{"id":32289,"date":"2026-04-27T09:18:54","date_gmt":"2026-04-27T01:18:54","guid":{"rendered":"https:\/\/pxisource.com\/?post_type=product&#038;p=32289"},"modified":"2026-07-02T09:49:01","modified_gmt":"2026-07-02T01:49:01","slug":"ni-9227","status":"publish","type":"product","link":"https:\/\/pxisource.com\/ru\/product\/ni-9227","title":{"rendered":"NI-9227"},"content":{"rendered":"<p data-start=\"356\" data-end=\"718\">\u0417\u0435\u043c\u043b\u044f <strong data-start=\"360\" data-end=\"371\">NI-9227<\/strong> is a high-accuracy <strong data-start=\"391\" data-end=\"424\">\u041c\u043e\u0434\u0443\u043b\u044c \u0432\u0432\u043e\u0434\u0430 \u0442\u043e\u043a\u0430 \u0441\u0435\u0440\u0438\u0438 C<\/strong> \u043f\u0440\u0435\u0434\u043d\u0430\u0437\u043d\u0430\u0447\u0435\u043d \u0434\u043b\u044f <strong data-start=\"438\" data-end=\"452\">CompactRIO<\/strong> \u0438 <strong data-start=\"457\" data-end=\"471\">\u041a\u043e\u043c\u043f\u0430\u043a\u0442\u043d\u044b\u0439 \u0426\u0410\u041f<\/strong> \u0441\u0438\u0441\u0442\u0435\u043c\u044b. \u041e\u043d \u043f\u0440\u0435\u0434\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 <strong data-start=\"493\" data-end=\"553\">4 simultaneously sampled isolated current input channels<\/strong>, supporting up to <strong data-start=\"572\" data-end=\"602\">5 Arms current measurement<\/strong>, with <strong data-start=\"609\" data-end=\"630\">24-bit resolution<\/strong> and sampling rates up to <strong data-start=\"656\" data-end=\"679\">50 kS\/s per channel<\/strong>.<\/p>\n<p data-start=\"720\" data-end=\"814\">Unlike general-purpose voltage acquisition modules, the NI-9227 is optimized specifically for:<\/p>\n<ul data-start=\"816\" data-end=\"1022\">\n<li data-section-id=\"3s6prg\" data-start=\"816\" data-end=\"848\">Industrial current measurement<\/li>\n<li data-section-id=\"1dvrlqk\" data-start=\"849\" data-end=\"876\">Power and energy analysis<\/li>\n<li data-section-id=\"wapcw6\" data-start=\"877\" data-end=\"903\">Motor current monitoring<\/li>\n<li data-section-id=\"mzxf4n\" data-start=\"904\" data-end=\"935\">Electrical system diagnostics<\/li>\n<li data-section-id=\"151futj\" data-start=\"936\" data-end=\"955\">Harmonic analysis<\/li>\n<li data-section-id=\"9u6xyt\" data-start=\"956\" data-end=\"983\">Embedded power monitoring<\/li>\n<li data-section-id=\"1w9160e\" data-start=\"984\" data-end=\"1022\">Dynamic current waveform acquisition<\/li>\n<\/ul>\n<p data-start=\"1024\" data-end=\"1055\">The module is commonly used in:<\/p>\n<ul data-start=\"1057\" data-end=\"1226\">\n<li data-section-id=\"rb6wls\" data-start=\"1057\" data-end=\"1080\">\u041f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u0430\u044f \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0437\u0430\u0446\u0438\u044f<\/li>\n<li data-section-id=\"ivkis0\" data-start=\"1081\" data-end=\"1108\">Power electronics testing<\/li>\n<li data-section-id=\"18antpd\" data-start=\"1109\" data-end=\"1130\">Inverter monitoring<\/li>\n<li data-section-id=\"cif8m7\" data-start=\"1131\" data-end=\"1151\">\u0421\u0438\u0441\u0442\u0435\u043c\u044b \u0443\u043c\u043d\u044b\u0445 \u0441\u0435\u0442\u0435\u0439<\/li>\n<li data-section-id=\"1axmu4b\" data-start=\"1152\" data-end=\"1177\">Motor drive diagnostics<\/li>\n<li data-section-id=\"axc1ub\" data-start=\"1178\" data-end=\"1197\">Appliance testing<\/li>\n<li data-section-id=\"ncg08\" data-start=\"1198\" data-end=\"1226\">Embedded energy monitoring<\/li>\n<\/ul>\n<h3 data-section-id=\"11kr24w\" data-start=\"1233\" data-end=\"1269\">Current Measurement Architecture<\/h3>\n<p data-start=\"1271\" data-end=\"1292\">The NI-9227 provides:<\/p>\n<ul data-start=\"1294\" data-end=\"1531\">\n<li data-section-id=\"1defo2h\" data-start=\"1294\" data-end=\"1331\"><strong data-start=\"1296\" data-end=\"1331\">4 analog current input channels<\/strong><\/li>\n<li data-section-id=\"ed23un\" data-start=\"1332\" data-end=\"1364\"><strong data-start=\"1334\" data-end=\"1364\">5 Arms nominal input range<\/strong><\/li>\n<li data-section-id=\"1fddk6s\" data-start=\"1365\" data-end=\"1392\"><strong data-start=\"1367\" data-end=\"1392\">24-\u0431\u0438\u0442\u043d\u043e\u0435 \u0440\u0430\u0437\u0440\u0435\u0448\u0435\u043d\u0438\u0435 \u0410\u0426\u041f<\/strong><\/li>\n<li data-section-id=\"1gcytv6\" data-start=\"1393\" data-end=\"1420\"><strong data-start=\"1395\" data-end=\"1420\">\u0421\u0438\u043d\u0445\u0440\u043e\u043d\u043d\u0430\u044f \u0432\u044b\u0431\u043e\u0440\u043a\u0430<\/strong><\/li>\n<li data-section-id=\"yodil3\" data-start=\"1421\" data-end=\"1455\"><strong data-start=\"1423\" data-end=\"1455\">Channel-to-channel isolation<\/strong><\/li>\n<li data-section-id=\"1ybmkqk\" data-start=\"1456\" data-end=\"1531\">Sampling rates up to <strong data-start=\"1479\" data-end=\"1493\">50 kS\/s\/ch<\/strong><\/li>\n<\/ul>\n<p data-start=\"1533\" data-end=\"1717\">The module uses precision shunt-based current sensing combined with analog and digital filtering to provide accurate current waveform acquisition.