{"id":32504,"date":"2026-05-07T09:27:45","date_gmt":"2026-05-07T01:27:45","guid":{"rendered":"https:\/\/pxisource.com\/?post_type=product&#038;p=32504"},"modified":"2026-08-29T14:53:22","modified_gmt":"2026-08-29T06:53:22","slug":"pxi-2536","status":"publish","type":"product","link":"https:\/\/pxisource.com\/ru\/product\/pxi-2536\/","title":{"rendered":"PXI-2536"},"content":{"rendered":"<h3>PXI-2536 8\u00d768 High-Density Matrix Switch Module<\/h3>\n<p>\u0417\u0435\u043c\u043b\u044f <strong>PXI-2536<\/strong> is a high-density, one-wire PXI matrix switch module with an <strong>8\u00d768 topology<\/strong> and 544 crosspoints. It is designed for automated routing of low-power DC signals in semiconductor, printed circuit board and electronic device validation systems.<\/p>\n<p>The module uses field-effect transistor relays and supports switching speeds up to <strong>50,000 crosspoints per second<\/strong>. Its solid-state architecture eliminates mechanical contact wear and supports high-throughput production testing.<\/p>\n<h3>Key Features of the PXI-2536<\/h3>\n<ul>\n<li>8\u00d768 one-wire matrix topology<\/li>\n<li>544 independently controlled crosspoints<\/li>\n<li>Field-effect transistor relay technology<\/li>\n<li>Up to 50,000 crosspoint operations per second<\/li>\n<li>12 V maximum DC switching voltage<\/li>\n<li>100 mA maximum switching current<\/li>\n<li>1.2 W maximum switching power per channel<\/li>\n<li>Greater than 1 MHz typical single-crosspoint bandwidth<\/li>\n<li>10 \u00b5V typical offset voltage<\/li>\n<li>Hardware triggering for deterministic scanning<\/li>\n<li>Onboard relay-operation counting<\/li>\n<li>PXI Hybrid bus connector<\/li>\n<li>NI-SWITCH and NI Switch Executive support<\/li>\n<\/ul>\n<h3>PXI-2536 Technical Specifications<\/h3>\n<table>\n<tbody>\n<tr>\n<th>Product Model<\/th>\n<td>PXI-2536<\/td>\n<\/tr>\n<tr>\n<th>Part Number<\/th>\n<td>778572-36<\/td>\n<\/tr>\n<tr>\n<th>Product Type<\/th>\n<td>PXI Matrix Switch Module<\/td>\n<\/tr>\n<tr>\n<th>Matrix Topology<\/th>\n<td>8\u00d768, one-wire<\/td>\n<\/tr>\n<tr>\n<th>Matrix Rows<\/th>\n<td>8<\/td>\n<\/tr>\n<tr>\n<th>Matrix Columns<\/th>\n<td>68<\/td>\n<\/tr>\n<tr>\n<th>Crosspoints<\/th>\n<td>544<\/td>\n<\/tr>\n<tr>\n<th>\u0422\u0438\u043f \u0440\u0435\u043b\u0435<\/th>\n<td>Field-effect transistor<\/td>\n<\/tr>\n<tr>\n<th>Maximum Scan Rate<\/th>\n<td>50,000 crosspoints\/s<\/td>\n<\/tr>\n<tr>\n<th>Typical FET Operating Time<\/th>\n<td>12 \u00b5s<\/td>\n<\/tr>\n<tr>\n<th>Maximum Switching Voltage<\/th>\n<td>12 VDC or 8 VAC<\/td>\n<\/tr>\n<tr>\n<th>Maximum Switching Current<\/th>\n<td>100 mA<\/td>\n<\/tr>\n<tr>\n<th>Maximum Switching Power<\/th>\n<td>1.2 W per channel, resistive<\/td>\n<\/tr>\n<tr>\n<th>Typical Path Resistance<\/th>\n<td>10 \u03a9, row to column<\/td>\n<\/tr>\n<tr>\n<th>Maximum Path Resistance<\/th>\n<td>15.5 \u03a9, row to column<\/td>\n<\/tr>\n<tr>\n<th>Typical Offset Voltage<\/th>\n<td>10 \u00b5V<\/td>\n<\/tr>\n<tr>\n<th>Typical Bandwidth<\/th>\n<td>Greater than 1 MHz for one crosspoint<\/td>\n<\/tr>\n<tr>\n<th>Powered-On Overvoltage Protection<\/th>\n<td>\u00b136 VDC<\/td>\n<\/tr>\n<tr>\n<th>Powered-Off Overvoltage Protection<\/th>\n<td>\u00b140 VDC<\/td>\n<\/tr>\n<tr>\n<th>Front Connectors<\/th>\n<td>4 \u00d7 68-pin VHDCI<\/td>\n<\/tr>\n<tr>\n<th>Bus Connector<\/th>\n<td>PXI Hybrid<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>PXI-2536 Part Number and Accessories<\/h3>\n<table>\n<tbody>\n<tr>\n<th>Item<\/th>\n<th>Part Number<\/th>\n<th>\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435<\/th>\n<\/tr>\n<tr>\n<td>PXI-2536<\/td>\n<td>778572-36<\/td>\n<td>8\u00d768, 544-crosspoint FET matrix switch module<\/td>\n<\/tr>\n<tr>\n<td>TBX-68<\/td>\n<td>777141-01<\/td>\n<td>68-pin