\n<p>\nThis makes the device particularly relevant for maintaining existing PCI-based automated test and industrial measurement systems.\n<\/p>\n<h4>NI-DAQmx Support<\/h4>\n<p>\nThe PCI-6230 is supported by <strong>\u041d\u0418-DAQmx<\/strong>, which provides hardware configuration, measurement, timing, triggering, generation, and programming functionality.\n<\/p>\n<p>\nNI-DAQmx allows the PCI-6230 to be integrated into LabVIEW and other compatible application development environments.\n<\/p>\n<h3>Technical Specifications<\/h3>\n<table>\n<tr>\n<th>\u041f\u0430\u0440\u0430\u043c\u0435\u0442\u0440<\/th>\n<th>\u0421\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f<\/th>\n<\/tr>\n<tr>\n<td width=\"280\">Product Type<\/td>\n<td>Isolated M Series Multifunction DAQ Device<\/td>\n<\/tr>\n<tr>\n<td>\u041c\u043e\u0434\u0435\u043b\u044c<\/td>\n<td>PCI-6230<\/td>\n<\/tr>\n<tr>\n<td>Manufacturer<\/td>\n<td>\u041d\u0430\u0446\u0438\u043e\u043d\u0430\u043b\u044c\u043d\u044b\u0435 \u0438\u043d\u0441\u0442\u0440\u0443\u043c\u0435\u043d\u0442\u044b<\/td>\n<\/tr>\n<tr>\n<td>\u0428\u0438\u043d\u043d\u044b\u0439 \u0438\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441<\/td>\n<td>PCI<\/td>\n<\/tr>\n<tr>\n<td>Analog Input Channels<\/td>\n<td>8 Single-Ended \/ 4 Differential<\/td>\n<\/tr>\n<tr>\n<td>Analog Input Resolution<\/td>\n<td>16-Bit<\/td>\n<\/tr>\n<tr>\n<td>Maximum AI Sample Rate<\/td>\n<td>250 kS\/s<\/td>\n<\/tr>\n<tr>\n<td>Analog Input Type<\/td>\n<td>Voltage<\/td>\n<\/tr>\n<tr>\n<td>Input Coupling<\/td>\n<td>DC<\/td>\n<\/tr>\n<tr>\n<td>Analog Input Ranges<\/td>\n<td>\u00b10.2 V, \u00b11 V, \u00b15 V, \u00b110 V<\/td>\n<\/tr>\n<tr>\n<td>Analog Output Channels<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<td>Digital Inputs<\/td>\n<td>6<\/td>\n<\/tr>\n<tr>\n<td>Digital Outputs<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<td>Digital Logic<\/td>\n<td>5 V TTL\/CMOS<\/td>\n<\/tr>\n<tr>\n<td>Counters\/Timers<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>Counter Resolution<\/td>\n<td>32-Bit<\/td>\n<\/tr>\n<tr>\n<td>\u0418\u0437\u043e\u043b\u044f\u0446\u0438\u044f<\/td>\n<td>Bank Isolation<\/td>\n<\/tr>\n<tr>\n<td>I\/O Connector<\/td>\n<td>37-\u043a\u043e\u043d\u0442\u0430\u043a\u0442\u043d\u044b\u0439 D-SUB<\/td>\n<\/tr>\n<tr>\n<td>Driver<\/td>\n<td>\u041d\u0418-DAQmx<\/td>\n<\/tr>\n<tr>\n<td>Primary Applications<\/td>\n<td>Industrial Measurement, Automated Test, Control and Data Acquisition<\/td>\n<\/tr>\n<\/table>\n<h3>How Does the PCI-6230 Work?<\/h3>\n<p>\nThe PCI-6230 provides a multifunction interface between external analog and digital signals and a PCI-based host computer.\n<\/p>\n<p>\nA simplified analog measurement path is:\n<\/p>\n<p>\n<strong>Sensor \/ Voltage Signal \u2192 Isolated Input Circuitry \u2192 Multiplexer \u2192 16-Bit ADC \u2192 PCI Bus \u2192 Host Application<\/strong>\n<\/p>\n<p>\nThe host application can acquire analog measurements while also controlling analog outputs, monitoring digital inputs, generating digital outputs, and performing counter\/timer operations.\n<\/p>\n<h3>What Is Bank Isolation?<\/h3>\n<p>\nBank isolation electrically separates groups of I\/O circuitry from other parts of the measurement system.\n<\/p>\n<p>\nIn practical measurement systems, isolation can be important when external equipment operates at different ground potentials or when electrical noise could otherwise interfere with measurements.\n<\/p>\n<p>\nCommon applications for isolated DAQ hardware include:\n<\/p>\n<ul>\n<li>\u041f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0435 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435<\/li>\n<li>Motor test systems<\/li>\n<li>Power electronics testing<\/li>\n<li>\u0410\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0437\u0430\u0446\u0438\u044f \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0430<\/li>\n<li>Production equipment monitoring<\/li>\n<li>Electromechanical systems<\/li>\n<li>Automated validation systems<\/li>\n<\/ul>\n<h3>Why Use an Isolated DAQ Device?<\/h3>\n<p>\nA conventional nonisolated DAQ device shares a closer electrical reference with the host computer. In some industrial systems, this can create measurement problems when the external signal source and computer have different ground potentials.