<\/p>\n<p data-start=\"1719\" data-end=\"1832\">One of the key advantages of the NI-9227 is that all channels are sampled simultaneously, making it suitable for:<\/p>\n<ul data-start=\"1834\" data-end=\"1972\">\n<li data-section-id=\"17st69a\" data-start=\"1834\" data-end=\"1862\">Multi-phase power analysis<\/li>\n<li data-section-id=\"148q6d4\" data-start=\"1863\" data-end=\"1894\">Motor current synchronization<\/li>\n<li data-section-id=\"1m3ofz\" data-start=\"1895\" data-end=\"1917\">Harmonic measurement<\/li>\n<li data-section-id=\"1c5rbmc\" data-start=\"1918\" data-end=\"1941\">Dynamic power systems<\/li>\n<li data-section-id=\"1shydq\" data-start=\"1942\" data-end=\"1972\">Electrical transient capture<\/li>\n<\/ul>\n<p data-start=\"1974\" data-end=\"2093\">Compared with multiplexed current modules, simultaneous sampling ensures accurate phase relationships between channels.<\/p>\n<h3 data-section-id=\"1hxfi5m\" data-start=\"2100\" data-end=\"2141\">High-Accuracy Measurement Performance<\/h3>\n<p data-start=\"2143\" data-end=\"2198\">The NI-9227 is designed for precision current analysis.<\/p>\n<p data-start=\"2200\" data-end=\"2239\">Key performance specifications include:<\/p>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"2241\" data-end=\"2530\">\n<thead data-start=\"2241\" data-end=\"2266\">\n<tr data-start=\"2241\" data-end=\"2266\">\n<th class=\"last:pe-10\" data-start=\"2241\" data-end=\"2257\" data-col-size=\"sm\">\u0421\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f<\/th>\n<th class=\"last:pe-10\" data-start=\"2257\" data-end=\"2266\" data-col-size=\"sm\">\u0426\u0435\u043d\u043d\u043e\u0441\u0442\u044c<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"2277\" data-end=\"2530\">\n<tr data-start=\"2277\" data-end=\"2300\">\n<td data-start=\"2277\" data-end=\"2290\" data-col-size=\"sm\">\u0420\u0430\u0437\u0440\u0435\u0448\u0435\u043d\u0438\u0435<\/td>\n<td data-start=\"2290\" data-end=\"2300\" data-col-size=\"sm\">24-\u0431\u0438\u0442<\/td>\n<\/tr>\n<tr data-start=\"2301\" data-end=\"2337\">\n<td data-start=\"2301\" data-end=\"2323\" data-col-size=\"sm\">Maximum sample rate<\/td>\n<td data-start=\"2323\" data-end=\"2337\" data-col-size=\"sm\">50 kS\/s\/ch<\/td>\n<\/tr>\n<tr data-start=\"2338\" data-end=\"2374\">\n<td data-start=\"2338\" data-end=\"2354\" data-col-size=\"sm\">Current range<\/td>\n<td data-start=\"2354\" data-end=\"2374\" data-col-size=\"sm\">0 Arms to 5 Arms<\/td>\n<\/tr>\n<tr data-start=\"2375\" data-end=\"2406\">\n<td data-start=\"2375\" data-end=\"2399\" data-col-size=\"sm\">\u0421\u0438\u043d\u0445\u0440\u043e\u043d\u043d\u0430\u044f \u0432\u044b\u0431\u043e\u0440\u043a\u0430<\/td>\n<td data-col-size=\"sm\" data-start=\"2399\" data-end=\"2406\">\u0414\u0430<\/td>\n<\/tr>\n<tr data-start=\"2407\" data-end=\"2434\">\n<td data-start=\"2407\" data-end=\"2427\" data-col-size=\"sm\">Channel isolation<\/td>\n<td data-start=\"2427\" data-end=\"2434\" data-col-size=\"sm\">\u0414\u0430<\/td>\n<\/tr>\n<tr data-start=\"2435\" data-end=\"2530\">\n<td data-start=\"2435\" data-end=\"2458\" data-col-size=\"sm\">Alias-free bandwidth<\/td>\n<td data-start=\"2458\" data-end=\"2491\" data-col-size=\"sm\">Optimized by digital filtering<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p data-start=\"2532\" data-end=\"2557\">The module also includes:<\/p>\n<ul data-start=\"2559\" data-end=\"2728\">\n<li data-section-id=\"178vqym\" data-start=\"2559\" data-end=\"2591\">Built-in anti-aliasing filters<\/li>\n<li data-section-id=\"fafsj4\" data-start=\"2592\" data-end=\"2617\">High stopband rejection<\/li>\n<li data-section-id=\"4m4v5x\" data-start=\"2618\" data-end=\"2650\">Passband flatness optimization<\/li>\n<li data-section-id=\"1dw1x9j\" data-start=\"2651\" data-end=\"2728\">Frequency-dependent digital filtering<\/li>\n<\/ul>\n<p data-start=\"2730\" data-end=\"2775\">These features make the NI-9227 suitable