{"id":32430,"date":"2026-04-29T09:25:43","date_gmt":"2026-04-29T01:25:43","guid":{"rendered":"https:\/\/pxisource.com\/?post_type=product&#038;p=32430"},"modified":"2026-08-28T17:27:04","modified_gmt":"2026-08-28T09:27:04","slug":"pxie-4142","status":"publish","type":"product","link":"https:\/\/pxisource.com\/ru\/product\/pxie-4142\/","title":{"rendered":"PXIe-4142"},"content":{"rendered":"<p>\u0417\u0435\u043c\u043b\u044f <strong>PXIe-4142<\/strong> is a four-channel source measure unit designed for semiconductor characterization, high-pin-count device testing and automated electronic validation. It combines programmable voltage and current sourcing with precision measurements in a single-slot <a href=\"https:\/\/pxisource.com\/ru\/product-category\/%d0%bd%d0%b8\/pxi-%d1%81%d0%b8%d1%81%d1%82%d0%b5%d0%bc%d1%81\/%d0%bc%d0%be%d0%b4%d1%83%d0%bb%d0%b8-pxi\/\">PXI Express module<\/a>.<\/p>\n<p>Each channel supports four-quadrant operation, a \u00b124 V voltage range and current up to \u00b1150 mA. With integrated four-wire remote sensing, current sensitivity down to 100 pA, continuous measurements up to 600 kS\/s per channel and hardware-timed sequencing, the PXIe-4142 can accelerate I-V characterization and production testing.<\/p>\n<h3>Key Features of the PXIe-4142<\/h3>\n<ul>\n<li>Four programmable SMU channels<\/li>\n<li>Four-quadrant source and sink operation<\/li>\n<li>\u00b124 V voltage range per channel<\/li>\n<li>Up to \u00b1150 mA current per channel<\/li>\n<li>3.6 W maximum source or sink power per channel<\/li>\n<li>Current ranges from \u00b110 \u00b5A to \u00b1150 mA<\/li>\n<li>Current sensitivity down to 100 pA<\/li>\n<li>Maximum continuous measurement rate of 600 kS\/s per channel<\/li>\n<li>Maximum source update rate of 100 kS\/s per channel<\/li>\n<li>Integrated four-wire remote sensing<\/li>\n<li>Guard connections for low-current measurements<\/li>\n<li>Slow, normal and fast transient-response modes<\/li>\n<li>Hardware sequencing and PXI triggering<\/li>\n<li>Channels isolated from earth ground<\/li>\n<li>Single-slot 3U PXI Express form factor<\/li>\n<\/ul>\n<h3>PXIe-4142 Technical Specifications<\/h3>\n<table>\n<tbody>\n<tr>\n<th>Product Model<\/th>\n<td>PXIe-4142<\/td>\n<\/tr>\n<tr>\n<th>Part Number<\/th>\n<td>782430-01<\/td>\n<\/tr>\n<tr>\n<th>Product Type<\/th>\n<td>PXI Source Measure Unit<\/td>\n<\/tr>\n<tr>\n<th>Number of SMU Channels<\/th>\n<td>4<\/td>\n<\/tr>\n<tr>\n<th>Operating Quadrants<\/th>\n<td>Four-quadrant source and sink operation<\/td>\n<\/tr>\n<tr>\n<th>Voltage Range<\/th>\n<td>-24 V to +24 V<\/td>\n<\/tr>\n<tr>\n<th>\u041c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a<\/th>\n<td>\u00b1150 mA per channel<\/td>\n<\/tr>\n<tr>\n<th>Available Current Ranges<\/th>\n<td>10 \u00b5A, 100 \u00b5A, 1 mA, 10 mA and 150 mA<\/td>\n<\/tr>\n<tr>\n<th>Current Sensitivity<\/th>\n<td>100 pA<\/td>\n<\/tr>\n<tr>\n<th>Maximum Source Power<\/th>\n<td>3.6 W per channel<\/td>\n<\/tr>\n<tr>\n<th>Maximum Sink Power<\/th>\n<td>3.6 W per channel<\/td>\n<\/tr>\n<tr>\n<th>Maximum Module Sinking Power<\/th>\n<td>6 W total<\/td>\n<\/tr>\n<tr>\n<th>Voltage Resolution and Noise<\/th>\n<td>200 \u00b5V on the 24 V range<\/td>\n<\/tr>\n<tr>\n<th>Voltage Accuracy<\/th>\n<td>\u00b1(0.1% of reading + 10 mV)<\/td>\n<\/tr>\n<tr>\n<th>10 \u00b5A Range Resolution and Noise<\/th>\n<td>100 pA<\/td>\n<\/tr>\n<tr>\n<th>150 mA Range Resolution and Noise<\/th>\n<td>1.5 \u00b5A<\/td>\n<\/tr>\n<tr>\n<th>Maximum Continuous Measurement Rate<\/th>\n<td>600,000 samples\/s per channel<\/td>\n<\/tr>\n<tr>\n<th>Maximum Source Update Rate<\/th>\n<td>100,000 updates\/s per channel for supported sequences<\/td>\n<\/tr>\n<tr>\n<th>Remote Sense<\/th>\n<td>Four-wire remote sensing on every channel<\/td>\n<\/tr>\n<tr>\n<th>Maximum Remote-Sense Lead Drop<\/th>\n<td>1 V per lead<\/td>\n<\/tr>\n<tr>\n<th>Typical Settling Time<\/th>\n<td>Less than 100 \u00b5s<\/td>\n<\/tr>\n<tr>\n<th>Typical Transient Response<\/th>\n<td>Less than 100 \u00b5s<\/td>\n<\/tr>\n<tr>\n<th>SourceAdapt<\/th>\n<td>No<\/td>\n<\/tr>\n<tr>\n<th>Transient Response Modes<\/th>\n<td>Slow, normal and fast<\/td>\n<\/tr>\n<tr>\n<th>Channel