{"id":34529,"date":"2026-08-07T12:29:04","date_gmt":"2026-08-07T04:29:04","guid":{"rendered":"https:\/\/pxisource.com\/?post_type=product&#038;p=34529"},"modified":"2026-08-27T18:29:25","modified_gmt":"2026-08-27T10:29:25","slug":"pcie-6612","status":"publish","type":"product","link":"https:\/\/pxisource.com\/ru\/product\/pcie-6612\/","title":{"rendered":"PCIe-6612"},"content":{"rendered":"<h3>Product Introduction<\/h3>\n<p>\n\u0417\u0435\u043c\u043b\u044f <strong>NI PCIe-6612<\/strong> \u0432\u044b\u0441\u043e\u043a\u043e\u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c\u043d\u044b\u0439 <strong>PCI Express counter\/timer and digital I\/O device<\/strong> designed for encoder measurement, event counting, frequency measurement, period measurement, pulse-width measurement, pulse generation, and hardware-timed digital applications.\n<\/p>\n<p>\nThe PCIe-6612 provides <strong>8 counter\/timers<\/strong> together with <strong>40 bidirectional digital I\/O lines<\/strong>. Its counter architecture supports applications ranging from basic event counting to sophisticated encoder position measurement and hardware-timed pulse generation.\n<\/p>\n<p>\nWith frequency measurement capability up to <strong>80 MHz<\/strong>, TTL\/CMOS-compatible 5 V digital I\/O, programmable digital filters, waveform digital I\/O, and multiple DMA channels, the PCIe-6612 is well suited for motion measurement, automated test, industrial timing, encoder acquisition, pulse measurement, frequency analysis, and digital control applications.\n<\/p>\n<h3>Product Overview<\/h3>\n<p>\n\u0417\u0435\u043c\u043b\u044f <strong>National Instruments PCIe-6612<\/strong> is a dedicated counter\/timer device for PCI Express-based computers.\n<\/p>\n<p>\nA typical measurement architecture is:\n<\/p>\n<p>\n<strong>Encoder \/ Pulse \/ Frequency Signal \u2192 PCIe-6612 \u2192 PCI Express \u2192 Host Computer \u2192 NI-DAQmx \/ LabVIEW<\/strong>\n<\/p>\n<p>\nFor generation applications:\n<\/p>\n<p>\n<strong>Host Application \u2192 PCIe-6612 Counter\/Timer \u2192 Pulse \/ Pulse Train \u2192 Device Under Test<\/strong>\n<\/p>\n<p>\nThis combination of measurement and generation makes the PCIe-6612 more flexible than a conventional basic digital I\/O card.\n<\/p>\n<h3>Key Features<\/h3>\n<h4>8 Counter\/Timer Channels<\/h4>\n<p>\nThe PCIe-6612 provides <strong>8 independent counter\/timer resources<\/strong> for hardware-timed measurement and generation applications.\n<\/p>\n<p>\nTypical counter functions include:\n<\/p>\n<ul>\n<li>\u041f\u043e\u0434\u0441\u0447\u0435\u0442 \u0441\u043e\u0431\u044b\u0442\u0438\u0439<\/li>\n<li>Frequency measurement<\/li>\n<li>Period measurement<\/li>\n<li>Pulse-width measurement<\/li>\n<li>Encoder position measurement<\/li>\n<li>\u0413\u0435\u043d\u0435\u0440\u0430\u0446\u0438\u044f \u0438\u043c\u043f\u0443\u043b\u044c\u0441\u043e\u0432<\/li>\n<li>Pulse-train generation<\/li>\n<li>Digital timing<\/li>\n<\/ul>\n<h4>Up to 80 MHz Frequency Measurement<\/h4>\n<p>\nThe PCIe-6612 supports frequency measurement from approximately <strong>0 MHz to 80 MHz<\/strong>.\n<\/p>\n<p>\nThis high-frequency measurement capability makes the device useful for applications involving fast pulse trains, frequency outputs, digital sensors, rotational speed measurements, and high-speed timing signals.\n<\/p>\n<h4>Encoder Position Measurement<\/h4>\n<p>\nThe PCIe-6612 can be used for <strong>encoder position measurement<\/strong>.\n<\/p>\n<p>\nCompatible encoder applications can include:\n<\/p>\n<ul>\n<li>Motor shaft position<\/li>\n<li>Rotary encoder measurement<\/li>\n<li>Linear position measurement<\/li>\n<li>Machine-axis monitoring<\/li>\n<li>Motion-system feedback<\/li>\n<li>Test stand position acquisition<\/li>\n<\/ul>\n<h4>Event Counting<\/h4>\n<p>\nThe counter\/timers can count external digital events or pulses.\n<\/p>\n<p>\nTypical event-counting applications include:\n<\/p>\n<ul>\n<li>Production counting<\/li>\n<li>Sensor pulse counting<\/li>\n<li>Rotational event counting<\/li>\n<li>Machine cycle counting<\/li>\n<li>Photon or detector pulse counting<\/li>\n<li>Digital event monitoring<\/li>\n<\/ul>\n<h4>Period Measurement<\/h4>\n<p>\nThe PCIe-6612 can measure the period of incoming digital signals.\n<\/p>\n<p>\nPeriod measurement is useful when characterizing repetitive signals or calculating frequency from timing information.\n<\/p>\n<h4>Pulse-Width Measurement<\/h4>\n<p>\nThe device can measure the high or low duration of digital pulses.\n<\/p>\n<p>\n\u041e\u0431\u043b\u0430\u0441\u0442\u0438 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f \u0432\u043a\u043b\u044e\u0447\u0430\u044e\u0442:\n<\/p>\n<ul>\n<li>PWM characterization<\/li>\n<li>Sensor pulse measurement<\/li>\n<li>Digital timing verification<\/li>\n<li>Electronic device testing<\/li>\n<li>Pulse-width validation<\/li>\n<\/ul>\n<h4>Pulse Generation<\/h4>\n<p>\nThe PCIe-6612 counters can generate programmable output pulses for stimulus, timing, triggering, and control applications.