for:<\/p>\n<ul data-start=\"2777\" data-end=\"2891\">\n<li data-section-id=\"6sk2p4\" data-start=\"2777\" data-end=\"2801\">Power quality analysis<\/li>\n<li data-section-id=\"vlpzw\" data-start=\"2802\" data-end=\"2821\">Noise measurement<\/li>\n<li data-section-id=\"uf9vjt\" data-start=\"2822\" data-end=\"2843\">Harmonic monitoring<\/li>\n<li data-section-id=\"1tn6nh2\" data-start=\"2844\" data-end=\"2870\">Current waveform capture<\/li>\n<li data-section-id=\"1pguyym\" data-start=\"2871\" data-end=\"2891\">Frequency analysis<\/li>\n<\/ul>\n<h3 data-section-id=\"19v61hg\" data-start=\"2898\" data-end=\"2934\">Simultaneous Sampling Advantages<\/h3>\n<p data-start=\"2936\" data-end=\"3066\">Unlike lower-cost multiplexed modules, the NI-9227 samples all four channels simultaneously.<\/p>\n<p data-start=\"3068\" data-end=\"3109\">This is critical in applications such as:<\/p>\n<h4 data-start=\"3111\" data-end=\"3144\">Three-Phase Power Monitoring<\/h4>\n<p data-start=\"3146\" data-end=\"3261\">Engineers can accurately measure phase relationships, current imbalance, and harmonics across multiple power lines.<\/p>\n<h4 data-start=\"3263\" data-end=\"3288\">Motor Drive Analysis<\/h4>\n<p data-start=\"3290\" data-end=\"3379\">The module can synchronize acquisition across multiple motor phases for dynamic analysis.<\/p>\n<h4 data-start=\"3381\" data-end=\"3409\">Transient Event Capture<\/h4>\n<p data-start=\"3411\" data-end=\"3506\">Simultaneous sampling ensures accurate timing during fast current changes and switching events.<\/p>\n<h4 data-start=\"3508\" data-end=\"3538\">Power Electronics Testing<\/h4>\n<p data-start=\"3540\" data-end=\"3620\">The NI-9227 is widely used in inverter, UPS, and converter testing applications.<\/p>\n<h3 data-section-id=\"u3kmcz\" data-start=\"3627\" data-end=\"3672\">Power and Energy Measurement Applications<\/h3>\n<p data-start=\"3674\" data-end=\"3822\">The NI-9227 is often paired with high-voltage modules such as the <strong data-start=\"3740\" data-end=\"3751\">NI-9225<\/strong> for full power analysis systems.<\/p>\n<p data-start=\"3824\" data-end=\"3893\">Combined voltage and current acquisition allows engineers to measure:<\/p>\n<ul data-start=\"3895\" data-end=\"4005\">\n<li data-section-id=\"1f3n5ob\" data-start=\"3895\" data-end=\"3909\">Active power<\/li>\n<li data-section-id=\"1tal0x8\" data-start=\"3910\" data-end=\"3926\">Reactive power<\/li>\n<li data-section-id=\"150f2yi\" data-start=\"3927\" data-end=\"3941\">Power factor<\/li>\n<li data-section-id=\"14vcxxi\" data-start=\"3942\" data-end=\"3953\">Harmonics<\/li>\n<li data-section-id=\"1b77bik\" data-start=\"3954\" data-end=\"3965\">Frequency<\/li>\n<li data-section-id=\"e6evov\" data-start=\"3966\" data-end=\"3986\">Energy consumption<\/li>\n<li data-section-id=\"268gyg\" data-start=\"3987\" data-end=\"4005\">Electrical noise<\/li>\n<\/ul>\n<p data-start=\"4007\" data-end=\"4050\">This makes the NI-9227 highly suitable for:<\/p>\n<ul data-start=\"4052\" data-end=\"4184\">\n<li data-section-id=\"axc1ub\" data-start=\"4052\" data-end=\"4071\">Appliance testing<\/li>\n<li data-section-id=\"ztqz51\" data-start=\"4072\" data-end=\"4094\">Smart energy systems<\/li>\n<li data-section-id=\"1m9h1dz\" data-start=\"4095\" data-end=\"4124\">Renewable energy monitoring<\/li>\n<li data-section-id=\"1nacfm5\" data-start=\"4125\" data-end=\"4156\">Electrical compliance testing<\/li>\n<li data-section-id=\"q1puo6\" data-start=\"4157\" data-end=\"4184\">Motor efficiency analysis<\/li>\n<\/ul>\n<h3 data-section-id=\"1hi8xtw\" data-start=\"4191\" data-end=\"4240\">FPGA Integration and Deterministic Processing<\/h3>\n<p data-start=\"4242\" data-end=\"4370\">When installed in CompactRIO systems, the NI-9227 interfaces directly with FPGA resources.<\/p>\n<p data-start=\"4372\" data-end=\"4396\">\u0418\u043d\u0436\u0435\u043d\u0435\u0440\u044b \u043c\u043e\u0433\u0443\u0442 \u0440\u0435\u0430\u043b\u0438\u0437\u043e\u0432\u0430\u0442\u044c:<\/p>\n<ul data-start=\"4398\" data-end=\"4556\">\n<li data-section-id=\"1ih41b4\" data-start=\"4398\" data-end=\"4428\">Real-time current protection<\/li>\n<li data-section-id=\"jpzsqs\" data-start=\"4429\" data-end=\"4451\">FPGA-based filtering<\/li>\n<li data-section-id=\"4a1i7w\" data-start=\"4452\" data-end=\"4478\">\u0414\u0435\u0442\u0435\u0440\u043c\u0438\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u043e\u0435 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u0435<\/li>\n<li data-section-id=\"1vkql0p\" data-start=\"4479\" data-end=\"4507\">Embedded harmonic analysis<\/li>\n<li data-section-id=\"kx519p\" data-start=\"4508\" data-end=\"4530\">Fast fault detection<\/li>\n<li data-section-id=\"1jxdq2q\" data-start=\"4531\" data-end=\"4556\">Real-time control loops<\/li>\n<\/ul>\n<p data-start=\"4558\" data-end=\"4703\">Because the FPGA processes signals locally, the system can achieve extremely low-latency decision making compared with PC-only DAQ architectures.