{"id":30485,"date":"2025-09-28T13:19:44","date_gmt":"2025-09-28T05:19:44","guid":{"rendered":"https:\/\/pxisource.com\/?post_type=product&#038;p=30485"},"modified":"2026-08-30T22:51:09","modified_gmt":"2026-08-30T14:51:09","slug":"pxi-5152","status":"publish","type":"product","link":"https:\/\/pxisource.com\/ru\/product\/pxi-5152\/","title":{"rendered":"PXI-5152"},"content":{"rendered":"<h3>PXI-5152 2 GS\/s 300 MHz 8-Bit PXI Oscilloscope<\/h3>\n<p>\u0417\u0435\u043c\u043b\u044f <strong>NI PXI-5152<\/strong> is a high-speed two-channel PXI oscilloscope and waveform digitizer designed for communications testing, fast transient acquisition, automated electronic validation and scientific measurements. It provides 8-bit vertical resolution, analog bandwidth up to 300 MHz and simultaneous real-time sampling at up to 1 GS\/s on both channels.<\/p>\n<p>When one channel is enabled, time-interleaved sampling increases the real-time sampling rate to 2 GS\/s. For stable repetitive signals, random-interleaved sampling provides effective rates up to 20 GS\/s. The PXI-5152 also offers selectable 50 \u03a9 or 1 M\u03a9 inputs, 100 mVpp to 10 Vpp ranges, advanced triggering and deep onboard memory.<\/p>\n<h3>Key Features of the PXI-5152<\/h3>\n<ul>\n<li>Two simultaneously sampled analog input channels<\/li>\n<li>8-bit vertical resolution<\/li>\n<li>1 GS\/s real-time sampling on both channels<\/li>\n<li>2 GS\/s real-time sampling in single-channel TIS mode<\/li>\n<li>Up to 20 GS\/s random-interleaved sampling for repetitive signals<\/li>\n<li>300 MHz analog input bandwidth<\/li>\n<li>Input ranges from 100 mVpp to 10 Vpp<\/li>\n<li>50 \u03a9 or 1 M\u03a9 selectable input impedance<\/li>\n<li>AC, DC and ground coupling<\/li>\n<li>Programmable vertical offset<\/li>\n<li>Software-selectable 20 MHz noise filter<\/li>\n<li>8 MB, 64 MB or 256 MB memory per channel<\/li>\n<li>Single-record and multiple-record acquisition<\/li>\n<li>Pretrigger and post-trigger waveform capture<\/li>\n<li>Edge, window, hysteresis and digital triggering<\/li>\n<li>External trigger and programmable function I\/O<\/li>\n<li>Channel-to-channel skew below 100 ps<\/li>\n<li>PXI Star Trigger and backplane trigger support<\/li>\n<li>NI-TClk multimodule synchronization<\/li>\n<li>Built-in self-calibration<\/li>\n<li>NI-SCOPE software support<\/li>\n<\/ul>\n<h3>PXI-5152 Technical Specifications<\/h3>\n<table>\n<tbody>\n<tr>\n<th>Product Model<\/th>\n<td>PXI-5152<\/td>\n<\/tr>\n<tr>\n<th>Product Type<\/th>\n<td>High-speed PXI oscilloscope and digitizer<\/td>\n<\/tr>\n<tr>\n<th>Analog Input Channels<\/th>\n<td>2<\/td>\n<\/tr>\n<tr>\n<th>Vertical Resolution<\/th>\n<td>8 bits<\/td>\n<\/tr>\n<tr>\n<th>Two-Channel Real-Time Sample Rate<\/th>\n<td>Up to 1 GS\/s per channel, simultaneously sampled<\/td>\n<\/tr>\n<tr>\n<th>Single-Channel Real-Time Sample Rate<\/th>\n<td>2 GS\/s using time-interleaved sampling<\/td>\n<\/tr>\n<tr>\n<th>Random-Interleaved Sample Rate<\/th>\n<td>2 GS\/s to 20 GS\/s for repetitive signals<\/td>\n<\/tr>\n<tr>\n<th>Maximum Analog Bandwidth<\/th>\n<td>300 MHz on most input