male SCSI connector block<\/td>\n<\/tr>\n<tr>\n<td>CB-68LP<\/td>\n<td>777145-01<\/td>\n<td>Low-profile 68-pin connector block<\/td>\n<\/tr>\n<tr>\n<td>CB-68LPR<\/td>\n<td>777145-02<\/td>\n<td>Rack-mountable 68-pin connector block<\/td>\n<\/tr>\n<tr>\n<td>SHC68-C68-S<\/td>\n<td>186380-02<\/td>\n<td>2 m shielded cable for PXI switch connections<\/td>\n<\/tr>\n<tr>\n<td>SHC68-68<\/td>\n<td>191945-01<\/td>\n<td>1 m shielded 68-pin cable<\/td>\n<\/tr>\n<tr>\n<td>SHC68-68<\/td>\n<td>191945-02<\/td>\n<td>2 m shielded 68-pin cable<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Use shielded cables and accessories to maintain the specified electromagnetic compatibility performance. Accessory requirements depend on cable length, connector block location and test fixture design.<\/p>\n<h3>8\u00d768 Matrix Architecture<\/h3>\n<p>The PXI-2536 provides eight rows and 68 columns, creating 544 independently controlled crosspoints. Any row can be connected to one or more columns through software commands or a predefined scan list.<\/p>\n<p>This topology allows up to eight measurement or stimulus paths to access a large number of device-under-test connections without manual cable changes.<\/p>\n<h3>One-Wire Signal Routing<\/h3>\n<p>The module uses a one-wire matrix topology. Each crosspoint switches one signal conductor between a row and a column.<\/p>\n<p>A separate return or ground connection must be provided through the test fixture or system wiring. The PXI-2536 is therefore intended for compatible low-power signals sharing an appropriate reference.<\/p>\n<h3>544 Independently Controlled Crosspoints<\/h3>\n<p>Each of the 544 crosspoints can be controlled independently. Multiple routes can be closed simultaneously to connect several instruments, distribute a common signal or create application-specific switching paths.<\/p>\n<p>Before closing multiple routes, verify that the resulting connections will not short independent sources or exceed the voltage, current and power ratings.<\/p>\n<h3>FET Relay Technology<\/h3>\n<p>The PXI-2536 uses FET relays rather than conventional mechanical contacts. This provides fast switching and eliminates mechanical relay contact wear when the module operates within its specified limits.<\/p>\n<p>FET switching is particularly useful in production systems that execute a large number of repetitive switching operations.<\/p>\n<h3>High-Speed Matrix Scanning<\/h3>\n<p>The PXI-2536 supports switching speeds up to <strong>50,000 crosspoints per second<\/strong>. Its typical FET operation time is approximately 12 \u00b5s.<\/p>\n<p>High-speed scanning can significantly reduce test duration when many device-under-test points must be measured sequentially.<\/p>\n<h3>Hardware-Triggered Operation<\/h3>\n<p>Hardware triggering allows the matrix to advance through a scan list without waiting for individual host-computer commands. This provides more deterministic switching timing.<\/p>\n<p>The switch can be coordinated with a digital multimeter, source measurement unit, digitizer or other PXI instrument to improve automated test throughput.<\/p>\n<h3>Low-Power DC Signal Routing<\/h3>\n<p>The module supports switching voltages up to 12 VDC, currents up to 100 mA and resistive switching power up to 1.2 W per channel.<\/p>\n<p>The PXI-2536 should not be used for high-voltage, high-current or power switching applications. Select a switch module with suitable electromechanical relays when higher ratings are required.<\/p>\n<h3>Path Resistance Considerations<\/h3>\n<p>The typical row-to-column path resistance is approximately 10 \u03a9 and can reach 15.5 \u03a9. This resistance can produce a voltage drop when current flows through the switch path.