\n<\/p>\n<p>\nPulse-generation applications include:\n<\/p>\n<ul>\n<li>External triggering<\/li>\n<li>Device stimulus<\/li>\n<li>Timing reference generation<\/li>\n<li>Equipment synchronization<\/li>\n<li>Automated test control<\/li>\n<\/ul>\n<h4>Pulse-Train Generation<\/h4>\n<p>\nThe PCIe-6612 can generate continuous or finite pulse trains according to the supported NI-DAQmx timing configuration.\n<\/p>\n<p>\nPulse trains can be used for:\n<\/p>\n<ul>\n<li>Stepper motor control signals<\/li>\n<li>Clock generation<\/li>\n<li>Frequency stimulus<\/li>\n<li>Digital timing references<\/li>\n<li>Test equipment synchronization<\/li>\n<\/ul>\n<h4>40 Bidirectional Digital I\/O Channels<\/h4>\n<p>\nThe PCIe-6612 provides <strong>40 total bidirectional digital channels<\/strong>.\n<\/p>\n<p>\nNI identifies these channels as:\n<\/p>\n<ul>\n<li>Port 0: P0.0 through P0.31<\/li>\n<li>Port 1: P1.0 through P1.7<\/li>\n<li>PFI 0 through PFI 39<\/li>\n<\/ul>\n<p>\nEach terminal can be programmed individually as a digital input or digital output.\n<\/p>\n<h4>5 V TTL\/CMOS-Compatible Digital I\/O<\/h4>\n<p>\nThe PCIe-6612 provides <strong>5 V TTL\/CMOS-compatible digital I\/O<\/strong>.\n<\/p>\n<p>\nThis makes the device suitable for interfacing with many digital logic circuits, encoders, pulse-output sensors, electronic test devices, and timing systems.\n<\/p>\n<h4>Programmable Digital Debouncing Filters<\/h4>\n<p>\nThe PCIe-6612 includes programmable digital filtering to help reject unwanted transitions and switch bounce on digital input signals.\n<\/p>\n<p>\nNI specifies filter settings including:\n<\/p>\n<ul>\n<li>160 ns<\/li>\n<li>10.24 \u00b5s<\/li>\n<li>5.12 ms<\/li>\n<li>Filter disabled<\/li>\n<\/ul>\n<p>\nDigital filtering can be especially useful with mechanical switches, encoders, sensors, and electrically noisy pulse signals.\n<\/p>\n<h4>Three Simultaneous High-Speed DMA Transfers<\/h4>\n<p>\nThe PCIe-6612 supports <strong>three simultaneous high-speed DMA transfers<\/strong>.\n<\/p>\n<p>\nDMA allows hardware data to be transferred to and from system memory with reduced processor involvement, improving performance in hardware-timed measurement and generation applications.\n<\/p>\n<h4>Waveform Digital I\/O<\/h4>\n<p>\nPort 0 supports hardware-timed waveform digital I\/O for applications requiring synchronized digital acquisition or generation.\n<\/p>\n<p>\nThe waveform DIO architecture supports up to <strong>32-bit digital samples<\/strong>.\n<\/p>\n<h4>Up to 10 MHz Digital Waveform Timing<\/h4>\n<p>\nThe PCIe-6612 supports digital waveform input and output sample clocks up to approximately <strong>10 MHz<\/strong>, depending on system and bus activity.\n<\/p>\n<p>\nThis capability is useful when digital patterns must be acquired or generated under hardware timing.\n<\/p>\n<h3>Technical Specifications<\/h3>\n<table>\n<tr>\n<th>\u041f\u0430\u0440\u0430\u043c\u0435\u0442\u0440<\/th>\n<th>\u0421\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f<\/th>\n<\/tr>\n<tr>\n<td width=\"280\">Product Type<\/td>\n<td>\u0421\u0447\u0435\u0442\u0447\u0438\u043a\/\u0422\u0430\u0439\u043c\u0435\u0440<\/td>\n<\/tr>\n<tr>\n<td>\u041c\u043e\u0434\u0435\u043b\u044c<\/td>\n<td>PCIe-6612<\/td>\n<\/tr>\n<tr>\n<td>Part Number<\/td>\n<td>782351-01<\/td>\n<\/tr>\n<tr>\n<td>Manufacturer<\/td>\n<td>\u041d\u0430\u0446\u0438\u043e\u043d\u0430\u043b\u044c\u043d\u044b\u0435 \u0438\u043d\u0441\u0442\u0440\u0443\u043c\u0435\u043d\u0442\u044b<\/td>\n<\/tr>\n<tr>\n<td>\u0428\u0438\u043d\u043d\u044b\u0439 \u0438\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441<\/td>\n<td>PCI Express<\/td>\n<\/tr>\n<tr>\n<td>Number of Counters\/Timers<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<td>Frequency Measurement Range<\/td>\n<td>0 MHz to 80 MHz<\/td>\n<\/tr>\n<tr>\n<td>Bidirectional Digital Channels<\/td>\n<td>40<\/td>\n<\/tr>\n<tr>\n<td>Digital I\/O Logic<\/td>\n<td>5 V TTL\/CMOS Compatible<\/td>\n<\/tr>\n<tr>\n<td>Digital Channel Direction<\/td>\n<td>Individually Programmable Input or Output<\/td>\n<\/tr>\n<tr>\n<td>Digital Input Protection<\/td>\n<td>-3 V to +8 V<\/td>\n<\/tr>\n<tr>\n<td>Digital Pull-Down Resistor<\/td>\n<td>51 k\u03a9<\/td>\n<\/tr>\n<tr>\n<td>Digital Output Impedance<\/td>\n<td>75 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>Waveform Digital I\/O<\/td>\n<td>Port 0, Up to 32 Bits<\/td>\n<\/tr>\n<tr>\n<td>Maximum DI Sample Clock<\/td>\n<td>Up to 10 MHz<\/td>\n<\/tr>\n<tr>\n<td>Maximum DO Sample Clock<\/td>\n<td>Up to 10 MHz<\/td>\n<\/tr>\n<tr>\n<td>Digital Filter Settings<\/td>\n<td>160 ns \/ 10.24 \u00b5s \/ 5.12 ms \/ Disabled<\/td>\n<\/tr>\n<tr>\n<td>DMA<\/td>\n<td>3 Simultaneous High-Speed DMA Transfers<\/td>\n<\/tr>\n<tr>\n<td>Driver<\/td>\n<td>\u041d\u0418-DAQmx<\/td>\n<\/tr>\n<tr>\n<td>Product Status<\/td>\n<td>Active<\/td>\n<\/tr>\n<tr>\n<td>Primary Applications<\/td>\n<td>Encoder Measurement, Frequency Measurement, Event Counting, Pulse Measurement and Generation<\/td>\n<\/tr>\n<\/table>\n<h3>How Does the PCIe-6612 Work?<\/h3>\n<p>\nThe PCIe-6612 detects the timing and state transitions of external digital signals using dedicated hardware counter\/timer resources.