\n<\/p>\n<p>\nAn isolated device such as the PCI-6230 can help improve system robustness in these environments.\n<\/p>\n<p>\nIsolation can be especially valuable when:\n<\/p>\n<ul>\n<li>Signals originate from industrial machinery<\/li>\n<li>Long cables introduce ground differences<\/li>\n<li>Multiple powered systems are interconnected<\/li>\n<li>Electrical noise is present<\/li>\n<li>Measurement equipment and sensors use different grounds<\/li>\n<\/ul>\n<h3>Analog Input Measurement<\/h3>\n<p>\nThe PCI-6230 provides eight single-ended or four differential voltage input channels.\n<\/p>\n<p>\nThe appropriate measurement configuration depends on the signal source, grounding architecture, noise environment, and required channel count.\n<\/p>\n<h4>Single-Ended Measurement<\/h4>\n<p>\nSingle-ended operation provides the maximum eight-channel analog input count and can be appropriate when the signals have compatible grounding and noise conditions.\n<\/p>\n<h4>Differential Measurement<\/h4>\n<p>\nDifferential operation uses pairs of input terminals and provides up to four analog input channels.\n<\/p>\n<p>\nDifferential measurement can be useful when improved common-mode noise rejection is required.\n<\/p>\n<h3>Analog Output Applications<\/h3>\n<p>\nUnlike acquisition-only DAQ devices, the PCI-6230 provides four analog outputs for programmable voltage generation.\n<\/p>\n<p>\nThis allows a single board to both stimulate and measure a device under test.\n<\/p>\n<p>\nA typical automated test architecture can be:\n<\/p>\n<p>\n<strong>PCI-6230 AO \u2192 Device Under Test \u2192 PCI-6230 AI \u2192 Test Application<\/strong>\n<\/p>\n<p>\nThis architecture is useful for characterization, control, functional testing, and closed-loop measurement applications.\n<\/p>\n<h3>Digital Input and Output<\/h3>\n<p>\nThe PCI-6230 provides separate digital input and digital output resources.\n<\/p>\n<p>\nDigital inputs can monitor external equipment states, while digital outputs can control compatible external circuitry.\n<\/p>\n<p>\n\u041d\u0430\u043f\u0440\u0438\u043c\u0435\u0440:\n<\/p>\n<p>\n<strong>Digital Input \u2192 Read Machine Status<\/strong><br \/>\n<strong>Digital Output \u2192 Control External Logic<\/strong>\n<\/p>\n<h3>Counter and Timer Applications<\/h3>\n<p>\nThe two 32-bit counters\/timers provide additional measurement and generation capabilities beyond conventional analog and digital I\/O.\n<\/p>\n<p>\n\u0422\u0438\u043f\u0438\u0447\u043d\u044b\u0435 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f \u0432\u043a\u043b\u044e\u0447\u0430\u044e\u0442:\n<\/p>\n<ul>\n<li>Rotational speed measurement<\/li>\n<li>Frequency measurement<\/li>\n<li>\u041f\u043e\u0434\u0441\u0447\u0435\u0442 \u0441\u043e\u0431\u044b\u0442\u0438\u0439<\/li>\n<li>Pulse-width measurement<\/li>\n<li>Encoder position measurement<\/li>\n<li>\u0413\u0435\u043d\u0435\u0440\u0430\u0446\u0438\u044f \u0438\u043c\u043f\u0443\u043b\u044c\u0441\u043e\u0432<\/li>\n<li>Timing measurements<\/li>\n<\/ul>\n<h3>Industrial Measurement<\/h3>\n<p>\nThe isolated architecture of the PCI-6230 makes it particularly suitable for industrial measurement applications.\n<\/p>\n<p>\nTypical measurements can include:\n<\/p>\n<ul>\n<li>Process voltage monitoring<\/li>\n<li>\u041c\u043e\u043d\u0438\u0442\u043e\u0440\u0438\u043d\u0433 \u0441\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u044f \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f<\/li>\n<li>Motor test measurements<\/li>\n<li>Production equipment monitoring<\/li>\n<li>Control-system validation<\/li>\n<li>Industrial sensor acquisition<\/li>\n<\/ul>\n<h3>\u0410\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0437\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0435 \u0438\u0441\u043f\u044b\u0442\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u0441\u0438\u0441\u0442\u0435\u043c\u044b<\/h3>\n<p>\nThe PCI-6230 combines measurement, generation, digital control, and timing functionality for automated test applications.\n<\/p>\n<p>\nA typical automated test sequence can:\n<\/p>\n<ol>\n<li>Configure the analog and digital channels.<\/li>\n<li>Generate a test voltage through an analog output.<\/li>\n<li>Control the device under test through digital outputs.<\/li>\n<li>Acquire analog measurements.