<\/p>\n<p>The PXI-2536 is best suited to high-impedance measurement instruments and other low-current signal-routing applications.<\/p>\n<h3>Signal Bandwidth and Crosstalk<\/h3>\n<p>A single crosspoint provides a typical bandwidth greater than 1 MHz in a 50 \u03a9 test configuration. Actual bandwidth depends on cable length, fixture design, connected instruments and the number of active routes.<\/p>\n<p>Unused routes should remain open, and shielded cabling should be used to reduce crosstalk between sensitive signals.<\/p>\n<h3>Onboard Relay Counting<\/h3>\n<p>The module includes onboard relay-operation counting for monitoring switch usage. Operation counts can help confirm test execution, identify heavily used routes and maintain system records.<\/p>\n<p>Although FET switches do not have mechanical contacts, usage tracking remains useful in production and validation systems.<\/p>\n<h3>\u0422\u0438\u043f\u0438\u0447\u043d\u044b\u0435 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f<\/h3>\n<ul>\n<li>Semiconductor device validation<\/li>\n<li>Printed circuit board testing<\/li>\n<li>Integrated circuit production testing<\/li>\n<li>Continuity and resistance testing<\/li>\n<li>Low-power DC signal routing<\/li>\n<li>Electronic component characterization<\/li>\n<li>Measurement instrument sharing<\/li>\n<li>Automated functional testing<\/li>\n<li>Design verification testing<\/li>\n<li>Production test fixture automation<\/li>\n<\/ul>\n<h3>\u0421\u0438\u0441\u0442\u0435\u043c\u044b \u0442\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f \u043f\u043e\u043b\u0443\u043f\u0440\u043e\u0432\u043e\u0434\u043d\u0438\u043a\u043e\u0432<\/h3>\n<p>The 8\u00d768 topology allows several measurement or stimulus paths to connect to a large number of semiconductor pins. Fast FET switching helps reduce the time required for repetitive validation sequences.<\/p>\n<p>The module can route suitable low-power DC signals from source measurement units, digital multimeters and other automated test instruments.<\/p>\n<h3>PCB Functional Testing<\/h3>\n<p>In PCB testing, the PXI-2536 can connect multiple instruments to selected nodes in a test fixture. Software selects the required crosspoints for each stage of the functional test.<\/p>\n<p>This reduces manual wiring and allows the same instrumentation to be reused across many test points.<\/p>\n<h3>NI-SWITCH Driver Support<\/h3>\n<p>The PXI-2536 is controlled through the NI-SWITCH driver. The driver provides functions for connecting routes, disconnecting routes, creating scan lists, processing triggers and monitoring switch operations.<\/p>\n<p>Automated applications can be developed using LabVIEW, C, C#, Python and other supported programming environments.<\/p>\n<h3>NI Switch Executive Integration<\/h3>\n<p>NI Switch Executive provides route-based management for complex switching systems. Developers can assign meaningful names to signal routes instead of controlling individual crosspoints throughout the test code.<\/p>\n<p>This approach simplifies system maintenance and helps reduce routing errors in automated test applications containing multiple switch modules.<\/p>\n<h3>\u0418\u043d\u0442\u0435\u0433\u0440\u0430\u0446\u0438\u044f \u0441\u0438\u0441\u0442\u0435\u043c PXI<\/h3>\n<p>The PXI-2536 uses a PXI Hybrid connector and requires a compatible PXI or PXI Express hybrid chassis slot. The controller and software environment must support the NI-SWITCH driver.<\/p>\n<p>Visit the <a href=\"https:\/\/pxisource.com\/ru\/product-category\/%d0%bd%d0%b8\/pxi-%d1%81%d0%b8%d1%81%d1%82%d0%b5%d0%bc%d1%81\/%d0%bc%d0%be%d0%b4%d1%83%d0%bb%d0%b8-pxi\/\">NI PXI Modules category<\/a> to explore related switch and measurement hardware.