\n<\/p>\n<p>\nFor measurement:\n<\/p>\n<p>\n<strong>Encoder \/ Pulse Signal \u2192 Digital Input \u2192 Counter\/Timer \u2192 PCI Express \u2192 Host Application<\/strong>\n<\/p>\n<p>\nFor generation:\n<\/p>\n<p>\n<strong>Host Configuration \u2192 Counter\/Timer \u2192 Hardware-Timed Pulse Output \u2192 External Device<\/strong>\n<\/p>\n<p>\nBecause critical timing operations occur in dedicated hardware, counter measurements can provide much more deterministic performance than software-based timing loops.\n<\/p>\n<h3>What Is a Counter\/Timer Device?<\/h3>\n<p>\nA counter\/timer device measures or generates digital events based on precise hardware timing.\n<\/p>\n<p>\nInstead of simply reading a HIGH or LOW state, a counter can evaluate the timing relationship between signal transitions.\n<\/p>\n<p>\nThis enables measurements such as:\n<\/p>\n<ul>\n<li>How many pulses occurred?<\/li>\n<li>How fast are pulses arriving?<\/li>\n<li>How long is each pulse?<\/li>\n<li>What is the period of a signal?<\/li>\n<li>What is the position of an encoder?<\/li>\n<li>What pulse frequency should be generated?<\/li>\n<\/ul>\n<h3>Encoder Measurement<\/h3>\n<p>\nEncoder measurement is one of the primary applications of the PCIe-6612.\n<\/p>\n<p>\nA typical system is:\n<\/p>\n<p>\n<strong>Rotary Encoder \u2192 A\/B\/Z Signals \u2192 PCIe-6612 \u2192 Position \/ Direction \/ Speed Measurement<\/strong>\n<\/p>\n<p>\nDepending on the encoder and measurement configuration, the counter\/timer hardware can track position and motion information with hardware-based timing.\n<\/p>\n<h3>Quadrature Encoder Applications<\/h3>\n<p>\nQuadrature encoders commonly provide A and B signals that are phase shifted relative to one another.\n<\/p>\n<p>\nThe direction of movement can be determined from the phase relationship between the two signals, while pulse counting determines the position change.\n<\/p>\n<p>\n\u041e\u0431\u043b\u0430\u0441\u0442\u0438 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f \u0432\u043a\u043b\u044e\u0447\u0430\u044e\u0442:\n<\/p>\n<ul>\n<li>Motor position measurement<\/li>\n<li>Machine-axis monitoring<\/li>\n<li>Robot joint measurement<\/li>\n<li>Linear stage measurement<\/li>\n<li>Rotational test systems<\/li>\n<\/ul>\n<h3>Frequency Measurement<\/h3>\n<p>\nThe PCIe-6612 can measure incoming signal frequency up to <strong>80 MHz<\/strong>.\n<\/p>\n<p>\nTypical frequency sources include:\n<\/p>\n<ul>\n<li>Pulse-output sensors<\/li>\n<li>Oscillator signals<\/li>\n<li>Encoder outputs<\/li>\n<li>Tachometer signals<\/li>\n<li>Electronic circuits<\/li>\n<li>Digital clock sources<\/li>\n<\/ul>\n<h3>Rotational Speed Measurement<\/h3>\n<p>\nRotational speed can be calculated from pulses generated by an encoder, tachometer, or other rotational sensor.\n<\/p>\n<p>\nA typical measurement chain is:\n<\/p>\n<p>\n<strong>Rotating Shaft \u2192 Encoder \/ Tachometer \u2192 PCIe-6612 \u2192 Frequency \/ Pulse Count \u2192 RPM<\/strong>\n<\/p>\n<p>\nThe conversion between frequency and RPM depends on the number of pulses generated per revolution.\n<\/p>\n<h3>Event Counting<\/h3>\n<p>\nThe PCIe-6612 can count external events represented by digital pulses.\n<\/p>\n<p>\n\u041d\u0430\u043f\u0440\u0438\u043c\u0435\u0440:\n<\/p>\n<p>\n<strong>Photoelectric Sensor \u2192 Product Passes Sensor \u2192 Pulse \u2192 PCIe-6612 Counter \u2192 Production Count<\/strong>\n<\/p>\n<p>\nThis can be used in industrial, laboratory, manufacturing, and scientific measurement applications.\n<\/p>\n<h3>Pulse-Width Measurement<\/h3>\n<p>\nPulse-width measurement determines how long a digital signal remains in a particular state.\n<\/p>\n<p>\nThis capability is useful for:\n<\/p>\n<ul>\n<li>PWM duty-cycle analysis<\/li>\n<li>Digital control signal validation<\/li>\n<li>Sensor pulse characterization<\/li>\n<li>Electronic device testing<\/li>\n<li>Timing verification<\/li>\n<\/ul>\n<h3>Period Measurement<\/h3>\n<p>\nPeriod measurement determines the elapsed time between repetitive signal events.\n<\/p>\n<p>\nBecause frequency is the reciprocal of period, period measurement can also be useful for accurately measuring lower-frequency signals.\n<\/p>\n<h3>Pulse Generation<\/h3>\n<p>\nThe PCIe-6612 can generate hardware-timed digital pulses with programmable timing characteristics.\n<\/p>\n<p>\nPossible applications include:\n<\/p>\n<ul>\n<li>Trigger generation<\/li>\n<li>Clock generation<\/li>\n<li>Device stimulus<\/li>\n<li>Test sequence timing<\/li>\n<li>Equipment synchronization<\/li>\n<\/ul>\n<h3>PWM Generation<\/h3>\n<p>\nProgrammable counter outputs can be configured to generate pulse signals suitable for compatible PWM-type applications.\n<\/p>\n<p>\nThe resulting output can be used as a timing or control signal where the electrical requirements match the 5 V digital output capabilities of the PCIe-6612.\n<\/p>\n<h3>Stepper Motor Pulse Generation<\/h3>\n<p>\nIn compatible systems, counter\/timer pulse generation can be used to create step or clock signals for an external stepper motor driver.\n<\/p>\n<p>\nA simplified architecture is:\n<\/p>\n<p>\n<strong>PCIe-6612 Pulse Output \u2192 Stepper Driver \u2192 Motor<\/strong>\n<\/p>\n<p>\nThe PCIe-6612 should control the appropriate external driver rather than directly driving the motor power circuitry.\n<\/p>\n<h3>Digital Debouncing<\/h3>\n<p>\nMechanical switches and some sensors can produce multiple electrical transitions when changing state.