{"id":32316,"date":"2026-04-27T10:01:56","date_gmt":"2026-04-27T02:01:56","guid":{"rendered":"https:\/\/pxisource.com\/?post_type=product&#038;p=32316"},"modified":"2026-08-27T20:26:12","modified_gmt":"2026-08-27T12:26:12","slug":"ni-9236","status":"publish","type":"product","link":"https:\/\/pxisource.com\/ru\/product\/ni-9236\/","title":{"rendered":"NI-9236"},"content":{"rendered":"<h3>Product Introduction<\/h3>\n<p>\n\u0417\u0435\u043c\u043b\u044f <strong>NI-9236<\/strong> \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f <strong>8-channel C Series strain\/bridge input module<\/strong> specifically designed for dynamic measurement of <strong>350 \u03a9 quarter-bridge strain gauges<\/strong>. It combines bridge completion, sensor excitation, signal conditioning, high-resolution analog-to-digital conversion, and simultaneous multi-channel acquisition in a compact C Series module.\n<\/p>\n<p>\nThe NI-9236 provides <strong>8 \u0430\u043d\u0430\u043b\u043e\u0433\u043e\u0432\u044b\u0445 \u0432\u0445\u043e\u0434\u043d\u044b\u0445 \u043a\u0430\u043d\u0430\u043b\u043e\u0432<\/strong>, <strong>24-bit resolution<\/strong>, and simultaneous sampling rates up to <strong>10 kS\/s per channel<\/strong>. Its synchronized acquisition architecture makes it particularly suitable for applications where strain measurements from multiple locations must be compared at the same instant.\n<\/p>\n<p>\nTypical applications include structural testing, mechanical testing, impact testing, fatigue testing, load analysis, component validation, automotive testing, aerospace testing, and structural monitoring.\n<\/p>\n<h3>Product Overview<\/h3>\n<p>\n\u0417\u0435\u043c\u043b\u044f <strong>National Instruments NI-9236<\/strong> belongs to the C Series strain and bridge measurement family and is optimized for <strong>350 \u03a9 quarter-bridge strain gauges<\/strong>.\n<\/p>\n<p>\nA typical measurement architecture is:\n<\/p>\n<p>\n<strong>350 \u03a9 Quarter-Bridge Strain Gauge \u2192 NI-9236 \u2192 CompactDAQ \/ CompactRIO \u2192 Measurement and Analysis Software<\/strong>\n<\/p>\n<p>\nBecause bridge completion and excitation are integrated into the module, the NI-9236 simplifies strain measurement system design and reduces the amount of external signal-conditioning hardware required.\n<\/p>\n<h3>Key Features<\/h3>\n<h4>8 Strain Measurement Channels<\/h4>\n<p>\nThe NI-9236 provides <strong>8 \u0430\u043d\u0430\u043b\u043e\u0433\u043e\u0432\u044b\u0445 \u0432\u0445\u043e\u0434\u043d\u044b\u0445 \u043a\u0430\u043d\u0430\u043b\u043e\u0432<\/strong> for measuring multiple quarter-bridge strain gauges from a single C Series module.\n<\/p>\n<p>\nThis channel density is useful for applications where strain must be measured at several points on a structure or mechanical component.\n<\/p>\n<p>\nTypical measurement locations can include:\n<\/p>\n<ul>\n<li>Structural beams<\/li>\n<li>Vehicle components<\/li>\n<li>Mechanical assemblies<\/li>\n<li>Test specimens<\/li>\n<li>Aircraft structures<\/li>\n<li>Machine components<\/li>\n<li>Load-bearing structures<\/li>\n<li>Prototype assemblies<\/li>\n<\/ul>\n<h4>350 \u03a9 Quarter-Bridge Strain Gauge Support<\/h4>\n<p>\nThe NI-9236 is specifically designed for <strong>350 \u03a9 quarter-bridge strain gauge measurements<\/strong>.\n<\/p>\n<p>\nThe module incorporates the required quarter-bridge completion circuitry, reducing the need for separate external bridge completion hardware.\n<\/p>\n<p>\nThis makes the NI-9236 particularly convenient when building multi-channel strain measurement systems using standard 350 \u03a9 strain gauges.\n<\/p>\n<h4>Built-In Bridge Completion<\/h4>\n<p>\nQuarter-bridge strain measurement requires additional precision resistance to complete the Wheatstone bridge.\n<\/p>\n<p>\nThe NI-9236 provides <strong>integrated 350 \u03a9 quarter-bridge completion<\/strong>.\n<\/p>\n<p>\nA simplified architecture is:\n<\/p>\n<p>\n<strong>350 \u03a9 Strain Gauge + NI-9236 Internal Bridge Completion \u2192 Complete Measurement Bridge<\/strong>\n<\/p>\n<p>\nIntegrating bridge completion inside the module simplifies wiring and reduces the number of external components required in the measurement system.\n<\/p>\n<h4>Built-In Voltage Excitation<\/h4>\n<p>\nThe NI-9236 includes <strong>built-in voltage excitation<\/strong> for quarter-bridge strain gauges.\n<\/p>\n<p>\nStrain gauges require excitation to produce a measurable bridge output. Integrating excitation into the module simplifies system configuration and helps provide a controlled measurement architecture.\n<\/p>\n<h4>24-Bit Resolution<\/h4>\n<p>\nThe NI-9236 uses a <strong>24-bit Delta-Sigma analog-to-digital converter<\/strong>.\n<\/p>\n<p>\nHigh-resolution conversion is important for strain measurements because the electrical changes generated by strain gauges can be very small.\n<\/p>\n<p>\nThe 24-bit measurement architecture helps provide the resolution required for mechanical and structural testing applications.\n<\/p>\n<h4>10 kS\/s per Channel<\/h4>\n<p>\nThe NI-9236 supports sampling rates up to <strong>10 kS\/s per channel<\/strong>.\n<\/p>\n<p>\nUnlike multiplexed measurement architectures where channels are measured sequentially, the NI-9236 provides simultaneous acquisition across its channels.\n<\/p>\n<p>\nThis makes the module suitable for dynamic strain measurements where the timing relationship between channels must be preserved.\n<\/p>\n<h4>Simultaneous Sampling<\/h4>\n<p>\nAll eight NI-9236 channels can acquire measurements simultaneously.