{"id":32833,"date":"2026-05-15T11:43:10","date_gmt":"2026-05-15T03:43:10","guid":{"rendered":"https:\/\/pxisource.com\/?post_type=product&#038;p=32833"},"modified":"2026-05-15T11:43:13","modified_gmt":"2026-05-15T03:43:13","slug":"pxie-2527","status":"publish","type":"product","link":"https:\/\/pxisource.com\/ru\/product\/pxie-2527","title":{"rendered":"PXIe-2527"},"content":{"rendered":"<p data-path-to-node=\"2\">The NI PXIe-2527 is a high-voltage, high-power multiplexer switch module designed for the PXI Express platform. It is engineered for applications that require a combination of high-channel density and the ability to handle significant voltage and current. Software-configurable as a 32-channel 1-wire multiplexer or a 16-channel 2-wire multiplexer, this module serves as the primary power-switching interface for automotive, aerospace, and industrial energy systems where signal integrity and high-voltage isolation are non-negotiable.<\/p>\n<h3 data-path-to-node=\"3\">1. \u041a\u043b\u044e\u0447\u0435\u0432\u044b\u0435 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438<\/h3>\n<p data-path-to-node=\"4\"><b data-path-to-node=\"4\" data-index-in-node=\"0\">\u041a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u043a\u0430\u043d\u0430\u043b\u043e\u0432:<\/b> 32 (1-wire) or 16 (2-wire) <b data-path-to-node=\"4\" data-index-in-node=\"42\">\u0422\u043e\u043f\u043e\u043b\u043e\u0433\u0438\u044f:<\/b> \u041f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e-\u043a\u043e\u043d\u0444\u0438\u0433\u0443\u0440\u0438\u0440\u0443\u0435\u043c\u044b\u0439 \u043c\u0443\u043b\u044c\u0442\u0438\u043f\u043b\u0435\u043a\u0441\u043e\u0440 <b data-path-to-node=\"4\" data-index-in-node=\"86\">\u0422\u0438\u043f \u0440\u0435\u043b\u0435:<\/b> \u042d\u043b\u0435\u043a\u0442\u0440\u043e\u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0439 (\u043d\u0435\u0444\u0438\u043a\u0441\u0438\u0440\u0443\u044e\u0449\u0438\u0439\u0441\u044f) <b data-path-to-node=\"4\" data-index-in-node=\"131\">\u041c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u0435 \u043a\u043e\u043c\u043c\u0443\u0442\u0430\u0446\u0438\u043e\u043d\u043d\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435:<\/b> 300 VDC \/ 300 VAC (CAT I) <b data-path-to-node=\"4\" data-index-in-node=\"180\">\u041c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0439 \u043a\u043e\u043c\u043c\u0443\u0442\u0438\u0440\u0443\u0435\u043c\u044b\u0439 \u0442\u043e\u043a:<\/b> 2.0 \u0410 (\u043d\u0430 \u043a\u0430\u043d\u0430\u043b) <b data-path-to-node=\"4\" data-index-in-node=\"223\">\u041c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u0430\u044f \u043a\u043e\u043c\u043c\u0443\u0442\u0438\u0440\u0443\u0435\u043c\u0430\u044f \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u044c:<\/b> 60 \u0412\u0410 \/ 62,5 \u0412\u0410 <b data-path-to-node=\"4\" data-index-in-node=\"259\">\u0421\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 \u043f\u0443\u0442\u0438:<\/b> &lt; 0.5 \u03a9 (Initial) <b data-path-to-node=\"4\" data-index-in-node=\"294\">\u0421\u043a\u043e\u0440\u043e\u0441\u0442\u044c \u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f:<\/b> 145 \u0446\u0438\u043a\u043b\u043e\u0432 \u0432 \u0441\u0435\u043a\u0443\u043d\u0434\u0443 <b data-path-to-node=\"4\" data-index-in-node=\"333\">\u0428\u0438\u043d\u043d\u044b\u0439 \u0438\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441<\/b> PXI Express (Gen 1 x1)<\/p>\n<h3 data-path-to-node=\"5\">2. \u041f\u043e\u0434\u0440\u043e\u0431\u043d\u043e\u0435 \u0442\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435 \u043e\u043f\u0438\u0441\u0430\u043d\u0438\u0435<\/h3>\n<p data-path-to-node=\"6\"><b data-path-to-node=\"6\" data-index-in-node=\"0\">High-Voltage and High-Current Capacity<\/b> The defining characteristic of the PXIe-2527 is its robust power handling. While many high-density multiplexers are limited to 100V or 150V, the PXIe-2527 supports up to 300V. Additionally, its 2A current capacity allows it to switch small loads, power supplies, and high-level signals that would damage standard signal-level switches. This makes it a &#8220;universal&#8221; multiplexer capable of handling both low-level sensor data and high-level power rails.