\n<\/p>\n<p>\nWithout filtering, these unwanted transitions can be interpreted as additional events.\n<\/p>\n<p>\nThe programmable digital filters of the PCIe-6612 can help reject these short unwanted transitions before they reach the measurement logic.\n<\/p>\n<h3>Hardware-Timed Digital I\/O<\/h3>\n<p>\nThe PCIe-6612 provides more than static digital I\/O. Port 0 supports waveform-based digital acquisition and generation.\n<\/p>\n<p>\nThis allows engineers to acquire or output digital patterns under hardware-clock control rather than changing lines individually using software timing.\n<\/p>\n<h3>40 Digital I\/O Channels<\/h3>\n<p>\nThe device provides 40 bidirectional digital channels, giving the PCIe-6612 substantial general-purpose digital interfacing capability in addition to its counter\/timer functions.\n<\/p>\n<p>\nThese channels can support:\n<\/p>\n<ul>\n<li>Trigger inputs<\/li>\n<li>Trigger outputs<\/li>\n<li>Digital control<\/li>\n<li>Status monitoring<\/li>\n<li>Counter signal routing<\/li>\n<li>Hardware timing signals<\/li>\n<li>Digital pattern acquisition<\/li>\n<li>Digital pattern generation<\/li>\n<\/ul>\n<h3>PCIe-6612 vs PXIe-6612<\/h3>\n<p>\nThe PCIe-6612 and PXIe-6612 provide closely related counter\/timer capabilities but use different host platforms.\n<\/p>\n<table>\n<tr>\n<th>\u0424\u0443\u043d\u043a\u0446\u0438\u044f<\/th>\n<th>PCIe-6612<\/th>\n<th>PXIe-6612<\/th>\n<\/tr>\n<tr>\n<td>Platform<\/td>\n<td><strong>PCI Express<\/strong><\/td>\n<td>PXI Express<\/td>\n<\/tr>\n<tr>\n<td>Counter\/Timers<\/td>\n<td>8<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<td>\u0426\u0438\u0444\u0440\u043e\u0432\u043e\u0439 \u0432\u0432\u043e\u0434-\u0432\u044b\u0432\u043e\u0434<\/td>\n<td>40<\/td>\n<td>40<\/td>\n<\/tr>\n<tr>\n<td>Logic Level<\/td>\n<td>5 V TTL<\/td>\n<td>5 V TTL<\/td>\n<\/tr>\n<tr>\n<td>Maximum Frequency Measurement<\/td>\n<td>80 MHz<\/td>\n<td>80 MHz<\/td>\n<\/tr>\n<tr>\n<td>Host Installation<\/td>\n<td>Desktop \/ Industrial PC<\/td>\n<td>\u0428\u0430\u0441\u0441\u0438 PXI Express<\/td>\n<\/tr>\n<tr>\n<td>Part Number<\/td>\n<td>782351-01<\/td>\n<td>782352-01<\/td>\n<\/tr>\n<tr>\n<td>Best Application<\/td>\n<td>PC-Based Counter\/Timer Systems<\/td>\n<td>Modular PXIe Test Systems<\/td>\n<\/tr>\n<\/table>\n<h3>PCIe-6612 vs Multifunction DAQ<\/h3>\n<table>\n<tr>\n<th>\u0424\u0443\u043d\u043a\u0446\u0438\u044f<\/th>\n<th>PCIe-6612<\/th>\n<th>Typical Multifunction DAQ<\/th>\n<\/tr>\n<tr>\n<td>Primary Function<\/td>\n<td><strong>Counter \/ Timer<\/strong><\/td>\n<td>Analog Measurement<\/td>\n<\/tr>\n<tr>\n<td>Counter\/Timers<\/td>\n<td><strong>8<\/strong><\/td>\n<td>Typically Fewer<\/td>\n<\/tr>\n<tr>\n<td>Frequency Measurement<\/td>\n<td><strong>Up to 80 MHz<\/strong><\/td>\n<td>Device Dependent<\/td>\n<\/tr>\n<tr>\n<td>Encoder Measurement<\/td>\n<td><strong>Primary Application<\/strong><\/td>\n<td>Model Dependent<\/td>\n<\/tr>\n<tr>\n<td>\u0426\u0438\u0444\u0440\u043e\u0432\u043e\u0439 \u0432\u0432\u043e\u0434-\u0432\u044b\u0432\u043e\u0434<\/td>\n<td>40<\/td>\n<td>Model Dependent<\/td>\n<\/tr>\n<tr>\n<td>Analog Input<\/td>\n<td>No<\/td>\n<td><strong>Typically Yes<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Analog Output<\/td>\n<td>No<\/td>\n<td>Model Dependent<\/td>\n<\/tr>\n<tr>\n<td>Best Fit<\/td>\n<td>Timing \/ Pulse \/ Encoder Measurement<\/td>\n<td>General Data Acquisition<\/td>\n<\/tr>\n<\/table>\n<h3>PCIe-6612 vs Basic Digital I\/O Card<\/h3>\n<p>\nA basic digital I\/O card normally reads or writes digital logic states. The PCIe-6612 adds dedicated counter\/timer hardware for measuring precise timing relationships between digital transitions.\n<\/p>\n<table>\n<tr>\n<th>\u0424\u0443\u043d\u043a\u0446\u0438\u044f<\/th>\n<th>PCIe-6612<\/th>\n<th>Basic Digital I\/O<\/th>\n<\/tr>\n<tr>\n<td>Static Digital I\/O<\/td>\n<td>\u0414\u0430<\/td>\n<td>\u0414\u0430<\/td>\n<\/tr>\n<tr>\n<td>Hardware Counters<\/td>\n<td><strong>8<\/strong><\/td>\n<td>Often Limited<\/td>\n<\/tr>\n<tr>\n<td>Frequency Measurement<\/td>\n<td><strong>Up to 80 MHz<\/strong><\/td>\n<td>Usually Limited<\/td>\n<\/tr>\n<tr>\n<td>Encoder Measurement<\/td>\n<td><strong>\u0414\u0430<\/strong><\/td>\n<td>Usually Requires Software or Extra Hardware<\/td>\n<\/tr>\n<tr>\n<td>Pulse Generation<\/td>\n<td><strong>Hardware Timed<\/strong><\/td>\n<td>Model Dependent<\/td>\n<\/tr>\n<tr>\n<td>Digital Debouncing<\/td>\n<td><strong>Programmable Filters<\/strong><\/td>\n<td>Model Dependent<\/td>\n<\/tr>\n<\/table>\n<h3>DMA Data Transfer<\/h3>\n<p>\nThe PCIe-6612 can perform <strong>three simultaneous high-speed DMA transfers<\/strong>.\n<\/p>\n<p>\nDMA is useful in applications involving continuous or hardware-timed measurements because data can move between the device and system memory without requiring the CPU to handle every individual sample.\n<\/p>\n<h3>68-Pin Connectivity<\/h3>\n<p>\nThe PCIe-6612 uses a high-density connection architecture for its counter and digital I\/O signals.\n<\/p>\n<p>\nNI lists compatible connectivity accessories including:\n<\/p>\n<ul>\n<li>TBX-68<\/li>\n<li>BNC-2121<\/li>\n<li>SCB-68A<\/li>\n<\/ul>\n<p>\nThe appropriate connector block and cable should be selected according to the required signal types, wiring method, shielding, and physical installation.