<\/li>\n<li>Monitor digital status signals.<\/li>\n<li>Measure frequency or timing signals.<\/li>\n<li>Evaluate pass\/fail limits.<\/li>\n<li>Store the test results.<\/li>\n<\/ol>\n<h3>Machine Monitoring<\/h3>\n<p>\nThe PCI-6230 can be used in machine monitoring systems where multiple voltage and digital signals must be acquired from industrial equipment.\n<\/p>\n<p>\nIsolation can help maintain reliable measurements when the monitored machinery operates in an electrically noisy environment.\n<\/p>\n<h3>Motor and Drive Testing<\/h3>\n<p>\nMotor drives, actuators, and electromechanical equipment often generate electrical noise and ground-potential differences.\n<\/p>\n<p>\nThe isolated I\/O architecture of the PCI-6230 makes it useful for compatible motor and drive test systems where voltage acquisition, digital monitoring, and control signals are required.\n<\/p>\n<h3>Power Electronics Testing<\/h3>\n<p>\nPower electronic devices can require isolated measurement and control interfaces because the device under test and host computer may operate at different electrical potentials.\n<\/p>\n<p>\nThe PCI-6230 can be incorporated into compatible power electronics validation systems, subject to its specified input ranges, working-voltage limits, and isolation ratings.\n<\/p>\n<h3>PCI-6230 vs PXI-6230<\/h3>\n<p>\nThe PCI-6230 and PXI-6230 provide closely related isolated M Series multifunction DAQ functionality but use different host platforms.\n<\/p>\n<table>\n<tr>\n<th>\u0424\u0443\u043d\u043a\u0446\u0438\u044f<\/th>\n<th>PCI-6230<\/th>\n<th>\u041f\u0425\u0418-6230<\/th>\n<\/tr>\n<tr>\n<td>Platform<\/td>\n<td><strong>PCI<\/strong><\/td>\n<td>PXI<\/td>\n<\/tr>\n<tr>\n<td>Analog Inputs<\/td>\n<td>8 SE \/ 4 Differential<\/td>\n<td>8 SE \/ 4 Differential<\/td>\n<\/tr>\n<tr>\n<td>AI Resolution<\/td>\n<td>16-Bit<\/td>\n<td>16-Bit<\/td>\n<\/tr>\n<tr>\n<td>Maximum AI Sample Rate<\/td>\n<td>250 kS\/s<\/td>\n<td>250 kS\/s<\/td>\n<\/tr>\n<tr>\n<td>Analog Outputs<\/td>\n<td>4<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<td>\u0418\u0437\u043e\u043b\u044f\u0446\u0438\u044f<\/td>\n<td>Bank Isolation<\/td>\n<td>Bank Isolation<\/td>\n<\/tr>\n<tr>\n<td>Installation<\/td>\n<td>PCI Computer<\/td>\n<td>PXI \u0428\u0430\u0441\u0441\u0438<\/td>\n<\/tr>\n<tr>\n<td>Best Application<\/td>\n<td>PC-Based Systems<\/td>\n<td>Modular PXI Systems<\/td>\n<\/tr>\n<\/table>\n<h3>PCI-6230 vs Nonisolated Multifunction DAQ<\/h3>\n<table>\n<tr>\n<th>\u0424\u0443\u043d\u043a\u0446\u0438\u044f<\/th>\n<th>PCI-6230<\/th>\n<th>Typical Nonisolated DAQ<\/th>\n<\/tr>\n<tr>\n<td>Electrical Isolation<\/td>\n<td><strong>Bank Isolation<\/strong><\/td>\n<td>Typically No<\/td>\n<\/tr>\n<tr>\n<td>Analog Input<\/td>\n<td>\u0414\u0430<\/td>\n<td>\u0414\u0430<\/td>\n<\/tr>\n<tr>\n<td>Analog Output<\/td>\n<td>\u0414\u0430<\/td>\n<td>Model Dependent<\/td>\n<\/tr>\n<tr>\n<td>\u0426\u0438\u0444\u0440\u043e\u0432\u043e\u0439 \u0432\u0432\u043e\u0434-\u0432\u044b\u0432\u043e\u0434<\/td>\n<td>\u0414\u0430<\/td>\n<td>\u0414\u0430<\/td>\n<\/tr>\n<tr>\n<td>Counters\/Timers<\/td>\n<td>\u0414\u0430<\/td>\n<td>Model Dependent<\/td>\n<\/tr>\n<tr>\n<td>Industrial Ground Differences<\/td>\n<td><strong>Better Suited<\/strong><\/td>\n<td>Requires Careful System Design<\/td>\n<\/tr>\n<tr>\n<td>Primary Strength<\/td>\n<td>Isolated Multifunction I\/O<\/td>\n<td>General-Purpose DAQ<\/td>\n<\/tr>\n<\/table>\n<h3>PCI-6230 vs PCI-6281<\/h3>\n<p>\nThe PCI-6230 and PCI-6281 target different measurement requirements.\n<\/p>\n<table>\n<tr>\n<th>\u0424\u0443\u043d\u043a\u0446\u0438\u044f<\/th>\n<th>PCI-6230<\/th>\n<th>PCI-6281<\/th>\n<\/tr>\n<tr>\n<td>Primary Design<\/td>\n<td><strong>Isolated Multifunction DAQ<\/strong><\/td>\n<td>High-Accuracy Multifunction DAQ<\/td>\n<\/tr>\n<tr>\n<td>AI Resolution<\/td>\n<td>16-Bit<\/td>\n<td>18-Bit<\/td>\n<\/tr>\n<tr>\n<td>Maximum AI Rate<\/td>\n<td>250 kS\/s<\/td>\n<td>625 kS\/s<\/td>\n<\/tr>\n<tr>\n<td>Maximum AI Channels<\/td>\n<td>8<\/td>\n<td>16<\/td>\n<\/tr>\n<tr>\n<td>Analog Outputs<\/td>\n<td>4<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>\u0418\u0437\u043e\u043b\u044f\u0446\u0438\u044f<\/td>\n<td><strong>Bank Isolation<\/strong><\/td>\n<td>Nonisolated Architecture<\/td>\n<\/tr>\n<tr>\n<td>Best For<\/td>\n<td>Industrial \/ Isolated Measurements<\/td>\n<td>High-Accuracy General DAQ<\/td>\n<\/tr>\n<\/table>\n<p>\nChoose the PCI-6230 when isolation is a major system requirement. Choose a high-accuracy DAQ such as the PCI-6281 when higher analog resolution, higher sampling performance, or additional analog input channels are more important.