ranges<\/td>\n<\/tr>\n<tr>\n<th>100 mV Range Bandwidth<\/th>\n<td>Reduced bandwidth compared with larger ranges<\/td>\n<\/tr>\n<tr>\n<th>Input Type<\/th>\n<td>Referenced single-ended<\/td>\n<\/tr>\n<tr>\n<th>Input Impedance<\/th>\n<td>50 \u03a9 or 1 M\u03a9<\/td>\n<\/tr>\n<tr>\n<th>1 M\u03a9 Input Capacitance<\/th>\n<td>Approximately 22 pF<\/td>\n<\/tr>\n<tr>\n<th>Input Voltage Ranges<\/th>\n<td>100 mVpp, 200 mVpp, 400 mVpp, 1 Vpp, 2 Vpp, 4 Vpp and 10 Vpp<\/td>\n<\/tr>\n<tr>\n<th>Input Coupling<\/th>\n<td>AC, DC or ground<\/td>\n<\/tr>\n<tr>\n<th>AC-Coupling Cutoff, 1 M\u03a9<\/th>\n<td>Approximately 12 Hz<\/td>\n<\/tr>\n<tr>\n<th>AC-Coupling Cutoff, 50 \u03a9<\/th>\n<td>Approximately 106 kHz<\/td>\n<\/tr>\n<tr>\n<th>Maximum 50 \u03a9 Input<\/th>\n<td>7 Vrms with peaks not exceeding 10 V<\/td>\n<\/tr>\n<tr>\n<th>Maximum 1 M\u03a9 Input<\/th>\n<td>Peak voltage not exceeding 42 V<\/td>\n<\/tr>\n<tr>\n<th>Bandwidth-Limit Filter<\/th>\n<td>20 MHz noise filter<\/td>\n<\/tr>\n<tr>\n<th>Typical Effective Number of Bits<\/th>\n<td>Up to approximately 7.3 bits with noise filter enabled<\/td>\n<\/tr>\n<tr>\n<th>Channel-to-Channel Skew<\/th>\n<td>Less than 100 ps<\/td>\n<\/tr>\n<tr>\n<th>Onboard Memory Options<\/th>\n<td>8 MB, 64 MB or 256 MB per channel<\/td>\n<\/tr>\n<tr>\n<th>Minimum Record Length<\/th>\n<td>1 sample<\/td>\n<\/tr>\n<tr>\n<th>Maximum Number of Records<\/th>\n<td>Up to 100,000, depending on memory configuration<\/td>\n<\/tr>\n<tr>\n<th>Analog Trigger Types<\/th>\n<td>Edge, window and hysteresis<\/td>\n<\/tr>\n<tr>\n<th>Digital Trigger Sources<\/th>\n<td>PXI trigger lines, PXI Star Trigger and front-panel PFI<\/td>\n<\/tr>\n<tr>\n<th>Typical Trigger Jitter<\/th>\n<td>10 ps RMS<\/td>\n<\/tr>\n<tr>\n<th>Analog Input Connectors<\/th>\n<td>2 \u00d7 BNC<\/td>\n<\/tr>\n<tr>\n<th>External Trigger Connector<\/th>\n<td>1 \u00d7 BNC<\/td>\n<\/tr>\n<tr>\n<th>PFI Connectors<\/th>\n<td>2 \u00d7 SMB<\/td>\n<\/tr>\n<tr>\n<th>Self-Calibration<\/th>\n<td>Gain, offset, triggering and timing calibration<\/td>\n<\/tr>\n<tr>\n<th>External Calibration Interval<\/th>\n<td>2 years<\/td>\n<\/tr>\n<tr>\n<th>Recommended Warm-Up Time<\/th>\n<td>15 minutes<\/td>\n<\/tr>\n<tr>\n<th>Software Driver<\/th>\n<td>NI-SCOPE<\/td>\n<\/tr>\n<tr>\n<th>\u0428\u0438\u043d\u043d\u044b\u0439 \u0438\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441<\/th>\n<td>PXI; compatible with supported PXI Express hybrid slots<\/td>\n<\/tr>\n<tr>\n<th>Module Format<\/th>\n<td>3U PXI module<\/td>\n<\/tr>\n<tr>\n<th>Maximum Power Consumption<\/th>\n<td>Approximately 21.65 W<\/td>\n<\/tr>\n<tr>\n<th>Operating Temperature<\/th>\n<td>0\u00b0C to 55\u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>PXI-5152 Part Numbers and Memory Options<\/h3>\n<table>\n<tbody>\n<tr>\n<th>Product Configuration<\/th>\n<th>Part Number<\/th>\n<th>Onboard Memory<\/th>\n<\/tr>\n<tr>\n<td>PXI-5152 Standard Memory<\/td>\n<td>779772-01<\/td>\n<td>8 MB per channel<\/td>\n<\/tr>\n<tr>\n<td>PXI-5152 Extended Memory<\/td>\n<td>779772-02<\/td>\n<td>64 MB per channel<\/td>\n<\/tr>\n<tr>\n<td>PXI-5152 Deep Memory<\/td>\n<td>779772-03<\/td>\n<td>256 