\n<\/p>\n<h3>BNC-2121 Applications<\/h3>\n<p>\n\u0417\u0435\u043c\u043b\u044f <strong>BNC-2121<\/strong> provides convenient BNC-based access to compatible counter\/timer and digital signals.\n<\/p>\n<p>\nIt can be useful in laboratory environments where engineers frequently connect pulse generators, encoders, frequency sources, and measurement instruments through coaxial cables.\n<\/p>\n<h3>SCB-68A Applications<\/h3>\n<p>\n\u0417\u0435\u043c\u043b\u044f <strong>SCB-68A<\/strong> provides a shielded terminal connection solution for wiring field signals to compatible NI hardware.\n<\/p>\n<p>\nThis type of terminal block is useful when a permanent wired installation is preferred over BNC connectivity.\n<\/p>\n<h3>NI-DAQmx Integration<\/h3>\n<p>\nThe PCIe-6612 uses the <strong>\u041d\u0418-DAQmx<\/strong> driver architecture for counter\/timer and digital I\/O applications.\n<\/p>\n<p>\nNI-DAQmx can provide configuration for:\n<\/p>\n<ul>\n<li>Encoder measurements<\/li>\n<li>\u041f\u043e\u0434\u0441\u0447\u0435\u0442 \u0441\u043e\u0431\u044b\u0442\u0438\u0439<\/li>\n<li>Frequency measurement<\/li>\n<li>Period measurement<\/li>\n<li>Pulse-width measurement<\/li>\n<li>\u0413\u0435\u043d\u0435\u0440\u0430\u0446\u0438\u044f \u0438\u043c\u043f\u0443\u043b\u044c\u0441\u043e\u0432<\/li>\n<li>Pulse-train generation<\/li>\n<li>\u0426\u0438\u0444\u0440\u043e\u0432\u043e\u0439 \u0432\u0432\u043e\u0434-\u0432\u044b\u0432\u043e\u0434<\/li>\n<li>Hardware timing<\/li>\n<li>\u0417\u0430\u043f\u0443\u0441\u043a<\/li>\n<\/ul>\n<h3>LabVIEW Integration<\/h3>\n<p>\nThe PCIe-6612 can be integrated into LabVIEW applications through compatible NI-DAQmx software.\n<\/p>\n<p>\nA typical counter measurement workflow is:\n<\/p>\n<p>\n<strong>Create Counter Task \u2192 Configure Measurement \u2192 Configure Input Terminal \u2192 Start Task \u2192 Read Measurement \u2192 Analyze \/ Log Result<\/strong>\n<\/p>\n<p>\nFor generation:\n<\/p>\n<p>\n<strong>Create Counter Output Task \u2192 Configure Frequency \/ Duty Cycle \u2192 Start Output \u2192 Generate Pulse Train<\/strong>\n<\/p>\n<h3>Automated Test Applications<\/h3>\n<p>\nThe PCIe-6612 can provide precise digital timing measurements and stimulus generation within automated test systems.\n<\/p>\n<p>\nApplications can include:\n<\/p>\n<ul>\n<li>DUT frequency measurement<\/li>\n<li>Pulse-width verification<\/li>\n<li>PWM characterization<\/li>\n<li>Encoder simulation<\/li>\n<li>Clock generation<\/li>\n<li>Digital trigger generation<\/li>\n<li>\u041f\u043e\u0434\u0441\u0447\u0435\u0442 \u0441\u043e\u0431\u044b\u0442\u0438\u0439<\/li>\n<li>Timing validation<\/li>\n<\/ul>\n<h3>Industrial Motion Measurement<\/h3>\n<p>\nThe device can be used with compatible encoders and pulse-output sensors for motion measurement.\n<\/p>\n<p>\n\u0422\u0438\u043f\u0438\u0447\u043d\u044b\u0435 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f \u0432\u043a\u043b\u044e\u0447\u0430\u044e\u0442:\n<\/p>\n<ul>\n<li>Motor speed measurement<\/li>\n<li>Shaft position measurement<\/li>\n<li>Conveyor speed monitoring<\/li>\n<li>Linear-axis position<\/li>\n<li>Machine movement measurement<\/li>\n<\/ul>\n<h3>Scientific and Laboratory Measurement<\/h3>\n<p>\nCounter\/timer devices are also useful for scientific experiments that produce pulse, event, or frequency signals.\n<\/p>\n<p>\nExamples include:\n<\/p>\n<ul>\n<li>Detector pulse counting<\/li>\n<li>Timing experiments<\/li>\n<li>Frequency characterization<\/li>\n<li>Pulse-source measurement<\/li>\n<li>Laboratory automation<\/li>\n<\/ul>\n<h3>How to Choose a Counter\/Timer Device<\/h3>\n<p>\nBefore selecting the PCIe-6612, evaluate:\n<\/p>\n<ul>\n<li>Required number of counters<\/li>\n<li>Maximum input frequency<\/li>\n<li>Encoder type<\/li>\n<li>Required position measurement<\/li>\n<li>Event-counting requirements<\/li>\n<li>Frequency and period measurement requirements<\/li>\n<li>Pulse-width measurement requirements<\/li>\n<li>Pulse-generation requirements<\/li>\n<li>Number of digital I\/O channels<\/li>\n<li>Required digital logic level<\/li>\n<li>Digital filter requirements<\/li>\n<li>DMA requirements<\/li>\n<li>PCI Express slot availability<\/li>\n<li>Connector and terminal block requirements<\/li>\n<li>NI-DAQmx compatibility<\/li>\n<\/ul>\n<h3>Industries<\/h3>\n<ul>\n<li>Automated Test<\/li>\n<li>\u041f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u0430\u044f \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0437\u0430\u0446\u0438\u044f<\/li>\n<li>Motion Measurement<\/li>\n<li>Electronic Validation<\/li>\n<li>Manufacturing Test<\/li>\n<li>Motor Testing<\/li>\n<li>Scientific Research<\/li>\n<li>Laboratory Automation<\/li>\n<li>Machine Monitoring<\/li>\n<li>Research and Development<\/li>\n<\/ul>\n<h3>Applications<\/h3>\n<h4>Encoder Position Measurement<\/h4>\n<p>\nThe PCIe-6612 can measure compatible encoder signals for position, direction, and motion applications.\n<\/p>\n<h4>Frequency Measurement<\/h4>\n<p>\nThe device can measure digital signal frequencies up to 80 MHz for electronic, industrial, and laboratory applications.