\n<\/p>\n<p>\nSimultaneous sampling is particularly important for:\n<\/p>\n<ul>\n<li>Impact testing<\/li>\n<li>Dynamic structural testing<\/li>\n<li>Mechanical transient analysis<\/li>\n<li>Multi-point strain comparison<\/li>\n<li>Component validation<\/li>\n<li>Load event analysis<\/li>\n<\/ul>\n<p>\nWhen an impact or mechanical event occurs, simultaneous acquisition allows measurements from different strain gauges to represent the same instant in time.\n<\/p>\n<h4>Delta-Sigma ADC Architecture<\/h4>\n<p>\nThe NI-9236 uses <strong>Delta-Sigma ADC technology with analog prefiltering<\/strong>.\n<\/p>\n<p>\nThis architecture is well suited for precision dynamic measurements where high resolution, synchronized sampling, and controlled frequency response are important.\n<\/p>\n<h4>60 VDC Isolation<\/h4>\n<p>\nThe NI-9236 provides <strong>60 VDC channel-to-earth ground isolation<\/strong>.\n<\/p>\n<p>\nIsolation helps improve measurement robustness and provides protection against common-mode voltage differences between the measurement system and connected equipment.\n<\/p>\n<h4>1,000 Vrms Transient Isolation<\/h4>\n<p>\nThe module also provides <strong>1,000 Vrms transient isolation<\/strong>.\n<\/p>\n<p>\nThis helps provide increased protection against transient electrical conditions that may occur in industrial or test environments.\n<\/p>\n<h4>High Common-Mode Noise Rejection<\/h4>\n<p>\nThe isolation and differential measurement architecture help the NI-9236 provide strong rejection of common-mode electrical noise.\n<\/p>\n<p>\nThis can be particularly useful when strain gauges are installed on large structures, machinery, vehicles, or test fixtures where electrical interference may be present.\n<\/p>\n<h3>Technical Specifications<\/h3>\n<table>\n<tr>\n<th>\u041f\u0430\u0440\u0430\u043c\u0435\u0442\u0440<\/th>\n<th>\u0421\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f<\/th>\n<\/tr>\n<tr>\n<td width=\"280\">Product Type<\/td>\n<td>C Series Strain\/Bridge Input Module<\/td>\n<\/tr>\n<tr>\n<td>\u041c\u043e\u0434\u0435\u043b\u044c<\/td>\n<td>NI-9236<\/td>\n<\/tr>\n<tr>\n<td>Manufacturer<\/td>\n<td>\u041d\u0430\u0446\u0438\u043e\u043d\u0430\u043b\u044c\u043d\u044b\u0435 \u0438\u043d\u0441\u0442\u0440\u0443\u043c\u0435\u043d\u0442\u044b<\/td>\n<\/tr>\n<tr>\n<td>Bus \/ Platform<\/td>\n<td>C Series<\/td>\n<\/tr>\n<tr>\n<td>Number of Analog Input Channels<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<td>Bridge Configuration<\/td>\n<td>Quarter Bridge<\/td>\n<\/tr>\n<tr>\n<td>Nominal Bridge Resistance<\/td>\n<td>350 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>Quarter-Bridge Completion<\/td>\n<td>350 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>Quarter-Bridge Completion Temperature Coefficient<\/td>\n<td>10 ppm\/\u00b0C Maximum<\/td>\n<\/tr>\n<tr>\n<td>ADC Resolution<\/td>\n<td>24 Bit<\/td>\n<\/tr>\n<tr>\n<td>ADC Type<\/td>\n<td>Delta-Sigma with Analog Prefiltering<\/td>\n<\/tr>\n<tr>\n<td>Sampling Mode<\/td>\n<td>\u0421\u0438\u043d\u0445\u0440\u043e\u043d\u043d\u044b\u0439<\/td>\n<\/tr>\n<tr>\n<td>Maximum Sample Rate<\/td>\n<td>10 kS\/s\/ch<\/td>\n<\/tr>\n<tr>\n<td>Analog Input Range<\/td>\n<td>\u00b129.4 mV\/V<\/td>\n<\/tr>\n<tr>\n<td>Sensor Excitation<\/td>\n<td>Built-In<\/td>\n<\/tr>\n<tr>\n<td>Channel-to-Earth Isolation<\/td>\n<td>60 \u0412 \u043f\u043e\u0441\u0442\u043e\u044f\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430<\/td>\n<\/tr>\n<tr>\n<td>Transient Isolation<\/td>\n<td>1,000 Vrms<\/td>\n<\/tr>\n<tr>\n<td>Front Connection<\/td>\n<td>\u0412\u0435\u0441\u0435\u043d\u043d\u0438\u0439 \u0442\u0435\u0440\u043c\u0438\u043d\u0430\u043b<\/td>\n<\/tr>\n<tr>\n<td>Operating Temperature<\/td>\n<td>-40 \u00b0C \u0434\u043e 70 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Primary Sensor Type<\/td>\n<td>350 \u03a9 Quarter-Bridge Strain Gauge<\/td>\n<\/tr>\n<tr>\n<td>Primary Applications<\/td>\n<td>Dynamic Strain, Structural Test, Impact Test, Mechanical Test and Data Acquisition<\/td>\n<\/tr>\n<\/table>\n<h3>NI-9236 Part Numbers<\/h3>\n<p>\nThe NI-9236 is available in standard and conformal-coated configurations.\n<\/p>\n<table>\n<tr>\n<th>Part Number<\/th>\n<th>\u041a\u043e\u043d\u0444\u0438\u0433\u0443\u0440\u0430\u0446\u0438\u044f<\/th>\n<th>Conformal Coating<\/th>\n<\/tr>\n<tr>\n<td><strong>785996-01<\/strong><\/td>\n<td>NI-9236 Standard Version<\/td>\n<td>No<\/td>\n<\/tr>\n<tr>\n<td><strong>779994-02<\/strong><\/td>\n<td>NI-9236 Conformal-Coated Version<\/td>\n<td>\u0414\u0430<\/td>\n<\/tr>\n<\/table>\n<p>\nBoth versions provide the same core 8-channel, 350 \u03a9 quarter-bridge strain measurement functionality. The conformal-coated version is intended for applications requiring additional protection of the module electronics against environmental contaminants and moisture.\n<\/p>\n<h3>Included NI-9966 Terminal Plug<\/h3>\n<p>\nThe NI-9236 uses a <strong>34-position spring terminal connection<\/strong>.\n<\/p>\n<p>\nNI lists the <strong>NI-9966 34-position spring terminal plug<\/strong> as an included item with the NI-9236.\n<\/p>\n<p>\nWhen purchasing a used NI-9236, verify whether the NI-9966 terminal plug is included because replacement modules may be supplied without their original removable terminal connector.\n<\/p>\n<h3>How Does the NI-9236 Work?<\/h3>\n<p>\nA strain gauge changes electrical resistance when the material to which it is attached experiences mechanical deformation.\n<\/p>\n<p>\nBecause the resistance change is very small, the strain gauge is typically incorporated into a Wheatstone bridge measurement circuit.