{"id":32788,"date":"2026-05-13T15:44:25","date_gmt":"2026-05-13T07:44:25","guid":{"rendered":"https:\/\/pxisource.com\/?post_type=product&#038;p=32788"},"modified":"2026-08-29T14:47:33","modified_gmt":"2026-08-29T06:47:33","slug":"pxie-4330","status":"publish","type":"product","link":"https:\/\/pxisource.com\/ru\/product\/pxie-4330\/","title":{"rendered":"PXIe-4330"},"content":{"rendered":"<h3>PXIe-4330 8-Channel Strain and Bridge Input Module<\/h3>\n<p>\u0417\u0435\u043c\u043b\u044f <strong>PXIe-4330<\/strong> is an 8-channel, 24-bit PXI Express strain and bridge input module with integrated signal conditioning for bridge-based sensors. It supports strain gauges, load cells, pressure transducers, torque sensors and other Wheatstone bridge devices.<\/p>\n<p>All eight channels sample simultaneously at rates up to <strong>25,6 \u0442\u044b\u0441. \u043e\u0442\u0441\u0447\u0435\u0442\u043e\u0432\/\u0441 \u043d\u0430 \u043a\u0430\u043d\u0430\u043b<\/strong>. Each channel provides independently programmable excitation, remote sensing, bridge completion, digital filtering and shunt calibration.<\/p>\n<h3>Key Features of the PXIe-4330<\/h3>\n<ul>\n<li>8 simultaneous strain and bridge input channels<\/li>\n<li>24-bit analog input resolution<\/li>\n<li>25.6 kS\/s maximum sampling rate per channel<\/li>\n<li>Dedicated delta-sigma ADC for each channel<\/li>\n<li>Full-, half- and quarter-bridge support<\/li>\n<li>120 \u03a9, 350 \u03a9 and 1 k\u03a9 quarter-bridge completion<\/li>\n<li>Independent programmable excitation for every channel<\/li>\n<li>Excitation settings from 0.625 V to 10 V<\/li>\n<li>Remote excitation sensing<\/li>\n<li>Internal and external shunt calibration options<\/li>\n<li>Per-channel anti-alias and digital filtering<\/li>\n<li>Simultaneous sampling for synchronized measurements<\/li>\n<li>NI-DAQmx driver support<\/li>\n<\/ul>\n<h3>PXIe-4330 Technical Specifications<\/h3>\n<table>\n<tbody>\n<tr>\n<th>Product Model<\/th>\n<td>PXIe-4330<\/td>\n<\/tr>\n<tr>\n<th>Part Number<\/th>\n<td>781346-01<\/td>\n<\/tr>\n<tr>\n<th>Product Type<\/th>\n<td>PXI Express Strain and Bridge Input Module<\/td>\n<\/tr>\n<tr>\n<th>Input Channels<\/th>\n<td>8 differential bridge input channels<\/td>\n<\/tr>\n<tr>\n<th>ADC Resolution<\/th>\n<td>24 bit<\/td>\n<\/tr>\n<tr>\n<th>ADC Type<\/th>\n<td>Delta-sigma with analog prefiltering<\/td>\n<\/tr>\n<tr>\n<th>Sampling Mode<\/th>\n<td>\u0421\u0438\u043d\u0445\u0440\u043e\u043d\u043d\u044b\u0439<\/td>\n<\/tr>\n<tr>\n<th>Maximum Sample Rate<\/th>\n<td>25,6 \u0442\u044b\u0441. \u043e\u0442\u0441\u0447\u0435\u0442\u043e\u0432\/\u0441 \u043d\u0430 \u043a\u0430\u043d\u0430\u043b<\/td>\n<\/tr>\n<tr>\n<th>Input Ranges<\/th>\n<td>\u00b125 mV\/V and \u00b1100 mV\/V<\/td>\n<\/tr>\n<tr>\n<th>Bridge Configurations<\/th>\n<td>Full, half and quarter bridge<\/td>\n<\/tr>\n<tr>\n<th>Quarter-Bridge Completion<\/th>\n<td>120 \u03a9, 350 \u03a9 and 1 k\u03a9<\/td>\n<\/tr>\n<tr>\n<th>Excitation Type<\/th>\n<td>Balanced constant differential voltage<\/td>\n<\/tr>\n<tr>\n<th>Excitation Settings<\/th>\n<td>0.625 V, 1 V, 1.5 V, 2 V, 2.5 V, 2.75 V, 3.3 V, 5 V, 7.5 V and 10 V<\/td>\n<\/tr>\n<tr>\n<th>Shunt Calibration Resistors<\/th>\n<td>33.333 k\u03a9, 50 k\u03a9 and 100 k\u03a9<\/td>\n<\/tr>\n<tr>\n<th>Common-Mode Input Range<\/th>\n<td>\u00b12 V<\/td>\n<\/tr>\n<tr>\n<th>Common-Mode Rejection<\/th>\n<td>85 dB, DC to 1 kHz<\/td>\n<\/tr>\n<tr>\n<th>FIFO Buffer<\/th>\n<td>1,023 samples<\/td>\n<\/tr>\n<tr>\n<th>Data Transfers<\/th>\n<td>DMA and programmed I\/O<\/td>\n<\/tr>\n<tr>\n<th>Bus Type<\/th>\n<td>PXI Express<\/td>\n<\/tr>\n<tr>\n<th>Operating Temperature<\/th>\n<td>0\u00b0C to 55\u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>PXIe-4330 Part Number and