MB per channel<\/td>\n<\/tr>\n<tr>\n<td>50 \u03a9 BNC Cable<\/td>\n<td>Configuration dependent<\/td>\n<td>Coaxial cable for high-speed impedance-matched measurements<\/td>\n<\/tr>\n<tr>\n<td>Passive Oscilloscope Probe<\/td>\n<td>Configuration dependent<\/td>\n<td>Probe for high-impedance general-purpose measurements<\/td>\n<\/tr>\n<tr>\n<td>SMB Trigger Cable<\/td>\n<td>Configuration dependent<\/td>\n<td>Cable for PFI triggering and external timing connections<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The three PXI-5152 versions provide the same principal channel count, sampling rate, resolution and bandwidth. Their primary difference is the amount of onboard acquisition memory installed for each channel.<\/p>\n<h3>Dual 1 GS\/s Simultaneous Inputs<\/h3>\n<p>With both channels enabled, each input samples at up to 1 GS\/s. The simultaneous architecture preserves phase and timing relationships between the two measured signals.<\/p>\n<p>This is useful for comparing device input and output signals, measuring propagation delay, analyzing differential timing and capturing related transient events.<\/p>\n<h3>2 GS\/s Single-Channel Sampling<\/h3>\n<p>When only one channel is required, the PXI-5152 combines its ADC resources in time-interleaved sampling mode to provide a real-time rate of 2 GS\/s.<\/p>\n<p>TIS mode is appropriate for nonrepetitive high-speed events because it captures the waveform in a single occurrence. Confirm the selected channel and mode in NI-SCOPE before configuring a 2 GS\/s acquisition.<\/p>\n<h3>20 GS\/s Random-Interleaved Sampling<\/h3>\n<p>For stable repetitive signals, random-interleaved sampling provides effective sample rates from 2 GS\/s to 20 GS\/s. The module combines samples from repeated waveform cycles to create finer time spacing.<\/p>\n<p>RIS should not be used for single-shot, modulated or changing events because it assumes that successive waveform repetitions are substantially identical.<\/p>\n<h3>300 MHz Analog Bandwidth<\/h3>\n<p>The PXI-5152 provides at least 300 MHz bandwidth on most input ranges, with higher typical bandwidth on the 50 \u03a9 signal path. This supports high-speed digital signals, communications waveforms, pulses and fast electronic transients.<\/p>\n<p>The smallest 100 mVpp range has reduced bandwidth. Check the range-specific specification when both maximum sensitivity and maximum frequency response are required.<\/p>\n<h3>8-Bit Vertical Resolution<\/h3>\n<p>The ADC provides 256 theoretical amplitude levels across the selected range. Its architecture prioritizes high-speed waveform capture and precise timing rather than very-high-resolution DC measurement.<\/p>\n<p>Selecting the smallest range that safely contains the waveform improves amplitude sensitivity. Allow margin for noise, DC offset, overshoot and ringing.<\/p>\n<h3>Input Ranges from 100 mVpp to 10 Vpp<\/h3>\n<p>The PXI-5152 offers seven ranges from 100 mVpp to 10 Vpp. Each channel can be configured independently according to its signal amplitude.