\n<\/p>\n<p>\nThe NI-9236 simplifies this process by providing bridge completion, excitation, signal conditioning, and analog-to-digital conversion.\n<\/p>\n<p>\nA simplified signal path is:\n<\/p>\n<p>\n<strong>Mechanical Strain \u2192 350 \u03a9 Strain Gauge \u2192 Wheatstone Quarter Bridge \u2192 NI-9236 \u2192 24-Bit ADC \u2192 Digital Strain Data<\/strong>\n<\/p>\n<h3>What Is a Quarter-Bridge Strain Gauge?<\/h3>\n<p>\nA quarter-bridge configuration uses <strong>one active strain gauge<\/strong> as part of a Wheatstone bridge.\n<\/p>\n<p>\nThe remaining bridge resistance is provided by completion resistors.\n<\/p>\n<p>\nA simplified architecture is:\n<\/p>\n<p>\n<strong>1 Active Strain Gauge + Bridge Completion Resistors = Quarter-Bridge Measurement<\/strong>\n<\/p>\n<p>\nQuarter-bridge configurations are widely used because they require only one active strain gauge at each measurement location.\n<\/p>\n<h3>350 \u03a9 Strain Gauge Measurement<\/h3>\n<p>\nThe NI-9236 is optimized for nominal <strong>350 \u03a9 strain gauges<\/strong>.\n<\/p>\n<p>\nNI specifies 350 \u03a9 quarter-bridge completion resistance for the module.\n<\/p>\n<p>\nThis distinction is important because NI also offers modules intended for other nominal bridge resistances.\n<\/p>\n<h3>350 \u03a9 Gauge Resistance Range<\/h3>\n<p>\nAlthough the NI-9236 is nominally designed for 350 \u03a9 strain gauges, compatible gauges do not necessarily need to measure exactly 350.000 \u03a9.\n<\/p>\n<p>\nBased on the module&#8217;s \u00b129.4 mV\/V input range and quarter-bridge architecture, the practical resistance range is approximately:\n<\/p>\n<table>\n<tr>\n<th>\u041f\u0430\u0440\u0430\u043c\u0435\u0442\u0440<\/th>\n<th>Resistance<\/th>\n<\/tr>\n<tr>\n<td>Minimum<\/td>\n<td>Approximately 311 \u03a9<\/td>\n<\/tr>\n<tr>\n<td>Nominal<\/td>\n<td><strong>350 \u03a9<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Maximum<\/td>\n<td>Approximately 394 \u03a9<\/td>\n<\/tr>\n<\/table>\n<p>\nSensor compatibility should still be verified against the complete NI-9236 specifications before installation.\n<\/p>\n<h3>Dynamic Strain Measurement<\/h3>\n<p>\nThe combination of <strong>10 kS\/s\/ch sampling<\/strong> and simultaneous acquisition makes the NI-9236 suitable for dynamic strain measurement.\n<\/p>\n<p>\nDynamic strain applications involve mechanical loads that change over time, such as:\n<\/p>\n<ul>\n<li>Impact events<\/li>\n<li>Mechanical vibration<\/li>\n<li>Rapid loading<\/li>\n<li>Structural movement<\/li>\n<li>Component deformation<\/li>\n<li>Transient mechanical events<\/li>\n<\/ul>\n<h3>Impact Testing<\/h3>\n<p>\nImpact testing is an important application for the NI-9236 because all eight channels can be sampled simultaneously.\n<\/p>\n<p>\n\u041d\u0430\u043f\u0440\u0438\u043c\u0435\u0440:\n<\/p>\n<p>\n<strong>Gauge 1 \u2192 Structural Point A<\/strong><br \/>\n<strong>Gauge 2 \u2192 Structural Point B<\/strong><br \/>\n<strong>Gauge 3 \u2192 Structural Point C<\/strong><br \/>\n<strong>Gauge 4 \u2192 Structural Point D<\/strong><br \/>\n<strong>Gauges 5\u20138 \u2192 Additional Measurement Locations<\/strong>\n<\/p>\n<p>\nWhen an impact occurs, all channels capture the event on the same sampling timeline, allowing engineers to compare how different parts of the structure respond.\n<\/p>\n<h3>Structural Testing<\/h3>\n<p>\nThe NI-9236 can be used for multi-point structural strain measurement during static and dynamic mechanical tests.\n<\/p>\n<p>\nTypical structures include:\n<\/p>\n<ul>\n<li>Frames<\/li>\n<li>Beams<\/li>\n<li>Vehicle structures<\/li>\n<li>Aircraft components<\/li>\n<li>Mechanical assemblies<\/li>\n<li>Test fixtures<\/li>\n<li>Prototype structures<\/li>\n<\/ul>\n<h3>Fatigue Testing<\/h3>\n<p>\nFatigue testing repeatedly loads a component to evaluate how it behaves over time.\n<\/p>\n<p>\nThe NI-9236 can acquire strain measurements from multiple locations while the test specimen undergoes repeated mechanical loading.\n<\/p>\n<p>\nMeasurement software can then analyze:\n<\/p>\n<ul>\n<li>Maximum strain<\/li>\n<li>Minimum strain<\/li>\n<li>Strain range<\/li>\n<li>Cycle behavior<\/li>\n<li>Structural response<\/li>\n<li>Changes during test duration<\/li>\n<\/ul>\n<h3>Mechanical Component Validation<\/h3>\n<p>\nDuring component validation, engineers can install multiple 350 \u03a9 strain gauges on critical areas of the DUT.\n<\/p>\n<p>\nThe NI-9236 can simultaneously acquire these signals while the component is subjected to mechanical loads.\n<\/p>\n<p>\nThis allows engineers to compare measured strain with:\n<\/p>\n<ul>\n<li>Design calculations<\/li>\n<li>Finite element analysis<\/li>\n<li>Simulation results<\/li>\n<li>Material limits<\/li>\n<li>Previous test results<\/li>\n<\/ul>\n<h3>Automotive Testing<\/h3>\n<p>\nAutomotive test systems frequently require multi-channel strain measurements from vehicle structures and mechanical components.\n<\/p>\n<p>\nPotential applications include:\n<\/p>\n<ul>\n<li>Chassis testing<\/li>\n<li>Suspension component testing<\/li>\n<li>Vehicle structural testing<\/li>\n<li>Powertrain component testing<\/li>\n<li>Durability testing<\/li>\n<li>Road-load testing<\/li>\n<li>Component fatigue testing<\/li>\n<\/ul>\n<h3>Aerospace Testing<\/h3>\n<p>\nThe NI-9236 can be used in aerospace structural test systems where multiple strain gauges monitor deformation under mechanical loading.