Accessories<\/h3>\n<table>\n<tbody>\n<tr>\n<th>Item<\/th>\n<th>Part Number<\/th>\n<th>\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435<\/th>\n<\/tr>\n<tr>\n<td>PXIe-4330<\/td>\n<td>781346-01<\/td>\n<td>8-channel, 24-bit strain and bridge input module<\/td>\n<\/tr>\n<tr>\n<td>TB-4330<\/td>\n<td>781347-01<\/td>\n<td>Front-mount terminal block for PXIe-4330 and PXIe-4331<\/td>\n<\/tr>\n<tr>\n<td>RM-24999<\/td>\n<td>785840-01<\/td>\n<td>Rack-mount terminal block for PXIe-4330 and PXIe-4331<\/td>\n<\/tr>\n<tr>\n<td>Shielded Rack-Mount Cable<\/td>\n<td>786341-01<\/td>\n<td>1 m shielded cable for connecting the module to RM-24999<\/td>\n<\/tr>\n<tr>\n<td>Shielded Rack-Mount Cable<\/td>\n<td>786341-03<\/td>\n<td>3 m shielded cable for connecting the module to RM-24999<\/td>\n<\/tr>\n<tr>\n<td>Shielded Rack-Mount Cable<\/td>\n<td>786341-05<\/td>\n<td>5 m shielded cable for connecting the module to RM-24999<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The TB-4330 mounts directly on the front of the module. The RM-24999 is intended for rack-mounted systems and requires a compatible shielded cable.<\/p>\n<h3>Simultaneous Bridge Measurements<\/h3>\n<p>The PXIe-4330 includes a dedicated 24-bit ADC for each of its eight input channels. All channels acquire data simultaneously, preserving the timing and phase relationships between multiple bridge sensors.<\/p>\n<p>This is important for structural testing, load distribution measurements and dynamic systems where data from several sensors must be compared at the same instant.<\/p>\n<h3>Full-, Half- and Quarter-Bridge Support<\/h3>\n<p>The module supports full-, half- and quarter-bridge configurations. Bridge mode can be selected independently for each channel through the measurement software.<\/p>\n<p>Internal bridge completion simplifies connection of quarter- and half-bridge sensors by reducing the need for external precision completion resistors.<\/p>\n<h3>Quarter-Bridge Completion<\/h3>\n<p>The PXIe-4330 provides internal quarter-bridge completion for <strong>120 \u03a9, 350 \u03a9 and 1 k\u03a9<\/strong> strain gauges. The appropriate resistance must be selected to match the connected sensor.<\/p>\n<p>Incorrect completion resistance can cause offset, scaling errors or invalid measurements. Confirm the nominal gauge resistance before configuring the channel.<\/p>\n<h3>Programmable Excitation Voltage<\/h3>\n<p>Every input channel provides an independently programmable balanced excitation source. Available settings include 0.625 V, 1 V, 1.5 V, 2 V, 2.5 V, 2.75 V, 3.3 V, 5 V, 7.5 V and 10 V.<\/p>\n<p>Independent excitation allows different sensor types and bridge resistances to be used on the same module. The maximum suitable excitation depends on the bridge configuration and resistance.<\/p>\n<h3>Remote Excitation Sensing<\/h3>\n<p>Remote sensing compensates for voltage loss in the excitation wiring between the module and the bridge sensor. Separate sense connections measure the actual excitation voltage at the sensor.<\/p>\n<p>This feature improves measurement accuracy when sensors are installed far from the PXI system or when excitation cables have significant resistance.<\/p>\n<h3>Shunt Calibration<\/h3>\n<p>The PXIe-4330 supports software-selectable internal and external shunt calibration on individual channels. Internal shunt values include <strong>33.333 k\u03a9, 50 k\u03a9 and 100 k\u03a9<\/strong>.<\/p>\n<p>Shunt calibration introduces a known electrical imbalance into the bridge. The resulting measurement can be used to verify wiring, channel scaling, bridge completion and the operation of the measurement chain.<\/p>\n<h3>Anti-Alias and Digital Filtering<\/h3>\n<p>Each PXIe-4330 channel includes analog prefiltering and digital filtering. These filters reduce out-of-band noise and help prevent high-frequency signals from appearing incorrectly in the acquired data.