Isolation<\/th>\n<td>Isolated from earth ground; channels share a common LO<\/td>\n<\/tr>\n<tr>\n<th>Channel-to-Ground Isolation<\/th>\n<td>60 VDC, CAT I<\/td>\n<\/tr>\n<tr>\n<th>Front Connector<\/th>\n<td>25-position male D-SUB<\/td>\n<\/tr>\n<tr>\n<th>Form Factor<\/th>\n<td>3U, single-slot PXI Express module<\/td>\n<\/tr>\n<tr>\n<th>Dimensions<\/th>\n<td>2.0 cm \u00d7 13.0 cm \u00d7 21.6 cm<\/td>\n<\/tr>\n<tr>\n<th>Weight<\/th>\n<td>412 g (14.53 oz)<\/td>\n<\/tr>\n<tr>\n<th>Recommended Calibration Interval<\/th>\n<td>1 year<\/td>\n<\/tr>\n<tr>\n<th>Operating Temperature<\/th>\n<td>0\u00b0C to 55\u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Storage Temperature<\/th>\n<td>-40\u00b0C to 70\u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>PXIe-4142 Part Number and Configuration<\/h3>\n<table>\n<thead>\n<tr>\n<th>Part Number<\/th>\n<th>\u041a\u0430\u043d\u0430\u043b\u044b<\/th>\n<th>Voltage Range<\/th>\n<th>\u041c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a<\/th>\n<th>Current Sensitivity<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>782430-01<\/td>\n<td>4<\/td>\n<td>\u00b124 V<\/td>\n<td>\u00b1150 mA<\/td>\n<td>100 pA<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The standard package includes the PXIe-4142 module, a PXIe-4140 terminal block pinout overlay, a 25-pin female D-SUB to 25-pin spring-terminal block and safety, environmental and regulatory documentation.<\/p>\n<h3>Four-Channel SMU Architecture<\/h3>\n<p>The PXIe-4142 integrates four source measure unit channels into one PXI Express slot. Each channel can independently source voltage or current, apply a compliance limit and measure the resulting electrical response.<\/p>\n<p>This architecture can replace multiple programmable power supplies, electronic loads and digital multimeters in automated semiconductor and component test systems.<\/p>\n<h3>Four-Quadrant Operation<\/h3>\n<p>Each channel can source or sink positive and negative voltage and current. Four-quadrant operation enables the PXIe-4142 to power a device, sweep its I-V curve and absorb limited returned energy within the module\u2019s specified operating envelope.<\/p>\n<p>The module can operate as a programmable voltage source, current source or limited electronic load, depending on the selected source function and compliance settings.<\/p>\n<h3>\u00b124 V and \u00b1150 mA Capability<\/h3>\n<p>Every channel supports voltages from -24 V to +24 V and current up to \u00b1150 mA. The wider voltage range makes the PXIe-4142 suitable for devices requiring higher test voltages than lower-voltage members of the PXIe-414x family.<\/p>\n<p>Maximum DC power is 3.6 W per channel. The complete voltage-current operating point must remain within this power limit, so maximum voltage and maximum current cannot always be applied simultaneously.<\/p>\n<h3>Source and Sink Power Limits<\/h3>\n<p>Each channel can source or sink up to 3.6 W, but total module sinking power is limited to 6 W. When several channels absorb power simultaneously, their combined sinking power must remain below this module-level limit.<\/p>\n<p>Test sequences should be designed to account for both individual channel limits and the total power handled by the module.<\/p>\n<h3>Multiple Current Ranges<\/h3>\n<p>The PXIe-4142 provides 10 \u00b5A, 100 \u00b5A, 1 mA, 10 mA and 150 mA ranges. These ranges allow the same module to measure low leakage currents and higher device operating currents.<\/p>\n<p>Selecting the lowest current range that safely covers the expected DUT current generally provides the best measurement resolution.<\/p>\n<h3>100 pA Current Sensitivity<\/h3>\n<p>On the 10 \u00b5A range, the PXIe-4142 provides resolution and noise down to 100 pA under the specified measurement conditions. This supports leakage, standby-current and low-power operating-state measurements.<\/p>\n<p>Measurement quality at low current levels depends on fixture cleanliness, cable guarding, shielding, aperture time, grounding and environmental stability.