<\/p>\n<p data-start=\"4705\" data-end=\"4750\">This architecture is especially valuable for:<\/p>\n<ul data-start=\"4752\" data-end=\"4854\">\n<li data-section-id=\"u1fh3n\" data-start=\"4752\" data-end=\"4781\">Embedded protection systems<\/li>\n<li data-section-id=\"1qvny90\" data-start=\"4782\" data-end=\"4797\">Motor control<\/li>\n<li data-section-id=\"6bcbbs\" data-start=\"4798\" data-end=\"4819\">Smart power systems<\/li>\n<li data-section-id=\"1tdesd0\" data-start=\"4820\" data-end=\"4854\">High-speed industrial automation<\/li>\n<\/ul>\n<h3 data-section-id=\"12m365u\" data-start=\"4861\" data-end=\"4896\">Isolation and Industrial Safety<\/h3>\n<p data-start=\"4898\" data-end=\"4919\">The NI-9227 provides:<\/p>\n<ul data-start=\"4921\" data-end=\"5080\">\n<li data-section-id=\"yodil3\" data-start=\"4921\" data-end=\"4955\"><strong data-start=\"4923\" data-end=\"4955\">Channel-to-channel isolation<\/strong><\/li>\n<li data-section-id=\"5jq7uf\" data-start=\"4956\" data-end=\"4980\">Floating analog inputs<\/li>\n<li data-section-id=\"14dgpd0\" data-start=\"4981\" data-end=\"5011\">Hazardous voltage protection<\/li>\n<li data-section-id=\"qgtes3\" data-start=\"5012\" data-end=\"5080\">Industrial safety compliance<\/li>\n<\/ul>\n<p data-start=\"5082\" data-end=\"5111\">Isolation advantages include:<\/p>\n<ul data-start=\"5113\" data-end=\"5231\">\n<li data-section-id=\"yvxhzh\" data-start=\"5113\" data-end=\"5143\">Reduced ground loop problems<\/li>\n<li data-section-id=\"ftlos5\" data-start=\"5144\" data-end=\"5173\">Safer industrial deployment<\/li>\n<li data-section-id=\"1ts3abz\" data-start=\"5174\" data-end=\"5200\">Improved noise rejection<\/li>\n<li data-section-id=\"1wzc7lh\" data-start=\"5201\" data-end=\"5231\">Better measurement integrity<\/li>\n<\/ul>\n<p data-start=\"5233\" data-end=\"5343\">The module is designed for industrial current measurement environments where electrical isolation is critical.<\/p>\n<h3 data-section-id=\"1n8k1x1\" data-start=\"5350\" data-end=\"5378\">\u041f\u0440\u043e\u0447\u043d\u044b\u0439 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u044b\u0439 \u0434\u0438\u0437\u0430\u0439\u043d<\/h3>\n<p data-start=\"5380\" data-end=\"5436\">The NI-9227 is designed for harsh industrial deployment.<\/p>\n<p data-start=\"5438\" data-end=\"5472\">\u041f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u044b\u0435 \u0441\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u0438 \u0432\u043a\u043b\u044e\u0447\u0430\u044e\u0442:<\/p>\n<ul data-start=\"5474\" data-end=\"5678\">\n<li data-section-id=\"43boza\" data-start=\"5474\" data-end=\"5518\">\u0420\u0430\u0431\u043e\u0447\u0430\u044f \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u0430: <strong data-start=\"5499\" data-end=\"5518\">-40 \u00b0C \u0434\u043e 70 \u00b0C<\/strong><\/li>\n<li data-section-id=\"srvfaw\" data-start=\"5519\" data-end=\"5561\">\u0422\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u0430 \u0445\u0440\u0430\u043d\u0435\u043d\u0438\u044f: <strong data-start=\"5542\" data-end=\"5561\">\u043e\u0442 -40 \u00b0C \u0434\u043e 85 \u00b0C<\/strong><\/li>\n<li data-section-id=\"1w6et7p\" data-start=\"5562\" data-end=\"5593\">\u0421\u043b\u0443\u0447\u0430\u0439\u043d\u0430\u044f \u0432\u0438\u0431\u0440\u0430\u0446\u0438\u044f: <strong data-start=\"5582\" data-end=\"5593\">5 \u0433 \u0441\u0440\u0435\u0434\u043d\u0435\u043a\u0432\u0430\u0434\u0440\u0430\u0442\u0438\u0447\u043d\u043e\u0435<\/strong><\/li>\n<li data-section-id=\"1qr70jz\" data-start=\"5594\" data-end=\"5622\">\u0423\u0434\u0430\u0440\u043e\u043f\u0440\u043e\u0447\u043d\u043e\u0441\u0442\u044c: <strong data-start=\"5614\" data-end=\"5622\">50 \u0433<\/strong><\/li>\n<li data-section-id=\"q2q3\" data-start=\"5623\" data-end=\"5678\">\u0417\u0430\u0449\u0438\u0442\u0430 IP40<\/li>\n<\/ul>\n<p data-start=\"5680\" data-end=\"5700\">\u041c\u043e\u0434\u0443\u043b\u044c \u043f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u0442:<\/p>\n<ul