<\/p>\n<p>Filter behavior is associated with the configured sampling rate and should be selected according to the expected signal bandwidth.<\/p>\n<h3>Strain Gauge Measurements<\/h3>\n<p>The module can acquire full-, half- and quarter-bridge strain gauges. Integrated excitation, bridge completion, remote sensing and shunt calibration reduce the need for separate external signal-conditioning hardware.<\/p>\n<p>Accurate strain measurements require the correct gauge factor, bridge configuration, nominal resistance, excitation voltage and mechanical scaling.<\/p>\n<h3>Load Cell and Force Measurements<\/h3>\n<p>Full-bridge load cells can be connected directly to the PXIe-4330. The module measures the sensor output in mV\/V and uses the configured sensitivity or calibration data to convert the reading into force or weight.<\/p>\n<p>Remote sensing can improve accuracy when load cells are connected through long cables.<\/p>\n<h3>Pressure and Torque Measurements<\/h3>\n<p>Bridge-based pressure transducers and torque sensors are also supported. Individual channel configuration allows sensors with different excitation, sensitivity and physical units to operate on the same module.<\/p>\n<p>Manufacturer calibration values should be entered correctly to convert the electrical bridge output into pressure or torque units.<\/p>\n<h3>\u0422\u0438\u043f\u0438\u0447\u043d\u044b\u0435 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f<\/h3>\n<ul>\n<li>Strain gauge measurement<\/li>\n<li>Load cell and force testing<\/li>\n<li>Bridge-based pressure measurement<\/li>\n<li>Torque sensor acquisition<\/li>\n<li>Structural and fatigue testing<\/li>\n<li>Automotive component validation<\/li>\n<li>Aerospace structural testing<\/li>\n<li>Material testing systems<\/li>\n<li>Mechanical load monitoring<\/li>\n<li>Automated production testing<\/li>\n<\/ul>\n<h3>NI-DAQmx Software Support<\/h3>\n<p>The PXIe-4330 is supported by the NI-DAQmx driver. NI-DAQmx provides configuration for bridge type, excitation, gauge resistance, shunt calibration, timing, triggering, filtering and engineering-unit scaling.<\/p>\n<p>Applications can be developed using LabVIEW, Python, C, C# and other supported programming environments.<\/p>\n<h3>FlexLogger Integration<\/h3>\n<p>FlexLogger can configure and record strain, force, pressure and torque measurements without requiring a complete custom application. Users can define sensor sensitivities, engineering units, sample rates, alarms and logging conditions.<\/p>\n<p>This makes the PXIe-4330 suitable for interactive validation, structural testing and long-duration measurement systems.<\/p>\n<h3>PXI Express System Integration<\/h3>\n<p>The PXIe-4330 requires a compatible PXI Express chassis and controller. Multiple modules can be synchronized to build higher-channel-count strain and bridge measurement systems.<\/p>\n<p>Visit the <a href=\"https:\/\/pxisource.com\/ru\/product-category\/%d0%bd%d0%b8\/pxi-%d1%81%d0%b8%d1%81%d1%82%d0%b5%d0%bc%d1%81\/%d0%bc%d0%be%d0%b4%d1%83%d0%bb%d0%b8-pxi\/\">NI PXI Modules category<\/a> to explore related PXI measurement hardware.<\/p>\n<h3>Troubleshooting the PXIe-4330<\/h3>\n<h4>The module is not detected<\/h4>\n<p>Confirm that the PXIe-4330 is installed in a compatible PXI Express slot. Check the chassis controller, PXI Platform Services and NI-DAQmx installation.<\/p>\n<h4>The bridge measurement has a large offset<\/h4>\n<p>Verify the bridge configuration, completion resistance, sensor wiring and initial bridge balance. Check for damaged gauges or incorrect terminal assignments.