\n<\/p>\n<h3>37-Pin D-SUB Connector<\/h3>\n<p>\nThe PCI-6230 uses a <strong>37-pin D-SUB I\/O connector<\/strong>.\n<\/p>\n<p>\nThe appropriate cable, terminal block, and connection accessories should be selected according to the required wiring architecture and application.\n<\/p>\n<p>\nBefore purchasing accessories, verify compatibility with the PCI-6230 model and required signal connections.\n<\/p>\n<h3>NI-DAQmx Integration<\/h3>\n<p>\nThe PCI-6230 uses <strong>\u041d\u0418-DAQmx<\/strong> for device configuration, data acquisition, signal generation, digital I\/O, counter\/timer operations, timing, and triggering.\n<\/p>\n<p>\nTypical NI-DAQmx functionality includes:\n<\/p>\n<ul>\n<li>Analog input configuration<\/li>\n<li>Analog output generation<\/li>\n<li>Digital input and output<\/li>\n<li>Counter\/timer configuration<\/li>\n<li>Hardware timing<\/li>\n<li>Trigger configuration<\/li>\n<li>Buffer management<\/li>\n<li>Device diagnostics<\/li>\n<\/ul>\n<h3>LabVIEW Integration<\/h3>\n<p>\nThe PCI-6230 can be integrated into LabVIEW applications through compatible NI-DAQmx software.\n<\/p>\n<p>\nA typical measurement application can follow this workflow:\n<\/p>\n<p>\n<strong>Configure Channels \u2192 Configure Timing \u2192 Configure Trigger \u2192 Start Task \u2192 Acquire \/ Generate Data \u2192 Analyze Results \u2192 Stop Task<\/strong>\n<\/p>\n<h3>Legacy System Maintenance<\/h3>\n<p>\nThe PCI-6230 is particularly relevant for existing industrial and automated test systems built around conventional PCI computers.\n<\/p>\n<p>\nWhen replacing an existing PCI-6230, engineers should verify:\n<\/p>\n<ul>\n<li>PCI slot compatibility<\/li>\n<li>NI-DAQmx version<\/li>\n<li>Operating system compatibility<\/li>\n<li>LabVIEW or application software version<\/li>\n<li>Existing cable compatibility<\/li>\n<li>Terminal block compatibility<\/li>\n<li>Analog input ranges<\/li>\n<li>Digital signal requirements<\/li>\n<li>Isolation requirements<\/li>\n<li>Existing application source code<\/li>\n<\/ul>\n<h3>How to Choose an Isolated Multifunction DAQ<\/h3>\n<p>\nBefore selecting the PCI-6230, evaluate:\n<\/p>\n<ul>\n<li>Required electrical isolation<\/li>\n<li>Analog input channel count<\/li>\n<li>Single-ended or differential configuration<\/li>\n<li>Required analog input resolution<\/li>\n<li>Sampling rate<\/li>\n<li>Input voltage range<\/li>\n<li>Analog output requirements<\/li>\n<li>Digital input requirements<\/li>\n<li>Digital output requirements<\/li>\n<li>Counter\/timer requirements<\/li>\n<li>PCI slot availability<\/li>\n<li>Connector and cable requirements<\/li>\n<li>NI-DAQmx compatibility<\/li>\n<li>Operating system compatibility<\/li>\n<\/ul>\n<h3>Industries<\/h3>\n<ul>\n<li>\u041f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u0430\u044f \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0437\u0430\u0446\u0438\u044f<\/li>\n<li>Automated Test<\/li>\n<li>Electronic Validation<\/li>\n<li>Manufacturing Test<\/li>\n<li>Machine Monitoring<\/li>\n<li>Power Electronics<\/li>\n<li>Motor and Drive Testing<\/li>\n<li>Laboratory Automation<\/li>\n<li>Research and Development<\/li>\n<li>Production Test<\/li>\n<\/ul>\n<h3>Applications<\/h3>\n<h4>Isolated Voltage Measurement<\/h4>\n<p>\nThe PCI-6230 can acquire compatible voltage signals in applications where bank isolation is required to improve measurement-system robustness.\n<\/p>\n<h4>Industrial Data Acquisition<\/h4>\n<p>\nIts isolated multifunction architecture makes the PCI-6230 suitable for acquiring and controlling signals from industrial equipment.\n<\/p>\n<h4>Automated Test<\/h4>\n<p>\nAnalog inputs, analog outputs, digital I\/O, counters, timing, and isolation can be combined in automated functional test and validation systems.\n<\/p>\n<h4>Machine Monitoring<\/h4>\n<p>\nThe PCI-6230 can monitor analog and digital signals from machines and production equipment in industrial environments.