<\/p>\n<h3>600 kS\/s Measurement Rate<\/h3>\n<p>The PXIe-4142 can continuously transfer voltage and current measurements to the host at rates up to 600 kS\/s per channel. This high-speed measurement capability helps capture startup events, transient current changes and rapid DUT responses.<\/p>\n<p>The effective rate depends on the selected aperture time, source delay, hardware sequence and load settling time.<\/p>\n<h3>High-Speed Hardware Sequencing<\/h3>\n<p>The PXIe-4142 supports source updates at up to 100 kS\/s per channel for compatible sequences containing fewer than 300 steps per iteration. Longer sequences support up to 100 kS\/s per board.<\/p>\n<p>Hardware sequencing allows the module to step through programmed voltage or current levels without a separate host command for every point, reducing software overhead and improving determinism.<\/p>\n<h3>Four-Wire Remote Sensing<\/h3>\n<p>Integrated four-wire remote sensing measures voltage directly at the device-under-test terminals. It compensates for voltage drop across power cables, switches, connectors and test fixtures.<\/p>\n<p>The module supports up to 1 V of remote-sense lead drop per lead. Sense conductors should be connected as close as practical to the DUT terminals.<\/p>\n<h3>Guard Connections<\/h3>\n<p>The PXIe-4142 provides guard connections that can reduce leakage current and parasitic capacitance in low-current test fixtures and cables. Guarding is valuable when measuring currents near the lower end of the module\u2019s measurement capability.<\/p>\n<p>The guard connection must be implemented according to NI wiring guidance and should not be treated as a protective earth connection.<\/p>\n<h3>Shared Common LO Configuration<\/h3>\n<p>The four channels are isolated from earth ground but share a common LO reference. They are not independently isolated from one another.<\/p>\n<p>Before connecting multiple DUT rails, verify that the circuits can safely share the same low reference. Unintended ground paths may cause measurement errors or interfere with channel operation.<\/p>\n<h3>Transient Response Settings<\/h3>\n<p>The PXIe-4142 provides predefined slow, normal and fast transient-response modes. These settings help balance response speed and stability for different load capacitances.<\/p>\n<p>The module does not support fully customizable SourceAdapt tuning. The newer PXIe-4143 should be considered when user-programmable transient-response control is required.<\/p>\n<h3>Hardware Timing and Triggering<\/h3>\n<p>The module supports start, source, sequence-advance and measurement triggers through PXI trigger lines 0 through 7. It can also export source-complete, measure-complete and sequence-related events.<\/p>\n<p>This allows the PXIe-4142 to synchronize with switches, digital pattern instruments, digitizers and other PXI SMUs in automated test sequences.<\/p>\n<h3>\u0422\u0438\u043f\u0438\u0447\u043d\u044b\u0435 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f<\/h3>\n<ul>\n<li>\u0425\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0437\u0430\u0446\u0438\u044f \u043f\u043e\u043b\u0443\u043f\u0440\u043e\u0432\u043e\u0434\u043d\u0438\u043a\u043e\u0432\u044b\u0445 \u043f\u0440\u0438\u0431\u043e\u0440\u043e\u0432<\/li>\n<li>Mixed-signal IC production testing<\/li>\n<li>Power management IC testing<\/li>\n<li>Analog IC validation<\/li>\n<li>Leakage-current measurement<\/li>\n<li>Rapid I-V curve generation<\/li>\n<li>Multirail device power sequencing<\/li>\n<li>MEMS and sensor testing<\/li>\n<li>Protection circuit testing<\/li>\n<li>High-pin-count automated testing<\/li>\n<\/ul>\n<h3>Software Compatibility<\/h3>\n<p>The PXIe-4142 is controlled using the NI-DCPower instrument driver. NI-DCPower provides APIs for voltage and current sourcing, compliance limits, measurements, range selection, remote sensing, triggering and sequencing.<\/p>\n<p>InstrumentStudio can be used for interactive configuration and measurements. Automated test systems can be developed using LabVIEW, LabWindows\/CVI, supported .NET environments and NI TestStand.<\/p>\n<h3>PXI Express System Integration<\/h3>\n<p>The PXIe-4142 occupies one 3U PXI Express or compatible CompactPCI Express slot. It draws power directly from the PXI Express chassis and does not require a separate auxiliary power supply.