\n<\/p>\n<h4>Event Counting<\/h4>\n<p>\nExternal pulses can be counted using dedicated hardware counters for production, sensor, scientific, and automated test applications.\n<\/p>\n<h4>Pulse-Width Measurement<\/h4>\n<p>\nThe PCIe-6612 can measure the duration of digital pulses for PWM, timing, and device validation applications.\n<\/p>\n<h4>Pulse and Pulse-Train Generation<\/h4>\n<p>\nHardware counters can generate deterministic pulses and pulse trains for triggering, timing, clocking, and test stimulus applications.\n<\/p>\n<h4>Hardware-Timed Digital I\/O<\/h4>\n<p>\nPort 0 supports waveform digital acquisition and generation for applications requiring hardware-clocked digital patterns.\n<\/p>\n<h3>Recommended Related Products<\/h3>\n<table>\n<tr>\n<td width=\"220\"><strong>PCIe-6612<\/strong><\/td>\n<td>8-counter PCI Express device with 40 digital I\/O lines and frequency measurement up to 80 MHz.<\/td>\n<\/tr>\n<tr>\n<td><strong>PXIe-6612<\/strong><\/td>\n<td>PXI Express version providing closely related 8-counter and 40-DIO functionality for modular test systems.<\/td>\n<\/tr>\n<tr>\n<td><strong>PCI-6602<\/strong><\/td>\n<td>Legacy PCI counter\/timer device for applications requiring multiple hardware counters in existing PCI systems.<\/td>\n<\/tr>\n<tr>\n<td><strong>PCI-6601<\/strong><\/td>\n<td>Legacy counter\/timer device for lower-channel-count PCI measurement applications.<\/td>\n<\/tr>\n<tr>\n<td><strong>BNC-2121<\/strong><\/td>\n<td>BNC connector block for convenient laboratory access to counter\/timer and digital signals.<\/td>\n<\/tr>\n<tr>\n<td><strong>SCB-68A<\/strong><\/td>\n<td>Shielded connector block for wiring compatible PCIe-6612 digital and counter signals.<\/td>\n<\/tr>\n<\/table>\n<h3>Why Choose PCIe-6612?<\/h3>\n<ul>\n<li>8 hardware counter\/timers<\/li>\n<li>Up to 80 MHz frequency measurement<\/li>\n<li>Encoder position measurement<\/li>\n<li>\u041f\u043e\u0434\u0441\u0447\u0435\u0442 \u0441\u043e\u0431\u044b\u0442\u0438\u0439<\/li>\n<li>Period measurement<\/li>\n<li>Pulse-width measurement<\/li>\n<li>\u0413\u0435\u043d\u0435\u0440\u0430\u0446\u0438\u044f \u0438\u043c\u043f\u0443\u043b\u044c\u0441\u043e\u0432<\/li>\n<li>Pulse-train generation<\/li>\n<li>40 bidirectional digital I\/O channels<\/li>\n<li>5 V TTL\/CMOS-compatible I\/O<\/li>\n<li>Programmable digital debounce filters<\/li>\n<li>Hardware-timed waveform DIO<\/li>\n<li>Up to 10 MHz waveform digital I\/O<\/li>\n<li>Three simultaneous high-speed DMA transfers<\/li>\n<li>PCI Express interface<\/li>\n<li>NI-DAQmx support<\/li>\n<\/ul>\n<h3>Frequently Asked Questions<\/h3>\n<h4>What is the NI PCIe-6612?<\/h4>\n<p>\nThe NI PCIe-6612 is a PCI Express counter\/timer device with eight hardware counters and 40 bidirectional digital I\/O channels for encoder, pulse, frequency, timing, and digital applications.\n<\/p>\n<h4>What is the part number of PCIe-6612?<\/h4>\n<p>\nThe NI ordering part number for the PCIe-6612 is <strong>782351-01<\/strong>.\n<\/p>\n<h4>How many counters does PCIe-6612 have?<\/h4>\n<p>\nThe PCIe-6612 provides <strong>8 hardware counter\/timers<\/strong>.\n<\/p>\n<h4>What is the maximum frequency measurement of PCIe-6612?<\/h4>\n<p>\nThe PCIe-6612 supports frequency measurements up to <strong>80 MHz<\/strong>.\n<\/p>\n<h4>How many digital I\/O channels does PCIe-6612 provide?<\/h4>\n<p>\nThe PCIe-6612 provides <strong>40 bidirectional digital I\/O channels<\/strong>.\n<\/p>\n<h4>What logic level does PCIe-6612 use?<\/h4>\n<p>\nThe PCIe-6612 uses <strong>5 V TTL\/CMOS-compatible digital I\/O<\/strong>.\n<\/p>\n<h4>Can PCIe-6612 measure an encoder?<\/h4>\n<p>\nYes. Encoder position measurement is one of the primary applications of the PCIe-6612.\n<\/p>\n<h4>Can PCIe-6612 measure frequency?<\/h4>\n<p>\nYes. It can perform hardware-based frequency measurement on compatible digital signals, with supported measurement frequencies up to 80 MHz.\n<\/p>\n<h4>Can PCIe-6612 measure pulse width?<\/h4>\n<p>\nYes. The hardware counters support pulse-width measurement for timing, PWM, sensor, and electronic validation applications.\n<\/p>\n<h4>Can PCIe-6612 generate pulses?<\/h4>\n<p>\nYes. The counters can generate individual pulses and pulse trains for triggering, timing, stimulus generation, and synchronization.\n<\/p>\n<h4>Does PCIe-6612 support digital filtering?<\/h4>\n<p>\nYes. It includes programmable digital debouncing filters with settings including 160 ns, 10.24 \u00b5s, and 5.12 ms, as well as a disabled mode.\n<\/p>\n<h4>Does PCIe-6612 support hardware-timed digital I\/O?<\/h4>\n<p>\nYes. Port 0 supports waveform digital input and output with up to 32-bit sample widths and sample clocks up to approximately 10 MHz, subject to system and bus activity.\n<\/p>\n<h4>How many DMA transfers can PCIe-6612 perform?<\/h4>\n<p>\nThe PCIe-6612 can perform <strong>three simultaneous high-speed DMA transfers<\/strong>.\n<\/p>\n<h4>What is the difference between PCIe-6612 and PXIe-6612?<\/h4>\n<p>\nThe main difference is the host platform. PCIe-6612 installs in a PCI Express computer, while PXIe-6612 installs in a PXI Express chassis. Both provide eight counter\/timers, 40 digital I\/O channels, and up to 80 MHz frequency measurement capability.