<\/p>\n<h4>The strain reading has the wrong polarity<\/h4>\n<p>Check the orientation of the active gauge and the AI+ and AI\u2212 connections. Reverse the signal wiring or adjust the software configuration when necessary.<\/p>\n<h4>The excitation voltage is lower than expected<\/h4>\n<p>Confirm that the selected excitation is compatible with the bridge resistance and configuration. Check for excessive cable resistance, short circuits or sensor loading.<\/p>\n<h4>Measurements are noisy or unstable<\/h4>\n<p>Use shielded sensor cables, verify grounding, reduce cable movement and select an appropriate sampling rate. Remote sensing can improve results with long excitation wiring.<\/p>\n<h4>Shunt calibration produces an unexpected result<\/h4>\n<p>Check the selected shunt resistance, bridge completion setting, gauge resistance and wiring. Confirm that the software scaling matches the physical sensor.<\/p>\n<h3>PXIe-4330 Comparison<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u041c\u043e\u0434\u0435\u043b\u044c<\/th>\n<th>\u041a\u0430\u043d\u0430\u043b\u044b<\/th>\n<th>\u0420\u0430\u0437\u0440\u0435\u0448\u0435\u043d\u0438\u0435<\/th>\n<th>Maximum Rate<\/th>\n<th>Primary Use<\/th>\n<\/tr>\n<tr>\n<td>PXIe-4330<\/td>\n<td>8<\/td>\n<td>24 bit<\/td>\n<td>25,6 \u0442\u044b\u0441. \u043e\u0442\u0441\u0447\u0435\u0442\u043e\u0432\/\u0441 \u043d\u0430 \u043a\u0430\u043d\u0430\u043b<\/td>\n<td>General strain and bridge measurements<\/td>\n<\/tr>\n<tr>\n<td>PXIe-4331<\/td>\n<td>8<\/td>\n<td>24 bit<\/td>\n<td>102.4 kS\/s per channel<\/td>\n<td>Higher-speed dynamic bridge measurements<\/td>\n<\/tr>\n<tr>\n<td>PXIe-4339<\/td>\n<td>8<\/td>\n<td>24 bit<\/td>\n<td>25,6 \u0442\u044b\u0441. \u043e\u0442\u0441\u0447\u0435\u0442\u043e\u0432\/\u0441 \u043d\u0430 \u043a\u0430\u043d\u0430\u043b<\/td>\n<td>Modern bridge and strain measurement systems<\/td>\n<\/tr>\n<tr>\n<td>PXIe-4340<\/td>\n<td>4<\/td>\n<td>24 bit<\/td>\n<td>25,6 \u0442\u044b\u0441. \u043e\u0442\u0441\u0447\u0435\u0442\u043e\u0432\/\u0441 \u043d\u0430 \u043a\u0430\u043d\u0430\u043b<\/td>\n<td>LVDT and RVDT sensor measurements<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Recommended Related Products<\/h3>\n<ul>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxie-4331\/\">PXIe-4331<\/a> \u2013 8-channel bridge input module with a higher 102.4 kS\/s sampling rate<\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxie-4339\/\">PXIe-4339<\/a> \u2013 8-channel strain and bridge input module with multiple terminal block options<\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxie-4340\/\">PXIe-4340<\/a> \u2013 dedicated input module for LVDT and RVDT sensors<\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxie-4357\/\">PXIe-4357<\/a> \u2013 high-density module for RTD temperature measurements<\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxie-1092\/\">PXIe-1092<\/a> \u2013 PXI Express chassis for modular measurement systems<\/li>\n<\/ul>\n<h3>Selecting the PXIe-4330<\/h3>\n<p>Choose the PXIe-4330 when an application requires eight simultaneous bridge measurements with integrated excitation, bridge completion, remote sensing and shunt calibration at rates up to 25.6 kS\/s per channel.<\/p>\n<p>If higher sampling speed is required for dynamic strain measurements, consider the PXIe-4331. For LVDT or RVDT sensors, use the PXIe-4340.<\/p>\n<h3>PXIe-4330 vs PXIe-4331<\/h3>\n<p>The PXIe-4330 and PXIe-4331 both provide eight simultaneous, 24-bit bridge input channels with programmable excitation, bridge completion, remote sensing and shunt calibration.<\/p>\n<p>The primary difference is maximum sampling rate. The PXIe-4330 supports up to <strong>25,6 \u0442\u044b\u0441. \u043e\u0442\u0441\u0447\u0435\u0442\u043e\u0432\/\u0441 \u043d\u0430 \u043a\u0430\u043d\u0430\u043b<\/strong>, while the PXIe-4331 supports up to 102.4 kS\/s per channel. The PXIe-4331 is better suited to higher-frequency dynamic measurements.