\n<\/p>\n<h4>Electronic Validation<\/h4>\n<p>\nThe device can generate test stimulus, acquire voltage measurements, control digital signals, and perform timing measurements during electronic validation.\n<\/p>\n<h4>Legacy Test System Replacement<\/h4>\n<p>\nThe PCI-6230 can be used to maintain compatible existing PCI-based measurement and control systems where the same hardware architecture must be retained.\n<\/p>\n<h3>Recommended Related Products<\/h3>\n<table>\n<tr>\n<td width=\"220\"><strong>PCI-6230<\/strong><\/td>\n<td>16-bit isolated multifunction PCI DAQ device with analog input, analog output, digital I\/O, and counters\/timers.<\/td>\n<\/tr>\n<tr>\n<td><strong>\u041f\u0425\u0418-6230<\/strong><\/td>\n<td>PXI version for modular systems requiring similar isolated multifunction DAQ capabilities.<\/td>\n<\/tr>\n<tr>\n<td><strong>PCI-6232<\/strong><\/td>\n<td>Isolated M Series DAQ option for related industrial measurement and control applications.<\/td>\n<\/tr>\n<tr>\n<td><strong>PCI-6233<\/strong><\/td>\n<td>Related isolated multifunction DAQ device for applications requiring a different I\/O configuration.<\/td>\n<\/tr>\n<tr>\n<td><strong>PCI-6281<\/strong><\/td>\n<td>18-bit high-accuracy multifunction PCI DAQ for applications prioritizing measurement resolution and higher analog acquisition performance.<\/td>\n<\/tr>\n<\/table>\n<h3>Why Choose PCI-6230?<\/h3>\n<ul>\n<li>8 single-ended analog inputs<\/li>\n<li>4 differential analog inputs<\/li>\n<li>16-bit analog input resolution<\/li>\n<li>Up to 250 kS\/s sampling<\/li>\n<li>4 \u0430\u043d\u0430\u043b\u043e\u0433\u043e\u0432\u044b\u0445 \u0432\u044b\u0445\u043e\u0434\u043d\u044b\u0445 \u043a\u0430\u043d\u0430\u043b\u0430<\/li>\n<li>6 digital input lines<\/li>\n<li>4 digital output lines<\/li>\n<li>5 V TTL\/CMOS digital interface<\/li>\n<li>Bank isolation<\/li>\n<li>Two 32-bit counters\/timers<\/li>\n<li>37-pin D-SUB connector<\/li>\n<li>PCI host interface<\/li>\n<li>NI-DAQmx support<\/li>\n<li>\u0418\u043d\u0442\u0435\u0433\u0440\u0430\u0446\u0438\u044f LabVIEW<\/li>\n<li>Suitable for industrial measurement<\/li>\n<li>Suitable for automated testing<\/li>\n<\/ul>\n<h3>Frequently Asked Questions<\/h3>\n<h4>What is the NI PCI-6230?<\/h4>\n<p>\nThe NI PCI-6230 is an isolated M Series multifunction PCI DAQ device providing analog input, analog output, digital I\/O, counters\/timers, and bank isolation for industrial measurement and automated test applications.\n<\/p>\n<h4>How many analog input channels does PCI-6230 have?<\/h4>\n<p>\nThe PCI-6230 provides up to <strong>8 single-ended or 4 differential analog input channels<\/strong>.\n<\/p>\n<h4>What is the analog input resolution of PCI-6230?<\/h4>\n<p>\nThe PCI-6230 provides <strong>16-bit analog input resolution<\/strong>.\n<\/p>\n<h4>What is the maximum sample rate of PCI-6230?<\/h4>\n<p>\nThe maximum single-channel analog input sampling rate is <strong>250 kS\/s<\/strong>.\n<\/p>\n<h4>What analog input ranges does PCI-6230 support?<\/h4>\n<p>\nThe PCI-6230 supports programmable analog input ranges of <strong>\u00b10.2 V, \u00b11 V, \u00b15 V, and \u00b110 V<\/strong>.\n<\/p>\n<h4>Does PCI-6230 have analog outputs?<\/h4>\n<p>\nYes. The PCI-6230 provides <strong>4 \u0430\u043d\u0430\u043b\u043e\u0433\u043e\u0432\u044b\u0445 \u0432\u044b\u0445\u043e\u0434\u043d\u044b\u0445 \u043a\u0430\u043d\u0430\u043b\u0430<\/strong> for programmable voltage generation and control applications.\n<\/p>\n<h4>Does PCI-6230 have digital I\/O?<\/h4>\n<p>\nYes. The PCI-6230 provides <strong>6 digital input lines and 4 digital output lines<\/strong>.\n<\/p>\n<h4>Is the PCI-6230 isolated?<\/h4>\n<p>\nYes. The PCI-6230 provides <strong>bank isolation<\/strong>, which is one of the primary reasons to select this model for industrial measurement and control applications.\n<\/p>\n<h4>How many counters does PCI-6230 have?<\/h4>\n<p>\nThe PCI-6230 provides <strong>two 32-bit counters\/timers<\/strong>.\n<\/p>\n<h4>What connector does PCI-6230 use?<\/h4>\n<p>\nThe PCI-6230 uses a <strong>37-pin D-SUB I\/O connector<\/strong>.\n<\/p>\n<h4>What driver does PCI-6230 use?<\/h4>\n<p>\nThe PCI-6230 uses the <strong>\u041d\u0418-DAQmx<\/strong> driver architecture for configuration, measurement, signal generation, digital I\/O, timing, and counter operations.\n<\/p>\n<h4>Can PCI-6230 be used with LabVIEW?