\n<\/p>\n<h4>Does PCIe-6612 have analog inputs?<\/h4>\n<p>\nNo. The PCIe-6612 is primarily a counter\/timer and digital I\/O device. Applications requiring analog measurements should use an appropriate NI DAQ device in addition to or instead of the PCIe-6612.\n<\/p>\n<h4>Can PCIe-6612 control a motor directly?<\/h4>\n<p>\nNo. The PCIe-6612 can generate compatible timing, pulse, encoder, or step signals, but motor power must be handled by an appropriate motor driver or controller.\n<\/p>\n<h4>What accessories can be used with PCIe-6612?<\/h4>\n<p>\nNI lists compatible connectivity options including the <strong>TBX-68, BNC-2121, and SCB-68A<\/strong>. The appropriate accessory should be selected according to the required signal connection and wiring architecture.\n<\/p>\n<h4>Is PCIe-6612 discontinued?<\/h4>\n<p>\nNo. NI currently lists <strong>782351-01 PCIe-6612<\/strong> \u043a\u0430\u043a <strong>Active<\/strong> product.\n<\/p>\n<h4>What should I check before purchasing PCIe-6612?<\/h4>\n<p>\nVerify the required number of counter\/timers, maximum input frequency, encoder type, pulse and timing requirements, number of digital I\/O lines, 5 V logic compatibility, digital filtering requirements, PCI Express slot availability, connection accessories, NI-DAQmx version, operating system compatibility, and application software.\n<\/p>\n<h3>\u0417\u0430\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435<\/h3>\n<p>\n\u0417\u0435\u043c\u043b\u044f <strong>NI PCIe-6612 Counter\/Timer Device<\/strong> combines eight hardware counter\/timers with 40 bidirectional 5 V digital I\/O channels, frequency measurement capability up to 80 MHz, encoder acquisition, programmable digital filters, hardware-timed waveform DIO, pulse generation, and multiple high-speed DMA channels. These capabilities make the PCIe-6612 well suited for encoder position measurement, event counting, frequency and period measurement, pulse-width analysis, pulse generation, motion measurement, automated test, industrial timing, and electronic validation applications.<\/p>","protected":false},"excerpt":{"rendered":"<p>\u0428\u0438\u043d\u0430: PCI Express<br \/>\nNumber of Bidirectional Digital Channels: 40<br \/>\nLogic Levels And Range: 5 V TTL<br \/>\n\u041a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u0441\u0447\u0435\u0442\u0447\u0438\u043a\u043e\u0432\/\u0442\u0430\u0439\u043c\u0435\u0440\u043e\u0432: 8<\/p>","protected":false},"featured_media":31155,"template":"","meta":{"_acf_changed":false},"product_brand":[18],"product_cat":[674],"product_tag":[],"class_list":["post-34529","product","type-product","status-publish","has-post-thumbnail","product_brand-national-instruments","product_cat-pci-usb","first","instock","shipping-taxable","purchasable","product-type-simple"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.0 (Yoast SEO v28.1) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>NI PCIe-6612 PCIe Counter\/Timer Device 782351-01, In Stock | Project Pricing<\/title>\n<meta name=\"description\" content=\"NI PCIe-6612 is an 8-channel PCI Express counter\/timer device with 40 bidirectional digital I\/O lines, 80 MHz frequency measurement and encoder support.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/pxisource.com\/ru\/product\/pcie-6612\/\" \/>\n<meta property=\"og:locale\" content=\"ru_RU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"PCIe-6612\" \/>\n<meta property=\"og:description\" content=\"NI PCIe-6612 is an 8-channel PCI Express counter\/timer device with 40 bidirectional digital I\/O lines, 80 MHz frequency measurement and encoder support.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/pxisource.com\/ru\/product\/pcie-6612\/\" \/>\n<meta property=\"og:site_name\" content=\"PXI Source\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=61582573040385\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-27T10:29:25+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PCIe-6612.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"800\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u0426\u0435\u043d\u0430\" \/>\n\t<meta name=\"twitter:data1\" content=\"&#036;1,612.00\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c\" \/>\n\t<meta name=\"twitter:data2\" content=\"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pcie-6612\\\/\",\"url\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pcie-6612\\\/\",\"name\":\"NI PCIe-6612 PCIe Counter\\\/Timer Device 782351-01, In Stock | Project Pricing\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pcie-6612\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pcie-6612\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/PCIe-6612.webp\",\"datePublished\":\"2026-08-07T04:29:04+00:00\",\"dateModified\":\"2026-08-27T10:29:25+00:00\",\"description\":\"NI PCIe-6612 is an 8-channel PCI Express counter\\\/timer device with 40 bidirectional digital I\\\/O lines, 80 MHz frequency measurement and encoder support.