<\/p>\n<p data-path-to-node=\"7\"><b data-path-to-node=\"7\" data-index-in-node=\"0\">Advanced PXI Express Synchronization<\/b> As a PXIe module, the PXIe-2527 utilizes the advanced timing and triggering capabilities of the PXI Express backplane. It supports hardware-timed scanning, allowing the switch to cycle through its scan list based on triggers from a PXIe DMM or digitizer. This eliminates the latency inherent in software-controlled switching, ensuring that measurements are taken at the exact moment the relay has settled, maximizing test throughput and deterministic timing.<\/p>\n<p data-path-to-node=\"8\"><b data-path-to-node=\"8\" data-index-in-node=\"0\">Reliability and Health Tracking<\/b> For critical manufacturing and validation environments, the PXIe-2527 includes an integrated relay counter. Every time a relay is activated, the count is stored in non-volatile memory on the module. Through the NI-SWITCH driver, engineers can monitor the wear on each of the 32 relays. This enables predictive maintenance, allowing for module replacement before a mechanical failure occurs, which is essential for maintaining 24\/7 production line uptime.<\/p>\n<h3 data-path-to-node=\"9\">3. \u0421\u0446\u0435\u043d\u0430\u0440\u0438\u0438 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f \u0438 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f<\/h3>\n<p data-path-to-node=\"10\"><b data-path-to-node=\"10\" data-index-in-node=\"0\">Power Supply and Battery Validation<\/b> In EV battery and power supply testing, the PXIe-2527 is used to route various power rails and cell voltages to measurement instruments. Its 300V rating provides the necessary safety margin for testing medium-voltage battery stacks and industrial power converters.<\/p>\n<p data-path-to-node=\"11\"><b data-path-to-node=\"11\" data-index-in-node=\"0\">Automotive ECU Functional Test<\/b> The module is frequently used in ECU testers to simulate various high-level sensor inputs and to route power-on signals. Its 2A capacity allows it to drive typical automotive solenoids and relays directly during functional verification.<\/p>\n<p data-path-to-node=\"12\"><b data-path-to-node=\"12\" data-index-in-node=\"0\">Industrial Control and Energy Monitoring<\/b> For monitoring industrial machinery or solar power systems, the PXIe-2527 acts as a rugged front-end. Its 2-wire configuration is perfect for differential measurements of thermocouples and high-voltage sensors in electrically noisy industrial environments.<\/p>\n<h3 data-path-to-node=\"13\">4. \u0421\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0434\u0443\u043a\u0442\u043e\u0432 \u0438 \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0430\u0446\u0438\u0438<\/h3>\n<p data-path-to-node=\"14\"><b data-path-to-node=\"14\" data-index-in-node=\"0\">NI PXIe-2527 (\u0418\u0434\u0435\u0430\u043b\u044c\u043d\u044b\u0439 \u0432\u044b\u0431\u043e\u0440)<\/b> 32 channels, 300V\/2A. Best for applications requiring higher voltage and current handling at moderate channel counts.<\/p>\n<p data-path-to-node=\"15\"><b data-path-to-node=\"15\" data-index-in-node=\"0\">NI PXIe-2524 (The Density Choice)<\/b> 128 channels, 150V\/1A. Best for high-channel-count sensor logging where voltages do not exceed 150V and space is the primary constraint.<\/p>\n<p data-path-to-node=\"16\"><b data-path-to-node=\"16\" data-index-in-node=\"0\">NI PXIe-2529 (The Matrix Choice)<\/b> 128 crosspoints, 150V\/1A. Best for applications requiring any-to-any connectivity (matrix) rather than sequential signal routing (multiplexer).<\/p>\n<h3 data-path-to-node=\"17\">\u0420\u0435\u0437\u044e\u043c\u0435<\/h3>\n<p data-path-to-node=\"18\">The NI PXIe-2527 is a robust and versatile switching solution for engineers who refuse to compromise on power capacity or precision. By combining 300V\/2A ratings with the high-speed synchronization of PXI Express, it provides a stable foundation for the most demanding automated test environments. We offer professional technical support for high-voltage system integration and support project pricing for large-scale production deployments and multi-module upgrades.