<\/p>\n<p>The selected chassis must provide sufficient power and cooling. When adjustable chassis fan settings are available, use the fan configuration required by the official specifications.<\/p>\n<h3>PXIe-4142 Connection Guidance<\/h3>\n<ul>\n<li>Power off the chassis before installing or removing the module.<\/li>\n<li>Use the supplied terminal block and pinout overlay.<\/li>\n<li>Confirm the shared common LO arrangement before wiring the DUT.<\/li>\n<li>Program safe voltage and current compliance limits.<\/li>\n<li>Use remote sensing when lead resistance affects DUT voltage.<\/li>\n<li>Use guard connections for sensitive low-current measurements.<\/li>\n<li>Allow at least 30 minutes of warm-up for precision testing.<\/li>\n<li>Perform self-calibration according to the test requirements.<\/li>\n<\/ul>\n<h3>PXIe-4142 Troubleshooting<\/h3>\n<h4>A channel enters compliance unexpectedly<\/h4>\n<p>Check the programmed voltage and current limits, DUT resistance and fixture wiring. Incorrect sense connections or excessive lead resistance can also cause unexpected compliance behavior.<\/p>\n<h4>The voltage at the DUT is lower than programmed<\/h4>\n<p>Enable four-wire remote sensing and connect the sense terminals directly to the DUT. Confirm that voltage drop does not exceed 1 V per lead.<\/p>\n<h4>Low-current readings are unstable<\/h4>\n<p>Select the smallest suitable current range, increase the aperture time and check the fixture for leakage or contamination. Use guarding and shield sensitive connections from interference.<\/p>\n<h4>The output oscillates with a capacitive load<\/h4>\n<p>Select the slow or normal transient-response setting. The fast mode may be unstable with certain load capacitances.<\/p>\n<h4>Multiple channels interfere with one another<\/h4>\n<p>Remember that the four channels share a common LO. Check the DUT and fixture for conflicting reference potentials or unintended ground paths.<\/p>\n<h4>The module overheats or reports a protection error<\/h4>\n<p>Verify chassis airflow and fan speed. Reduce simultaneous source or sink power and confirm that total module sinking power remains below 6 W.<\/p>\n<h3>PXIe-4142 Compared with Related SMUs<\/h3>\n<table>\n<thead>\n<tr>\n<th>\u041c\u043e\u0434\u0435\u043b\u044c<\/th>\n<th>\u041a\u0430\u043d\u0430\u043b\u044b<\/th>\n<th>Voltage Range<\/th>\n<th>\u041c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a<\/th>\n<th>SourceAdapt<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>PXIe-4142<\/td>\n<td>4<\/td>\n<td>\u00b124 V<\/td>\n<td>\u00b1150 mA<\/td>\n<td>No<\/td>\n<\/tr>\n<tr>\n<td>PXIe-4143<\/td>\n<td>4<\/td>\n<td>\u00b124 V<\/td>\n<td>\u00b1150 mA<\/td>\n<td>\u0414\u0430<\/td>\n<\/tr>\n<tr>\n<td>PXIe-4144<\/td>\n<td>4<\/td>\n<td>\u00b16 V<\/td>\n<td>\u00b1500 mA<\/td>\n<td>No<\/td>\n<\/tr>\n<tr>\n<td>PXIe-4141<\/td>\n<td>4<\/td>\n<td>\u00b110 V<\/td>\n<td>\u00b1100 mA<\/td>\n<td>\u0414\u0430<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Recommended Related Products<\/h3>\n<ul>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxie-4143\/\">NI PXIe-4143 Precision Source Measure Unit<\/a> \u2013 A newer four-channel \u00b124 V, \u00b1150 mA SMU with SourceAdapt transient-response control.<\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxie-4144\/\">NI PXIe-4144 Source Measure Unit<\/a> \u2013 Provides a lower \u00b16 V range with higher current capability up to \u00b1500 mA.<\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxie-4141\/\">NI PXIe-4141 Precision Source Measure Unit<\/a> \u2013 Suitable for four-channel \u00b110 V applications requiring SourceAdapt.<\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/%d0%bf%d0%ba%d1%81%d0%b8%d0%b5-6571\/\">NI PXIe-6571 Digital Pattern Instrument<\/a> \u2013 Can be synchronized with the PXIe-4142 in mixed-signal semiconductor test systems.<\/li>\n<\/ul>\n<h3>How to Select the Correct PXI SMU<\/h3>\n<p>Choose the PXIe-4142 when the application requires four \u00b124 V channels, up to \u00b1150 mA and current sensitivity down to 100 pA. It is suitable for devices requiring a wider bipolar voltage range than lower-voltage multichannel SMUs provide.