<\/p>\n<h3>Why Choose the PXIe-4330?<\/h3>\n<ul>\n<li>Eight simultaneous 24-bit bridge input channels<\/li>\n<li>Integrated full-, half- and quarter-bridge support<\/li>\n<li>Independent programmable excitation per channel<\/li>\n<li>120 \u03a9, 350 \u03a9 and 1 k\u03a9 bridge completion<\/li>\n<li>Remote sensing for long sensor cables<\/li>\n<li>Internal and external shunt calibration<\/li>\n<li>Front-mount and rack-mount terminal options<\/li>\n<\/ul>\n<h3>Frequently Asked Questions<\/h3>\n<h4>What is the PXIe-4330 used for?<\/h4>\n<p>The PXIe-4330 is used to measure strain gauges, load cells, force sensors, bridge-based pressure transducers and torque sensors.<\/p>\n<h4>How many input channels does it provide?<\/h4>\n<p>The module provides eight simultaneous strain and bridge input channels.<\/p>\n<h4>What is the maximum sampling rate?<\/h4>\n<p>The PXIe-4330 supports sampling rates up to 25.6 kS\/s per channel.<\/p>\n<h4>Which bridge configurations are supported?<\/h4>\n<p>The module supports full-, half- and quarter-bridge configurations.<\/p>\n<h4>Which quarter-bridge resistances are supported?<\/h4>\n<p>Internal completion is available for 120 \u03a9, 350 \u03a9 and 1 k\u03a9 quarter-bridge sensors.<\/p>\n<h4>Does the PXIe-4330 provide sensor excitation?<\/h4>\n<p>Yes. Each channel provides independently programmable balanced excitation from 0.625 V to 10 V.<\/p>\n<h4>Does the PXIe-4330 support shunt calibration?<\/h4>\n<p>Yes. It provides software-selectable internal and external shunt calibration options for individual channels.<\/p>\n<h4>Which terminal block is compatible with the PXIe-4330?<\/h4>\n<p>The TB-4330 front-mount terminal block and RM-24999 rack-mount terminal block are compatible with the PXIe-4330.<\/p>\n<h4>What is the PXIe-4330 part number?<\/h4>\n<p>The standard NI part number for the PXIe-4330 is <strong>781346-01<\/strong>.<\/p>\n<h3>Request a Quote for the PXIe-4330<\/h3>\n<p>Contact us for current availability, lead time and project pricing for the <strong>PXIe-4330 Strain and Bridge Input Module<\/strong>. We can also help confirm compatible terminal blocks, cables, PXI chassis and related sensor measurement modules.<\/p>","protected":false},"excerpt":{"rendered":"<p>\u0414\u0438\u0430\u043f\u0430\u0437\u043e\u043d \u0432\u0445\u043e\u0434\u043d\u043e\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f: \u043e\u0442 -100 \u043c\u0412\/\u0412 \u0434\u043e 100 \u043c\u0412\/\u0412, \u043e\u0442 -25 \u043c\u0412\/\u0412 \u0434\u043e 25 \u043c\u0412\/\u0412<br \/>\nMaximum Sample Rate: 25.6 kS\/s<br \/>\n\u041c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u0435 \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u0434\u0438\u0444\u0444\u0435\u0440\u0435\u043d\u0446\u0438\u0430\u043b\u044c\u043d\u044b\u0445 \u0430\u043d\u0430\u043b\u043e\u0433\u043e\u0432\u044b\u0445 \u0432\u0445\u043e\u0434\u043d\u044b\u0445 \u043a\u0430\u043d\u0430\u043b\u043e\u0432: 8<br \/>\n\u041a\u043e\u043d\u0444\u0438\u0433\u0443\u0440\u0430\u0446\u0438\u0438 \u043c\u043e\u0441\u0442\u0430: -, -, \u2013<br \/>\n\u0421\u043e\u043f\u0440\u043e\u0442\u0438\u0432\u043b\u0435\u043d\u0438\u0435 \u043c\u043e\u0441\u0442\u0430: 1000 \u041e\u043c, 120 \u041e\u043c, 350 \u041e\u043c<\/p>","protected":false},"featured_media":32728,"template":"","meta":{"_acf_changed":false},"product_brand":[18],"product_cat":[667],"product_tag":[],"class_list":["post-32788","product","type-product","status-publish","has-post-thumbnail","product_brand-national-instruments","product_cat-pxi-modules","first","instock","shipping-taxable","purchasable","product-type-simple"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.0 (Yoast SEO v28.1) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>NI PXIe-4330 PXI Strain\/Bridge Input Module 781346-01, In Stock | Project Pricing<\/title>\n<meta name=\"description\" content=\"The PXIe-4330 is an 8-channel, 24-bit strain and bridge input module with 25.6 kS\/s simultaneous sampling, programmable excitation, and shunt calibration.