data-start=\"5702\" data-end=\"5809\">\n<li data-section-id=\"nujqst\" data-start=\"5702\" data-end=\"5722\">CompactRIO systems<\/li>\n<li data-section-id=\"17nmvl9\" data-start=\"5723\" data-end=\"5743\">CompactDAQ systems<\/li>\n<li data-section-id=\"1slsr07\" data-start=\"5744\" data-end=\"5773\">\u041f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u044b\u0435 \u0432\u0441\u0442\u0440\u0430\u0438\u0432\u0430\u0435\u043c\u044b\u0435 \u0441\u0438\u0441\u0442\u0435\u043c\u044b<\/li>\n<li data-section-id=\"71q6jh\" data-start=\"5774\" data-end=\"5809\">Distributed measurement platforms<\/li>\n<\/ul>\n<p data-start=\"5811\" data-end=\"5863\">These characteristics make the NI-9227 suitable for:<\/p>\n<ul data-start=\"5865\" data-end=\"5986\">\n<li data-section-id=\"z6ewqr\" data-start=\"5865\" data-end=\"5885\">\u0410\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0437\u0430\u0446\u0438\u044f \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0441\u0442\u0432\u0430<\/li>\n<li data-section-id=\"13p8e7h\" data-start=\"5886\" data-end=\"5909\">\u042d\u043d\u0435\u0440\u0433\u0435\u0442\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u0438\u043d\u0444\u0440\u0430\u0441\u0442\u0440\u0443\u043a\u0442\u0443\u0440\u0430<\/li>\n<li data-section-id=\"1co9474\" data-start=\"5910\" data-end=\"5934\">\u0422\u0440\u0430\u043d\u0441\u043f\u043e\u0440\u0442\u043d\u044b\u0435 \u0441\u0438\u0441\u0442\u0435\u043c\u044b<\/li>\n<li data-section-id=\"d4k3ep\" data-start=\"5935\" data-end=\"5957\">\u041f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0435 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u0435<\/li>\n<li data-section-id=\"9gsmju\" data-start=\"5958\" data-end=\"5986\">Outdoor monitoring systems<\/li>\n<\/ul>\n<h3 data-section-id=\"1b4m36n\" data-start=\"5993\" data-end=\"6027\">\u041f\u0440\u0438\u043a\u043b\u0430\u0434\u043d\u044b\u0435 \u0432\u0430\u0440\u0438\u0430\u043d\u0442\u044b \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f<\/h3>\n<h4 data-start=\"6029\" data-end=\"6058\">Motor Current Monitoring<\/h4>\n<p data-start=\"6060\" data-end=\"6181\">The NI-9227 is widely used for monitoring industrial motor current waveforms and detecting abnormal operating conditions.<\/p>\n<h4 data-start=\"6183\" data-end=\"6213\">Power Electronics Testing<\/h4>\n<p data-start=\"6215\" data-end=\"6305\">Engineers use the module for inverter, UPS, converter, and switching power supply testing.<\/p>\n<h4 data-start=\"6307\" data-end=\"6332\">Smart Energy Systems<\/h4>\n<p data-start=\"6334\" data-end=\"6405\">The module supports embedded energy monitoring and smart grid analysis.<\/p>\n<h4 data-start=\"6407\" data-end=\"6442\">Industrial Machine Diagnostics<\/h4>\n<p data-start=\"6444\" data-end=\"6536\">The NI-9227 can capture current transients and electrical anomalies in industrial machinery.<\/p>\n<h3 data-section-id=\"1pckxth\" data-start=\"6543\" data-end=\"6578\">\u0421\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u0435 \u0441 \u0430\u043d\u0430\u043b\u043e\u0433\u0438\u0447\u043d\u044b\u043c\u0438 \u043c\u043e\u0434\u0443\u043b\u044f\u043c\u0438<\/h3>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"6580\" data-end=\"7020\">\n<thead data-start=\"6580\" data-end=\"6621\">\n<tr data-start=\"6580\" data-end=\"6621\">\n<th class=\"last:pe-10\" data-start=\"6580\" data-end=\"6588\" data-col-size=\"sm\">\u041c\u043e\u0434\u0435\u043b\u044c<\/th>\n<th class=\"last:pe-10\" data-start=\"6588\" data-end=\"6606\" data-col-size=\"sm\">\u041e\u0441\u043d\u043e\u0432\u043d\u043e\u0435 \u0440\u0430\u0437\u043b\u0438\u0447\u0438\u0435<\/th>\n<th class=\"last:pe-10\" data-start=\"6606\" data-end=\"6621\" data-col-size=\"sm\">\u0422\u0438\u043f\u0438\u0447\u043d\u043e\u0435 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"6636\" data-end=\"7020\">\n<tr data-start=\"6636\" data-end=\"6709\">\n<td data-start=\"6636\" data-end=\"6650\" data-col-size=\"sm\"><strong data-start=\"6638\" data-end=\"6649\">\u041d\u0418-9203<\/strong><\/td>\n<td data-start=\"6650\" data-end=\"6684\" data-col-size=\"sm\">Lower-cost \u00b120 mA current input<\/td>\n<td data-start=\"6684\" data-end=\"6709\" data-col-size=\"sm\">Process current loops<\/td>\n<\/tr>\n<tr data-start=\"6710\" data-end=\"6792\">\n<td data-start=\"6710\" data-end=\"6724\" data-col-size=\"sm\"><strong data-start=\"6712\" data-end=\"6723\">\u041d\u0418-9208<\/strong><\/td>\n<td data-start=\"6724\" data-end=\"6753\" data-col-size=\"sm\">High-density