<\/p>\n<p>Choose the PXIe-4143 when custom SourceAdapt transient tuning is required. Select the PXIe-4144 or PXIe-4145 when the DUT needs up to \u00b1500 mA but operates within a \u00b16 V range.<\/p>\n<h3>Why Choose the PXIe-4142?<\/h3>\n<ul>\n<li>Combines four SMU channels in one PXI Express slot<\/li>\n<li>Supports bipolar four-quadrant operation<\/li>\n<li>Provides a wide \u00b124 V voltage range<\/li>\n<li>Measures currents with sensitivity down to 100 pA<\/li>\n<li>Captures measurements at up to 600 kS\/s per channel<\/li>\n<li>Supports deterministic hardware sequencing<\/li>\n<li>Includes remote sensing and guard connections<\/li>\n<li>Integrates with PXI semiconductor test platforms<\/li>\n<\/ul>\n<h3>Frequently Asked Questions<\/h3>\n<h4>What is the PXIe-4142 used for?<\/h4>\n<p>The PXIe-4142 sources and measures voltage and current for semiconductor characterization, mixed-signal IC testing and automated device validation.<\/p>\n<h4>What is the PXIe-4142 part number?<\/h4>\n<p>The standard NI part number is <strong>782430-01<\/strong>.<\/p>\n<h4>How many SMU channels does it provide?<\/h4>\n<p>The module provides four independently programmable SMU channels that share a common LO reference.<\/p>\n<h4>What are the maximum voltage and current?<\/h4>\n<p>Each channel supports voltages from -24 V to +24 V and currents up to \u00b1150 mA within the 3.6 W channel power limit.<\/p>\n<h4>Can the PXIe-4142 sink current?<\/h4>\n<p>Yes. Four-quadrant operation allows every channel to source or sink voltage and current within the applicable power limits.<\/p>\n<h4>Does it support SourceAdapt?<\/h4>\n<p>No. It provides predefined slow, normal and fast transient-response modes but does not support custom SourceAdapt control.<\/p>\n<h4>Does every channel support remote sensing?<\/h4>\n<p>Yes. All four channels provide four-wire remote sensing to compensate for voltage drop in the test connection.<\/p>\n<h4>What is the maximum sampling rate?<\/h4>\n<p>The PXIe-4142 supports continuous voltage and current measurements at up to 600 kS\/s per channel.<\/p>\n<h4>Are the channels independently isolated?<\/h4>\n<p>No. The channels are isolated from earth ground but share a common LO connection.<\/p>\n<h4>What software controls the PXIe-4142?<\/h4>\n<p>The module uses NI-DCPower and can be operated through InstrumentStudio or programmed with supported LabVIEW, LabWindows\/CVI, .NET and TestStand environments.<\/p>\n<h3>Request a Quote for the PXIe-4142<\/h3>\n<p>Contact us for current availability, lead time and project pricing for the <strong>PXIe-4142 Four-Channel PXI Source Measure Unit<\/strong>. We can also help identify compatible terminal blocks, cables, PXI chassis and related semiconductor test modules.<\/p>","protected":false},"excerpt":{"rendered":"<p>Current Sensitivity: 100 pA<br \/>\n\u0412\u043a\u043b\u044e\u0447\u0430\u0435\u0442 \u0432\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u0443\u044e \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u044c: \u2013<br \/>\n\u041a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u043a\u0430\u043d\u0430\u043b\u043e\u0432 SMU: 4<br \/>\n\u0414\u0438\u0430\u043f\u0430\u0437\u043e\u043d \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f: \u043e\u0442 -24 \u0412 \u0434\u043e 24 \u0412<br \/>\nSourceAdapt: \u041d\u0435\u0442<br \/>\n\u041c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u0430\u044f \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u044c \u0440\u0430\u0441\u0441\u0435\u0438\u0432\u0430\u043d\u0438\u044f \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430: 3,6 \u0412\u0442<br \/>\n\u041c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u0430\u044f \u043c\u043e\u0449\u043d\u043e\u0441\u0442\u044c \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0430 \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430: 3,6 \u0412\u0442<br \/>\n\u0414\u0438\u0430\u043f\u0430\u0437\u043e\u043d \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430: \u043e\u0442 -150 \u043c\u0410 \u0434\u043e 150 \u043c\u0410<br \/>\n\u0414\u0438\u0430\u043f\u0430\u0437\u043e\u043d \u0438\u043c\u043f\u0443\u043b\u044c\u0441\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430: \u2013<br \/>\n\u0428\u0438\u043d\u043d\u044b\u0439 \u0441\u043e\u0435\u0434\u0438\u043d\u0438\u0442\u0435\u043b\u044c: PXI Express<\/p>","protected":false},"featured_media":31710,"template":"","meta":{"_acf_changed":false},"product_brand":[18],"product_cat":[744],"product_tag":[],"class_list":["post-32430","product","type-product","status-publish","has-post-thumbnail","product_brand-national-instruments","product_cat-pxi-programmable-power-supplies-smu","first","instock","shipping-taxable","purchasable","product-type-simple"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.0 (Yoast SEO v28.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>NI PXIe-4142 PXI Source Measure Unit 782430-01, In Stock | Project Pricing<\/title>\n<meta name=\"description\" content=\"The PXIe-4142 is a four-channel \u00b124 V, \u00b1150 mA PXI SMU with four-quadrant operation, 600 kS\/s sampling, remote sense, and 100 pA sensitivity.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/pxisource.com\/ru\/product\/pxie-4142\/\" \/>\n<meta property=\"og:locale\" content=\"ru_RU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"PXIe-4142\" \/>\n<meta property=\"og:description\" content=\"The PXIe-4142 is a four-channel \u00b124 V, \u00b1150 mA PXI SMU with four-quadrant operation, 600 kS\/s sampling, remote sense, and 100 pA sensitivity.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/pxisource.com\/ru\/product\/pxie-4142\/\" \/>\n<meta property=\"og:site_name\" content=\"PXI Source\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=61582573040385\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-28T09:27:04+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PXIe-4142.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"650\" \/>\n\t<meta property=\"og:image:height\" content=\"650\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u0426\u0435\u043d\u0430\" \/>\n\t<meta name=\"twitter:data1\" content=\"&#036;16,774.00\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c\" \/>\n\t<meta name=\"twitter:data2\" content=\"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-4142\\\/\",\"url\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-4142\\\/\",\"name\":\"NI PXIe-4142 PXI Source Measure Unit 782430-01, In Stock | Project Pricing\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-4142\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-4142\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/PXIe-4142.webp\",\"datePublished\":\"2026-04-29T01:25:43+00:00\",\"dateModified\":\"2026-08-28T09:27:04+00:00\",\"description\":\"The PXIe-4142 is a four-channel \u00b124 V, \u00b1150 mA PXI SMU with four-quadrant operation, 600 kS\\\/s sampling, remote sense, and 100 pA sensitivity.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-4142\\\/#breadcrumb\"},\"inLanguage\":\"ru-RU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-4142\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-4142\\\/#primaryimage\",\"url\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/PXIe-4142.webp\",\"contentUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/PXIe-4142.webp\",\"width\":650,\"height\":650,\"caption\":\"PXIe-4142\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-4142\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/pxisource.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\\\/\\\/pxisource.com\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"PXIe-4142\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\",\"url\":\"https:\\\/\\\/pxisource.com\\\/\",\"name\":\"PXI Systems\",\"description\":\"NI PXI, PXIe Modular Test Instrument Supplier\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/pxisource.