<\/p>\n<h3>Troubleshooting the PXI-2536<\/h3>\n<h4>The module is not detected<\/h4>\n<p>Confirm that the PXI-2536 is installed in a compatible PXI Hybrid slot. Check the chassis controller, PXI Platform Services and NI-SWITCH driver installation.<\/p>\n<h4>A configured route does not close<\/h4>\n<p>Verify the row and column names, matrix topology and route syntax. Check whether the requested route conflicts with an existing connection.<\/p>\n<h4>The measured signal has an unexpected voltage drop<\/h4>\n<p>Include the module\u2019s path resistance in the circuit calculation. Check the signal current, cable resistance, connector contacts and fixture wiring.<\/p>\n<h4>The signal appears on the wrong test point<\/h4>\n<p>Verify the connector pinout, cable orientation, column assignment and fixture wiring. Test each route for continuity before connecting sensitive equipment.<\/p>\n<h4>A floating measurement source produces incorrect readings<\/h4>\n<p>Ensure that the floating source has an appropriate reference to chassis or earth ground. An unsuitable floating connection can interact with the FET protection circuitry and produce incorrect results.<\/p>\n<h4>Automated scanning is slower than expected<\/h4>\n<p>Review instrument measurement time, software delays, trigger configuration and scan sequencing. Hardware triggering can reduce host-command overhead.<\/p>\n<h3>PXI-2536 Comparison<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u041c\u043e\u0434\u0435\u043b\u044c<\/th>\n<th>Topology<\/th>\n<th>Crosspoints<\/th>\n<th>\u0422\u0438\u043f \u0440\u0435\u043b\u0435<\/th>\n<th>Primary Use<\/th>\n<\/tr>\n<tr>\n<td>PXI-2536<\/td>\n<td>8\u00d768<\/td>\n<td>544<\/td>\n<td>FET<\/td>\n<td>Eight-row, low-power DC routing<\/td>\n<\/tr>\n<tr>\n<td>PXI-2535<\/td>\n<td>4\u00d7136<\/td>\n<td>544<\/td>\n<td>FET<\/td>\n<td>Fewer rows with more columns<\/td>\n<\/tr>\n<tr>\n<td>PXI-2534<\/td>\n<td>8\u00d732<\/td>\n<td>256<\/td>\n<td>Solid-state<\/td>\n<td>Lower-density eight-row routing<\/td>\n<\/tr>\n<tr>\n<td>PXI-2533<\/td>\n<td>4\u00d764<\/td>\n<td>256<\/td>\n<td>Solid-state<\/td>\n<td>Four-row matrix applications<\/td>\n<\/tr>\n<tr>\n<td>PXI-2531<\/td>\n<td>Multiple configurations<\/td>\n<td>Up to 512<\/td>\n<td>Reed relay<\/td>\n<td>Flexible signal-routing topologies<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Recommended Related Products<\/h3>\n<ul>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxi-2535\/\">PXI-2535<\/a> \u2013 4\u00d7136 FET matrix switch with the same 544-crosspoint capacity<\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxi-2534\/\">PXI-2534<\/a> \u2013 8\u00d732 solid-state matrix switch for lower channel-count systems<\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxi-2533\/\">PXI-2533<\/a> \u2013 4\u00d764 matrix switch for automated signal routing<\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxi-2531\/\">PXI-2531<\/a> \u2013 configurable reed-relay matrix switch for flexible topologies<\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxie-4080\/\">PXIe-4080<\/a> \u2013 digital multimeter for automated voltage, current and resistance measurements<\/li>\n<\/ul>\n<h3>Selecting the PXI-2536<\/h3>\n<p>Choose the PXI-2536 when the test system requires up to eight matrix rows to access 68 columns and all routed signals remain within the module\u2019s low-power DC ratings.<\/p>\n<p>If fewer instrument rows and more device-under-test columns are required, consider the PXI-2535. Select a higher-rated electromechanical or reed-relay module when routing higher voltage, current or power.<\/p>\n<h3>PXI-2536 vs PXI-2535<\/h3>\n<p>The PXI-2536 and PXI-2535 both provide 544 FET crosspoints, switching speeds up to 50,000 crosspoints per second and low-power DC signal routing.