\n<\/p>\n<p>\nApplications can include:\n<\/p>\n<ul>\n<li>Airframe testing<\/li>\n<li>Wing structural testing<\/li>\n<li>Mechanical component validation<\/li>\n<li>Ground testing<\/li>\n<li>Structural load testing<\/li>\n<li>Prototype validation<\/li>\n<\/ul>\n<h3>NI-9236 vs NI-9235<\/h3>\n<p>\nThe NI-9235 and NI-9236 are closely related quarter-bridge strain measurement modules. The primary difference is the nominal strain gauge resistance.\n<\/p>\n<table>\n<tr>\n<th>\u0424\u0443\u043d\u043a\u0446\u0438\u044f<\/th>\n<th>NI-9236<\/th>\n<th>NI-9235<\/th>\n<\/tr>\n<tr>\n<td>Bridge Configuration<\/td>\n<td>Quarter Bridge<\/td>\n<td>Quarter Bridge<\/td>\n<\/tr>\n<tr>\n<td>Nominal Gauge Resistance<\/td>\n<td><strong>350 \u03a9<\/strong><\/td>\n<td><strong>120 \u03a9<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u041a\u0430\u043d\u0430\u043b\u044b<\/td>\n<td>8<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<td>\u0420\u0430\u0437\u0440\u0435\u0448\u0435\u043d\u0438\u0435<\/td>\n<td>24 Bit<\/td>\n<td>24 Bit<\/td>\n<\/tr>\n<tr>\n<td>Maximum Sampling Rate<\/td>\n<td>10 kS\/s\/ch<\/td>\n<td>10 kS\/s\/ch<\/td>\n<\/tr>\n<tr>\n<td>Sampling Architecture<\/td>\n<td>\u0421\u0438\u043d\u0445\u0440\u043e\u043d\u043d\u044b\u0439<\/td>\n<td>\u0421\u0438\u043d\u0445\u0440\u043e\u043d\u043d\u044b\u0439<\/td>\n<\/tr>\n<tr>\n<td>Best Application<\/td>\n<td><strong>350 \u03a9 Quarter-Bridge Gauges<\/strong><\/td>\n<td><strong>120 \u03a9 Quarter-Bridge Gauges<\/strong><\/td>\n<\/tr>\n<\/table>\n<p>\nIf the application uses 350 \u03a9 quarter-bridge strain gauges, the NI-9236 is the appropriate model. For nominal 120 \u03a9 quarter-bridge gauges, the NI-9235 should be considered.\n<\/p>\n<h3>NI-9236 vs NI-9237<\/h3>\n<p>\nThe NI-9236 and NI-9237 are both C Series strain\/bridge input modules, but they are optimized for different bridge configurations and measurement requirements.\n<\/p>\n<table>\n<tr>\n<th>\u0424\u0443\u043d\u043a\u0446\u0438\u044f<\/th>\n<th>NI-9236<\/th>\n<th>NI-9237<\/th>\n<\/tr>\n<tr>\n<td>\u041a\u0430\u043d\u0430\u043b\u044b<\/td>\n<td><strong>8<\/strong><\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<td>Primary Bridge Configuration<\/td>\n<td><strong>350 \u03a9 Quarter Bridge<\/strong><\/td>\n<td>More Flexible Bridge Measurements<\/td>\n<\/tr>\n<tr>\n<td>\u0420\u0430\u0437\u0440\u0435\u0448\u0435\u043d\u0438\u0435<\/td>\n<td>24 Bit<\/td>\n<td>24 Bit<\/td>\n<\/tr>\n<tr>\n<td>Maximum Sample Rate<\/td>\n<td>10 kS\/s\/ch<\/td>\n<td><strong>50 kS\/s\/ch<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Primary Advantage<\/td>\n<td><strong>8-Channel 350 \u03a9 Quarter-Bridge Measurement<\/strong><\/td>\n<td>Higher Speed and Bridge Flexibility<\/td>\n<\/tr>\n<\/table>\n<p>\nChoose the NI-9236 when the application primarily uses multiple 350 \u03a9 quarter-bridge strain gauges. Consider the NI-9237 when higher sampling rates or additional bridge configurations are required.\n<\/p>\n<h3>NI-9236 vs General-Purpose Voltage Input Modules<\/h3>\n<p>\nA general-purpose voltage input module can measure electrical voltage, but it does not necessarily provide the bridge-specific functionality required for direct strain gauge measurement.\n<\/p>\n<table>\n<tr>\n<th>\u0424\u0443\u043d\u043a\u0446\u0438\u044f<\/th>\n<th>NI-9236<\/th>\n<th>General Voltage Input Module<\/th>\n<\/tr>\n<tr>\n<td>Strain Gauge Measurement<\/td>\n<td><strong>Purpose-Built<\/strong><\/td>\n<td>Requires Additional Conditioning<\/td>\n<\/tr>\n<tr>\n<td>350 \u03a9 Bridge Completion<\/td>\n<td><strong>Integrated<\/strong><\/td>\n<td>Typically External<\/td>\n<\/tr>\n<tr>\n<td>Sensor Excitation<\/td>\n<td><strong>Integrated<\/strong><\/td>\n<td>Typically External<\/td>\n<\/tr>\n<tr>\n<td>Strain Scaling<\/td>\n<td><strong>Designed for Bridge Measurement<\/strong><\/td>\n<td>Additional Configuration Required<\/td>\n<\/tr>\n<\/table>\n<h3>NI-9236 with CompactDAQ<\/h3>\n<p>\nThe NI-9236 can be installed in compatible <strong>\u041a\u043e\u043c\u043f\u0430\u043a\u0442\u043d\u044b\u0439 \u0426\u0410\u041f<\/strong> chassis for PC-based strain measurement.\n<\/p>\n<p>\nA typical system consists of:\n<\/p>\n<ul>\n<li>350 \u03a9 strain gauges<\/li>\n<li>NI-9236<\/li>\n<li>CompactDAQ chassis<\/li>\n<li>Host computer<\/li>\n<li>\u041d\u0418-DAQmx<\/li>\n<li>LabVIEW, FlexLogger, or compatible software<\/li>\n<\/ul>\n<p>\nThis architecture is suitable for laboratory structural testing, component validation, fatigue testing, and multi-channel strain data logging.\n<\/p>\n<h3>NI-9236 with CompactRIO<\/h3>\n<p>\nThe NI-9236 can also be integrated into compatible <strong>CompactRIO<\/strong> systems for embedded and distributed strain measurement.\n<\/p>\n<p>\nA typical architecture is:\n<\/p>\n<p>\n<strong>Strain Gauges \u2192 NI-9236 \u2192 CompactRIO \u2192 Real-Time \/ FPGA System \u2192 Analysis, Logging or Control<\/strong>\n<\/p>\n<p>\nCompactRIO integration can be useful for rugged field testing, embedded monitoring, industrial structural measurement, and distributed test systems.\n<\/p>\n<h3>NI-DAQmx Integration<\/h3>\n<p>\nWhen used with compatible CompactDAQ hardware, the NI-9236 can be configured through <strong>\u041d\u0418-DAQmx<\/strong>.\n<\/p>\n<p>\nTypical configuration parameters include:\n<\/p>\n<ul>\n<li>Physical channel<\/li>\n<li>Bridge configuration<\/li>\n<li>Gauge resistance<\/li>\n<li>Gauge factor<\/li>\n<li>Excitation<\/li>\n<li>Sample rate<\/li>\n<li>Strain units<\/li>\n<li>Initial bridge balance<\/li>\n<\/ul>\n<h3>LabVIEW Integration<\/h3>\n<p>\nThe NI-9236 can be incorporated into compatible <strong>\u041b\u0430\u0431\u0412\u044c\u044e<\/strong> applications for automated strain measurement, data acquisition, analysis, visualization, and test control.