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ru-RU\"}]}<\/script>\n<meta property=\"product:brand\" content=\"National Instruments\" \/>\n<meta property=\"product:price:amount\" content=\"16774.00\" \/>\n<meta property=\"product:price:currency\" content=\"USD\" \/>\n<meta property=\"og:availability\" content=\"instock\" \/>\n<meta property=\"product:availability\" content=\"instock\" \/>\n<meta property=\"product:condition\" content=\"new\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"NI PXIe-4142 PXI Source Measure Unit 782430-01, In Stock | Project Pricing","description":"The PXIe-4142 is a four-channel \u00b124 V, \u00b1150 mA PXI SMU with four-quadrant operation, 600 kS\/s sampling, remote sense, and 100 pA sensitivity.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/pxisource.com\/ru\/product\/pxie-4142\/","og_locale":"ru_RU","og_type":"article","og_title":"PXIe-4142","og_description":"The PXIe-4142 is a four-channel \u00b124 V, \u00b1150 mA PXI SMU with four-quadrant operation, 600 kS\/s sampling, remote sense, and 100 pA sensitivity.","og_url":"https:\/\/pxisource.com\/ru\/product\/pxie-4142\/","og_site_name":"PXI Source","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=61582573040385","article_modified_time":"2026-08-28T09:27:04+00:00","og_image":[{"width":650,"height":650,"url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PXIe-4142.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"\u0426\u0435\u043d\u0430":"&#36;16,774.00","\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c":"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/pxisource.com\/product\/pxie-4142\/","url":"https:\/\/pxisource.com\/product\/pxie-4142\/","name":"NI PXIe-4142 PXI Source Measure Unit 782430-01, In Stock | Project Pricing","isPartOf":{"@id":"https:\/\/pxisource.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/pxisource.com\/product\/pxie-4142\/#primaryimage"},"image":{"@id":"https:\/\/pxisource.com\/product\/pxie-4142\/#primaryimage"},"thumbnailUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PXIe-4142.webp","datePublished":"2026-04-29T01:25:43+00:00","dateModified":"2026-08-28T09:27:04+00:00","description":"The PXIe-4142 is a four-channel \u00b124 V, \u00b1150 mA PXI SMU with four-quadrant operation, 600 kS\/s sampling, remote sense, and 100 pA sensitivity.","breadcrumb":{"@id":"https:\/\/pxisource.com\/product\/pxie-4142\/#breadcrumb"},"inLanguage":"ru-RU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/pxisource.com\/product\/pxie-4142\/"]}]},{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/pxisource.com\/product\/pxie-4142\/#primaryimage","url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PXIe-4142.webp","contentUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PXIe-4142.webp","width":650,"height":650,"caption":"PXIe-4142"},{"@type":"BreadcrumbList","@id":"https:\/\/pxisource.com\/product\/pxie-4142\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/pxisource.com\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/pxisource.com\/shop\/"},{"@type":"ListItem","position":3,"name":"PXIe-4142"}]},{"@type":"WebSite","@id":"https:\/\/pxisource.com\/#website","url":"https:\/\/pxisource.com\/","name":"\u0421\u0438\u0441\u0442\u0435\u043c\u044b PXI","description":"NI PXI, PXIe Modular Test Instrument Supplier","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/pxisource.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ru-RU"}]},"product_brand":"National Instruments","product_price_amount":"16774.00","product_price_currency":"USD","og_availability":"instock","product_availability":"instock","product_condition":"new"},"_links":{"self":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/32430","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":3,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/32430\/revisions"}],"predecessor-version":[{"id":35608,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/32430\/revisions\/35608"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media\/31710"}],"wp:attachment":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media?parent=32430"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_brand?post=32430"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_cat?post=32430"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_tag?post=32430"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}