<\/p>\n<p>The primary difference is topology. The PXI-2536 uses an <strong>8\u00d768 matrix<\/strong>, while the PXI-2535 uses a 4\u00d7136 matrix. The correct model depends on the required number of instrument rows and device-under-test columns.<\/p>\n<h3>Why Choose the PXI-2536?<\/h3>\n<ul>\n<li>544 crosspoints in one PXI module<\/li>\n<li>8\u00d768 topology for multiple instrument paths<\/li>\n<li>Fast FET switching up to 50,000 crosspoints\/s<\/li>\n<li>No mechanical relay contact wear<\/li>\n<li>Hardware-triggered deterministic scanning<\/li>\n<li>Low offset voltage for precision DC routing<\/li>\n<li>NI-SWITCH and Switch Executive integration<\/li>\n<\/ul>\n<h3>Frequently Asked Questions<\/h3>\n<h4>What is the PXI-2536 used for?<\/h4>\n<p>The PXI-2536 routes low-power DC signals between multiple instruments and device-under-test points in semiconductor, PCB and automated production test systems.<\/p>\n<h4>What is the PXI-2536 matrix configuration?<\/h4>\n<p>It provides an 8\u00d768 one-wire matrix with 544 crosspoints.<\/p>\n<h4>Which relay technology does it use?<\/h4>\n<p>The PXI-2536 uses field-effect transistor relays for fast solid-state switching without mechanical contact wear.<\/p>\n<h4>What is the maximum switching speed?<\/h4>\n<p>The module supports switching rates up to 50,000 crosspoints per second.<\/p>\n<h4>What voltage and current can it switch?<\/h4>\n<p>The PXI-2536 supports up to 12 VDC, 100 mA and 1.2 W of resistive switching power per channel.<\/p>\n<h4>Can the PXI-2536 switch high-power loads?<\/h4>\n<p>No. It is designed for low-power signal routing and should not be used for high-voltage or high-current loads.<\/p>\n<h4>Does the PXI-2536 support hardware triggering?<\/h4>\n<p>Yes. Hardware triggering enables deterministic scanning and synchronization with compatible test instruments.<\/p>\n<h4>What is the difference between the PXI-2536 and PXI-2535?<\/h4>\n<p>The PXI-2536 uses an 8\u00d768 topology, while the PXI-2535 uses a 4\u00d7136 topology. Both provide 544 FET crosspoints.<\/p>\n<h4>What is the PXI-2536 part number?<\/h4>\n<p>The standard NI part number for the PXI-2536 is <strong>778572-36<\/strong>.<\/p>\n<h3>Request a Quote for the PXI-2536<\/h3>\n<p>Contact us for current availability, lead time and project pricing for the <strong>PXI-2536 Matrix Switch Module<\/strong>. We can also help confirm compatible cables, connector blocks, PXI chassis and related switch modules for your test system.<\/p>","protected":false},"excerpt":{"rendered":"<p>Crosspoints: 544<br \/>\nScan Rate: 50000 cycles\/s<br \/>\n\u0428\u0438\u043d\u043d\u044b\u0439 \u0441\u043e\u0435\u0434\u0438\u043d\u0438\u0442\u0435\u043b\u044c: PXI Hybrid<br \/>\nMaximum Switching Current DC: 100 mA<br \/>\nMaximum Switching Voltage DC: 12 V<br \/>\n\u041a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u0441\u0442\u0440\u043e\u043a: 8<br \/>\n\u0422\u0438\u043f \u0440\u0435\u043b\u0435: \u041f\u043e\u043b\u0435\u0432\u043e\u0439 \u0442\u0440\u0430\u043d\u0437\u0438\u0441\u0442\u043e\u0440<br \/>\nSwitch Bandwidth: 1 MHz<br \/>\n\u0420\u0435\u0436\u0438\u043c (n-\u043f\u0440\u043e\u0432\u043e\u0434\u043d\u043e\u0439): 1-\u043f\u0440\u043e\u0432\u043e\u0434\u043d\u043e\u0439<br \/>\nNumber of Banks: 0<br \/>\nNumber of Columns: 68<\/p>","protected":false},"featured_media":31182,"template":"","meta":{"_acf_changed":false},"product_brand":[18],"product_cat":[725],"product_tag":[],"class_list":["post-32504","product","type-product","status-publish","has-post-thumbnail","product_brand-national-instruments","product_cat-pxi-switches","first","instock","shipping-taxable","purchasable","product-type-simple"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.0 (Yoast SEO v28.