current input<\/td>\n<td data-col-size=\"sm\" data-start=\"6753\" data-end=\"6792\">Multi-channel industrial monitoring<\/td>\n<\/tr>\n<tr data-start=\"6793\" data-end=\"6875\">\n<td data-start=\"6793\" data-end=\"6807\" data-col-size=\"sm\"><strong data-start=\"6795\" data-end=\"6806\">NI-9227<\/strong><\/td>\n<td data-start=\"6807\" data-end=\"6847\" data-col-size=\"sm\">5 Arms isolated simultaneous sampling<\/td>\n<td data-start=\"6847\" data-end=\"6875\" data-col-size=\"sm\">Power and motor analysis<\/td>\n<\/tr>\n<tr data-start=\"6876\" data-end=\"6941\">\n<td data-start=\"6876\" data-end=\"6890\" data-col-size=\"sm\"><strong data-start=\"6878\" data-end=\"6889\">NI-9225<\/strong><\/td>\n<td data-start=\"6890\" data-end=\"6918\" data-col-size=\"sm\">High-voltage input module<\/td>\n<td data-start=\"6918\" data-end=\"6941\" data-col-size=\"sm\">Voltage acquisition<\/td>\n<\/tr>\n<tr data-start=\"6942\" data-end=\"7020\">\n<td data-start=\"6942\" data-end=\"6956\" data-col-size=\"sm\"><strong data-start=\"6944\" data-end=\"6955\">NI-9246<\/strong><\/td>\n<td data-start=\"6956\" data-end=\"6994\" data-col-size=\"sm\">Current + voltage power measurement<\/td>\n<td data-start=\"6994\" data-end=\"7020\" data-col-size=\"sm\">Power quality analysis<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p data-start=\"7022\" data-end=\"7383\">\u041f\u043e \u0441\u0440\u0430\u0432\u043d\u0435\u043d\u0438\u044e \u0441 <strong data-start=\"7040\" data-end=\"7051\">\u041d\u0418-9203<\/strong>, the NI-9227 supports much higher current levels and simultaneous sampling. Compared with the <strong data-start=\"7146\" data-end=\"7157\">\u041d\u0418-9208<\/strong>, it focuses more on dynamic waveform and power analysis rather than high channel density. The NI-9227 is commonly paired with the <strong data-start=\"7288\" data-end=\"7299\">NI-9225<\/strong> for synchronized power measurement systems.<\/p>\n<h3 data-section-id=\"1079bb9\" data-start=\"7390\" data-end=\"7404\">\u0417\u0430\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435<\/h3>\n<p data-start=\"7406\" data-end=\"7576\">\u0417\u0435\u043c\u043b\u044f <strong data-start=\"7410\" data-end=\"7421\">NI-9227<\/strong> is a rugged high-accuracy <strong data-start=\"7448\" data-end=\"7482\">4-channel current input module<\/strong> designed for CompactRIO and CompactDAQ systems requiring precise dynamic current measurement.<\/p>\n<p data-start=\"7578\" data-end=\"7597\">\u0415\u0433\u043e \u0441\u043e\u0447\u0435\u0442\u0430\u043d\u0438\u0435:<\/p>\n<ul data-start=\"7599\" data-end=\"7774\">\n<li data-section-id=\"u0syvy\" data-start=\"7599\" data-end=\"7634\">4 isolated current input channels<\/li>\n<li data-section-id=\"1web56t\" data-start=\"7635\" data-end=\"7661\">5 Arms measurement range<\/li>\n<li data-section-id=\"1pfsk5u\" data-start=\"7662\" data-end=\"7681\">24-bit resolution<\/li>\n<li data-section-id=\"yp5quq\" data-start=\"7682\" data-end=\"7705\">\u0421\u0438\u043d\u0445\u0440\u043e\u043d\u043d\u0430\u044f \u0432\u044b\u0431\u043e\u0440\u043a\u0430<\/li>\n<li data-section-id=\"19xzldy\" data-start=\"7706\" data-end=\"7724\">\u0418\u043d\u0442\u0435\u0433\u0440\u0430\u0446\u0438\u044f \u041f\u041b\u0418\u0421<\/li>\n<li data-section-id=\"1do2gff\" data-start=\"7725\" data-end=\"7747\">\u041f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u0430\u044f \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u044f<\/li>\n<li data-section-id=\"r0tl7f\" data-start=\"7748\" data-end=\"7774\">\u041f\u0440\u043e\u0447\u043d\u044b\u0439 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u044b\u0439 \u0434\u0438\u0437\u0430\u0439\u043d<\/li>\n<\/ul>\n<p data-start=\"7776\" data-end=\"7989\">makes it an excellent solution for power analysis, motor diagnostics, embedded energy monitoring, industrial automation, and high-performance electrical measurement systems.