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pcie-6612\\\/#breadcrumb\"},\"inLanguage\":\"ru-RU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/pxisource.com\\\/product\\\/pcie-6612\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pcie-6612\\\/#primaryimage\",\"url\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/PCIe-6612.webp\",\"contentUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/PCIe-6612.webp\",\"width\":800,\"height\":800,\"caption\":\"PCIe-6612\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pcie-6612\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/pxisource.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u5546\u5e97\",\"item\":\"https:\\\/\\\/pxisource.com\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"PCIe-6612\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\",\"url\":\"https:\\\/\\\/pxisource.com\\\/\",\"name\":\"PXI Systems\",\"description\":\"PXI, PXIe and Modular Test Equipment\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/pxisource.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ru-RU\"}]}<\/script>\n<meta property=\"product:brand\" content=\"National Instruments\" \/>\n<meta property=\"product:price:amount\" content=\"1612.00\" \/>\n<meta property=\"product:price:currency\" content=\"USD\" \/>\n<meta property=\"og:availability\" content=\"instock\" \/>\n<meta property=\"product:availability\" content=\"instock\" \/>\n<meta property=\"product:condition\" content=\"new\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"NI PCIe-6612 PCIe Counter\/Timer Device 782351-01, In Stock | Project Pricing","description":"NI PCIe-6612 is an 8-channel PCI Express counter\/timer device with 40 bidirectional digital I\/O lines, 80 MHz frequency measurement and encoder support.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/pxisource.com\/ru\/product\/pcie-6612\/","og_locale":"ru_RU","og_type":"article","og_title":"PCIe-6612","og_description":"NI PCIe-6612 is an 8-channel PCI Express counter\/timer device with 40 bidirectional digital I\/O lines, 80 MHz frequency measurement and encoder support.","og_url":"https:\/\/pxisource.com\/ru\/product\/pcie-6612\/","og_site_name":"PXI Source","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=61582573040385","article_modified_time":"2026-08-27T10:29:25+00:00","og_image":[{"width":800,"height":800,"url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PCIe-6612.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"\u0426\u0435\u043d\u0430":"&#36;1,612.00","\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c":"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/pxisource.com\/product\/pcie-6612\/","url":"https:\/\/pxisource.com\/product\/pcie-6612\/","name":"NI PCIe-6612 PCIe Counter\/Timer Device 782351-01, In Stock | Project Pricing","isPartOf":{"@id":"https:\/\/pxisource.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/pxisource.com\/product\/pcie-6612\/#primaryimage"},"image":{"@id":"https:\/\/pxisource.com\/product\/pcie-6612\/#primaryimage"},"thumbnailUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PCIe-6612.webp","datePublished":"2026-08-07T04:29:04+00:00","dateModified":"2026-08-27T10:29:25+00:00","description":"NI PCIe-6612 is an 8-channel PCI Express counter\/timer device with 40 bidirectional digital I\/O lines, 80 MHz frequency measurement and encoder support.","breadcrumb":{"@id":"https:\/\/pxisource.com\/product\/pcie-6612\/#breadcrumb"},"inLanguage":"ru-RU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/pxisource.com\/product\/pcie-6612\/"]}]},{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/pxisource.com\/product\/pcie-6612\/#primaryimage","url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PCIe-6612.webp","contentUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PCIe-6612.webp","width":800,"height":800,"caption":"PCIe-6612"},{"@type":"BreadcrumbList","@id":"https:\/\/pxisource.com\/product\/pcie-6612\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/pxisource.com\/"},{"@type":"ListItem","position":2,"name":"\u5546\u5e97","item":"https:\/\/pxisource.com\/shop\/"},{"@type":"ListItem","position":3,"name":"PCIe-6612"}]},{"@type":"WebSite","@id":"https:\/\/pxisource.com\/#website","url":"https:\/\/pxisource.com\/","name":"\u0421\u0438\u0441\u0442\u0435\u043c\u044b PXI","description":"PXI, PXIe and Modular Test Equipment","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/pxisource.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ru-RU"}]},"product_brand":"National Instruments","product_price_amount":"1612.00","product_price_currency":"USD","og_availability":"instock","product_availability":"instock","product_condition":"new"},"_links":{"self":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/34529","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":3,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/34529\/revisions"}],"predecessor-version":[{"id":35491,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/34529\/revisions\/35491"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media\/31155"}],"wp:attachment":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media?parent=34529"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_brand?post=34529"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_cat?post=34529"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_tag?post=34529"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}