\n<\/p>\n<p>\nA typical workflow is:\n<\/p>\n<p>\n<strong>Configure Strain Channels \u2192 Balance Bridge \u2192 Configure Timing \u2192 Acquire Data \u2192 Analyze Strain \u2192 Display \/ Log Results<\/strong>\n<\/p>\n<h3>FlexLogger Applications<\/h3>\n<p>\nThe NI-9236 can also be used with compatible <strong>FlexLogger<\/strong> configurations for interactive sensor setup and data logging.\n<\/p>\n<p>\nThis can simplify applications that require:\n<\/p>\n<ul>\n<li>Multiple strain channels<\/li>\n<li>Live measurement displays<\/li>\n<li>\u0420\u0435\u0433\u0438\u0441\u0442\u0440\u0430\u0446\u0438\u044f \u0434\u0430\u043d\u043d\u044b\u0445<\/li>\n<li>Calculated channels<\/li>\n<li>Test monitoring<\/li>\n<li>Engineering-unit scaling<\/li>\n<\/ul>\n<h3>Strain Gauge Wiring Considerations<\/h3>\n<p>\nCorrect strain gauge wiring is critical for obtaining accurate measurements.\n<\/p>\n<p>\nBefore connecting a gauge to the NI-9236, verify:\n<\/p>\n<ul>\n<li>Gauge resistance<\/li>\n<li>Quarter-bridge configuration<\/li>\n<li>Gauge factor<\/li>\n<li>Lead-wire configuration<\/li>\n<li>Terminal connections<\/li>\n<li>Shielding<\/li>\n<li>Grounding<\/li>\n<li>Expected strain range<\/li>\n<li>Temperature environment<\/li>\n<\/ul>\n<h3>Bridge Balancing<\/h3>\n<p>\nA strain gauge bridge may produce a non-zero output even when no mechanical strain is applied.\n<\/p>\n<p>\nThis offset can result from:\n<\/p>\n<ul>\n<li>Gauge resistance tolerance<\/li>\n<li>Installation stress<\/li>\n<li>Lead-wire resistance<\/li>\n<li>Temperature<\/li>\n<li>Mechanical preload<\/li>\n<li>Bridge component tolerances<\/li>\n<\/ul>\n<p>\nBridge balancing or offset compensation should therefore be performed before precision strain measurements.\n<\/p>\n<h3>Gauge Factor<\/h3>\n<p>\n\u0417\u0435\u043c\u043b\u044f <strong>gauge factor<\/strong> describes how much the electrical resistance of a strain gauge changes relative to mechanical strain.\n<\/p>\n<p>\nThe correct gauge factor must be entered into the measurement configuration to convert the electrical bridge output into accurate engineering strain values.\n<\/p>\n<p>\nAlways use the gauge factor supplied by the strain gauge manufacturer whenever available.\n<\/p>\n<h3>Temperature Effects<\/h3>\n<p>\nTemperature changes can affect strain gauge resistance and therefore influence measurement accuracy.\n<\/p>\n<p>\nFor demanding measurements, consider:\n<\/p>\n<ul>\n<li>Gauge temperature coefficient<\/li>\n<li>Specimen material<\/li>\n<li>Gauge installation method<\/li>\n<li>Lead-wire resistance<\/li>\n<li>Ambient temperature variation<\/li>\n<li>Temperature compensation strategy<\/li>\n<\/ul>\n<h3>Troubleshooting NI-9236 Measurements<\/h3>\n<p>\nIf NI-9236 measurements are unstable or incorrect, check the complete measurement system.\n<\/p>\n<ol>\n<li>Verify that the NI-9236 is detected by the chassis.<\/li>\n<li>Confirm that a compatible 350 \u03a9 quarter-bridge gauge is connected.<\/li>\n<li>Check the strain gauge wiring.<\/li>\n<li>Verify the NI-9966 terminal connections.<\/li>\n<li>Confirm the correct gauge factor.<\/li>\n<li>Perform bridge balancing before measurement.<\/li>\n<li>Verify the sample rate.<\/li>\n<li>Check cable shielding and grounding.<\/li>\n<li>Inspect the strain gauge installation.<\/li>\n<li>Check for temperature-induced drift.<\/li>\n<li>Verify CompactDAQ or CompactRIO software compatibility.<\/li>\n<\/ol>\n<h3>How to Choose a C Series Strain Input Module<\/h3>\n<p>\nBefore selecting the NI-9236, determine:\n<\/p>\n<ul>\n<li>Required number of strain channels<\/li>\n<li>Quarter-, half-, or full-bridge configuration<\/li>\n<li>Nominal strain gauge resistance<\/li>\n<li>Required sample rate<\/li>\n<li>Need for simultaneous sampling<\/li>\n<li>Required resolution<\/li>\n<li>Excitation requirements<\/li>\n<li>Isolation requirements<\/li>\n<li>CompactDAQ or CompactRIO chassis<\/li>\n<li>Environmental requirements<\/li>\n<li>Software compatibility<\/li>\n<\/ul>\n<h3>Industries<\/h3>\n<ul>\n<li>Automotive<\/li>\n<li>Aerospace<\/li>\n<li>Mechanical Engineering<\/li>\n<li>Structural Engineering<\/li>\n<li>Manufacturing<\/li>\n<li>Transportation<\/li>\n<li>Energy<\/li>\n<li>Research and Development<\/li>\n<li>Automated Test<\/li>\n<li>Industrial Measurement<\/li>\n<\/ul>\n<h3>Applications<\/h3>\n<h4>Dynamic Strain Measurement<\/h4>\n<p>\nThe NI-9236 provides simultaneous 10 kS\/s\/ch acquisition for dynamic strain measurements using 350 \u03a9 quarter-bridge strain gauges.\n<\/p>\n<h4>Structural Testing<\/h4>\n<p>\nEight synchronized channels allow strain to be measured at multiple locations on a structure during mechanical loading.\n<\/p>\n<h4>Impact Testing<\/h4>\n<p>\nSimultaneous sampling allows all channels to capture the same impact event, making the NI-9236 suitable for transient mechanical tests.\n<\/p>\n<h4>Fatigue Testing<\/h4>\n<p>\nThe module can monitor strain at multiple locations during repeated loading and durability testing.\n<\/p>\n<h4>Automotive Testing<\/h4>\n<p>\nThe NI-9236 can measure strain on vehicle chassis, suspension systems, mechanical components, and structural assemblies.\n<\/p>\n<h4>Aerospace Structural Testing<\/h4>\n<p>\nMultiple 350 \u03a9 strain gauges can be monitored simultaneously during airframe and aerospace component testing.\n<\/p>\n<h4>Mechanical Component Validation<\/h4>\n<p>\nThe NI-9236 can compare measured mechanical strain against design calculations, simulation results, and engineering limits.