<\/p>","protected":false},"excerpt":{"rendered":"<p>\u041c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u0435 \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u0434\u0438\u0444\u0444\u0435\u0440\u0435\u043d\u0446\u0438\u0430\u043b\u044c\u043d\u044b\u0445 \u0430\u043d\u0430\u043b\u043e\u0433\u043e\u0432\u044b\u0445 \u0432\u0445\u043e\u0434\u043d\u044b\u0445 \u043a\u0430\u043d\u0430\u043b\u043e\u0432: 4<br \/>\n\u041c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u0435 \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u043e\u0434\u043d\u043e\u043a\u043e\u043d\u0446\u043e\u0432\u044b\u0445 \u0430\u043d\u0430\u043b\u043e\u0433\u043e\u0432\u044b\u0445 \u0432\u0445\u043e\u0434\u043d\u044b\u0445 \u043a\u0430\u043d\u0430\u043b\u043e\u0432: 0<br \/>\n\u0412 \u043a\u043e\u043c\u043f\u043b\u0435\u043a\u0442 \u0432\u0445\u043e\u0434\u0438\u0442: \u0414\u0430<br \/>\n\u0410\u043d\u0430\u043b\u043e\u0433\u043e\u0432\u043e\u0435 \u0440\u0430\u0437\u0440\u0435\u0448\u0435\u043d\u0438\u0435 \u0432\u0445\u043e\u0434\u0430: 24 \u0431\u0438\u0442\u0430<br \/>\n\u041c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u0430\u044f \u0447\u0430\u0441\u0442\u043e\u0442\u0430 \u0434\u0438\u0441\u043a\u0440\u0435\u0442\u0438\u0437\u0430\u0446\u0438\u0438: 50 \u043a\u0432\u044b\u0431\/\u0441\/\u043a\u0430\u043d<br \/>\n\u0418\u0437\u043e\u043b\u044f\u0446\u0438\u044f \u0430\u043d\u0430\u043b\u043e\u0433\u043e\u0432\u043e\u0433\u043e \u0432\u0445\u043e\u0434\u0430: 250 \u0412 (\u0441\u0440\u0435\u0434\u043d\u0435\u043a\u0432\u0430\u0434\u0440.) \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u044f \u043a\u0430\u043d\u0430\u043b-\u043a\u0430\u043d\u0430\u043b<br \/>\nMeasure Current: 0 Arms to 5 Arms<\/p>","protected":false},"featured_media":31041,"template":"","meta":{"_acf_changed":false},"product_brand":[18],"product_cat":[673],"product_tag":[],"class_list":["post-32289","product","type-product","status-publish","has-post-thumbnail","product_brand-national-instruments","product_cat-c-module","first","instock","shipping-taxable","purchasable","product-type-simple"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.0 (Yoast SEO v27.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>NI-9227 C Series Current Input Module 781099-02 - Special Price<\/title>\n<meta name=\"description\" content=\"NI\u20119227 was designed to provide high-accuracy measurements to meet the demands of data acquisition and control applications - New &amp; Original\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/pxisource.com\/ru\/product\/ni-9227\/\" \/>\n<meta property=\"og:locale\" content=\"ru_RU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"NI-9227\" \/>\n<meta property=\"og:description\" content=\"NI\u20119227 was designed to provide high-accuracy measurements to meet the demands of data acquisition and control applications - New &amp; Original\" \/>\n<meta property=\"og:url\" content=\"https:\/\/pxisource.com\/ru\/product\/ni-9227\/\" \/>\n<meta property=\"og:site_name\" content=\"PXI Source\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=61582573040385\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-02T01:49:01+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/NI-9227.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"800\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u0426\u0435\u043d\u0430\" \/>\n\t<meta name=\"twitter:data1\" content=\"&#036;1,300.00\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c\" \/>\n\t<meta name=\"twitter:data2\" content=\"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/ni-9227\",\"url\":\"https:\\\/\\\/pxisource.com\\\/product\\\/ni-9227\",\"name\":\"NI-9227 C Series Current Input Module 781099-02 - Special Price\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/ni-9227#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/ni-9227#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/NI-9227.webp\",\"datePublished\":\"2026-04-27T01:18:54+00:00\",\"dateModified\":\"2026-07-02T01:49:01+00:00\",\"description\":\"NI\u20119227 was designed to provide high-accuracy measurements to meet the demands of data acquisition and control applications - New & Original\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/ni-9227#breadcrumb\"},\"inLanguage\":\"ru-RU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/pxisource.com\\\/product\\\/ni-9227\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/ni-9227#primaryimage\",\"url\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/NI-9227.webp\",\"contentUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/NI-9227.webp\",\"width\":800,\"height\":800,\"caption\":\"NI-9227\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/ni-9227#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/pxisource.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u5546\u5e97\",\"item\":\"https:\\\/\\\/pxisource.com\\\/shop\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"NI-9227\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\",\"url\":\"https:\\\/\\\/pxisource.com\\\/\",\"name\":\"essence instrument\",\"description\":\"Your Trusted Source for PXI, PXIe and Modular Instruments\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/pxisource.