<\/p>","protected":false},"excerpt":{"rendered":"<p>Scan Rate: 140 cycles\/s<br \/>\nMode (n-wire): 1-wire, 2-wire, 4-wire<br \/>\n\u0428\u0438\u043d\u043d\u044b\u0439 \u0441\u043e\u0435\u0434\u0438\u043d\u0438\u0442\u0435\u043b\u044c: PXI Express<br \/>\n\u041c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0439 \u043a\u043e\u043c\u043c\u0443\u0442\u0438\u0440\u0443\u0435\u043c\u044b\u0439 \u0442\u043e\u043a \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430: 2 \u0410<br \/>\nMaximum Switching Voltage DC: 300 V<br \/>\n\u0422\u0438\u043f \u0440\u0435\u043b\u0435: \u042d\u043b\u0435\u043a\u0442\u0440\u043e\u043c\u0435\u0445\u0430\u043d\u0438\u0447\u0435\u0441\u043a\u043e\u0435<br \/>\n\u041f\u0440\u043e\u043f\u0443\u0441\u043a\u043d\u0430\u044f \u0441\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u044c \u043a\u043e\u043c\u043c\u0443\u0442\u0430\u0442\u043e\u0440\u0430: 30 \u041c\u0413\u0446<br \/>\nNumber of Channels: 16, 32, 64<br \/>\n\u041a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u0431\u0430\u043d\u043a\u043e\u0432: 1, 2<\/p>","protected":false},"featured_media":32724,"template":"","meta":{"_acf_changed":false},"product_brand":[18],"product_cat":[667],"product_tag":[],"class_list":["post-32833","product","type-product","status-publish","has-post-thumbnail","product_brand-national-instruments","product_cat-pxi-modules","first","instock","shipping-taxable","purchasable","product-type-simple"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.0 (Yoast SEO v27.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>NI PXIe-2527 PXI Multiplexer Switch Module 780587-27<\/title>\n<meta name=\"description\" content=\"NI PXIe-2527 32-channel high-voltage PXIe multiplexer, 300V\/2A. Precision power and signal routing. Expert support &amp; project pricing available.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/pxisource.com\/ru\/product\/pxie-2527\/\" \/>\n<meta property=\"og:locale\" content=\"ru_RU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"PXIe-2527\" \/>\n<meta property=\"og:description\" content=\"NI PXIe-2527 32-channel high-voltage PXIe multiplexer, 300V\/2A. Precision power and signal routing. Expert support &amp; project pricing available.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/pxisource.com\/ru\/product\/pxie-2527\/\" \/>\n<meta property=\"og:site_name\" content=\"essence instrument\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=61582573040385\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-15T03:43:13+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/pxisource.com\/wp-content\/uploads\/2026\/05\/PXIe-2527.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"800\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u0426\u0435\u043d\u0430\" \/>\n\t<meta name=\"twitter:data1\" content=\"&#036;3,400.00\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c\" \/>\n\t<meta name=\"twitter:data2\" content=\"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-2527\",\"url\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-2527\",\"name\":\"NI PXIe-2527 PXI Multiplexer Switch Module 780587-27\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-2527#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-2527#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/PXIe-2527.webp\",\"datePublished\":\"2026-05-15T03:43:10+00:00\",\"dateModified\":\"2026-05-15T03:43:13+00:00\",\"description\":\"NI PXIe-2527 32-channel high-voltage PXIe multiplexer, 300V\\\/2A. Precision power and signal routing. Expert support & project pricing available.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-2527#breadcrumb\"},\"inLanguage\":\"ru-RU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-2527\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-2527#primaryimage\",\"url\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/PXIe-2527.webp\",\"contentUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/PXIe-2527.webp\",\"width\":800,\"height\":800,\"caption\":\"PXIe-2527\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-2527#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/pxisource.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u5546\u5e97\",\"item\":\"https:\\\/\\\/pxisource.com\\\/shop\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"PXIe-2527\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\",\"url\":\"https:\\\/\\\/pxisource.com\\\/\",\"name\":\"essence instrument\",\"description\":\"essence instrument\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/pxisource.