\n<\/p>\n<h3>Recommended Related Products<\/h3>\n<table>\n<tr>\n<td width=\"220\"><strong>NI-9236<\/strong><\/td>\n<td>8-channel, 350 \u03a9 quarter-bridge strain input module with 24-bit simultaneous acquisition at up to 10 kS\/s\/ch.<\/td>\n<\/tr>\n<tr>\n<td><strong>NI-9235<\/strong><\/td>\n<td>8-channel quarter-bridge strain input module designed for nominal 120 \u03a9 strain gauges.<\/td>\n<\/tr>\n<tr>\n<td><strong>NI-9237<\/strong><\/td>\n<td>4-channel, 24-bit bridge input module with up to 50 kS\/s\/ch for applications requiring higher speed and more flexible bridge configurations.<\/td>\n<\/tr>\n<tr>\n<td><strong>NI-9219<\/strong><\/td>\n<td>Universal C Series analog input module supporting multiple sensor and measurement types for lower-speed applications.<\/td>\n<\/tr>\n<\/table>\n<h3>Why Choose NI-9236?<\/h3>\n<ul>\n<li>8 analog strain input channels<\/li>\n<li>Designed for 350 \u03a9 quarter-bridge strain gauges<\/li>\n<li>Integrated 350 \u03a9 bridge completion<\/li>\n<li>Built-in sensor excitation<\/li>\n<li>24-\u0431\u0438\u0442\u043d\u044b\u0439 \u0434\u0435\u043b\u044c\u0442\u0430-\u0441\u0438\u0433\u043c\u0430 \u0410\u0426\u041f<\/li>\n<li>Up to 10 kS\/s per channel<\/li>\n<li>\u0421\u0438\u043d\u0445\u0440\u043e\u043d\u043d\u0430\u044f \u0432\u044b\u0431\u043e\u0440\u043a\u0430<\/li>\n<li>\u00b129.4 mV\/V input range<\/li>\n<li>60 VDC channel-to-earth isolation<\/li>\n<li>1,000 Vrms transient isolation<\/li>\n<li>High common-mode noise rejection<\/li>\n<li>Spring-terminal connectivity<\/li>\n<li>Standard and conformal-coated versions available<\/li>\n<li>Suitable for dynamic strain measurement<\/li>\n<li>Suitable for impact testing<\/li>\n<li>Suitable for structural testing<\/li>\n<li>Suitable for fatigue testing<\/li>\n<li>Suitable for automotive and aerospace validation<\/li>\n<\/ul>\n<h3>Frequently Asked Questions<\/h3>\n<h4>What is the NI-9236?<\/h4>\n<p>\nThe NI-9236 is an 8-channel C Series strain\/bridge input module designed for dynamic measurement of 350 \u03a9 quarter-bridge strain gauges.\n<\/p>\n<h4>How many channels does NI-9236 have?<\/h4>\n<p>\nThe NI-9236 provides <strong>8 \u0430\u043d\u0430\u043b\u043e\u0433\u043e\u0432\u044b\u0445 \u0432\u0445\u043e\u0434\u043d\u044b\u0445 \u043a\u0430\u043d\u0430\u043b\u043e\u0432<\/strong>.\n<\/p>\n<h4>What type of strain gauge does NI-9236 support?<\/h4>\n<p>\nThe NI-9236 is specifically designed for <strong>350 \u03a9 quarter-bridge strain gauges<\/strong>.\n<\/p>\n<h4>What is the resolution of NI-9236?<\/h4>\n<p>\nThe NI-9236 uses a <strong>24-\u0431\u0438\u0442\u043d\u044b\u0439 \u0434\u0435\u043b\u044c\u0442\u0430-\u0441\u0438\u0433\u043c\u0430 \u0410\u0426\u041f<\/strong>.\n<\/p>\n<h4>What is the maximum sampling rate of NI-9236?<\/h4>\n<p>\nThe NI-9236 supports sampling rates up to <strong>10 kS\/s per channel<\/strong>.\n<\/p>\n<h4>Is NI-9236 10 kS\/s per channel or aggregate?<\/h4>\n<p>\nThe NI-9236 specification is <strong>10 kS\/s per channel<\/strong>. Its channels are simultaneously sampled, rather than sharing a single 10 kS\/s aggregate sampling rate.\n<\/p>\n<h4>Does NI-9236 support simultaneous sampling?<\/h4>\n<p>\nYes. All eight channels are simultaneously sampled, making the NI-9236 particularly suitable for dynamic strain and impact measurements.\n<\/p>\n<h4>Does NI-9236 provide bridge completion?<\/h4>\n<p>\nYes. The NI-9236 includes built-in <strong>350 \u03a9 quarter-bridge completion<\/strong>.\n<\/p>\n<h4>Does NI-9236 provide strain gauge excitation?<\/h4>\n<p>\nYes. The NI-9236 includes built-in voltage excitation for compatible quarter-bridge strain gauges.\n<\/p>\n<h4>What is the input range of NI-9236?<\/h4>\n<p>\nThe NI-9236 has a specified analog input range of approximately <strong>-29.4 mV\/V to +29.4 mV\/V<\/strong>.\n<\/p>\n<h4>Is NI-9236 isolated?<\/h4>\n<p>\nYes. The NI-9236 provides <strong>60 VDC channel-to-earth ground isolation<\/strong> \u0438 <strong>1,000 Vrms transient isolation<\/strong>.\n<\/p>\n<h4>What are the NI-9236 part numbers?<\/h4>\n<p>\nThe primary NI-9236 part numbers are <strong>785996-01<\/strong> for the standard version and <strong>779994-02<\/strong> for the conformal-coated version.\n<\/p>\n<h4>What is the difference between NI-9236 785996-01 and 779994-02?<\/h4>\n<p>\nBoth provide the same core NI-9236 strain measurement functionality. Part number <strong>779994-02<\/strong> has conformal coating, while <strong>785996-01<\/strong> is the standard non-conformal-coated configuration.\n<\/p>\n<h4>What terminal connector does NI-9236 use?<\/h4>\n<p>\nThe NI-9236 uses a spring-terminal connection. NI lists the <strong>NI-9966 34-position spring terminal plug<\/strong> with the module.\n<\/p>\n<h4>Can NI-9236 measure a 120 \u03a9 strain gauge?<\/h4>\n<p>\nThe NI-9236 is designed around 350 \u03a9 quarter-bridge completion. For nominal 120 \u03a9 quarter-bridge strain gauges, the <strong>NI-9235<\/strong> is the corresponding C Series module and is generally the appropriate choice.\n<\/p>\n<h4>What is the difference between NI-9236 and NI-9235?<\/h4>\n<p>\nThe primary difference is bridge resistance. The NI-9236 is designed for <strong>350 \u03a9 quarter-bridge strain gauges<\/strong>, while the NI-9235 is designed for <strong>120 \u03a9 quarter-bridge strain gauges<\/strong>.\n<\/p>\n<h4>What is the difference between NI-9236 and NI-9237?<\/h4>\n<p>\nThe NI-9236 provides eight channels optimized for 350 \u03a9 quarter-bridge gauges at up to 10 kS\/s\/ch. The NI-9237 provides four channels, supports more flexible bridge measurement configurations, and offers sampling rates up to 50 kS\/s\/ch.