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>NI PXI-2536 PXI Matrix Switch Module 778572-36, In Stock | Project Pricing<\/title>\n<meta name=\"description\" content=\"The PXI-2536 is a high-density 8\u00d768, 544-crosspoint FET matrix switch for routing low-power DC signals at speeds up to 50,000 crosspoints\/s.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/pxisource.com\/ru\/product\/pxi-2536\/\" \/>\n<meta property=\"og:locale\" content=\"ru_RU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"PXI-2536\" \/>\n<meta property=\"og:description\" content=\"The PXI-2536 is a high-density 8\u00d768, 544-crosspoint FET matrix switch for routing low-power DC signals at speeds up to 50,000 crosspoints\/s.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/pxisource.com\/ru\/product\/pxi-2536\/\" \/>\n<meta property=\"og:site_name\" content=\"PXI Source\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=61582573040385\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-29T06:53:22+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PXI-2536\u5b9e\u56fe.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"800\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u0426\u0435\u043d\u0430\" \/>\n\t<meta name=\"twitter:data1\" content=\"&#036;7,822.00\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c\" \/>\n\t<meta name=\"twitter:data2\" content=\"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxi-2536\\\/\",\"url\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxi-2536\\\/\",\"name\":\"NI PXI-2536 PXI Matrix Switch Module 778572-36, In Stock | Project Pricing\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxi-2536\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxi-2536\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/PXI-2536\u5b9e\u56fe.webp\",\"datePublished\":\"2026-05-07T01:27:45+00:00\",\"dateModified\":\"2026-08-29T06:53:22+00:00\",\"description\":\"The PXI-2536 is a high-density 8\u00d768, 544-crosspoint FET matrix switch for routing low-power DC signals at speeds up to 50,000 crosspoints\\\/s.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxi-2536\\\/#breadcrumb\"},\"inLanguage\":\"ru-RU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/pxisource.com\\\/product\\\/pxi-2536\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxi-2536\\\/#primaryimage\",\"url\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/PXI-2536\u5b9e\u56fe.webp\",\"contentUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/PXI-2536\u5b9e\u56fe.webp\",\"width\":800,\"height\":800,\"caption\":\"PXI-2536\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxi-2536\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/pxisource.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\\\/\\\/pxisource.com\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"PXI-2536\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\",\"url\":\"https:\\\/\\\/pxisource.com\\\/\",\"name\":\"PXI Systems\",\"description\":\"NI PXI, PXIe Modular Test Instrument Supplier\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/pxisource.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ru-RU\"}]}<\/script>\n<meta property=\"product:brand\" content=\"National Instruments\" \/>\n<meta property=\"product:price:amount\" content=\"7822.00\" \/>\n<meta property=\"product:price:currency\" content=\"USD\" \/>\n<meta property=\"og:availability\" content=\"instock\" \/>\n<meta property=\"product:availability\" content=\"instock\" \/>\n<meta property=\"product:condition\" content=\"new\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"NI PXI-2536 PXI Matrix Switch Module 778572-36, In Stock | Project Pricing","description":"The PXI-2536 is a high-density 8\u00d768, 544-crosspoint FET matrix switch for routing low-power DC signals at speeds up to 50,000 crosspoints\/s.