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ru-RU\"}]}<\/script>\n<meta property=\"product:price:amount\" content=\"1300.00\" \/>\n<meta property=\"product:price:currency\" content=\"USD\" \/>\n<meta property=\"og:availability\" content=\"instock\" \/>\n<meta property=\"product:availability\" content=\"instock\" \/>\n<meta property=\"product:condition\" content=\"new\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"NI-9227 C Series Current Input Module 781099-02 - Special Price","description":"NI\u20119227 was designed to provide high-accuracy measurements to meet the demands of data acquisition and control applications - New & Original","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/pxisource.com\/ru\/product\/ni-9227\/","og_locale":"ru_RU","og_type":"article","og_title":"NI-9227","og_description":"NI\u20119227 was designed to provide high-accuracy measurements to meet the demands of data acquisition and control applications - New & Original","og_url":"https:\/\/pxisource.com\/ru\/product\/ni-9227\/","og_site_name":"PXI Source","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=61582573040385","article_modified_time":"2026-07-02T01:49:01+00:00","og_image":[{"width":800,"height":800,"url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/NI-9227.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"\u0426\u0435\u043d\u0430":"&#36;1,300.00","\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c":"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/pxisource.com\/product\/ni-9227","url":"https:\/\/pxisource.com\/product\/ni-9227","name":"NI-9227 C Series Current Input Module 781099-02 - Special Price","isPartOf":{"@id":"https:\/\/pxisource.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/pxisource.com\/product\/ni-9227#primaryimage"},"image":{"@id":"https:\/\/pxisource.com\/product\/ni-9227#primaryimage"},"thumbnailUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/NI-9227.webp","datePublished":"2026-04-27T01:18:54+00:00","dateModified":"2026-07-02T01:49:01+00:00","description":"NI\u20119227 was designed to provide high-accuracy measurements to meet the demands of data acquisition and control applications - New & Original","breadcrumb":{"@id":"https:\/\/pxisource.com\/product\/ni-9227#breadcrumb"},"inLanguage":"ru-RU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/pxisource.com\/product\/ni-9227"]}]},{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/pxisource.com\/product\/ni-9227#primaryimage","url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/NI-9227.webp","contentUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/NI-9227.webp","width":800,"height":800,"caption":"NI-9227"},{"@type":"BreadcrumbList","@id":"https:\/\/pxisource.com\/product\/ni-9227#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/pxisource.com\/"},{"@type":"ListItem","position":2,"name":"\u5546\u5e97","item":"https:\/\/pxisource.com\/shop"},{"@type":"ListItem","position":3,"name":"NI-9227"}]},{"@type":"WebSite","@id":"https:\/\/pxisource.com\/#website","url":"https:\/\/pxisource.com\/","name":"\u0441\u0443\u0449\u043d\u043e\u0441\u0442\u044c \u0438\u043d\u0441\u0442\u0440\u0443\u043c\u0435\u043d\u0442\u0430","description":"Your Trusted Source for PXI, PXIe and Modular Instruments","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/pxisource.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ru-RU"}]},"product_price_amount":"1300.00","product_price_currency":"USD","og_availability":"instock","product_availability":"instock","product_condition":"new"},"_links":{"self":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/32289","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":4,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/32289\/revisions"}],"predecessor-version":[{"id":32966,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/32289\/revisions\/32966"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media\/31041"}],"wp:attachment":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media?parent=32289"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_brand?post=32289"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_cat?post=32289"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_tag?post=32289"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}