\n<\/p>\n<h4>Can NI-9236 be used for impact testing?<\/h4>\n<p>\nYes. Impact testing is an important NI-9236 application because its eight channels are sampled simultaneously, allowing strain measurements from different locations to be compared at the same instant.\n<\/p>\n<h4>Can NI-9236 be used with CompactDAQ?<\/h4>\n<p>\nYes. The NI-9236 can be used with compatible CompactDAQ chassis for PC-based strain measurement, structural testing, and data logging.\n<\/p>\n<h4>Can NI-9236 be used with CompactRIO?<\/h4>\n<p>\nYes. The NI-9236 can be integrated into compatible CompactRIO systems for embedded, rugged, and distributed strain measurement applications.\n<\/p>\n<h4>What should I check before purchasing NI-9236?<\/h4>\n<p>\nVerify that your application uses 350 \u03a9 quarter-bridge strain gauges, and check the required channel count, 10 kS\/s\/ch sampling capability, simultaneous acquisition requirement, gauge factor, wiring, NI-9966 terminal connector, CompactDAQ or CompactRIO chassis compatibility, software compatibility, and whether the standard or conformal-coated version is required.\n<\/p>\n<h3>\u0417\u0430\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435<\/h3>\n<p>\n\u0417\u0435\u043c\u043b\u044f <strong>NI-9236 8-Channel C Series Strain\/Bridge Input Module<\/strong> is specifically optimized for high-resolution measurement of 350 \u03a9 quarter-bridge strain gauges. With eight simultaneously sampled channels, 24-bit Delta-Sigma conversion, sampling rates up to 10 kS\/s\/ch, built-in bridge completion, integrated excitation, 60 VDC channel-to-earth isolation, and 1,000 Vrms transient isolation, it is particularly well suited for dynamic strain measurement, impact testing, structural testing, fatigue analysis, automotive validation, aerospace testing, and multi-channel mechanical measurement systems.<\/p>","protected":false},"excerpt":{"rendered":"<p>Bridge Configurations: &#8211;<br \/>\n\u041c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u0435 \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u0434\u0438\u0444\u0444\u0435\u0440\u0435\u043d\u0446\u0438\u0430\u043b\u044c\u043d\u044b\u0445 \u0430\u043d\u0430\u043b\u043e\u0433\u043e\u0432\u044b\u0445 \u0432\u0445\u043e\u0434\u043d\u044b\u0445 \u043a\u0430\u043d\u0430\u043b\u043e\u0432: 8<br \/>\nAnalog Input Voltage Range: -29.4 mV\/V to 29.4 mV\/V<br \/>\n\u0412 \u043a\u043e\u043c\u043f\u043b\u0435\u043a\u0442 \u0432\u0445\u043e\u0434\u0438\u0442: \u0414\u0430<br \/>\nMaximum Sample Rate: 10 kS\/s\/ch<br \/>\n\u0422\u0438\u043f \u0444\u0440\u043e\u043d\u0442\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f: \u043f\u0440\u0443\u0436\u0438\u043d\u043d\u044b\u0439 \u0437\u0430\u0436\u0438\u043c<br \/>\n\u041f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u043c\u0430\u044f \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u0430\u044f \u043f\u043b\u0430\u0442\u0444\u043e\u0440\u043c\u0430: \u0421\u0435\u0440\u0438\u044f C<br \/>\nBridge Resistance: 350 Ohm<\/p>","protected":false},"featured_media":31049,"template":"","meta":{"_acf_changed":false},"product_brand":[18],"product_cat":[781],"product_tag":[],"class_list":["post-32316","product","type-product","status-publish","has-post-thumbnail","product_brand-national-instruments","product_cat-c-series-dynamic-signal-module","first","instock","shipping-taxable","purchasable","product-type-simple"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.0 (Yoast SEO v28.1) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>NI-9236 C Series Strain\/Bridge Input 779994-02, In Stock | Project Pricing<\/title>\n<meta name=\"description\" content=\"NI-9236 is an 8-channel C Series strain\/bridge input module for 350 \u03a9 quarter-bridge strain gauges, with 24-bit simultaneous sampling at up to 10 kS\/s\/ch.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/pxisource.com\/ru\/product\/ni-9236\/\" \/>\n<meta property=\"og:locale\" content=\"ru_RU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"NI-9236\" \/>\n<meta property=\"og:description\" content=\"NI-9236 is an 8-channel C Series strain\/bridge input module for 350 \u03a9 quarter-bridge strain gauges, with 24-bit simultaneous sampling at up to 10 kS\/s\/ch.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/pxisource.com\/ru\/product\/ni-9236\/\" \/>\n<meta property=\"og:site_name\" content=\"PXI Source\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=61582573040385\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-27T12:26:12+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/NI-9236.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"800\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u0426\u0435\u043d\u0430\" \/>\n\t<meta name=\"twitter:data1\" content=\"&#036;3,361.00\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c\" \/>\n\t<meta name=\"twitter:data2\" content=\"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/ni-9236\\\/\",\"url\":\"https:\\\/\\\/pxisource.com\\\/product\\\/ni-9236\\\/\",\"name\":\"NI-9236 C Series Strain\\\/Bridge Input 779994-02, In Stock | Project Pricing\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/ni-9236\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/ni-9236\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/NI-9236.webp\",\"datePublished\":\"2026-04-27T02:01:56+00:00\",\"dateModified\":\"2026-08-27T12:26:12+00:00\",\"description\":\"NI-9236 is an 8-channel C Series strain\\\/bridge input module for 350 \u03a9 quarter-bridge strain gauges, with 24-bit simultaneous sampling at up to 10 kS\\\/s\\\/ch.