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/pxisource.com\/ru\/product\/pxi-2536\/","og_locale":"ru_RU","og_type":"article","og_title":"PXI-2536","og_description":"The PXI-2536 is a high-density 8\u00d768, 544-crosspoint FET matrix switch for routing low-power DC signals at speeds up to 50,000 crosspoints\/s.","og_url":"https:\/\/pxisource.com\/ru\/product\/pxi-2536\/","og_site_name":"PXI Source","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=61582573040385","article_modified_time":"2026-08-29T06:53:22+00:00","og_image":[{"width":800,"height":800,"url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PXI-2536\u5b9e\u56fe.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"\u0426\u0435\u043d\u0430":"&#36;7,822.00","\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c":"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/pxisource.com\/product\/pxi-2536\/","url":"https:\/\/pxisource.com\/product\/pxi-2536\/","name":"NI PXI-2536 PXI Matrix Switch Module 778572-36, In Stock | Project Pricing","isPartOf":{"@id":"https:\/\/pxisource.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/pxisource.com\/product\/pxi-2536\/#primaryimage"},"image":{"@id":"https:\/\/pxisource.com\/product\/pxi-2536\/#primaryimage"},"thumbnailUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PXI-2536\u5b9e\u56fe.webp","datePublished":"2026-05-07T01:27:45+00:00","dateModified":"2026-08-29T06:53:22+00:00","description":"The PXI-2536 is a high-density 8\u00d768, 544-crosspoint FET matrix switch for routing low-power DC signals at speeds up to 50,000 crosspoints\/s.","breadcrumb":{"@id":"https:\/\/pxisource.com\/product\/pxi-2536\/#breadcrumb"},"inLanguage":"ru-RU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/pxisource.com\/product\/pxi-2536\/"]}]},{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/pxisource.com\/product\/pxi-2536\/#primaryimage","url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PXI-2536\u5b9e\u56fe.webp","contentUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PXI-2536\u5b9e\u56fe.webp","width":800,"height":800,"caption":"PXI-2536"},{"@type":"BreadcrumbList","@id":"https:\/\/pxisource.com\/product\/pxi-2536\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/pxisource.com\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/pxisource.com\/shop\/"},{"@type":"ListItem","position":3,"name":"PXI-2536"}]},{"@type":"WebSite","@id":"https:\/\/pxisource.com\/#website","url":"https:\/\/pxisource.com\/","name":"\u0421\u0438\u0441\u0442\u0435\u043c\u044b PXI","description":"NI PXI, PXIe Modular Test Instrument Supplier","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/pxisource.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ru-RU"}]},"product_brand":"National Instruments","product_price_amount":"7822.00","product_price_currency":"USD","og_availability":"instock","product_availability":"instock","product_condition":"new"},"_links":{"self":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/32504","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":3,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/32504\/revisions"}],"predecessor-version":[{"id":35677,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/32504\/revisions\/35677"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media\/31182"}],"wp:attachment":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media?parent=32504"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_brand?post=32504"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_cat?post=32504"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_tag?post=32504"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}