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/pxisource.com\/ru\/product\/pxie-4330\/\" \/>\n<meta property=\"og:locale\" content=\"ru_RU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"PXIe-4330\" \/>\n<meta property=\"og:description\" content=\"The PXIe-4330 is an 8-channel, 24-bit strain and bridge input module with 25.6 kS\/s simultaneous sampling, programmable excitation, and shunt calibration.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/pxisource.com\/ru\/product\/pxie-4330\/\" \/>\n<meta property=\"og:site_name\" content=\"PXI Source\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=61582573040385\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-29T06:47:33+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/05\/PXIe-4330.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"800\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u0426\u0435\u043d\u0430\" \/>\n\t<meta name=\"twitter:data1\" content=\"&#036;6,323.00\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c\" \/>\n\t<meta name=\"twitter:data2\" content=\"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-4330\\\/\",\"url\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-4330\\\/\",\"name\":\"NI PXIe-4330 PXI Strain\\\/Bridge Input Module 781346-01, In Stock | Project Pricing\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-4330\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-4330\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/PXIe-4330.webp\",\"datePublished\":\"2026-05-13T07:44:25+00:00\",\"dateModified\":\"2026-08-29T06:47:33+00:00\",\"description\":\"The PXIe-4330 is an 8-channel, 24-bit strain and bridge input module with 25.6 kS\\\/s simultaneous sampling, programmable excitation, and shunt calibration.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-4330\\\/#breadcrumb\"},\"inLanguage\":\"ru-RU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-4330\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-4330\\\/#primaryimage\",\"url\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/PXIe-4330.webp\",\"contentUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/PXIe-4330.webp\",\"width\":800,\"height\":800,\"caption\":\"PXIe-4330\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-4330\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/pxisource.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u5546\u5e97\",\"item\":\"https:\\\/\\\/pxisource.com\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"PXIe-4330\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\",\"url\":\"https:\\\/\\\/pxisource.com\\\/\",\"name\":\"PXI Systems\",\"description\":\"PXI, PXIe and Modular Test Equipment\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/pxisource.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ru-RU\"}]}<\/script>\n<meta property=\"product:brand\" content=\"National Instruments\" \/>\n<meta property=\"product:price:amount\" content=\"6323.00\" \/>\n<meta property=\"product:price:currency\" content=\"USD\" \/>\n<meta property=\"og:availability\" content=\"instock\" \/>\n<meta property=\"product:availability\" content=\"instock\" \/>\n<meta property=\"product:condition\" content=\"new\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"NI PXIe-4330 PXI Strain\/Bridge Input Module 781346-01, In Stock | Project Pricing","description":"The PXIe-4330 is an 8-channel, 24-bit strain and bridge input module with 25.6 kS\/s simultaneous sampling, programmable excitation, and shunt calibration.