<\/h4>\n<p>\nYes. PCI-6230 can be integrated into LabVIEW-based measurement, industrial monitoring, control, and automated test applications through compatible NI-DAQmx software.\n<\/p>\n<h4>What is the difference between PCI-6230 and PXI-6230?<\/h4>\n<p>\nThe primary difference is the system platform. PCI-6230 installs in a conventional PCI computer, while PXI-6230 installs in a PXI chassis. Both belong to the NI 6230 isolated multifunction DAQ family.\n<\/p>\n<h4>What is the difference between PCI-6230 and PCI-6281?<\/h4>\n<p>\nPCI-6230 is designed around isolated multifunction I\/O and provides bank isolation, while PCI-6281 focuses on high-accuracy multifunction acquisition with 18-bit analog input resolution and higher acquisition performance. The appropriate model depends on whether isolation or higher measurement resolution and channel count are more important.\n<\/p>\n<h4>Is PCI-6230 suitable for industrial environments?<\/h4>\n<p>\nYes. Its bank-isolated architecture makes it particularly useful for industrial measurement, machine monitoring, automated testing, and other applications where ground-potential differences or electrical noise may be present.\n<\/p>\n<h4>Can PCI-6230 directly measure industrial high-voltage signals?<\/h4>\n<p>\nThe PCI-6230 should only be used within its specified input, working-voltage, and isolation limits. Higher-voltage signals require appropriate attenuation, isolation, or signal-conditioning hardware. Always verify the official device specifications before connecting industrial power signals.\n<\/p>\n<h4>Is the NI PCI-6230 discontinued?<\/h4>\n<p>\nNI currently identifies the PCI-6230 as <strong>no longer available<\/strong>. It remains relevant for maintenance, repair, replacement, and expansion of existing PCI-based measurement systems.\n<\/p>\n<h4>What should I check before purchasing a PCI-6230 replacement?<\/h4>\n<p>\nVerify the PCI interface, analog input and output requirements, 37-pin D-SUB connector and accessories, digital I\/O configuration, isolation requirements, existing cabling, NI-DAQmx version, operating system, LabVIEW version, and compatibility with the original application.\n<\/p>\n<h3>\u0417\u0430\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435<\/h3>\n<p>\n\u0417\u0435\u043c\u043b\u044f <strong>NI PCI-6230 Isolated Multifunction DAQ<\/strong> combines 16-bit, 250 kS\/s analog acquisition with up to 8 single-ended or 4 differential analog inputs, four analog outputs, six digital inputs, four digital outputs, two 32-bit counters\/timers, and bank isolation. Its isolated multifunction architecture makes it particularly suitable for industrial measurement, machine monitoring, automated test, electronic validation, production systems, and maintenance of legacy PCI-based NI DAQ installations.<\/p>","protected":false},"excerpt":{"rendered":"<p>\u041a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u0434\u0432\u0443\u043d\u0430\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u043d\u044b\u0445 \u0446\u0438\u0444\u0440\u043e\u0432\u044b\u0445 \u043a\u0430\u043d\u0430\u043b\u043e\u0432: 0<br \/>\n\u041c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u0435 \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u043e\u0434\u043d\u043e\u043f\u043e\u043b\u044f\u0440\u043d\u044b\u0445 \u0430\u043d\u0430\u043b\u043e\u0433\u043e\u0432\u044b\u0445 \u0432\u0445\u043e\u0434\u043d\u044b\u0445 \u043a\u0430\u043d\u0430\u043b\u043e\u0432: 8<br \/>\nNumber of Counters\/Timers: 2<br \/>\n\u041c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u0435 \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u0434\u0438\u0444\u0444\u0435\u0440\u0435\u043d\u0446\u0438\u0430\u043b\u044c\u043d\u044b\u0445 \u0430\u043d\u0430\u043b\u043e\u0433\u043e\u0432\u044b\u0445 \u0432\u0445\u043e\u0434\u043d\u044b\u0445 \u043a\u0430\u043d\u0430\u043b\u043e\u0432: 4<br \/>\nAnalog Input Absolute Accuracy: 3100 \u03bcV<br \/>\nAnalog Input FIFO Buffer Size 4095 samples<br \/>\n\u041c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u0430\u044f \u0447\u0430\u0441\u0442\u043e\u0442\u0430 \u0434\u0438\u0441\u043a\u0440\u0435\u0442\u0438\u0437\u0430\u0446\u0438\u0438: 250 \u043a\u0412\u044b\u0431\/\u0441<br \/>\n\u041e\u0434\u043d\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u0430\u044f \u0432\u044b\u0431\u043e\u0440\u043a\u0430: \u041d\u0435\u0442<br \/>\n\u0412 \u043a\u043e\u043c\u043f\u043b\u0435\u043a\u0442 \u0432\u0445\u043e\u0434\u0438\u0442: \u0414\u0430<br \/>\n\u0420\u0430\u0437\u0440\u0435\u0448\u0435\u043d\u0438\u0435 \u0430\u043d\u0430\u043b\u043e\u0433\u043e\u0432\u043e\u0433\u043e \u0432\u0445\u043e\u0434\u0430: 16 \u0431\u0438\u0442<br \/>\nBus Connector: PCI<br \/>\nFront Connection Type: D-SUB(1)<br \/>\n\u041a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u0430\u043d\u0430\u043b\u043e\u0433\u043e\u0432\u044b\u0445 \u0432\u044b\u0445\u043e\u0434\u043d\u044b\u0445 \u043a\u0430\u043d\u0430\u043b\u043e\u0432: 4<br \/>\nMaximum Analog Update Rate: 500 kS\/s<br \/>\nBus Connection: PCI<\/p>","protected":false},"featured_media":31103,"template":"","meta":{"_acf_changed":false},"product_brand":[18],"product_cat":[674],"product_tag":[],"class_list":["post-34646","product","type-product","status-publish","has-post-thumbnail","product_brand-national-instruments","product_cat-pci-usb","first","instock","shipping-taxable","product-type-simple"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.0 (Yoast SEO v28.1) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>NI PCI-6230 PCI Multifunction I\/O Device 779615-01, In Stock | Project Pricing<\/title>\n<meta name=\"description\" content=\"NI PCI-6230 is a 16-bit, 250 kS\/s isolated PCI multifunction DAQ with 8 analog inputs, 4 analog outputs, digital I\/O and two 32-bit counters\/timers.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/pxisource.com\/ru\/product\/pci-6230\/\" \/>\n<meta property=\"og:locale\" content=\"ru_RU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"PCI-6230\" \/>\n<meta property=\"og:description\" content=\"NI PCI-6230 is a 16-bit, 250 kS\/s isolated PCI multifunction DAQ with 8 analog inputs, 4 analog outputs, digital I\/O and two 32-bit counters\/timers.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/pxisource.com\/ru\/product\/pci-6230\/\" \/>\n<meta property=\"og:site_name\" content=\"PXI Source\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=61582573040385\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-27T06:13:54+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PCI-6230.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"800\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u0426\u0435\u043d\u0430\" \/>\n\t<meta name=\"twitter:data1\" content=\"\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c\" \/>\n\t<meta name=\"twitter:data2\" content=\"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pci-6230\\\/\",\"url\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pci-6230\\\/\",\"name\":\"NI PCI-6230 PCI Multifunction I\\\/O Device 779615-01, In Stock | Project Pricing\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pci-6230\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pci-6230\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/PCI-6230.webp\",\"datePublished\":\"2026-08-07T05:22:09+00:00\",\"dateModified\":\"2026-08-27T06:13:54+00:00\",\"description\":\"NI PCI-6230 is a 16-bit, 250 kS\\\/s isolated PCI multifunction DAQ with 8 analog inputs, 4 analog outputs, digital I\\\/O and two 32-bit counters\\\/timers.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pci-6230\\\/#breadcrumb\"},\"inLanguage\":\"ru-RU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/pxisource.com\\\/product\\\/pci-6230\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pci-6230\\\/#primaryimage\",\"url\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/PCI-6230.webp\",\"contentUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/PCI-6230.webp\",\"width\":800,\"height\":800,\"caption\":\"PCI-6230\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pci-6230\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/pxisource.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u5546\u5e97\",\"item\":\"https:\\\/\\\/pxisource.com\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"PCI-6230\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\",\"url\":\"https:\\\/\\\/pxisource.com\\\/\",\"name\":\"PXI Systems\",\"description\":\"PXI, PXIe and Modular Test Equipment\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/pxisource.