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ru-RU\"}]}<\/script>\n<meta property=\"product:price:amount\" content=\"3400.00\" \/>\n<meta property=\"product:price:currency\" content=\"USD\" \/>\n<meta property=\"og:availability\" content=\"instock\" \/>\n<meta property=\"product:availability\" content=\"instock\" \/>\n<meta property=\"product:condition\" content=\"new\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"NI PXIe-2527 PXI Multiplexer Switch Module 780587-27","description":"NI PXIe-2527 32-channel high-voltage PXIe multiplexer, 300V\/2A. Precision power and signal routing. Expert support & project pricing available.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/pxisource.com\/ru\/product\/pxie-2527\/","og_locale":"ru_RU","og_type":"article","og_title":"PXIe-2527","og_description":"NI PXIe-2527 32-channel high-voltage PXIe multiplexer, 300V\/2A. Precision power and signal routing. Expert support & project pricing available.","og_url":"https:\/\/pxisource.com\/ru\/product\/pxie-2527\/","og_site_name":"essence instrument","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=61582573040385","article_modified_time":"2026-05-15T03:43:13+00:00","og_image":[{"width":800,"height":800,"url":"http:\/\/pxisource.com\/wp-content\/uploads\/2026\/05\/PXIe-2527.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"\u0426\u0435\u043d\u0430":"&#36;3,400.00","\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c":"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/pxisource.com\/product\/pxie-2527","url":"https:\/\/pxisource.com\/product\/pxie-2527","name":"NI PXIe-2527 PXI Multiplexer Switch Module 780587-27","isPartOf":{"@id":"https:\/\/pxisource.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/pxisource.com\/product\/pxie-2527#primaryimage"},"image":{"@id":"https:\/\/pxisource.com\/product\/pxie-2527#primaryimage"},"thumbnailUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/05\/PXIe-2527.webp","datePublished":"2026-05-15T03:43:10+00:00","dateModified":"2026-05-15T03:43:13+00:00","description":"NI PXIe-2527 32-channel high-voltage PXIe multiplexer, 300V\/2A. Precision power and signal routing. Expert support & project pricing available.","breadcrumb":{"@id":"https:\/\/pxisource.com\/product\/pxie-2527#breadcrumb"},"inLanguage":"ru-RU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/pxisource.com\/product\/pxie-2527"]}]},{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/pxisource.com\/product\/pxie-2527#primaryimage","url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/05\/PXIe-2527.webp","contentUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/05\/PXIe-2527.webp","width":800,"height":800,"caption":"PXIe-2527"},{"@type":"BreadcrumbList","@id":"https:\/\/pxisource.com\/product\/pxie-2527#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/pxisource.com\/"},{"@type":"ListItem","position":2,"name":"\u5546\u5e97","item":"https:\/\/pxisource.com\/shop"},{"@type":"ListItem","position":3,"name":"PXIe-2527"}]},{"@type":"WebSite","@id":"https:\/\/pxisource.com\/#website","url":"https:\/\/pxisource.com\/","name":"\u0441\u0443\u0449\u043d\u043e\u0441\u0442\u044c \u0438\u043d\u0441\u0442\u0440\u0443\u043c\u0435\u043d\u0442\u0430","description":"\u0441\u0443\u0449\u043d\u043e\u0441\u0442\u044c \u0438\u043d\u0441\u0442\u0440\u0443\u043c\u0435\u043d\u0442\u0430","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/pxisource.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ru-RU"}]},"product_price_amount":"3400.00","product_price_currency":"USD","og_availability":"instock","product_availability":"instock","product_condition":"new"},"_links":{"self":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/32833","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":1,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/32833\/revisions"}],"predecessor-version":[{"id":32834,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/32833\/revisions\/32834"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media\/32724"}],"wp:attachment":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media?parent=32833"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_brand?post=32833"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_cat?post=32833"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_tag?post=32833"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}