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/ni-9236\\\/#breadcrumb\"},\"inLanguage\":\"ru-RU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/pxisource.com\\\/product\\\/ni-9236\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/ni-9236\\\/#primaryimage\",\"url\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/NI-9236.webp\",\"contentUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/NI-9236.webp\",\"width\":800,\"height\":800,\"caption\":\"NI-9236\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/ni-9236\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/pxisource.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u5546\u5e97\",\"item\":\"https:\\\/\\\/pxisource.com\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"NI-9236\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\",\"url\":\"https:\\\/\\\/pxisource.com\\\/\",\"name\":\"PXI Systems\",\"description\":\"PXI, PXIe and Modular Test Equipment\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/pxisource.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ru-RU\"}]}<\/script>\n<meta property=\"product:brand\" content=\"National Instruments\" \/>\n<meta property=\"product:price:amount\" content=\"3361.00\" \/>\n<meta property=\"product:price:currency\" content=\"USD\" \/>\n<meta property=\"og:availability\" content=\"instock\" \/>\n<meta property=\"product:availability\" content=\"instock\" \/>\n<meta property=\"product:condition\" content=\"new\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"NI-9236 C Series Strain\/Bridge Input 779994-02, In Stock | Project Pricing","description":"NI-9236 is an 8-channel C Series strain\/bridge input module for 350 \u03a9 quarter-bridge strain gauges, with 24-bit simultaneous sampling at up to 10 kS\/s\/ch.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/pxisource.com\/ru\/product\/ni-9236\/","og_locale":"ru_RU","og_type":"article","og_title":"NI-9236","og_description":"NI-9236 is an 8-channel C Series strain\/bridge input module for 350 \u03a9 quarter-bridge strain gauges, with 24-bit simultaneous sampling at up to 10 kS\/s\/ch.","og_url":"https:\/\/pxisource.com\/ru\/product\/ni-9236\/","og_site_name":"PXI Source","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=61582573040385","article_modified_time":"2026-08-27T12:26:12+00:00","og_image":[{"width":800,"height":800,"url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/NI-9236.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"\u0426\u0435\u043d\u0430":"&#36;3,361.00","\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c":"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/pxisource.com\/product\/ni-9236\/","url":"https:\/\/pxisource.com\/product\/ni-9236\/","name":"NI-9236 C Series Strain\/Bridge Input 779994-02, In Stock | Project Pricing","isPartOf":{"@id":"https:\/\/pxisource.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/pxisource.com\/product\/ni-9236\/#primaryimage"},"image":{"@id":"https:\/\/pxisource.com\/product\/ni-9236\/#primaryimage"},"thumbnailUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/NI-9236.webp","datePublished":"2026-04-27T02:01:56+00:00","dateModified":"2026-08-27T12:26:12+00:00","description":"NI-9236 is an 8-channel C Series strain\/bridge input module for 350 \u03a9 quarter-bridge strain gauges, with 24-bit simultaneous sampling at up to 10 kS\/s\/ch.","breadcrumb":{"@id":"https:\/\/pxisource.com\/product\/ni-9236\/#breadcrumb"},"inLanguage":"ru-RU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/pxisource.com\/product\/ni-9236\/"]}]},{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/pxisource.com\/product\/ni-9236\/#primaryimage","url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/NI-9236.webp","contentUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/NI-9236.webp","width":800,"height":800,"caption":"NI-9236"},{"@type":"BreadcrumbList","@id":"https:\/\/pxisource.com\/product\/ni-9236\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/pxisource.com\/"},{"@type":"ListItem","position":2,"name":"\u5546\u5e97","item":"https:\/\/pxisource.com\/shop\/"},{"@type":"ListItem","position":3,"name":"NI-9236"}]},{"@type":"WebSite","@id":"https:\/\/pxisource.com\/#website","url":"https:\/\/pxisource.com\/","name":"\u0421\u0438\u0441\u0442\u0435\u043c\u044b PXI","description":"PXI, PXIe and Modular Test Equipment","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/pxisource.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ru-RU"}]},"product_brand":"National Instruments","product_price_amount":"3361.00","product_price_currency":"USD","og_availability":"instock","product_availability":"instock","product_condition":"new"},"_links":{"self":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/32316","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":3,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/32316\/revisions"}],"predecessor-version":[{"id":35534,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/32316\/revisions\/35534"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media\/31049"}],"wp:attachment":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media?parent=32316"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_brand?post=32316"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_cat?post=32316"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_tag?post=32316"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}