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ru-RU\"}]}<\/script>\n<meta property=\"product:brand\" content=\"National Instruments\" \/>\n<meta property=\"product:price:currency\" content=\"USD\" \/>\n<meta property=\"og:availability\" content=\"instock\" \/>\n<meta property=\"product:availability\" content=\"instock\" \/>\n<meta property=\"product:condition\" content=\"new\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"NI PCI-6230 PCI Multifunction I\/O Device 779615-01, In Stock | Project Pricing","description":"NI PCI-6230 is a 16-bit, 250 kS\/s isolated PCI multifunction DAQ with 8 analog inputs, 4 analog outputs, digital I\/O and two 32-bit counters\/timers.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/pxisource.com\/ru\/product\/pci-6230\/","og_locale":"ru_RU","og_type":"article","og_title":"PCI-6230","og_description":"NI PCI-6230 is a 16-bit, 250 kS\/s isolated PCI multifunction DAQ with 8 analog inputs, 4 analog outputs, digital I\/O and two 32-bit counters\/timers.","og_url":"https:\/\/pxisource.com\/ru\/product\/pci-6230\/","og_site_name":"PXI Source","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=61582573040385","article_modified_time":"2026-08-27T06:13:54+00:00","og_image":[{"width":800,"height":800,"url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PCI-6230.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"\u0426\u0435\u043d\u0430":"","\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c":"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/pxisource.com\/product\/pci-6230\/","url":"https:\/\/pxisource.com\/product\/pci-6230\/","name":"NI PCI-6230 PCI Multifunction I\/O Device 779615-01, In Stock | Project Pricing","isPartOf":{"@id":"https:\/\/pxisource.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/pxisource.com\/product\/pci-6230\/#primaryimage"},"image":{"@id":"https:\/\/pxisource.com\/product\/pci-6230\/#primaryimage"},"thumbnailUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PCI-6230.webp","datePublished":"2026-08-07T05:22:09+00:00","dateModified":"2026-08-27T06:13:54+00:00","description":"NI PCI-6230 is a 16-bit, 250 kS\/s isolated PCI multifunction DAQ with 8 analog inputs, 4 analog outputs, digital I\/O and two 32-bit counters\/timers.","breadcrumb":{"@id":"https:\/\/pxisource.com\/product\/pci-6230\/#breadcrumb"},"inLanguage":"ru-RU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/pxisource.com\/product\/pci-6230\/"]}]},{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/pxisource.com\/product\/pci-6230\/#primaryimage","url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PCI-6230.webp","contentUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PCI-6230.webp","width":800,"height":800,"caption":"PCI-6230"},{"@type":"BreadcrumbList","@id":"https:\/\/pxisource.com\/product\/pci-6230\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/pxisource.com\/"},{"@type":"ListItem","position":2,"name":"\u5546\u5e97","item":"https:\/\/pxisource.com\/shop\/"},{"@type":"ListItem","position":3,"name":"PCI-6230"}]},{"@type":"WebSite","@id":"https:\/\/pxisource.com\/#website","url":"https:\/\/pxisource.com\/","name":"\u0421\u0438\u0441\u0442\u0435\u043c\u044b PXI","description":"PXI, PXIe and Modular Test Equipment","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/pxisource.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ru-RU"}]},"product_brand":"National Instruments","product_price_currency":"USD","og_availability":"instock","product_availability":"instock","product_condition":"new"},"_links":{"self":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/34646","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":3,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/34646\/revisions"}],"predecessor-version":[{"id":35478,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/34646\/revisions\/35478"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media\/31103"}],"wp:attachment":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media?parent=34646"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_brand?post=34646"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_cat?post=34646"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_tag?post=34646"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}