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/pxisource.com\/ru\/product\/pxie-4330\/","og_locale":"ru_RU","og_type":"article","og_title":"PXIe-4330","og_description":"The PXIe-4330 is an 8-channel, 24-bit strain and bridge input module with 25.6 kS\/s simultaneous sampling, programmable excitation, and shunt calibration.","og_url":"https:\/\/pxisource.com\/ru\/product\/pxie-4330\/","og_site_name":"PXI Source","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=61582573040385","article_modified_time":"2026-08-29T06:47:33+00:00","og_image":[{"width":800,"height":800,"url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/05\/PXIe-4330.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"\u0426\u0435\u043d\u0430":"&#36;6,323.00","\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c":"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/pxisource.com\/product\/pxie-4330\/","url":"https:\/\/pxisource.com\/product\/pxie-4330\/","name":"NI PXIe-4330 PXI Strain\/Bridge Input Module 781346-01, In Stock | Project Pricing","isPartOf":{"@id":"https:\/\/pxisource.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/pxisource.com\/product\/pxie-4330\/#primaryimage"},"image":{"@id":"https:\/\/pxisource.com\/product\/pxie-4330\/#primaryimage"},"thumbnailUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/05\/PXIe-4330.webp","datePublished":"2026-05-13T07:44:25+00:00","dateModified":"2026-08-29T06:47:33+00:00","description":"The PXIe-4330 is an 8-channel, 24-bit strain and bridge input module with 25.6 kS\/s simultaneous sampling, programmable excitation, and shunt calibration.","breadcrumb":{"@id":"https:\/\/pxisource.com\/product\/pxie-4330\/#breadcrumb"},"inLanguage":"ru-RU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/pxisource.com\/product\/pxie-4330\/"]}]},{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/pxisource.com\/product\/pxie-4330\/#primaryimage","url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/05\/PXIe-4330.webp","contentUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/05\/PXIe-4330.webp","width":800,"height":800,"caption":"PXIe-4330"},{"@type":"BreadcrumbList","@id":"https:\/\/pxisource.com\/product\/pxie-4330\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/pxisource.com\/"},{"@type":"ListItem","position":2,"name":"\u5546\u5e97","item":"https:\/\/pxisource.com\/shop\/"},{"@type":"ListItem","position":3,"name":"PXIe-4330"}]},{"@type":"WebSite","@id":"https:\/\/pxisource.com\/#website","url":"https:\/\/pxisource.com\/","name":"\u0421\u0438\u0441\u0442\u0435\u043c\u044b PXI","description":"PXI, PXIe and Modular Test Equipment","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/pxisource.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ru-RU"}]},"product_brand":"National Instruments","product_price_amount":"6323.00","product_price_currency":"USD","og_availability":"instock","product_availability":"instock","product_condition":"new"},"_links":{"self":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/32788","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":4,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/32788\/revisions"}],"predecessor-version":[{"id":35671,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/32788\/revisions\/35671"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media\/32728"}],"wp:attachment":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media?parent=32788"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_brand?post=32788"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_cat?post=32788"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_tag?post=32788"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}