<\/p>\n<p>Programmable offset allows a smaller input range to be positioned around a nonzero voltage, improving the visibility of ripple or transient behavior on a DC level.<\/p>\n<h3>50 \u03a9 Input Impedance<\/h3>\n<p>The 50 \u03a9 path is optimized for impedance-matched signal generators, RF-style sources and high-speed coaxial measurement systems. Matching the source, cable and digitizer reduces reflections.<\/p>\n<p>Observe the lower overload limits of the terminated input. Excessive voltage can activate protection or permanently damage the internal termination.<\/p>\n<h3>1 M\u03a9 Input Impedance<\/h3>\n<p>The 1 M\u03a9 path reduces loading on high-impedance circuits and supports conventional passive oscilloscope probes. Its approximately 22 pF input capacitance affects loading at higher frequencies.<\/p>\n<p>Use a compensated probe with a short ground connection to minimize ringing, pickup and distortion.<\/p>\n<h3>AC, DC and Ground Coupling<\/h3>\n<p>DC coupling preserves the complete waveform, including its DC level. AC coupling blocks the DC component and helps measure ripple or noise on top of a larger DC voltage.<\/p>\n<p>The low-frequency cutoff is approximately 12 Hz in 1 M\u03a9 mode and significantly higher in 50 \u03a9 mode. Ground coupling provides an internal baseline reference.<\/p>\n<h3>20 MHz Noise Filter<\/h3>\n<p>A software-selectable 20 MHz bandwidth filter reduces broadband noise when high-frequency content is not required. It can improve effective resolution and measurement stability for lower-frequency signals.<\/p>\n<p>Disable the filter when capturing fast edges or signal components above 20 MHz.<\/p>\n<h3>Deep Onboard Memory<\/h3>\n<p>The PXI-5152 is available with 8 MB, 64 MB or 256 MB of memory per channel. Deep memory permits longer waveform records at high sampling rates.<\/p>\n<p>In 2 GS\/s single-channel TIS mode, the memory is used by the active channel. In conventional real-time or RIS operation, memory is available independently to the enabled channels.<\/p>\n<h3>Multiple-Record Acquisition<\/h3>\n<p>Multiple-record mode captures separate waveform segments associated with individual trigger events. Hardware rearming prepares the digitizer rapidly for each subsequent event.<\/p>\n<p>The 64 MB and 256 MB configurations can store up to 100,000 records under supported record-length conditions.<\/p>\n<h3>Pretrigger and Post-Trigger Acquisition<\/h3>\n<p>Pretrigger data shows signal behavior before the trigger condition, while post-trigger samples capture what happens afterward. The trigger can be positioned anywhere within the supported record.<\/p>\n<p>This is useful for diagnosing intermittent faults and identifying events that occurred immediately before a threshold crossing or failure.<\/p>\n<h3>Advanced Analog Triggering<\/h3>\n<p>Edge triggering starts an acquisition when a signal crosses a selected voltage level. Window triggering detects when a signal enters or exits a defined band, while hysteresis improves stability for noisy transitions.<\/p>\n<p>The external trigger input provides AC or DC coupling and a high-impedance connection for external trigger signals.<\/p>\n<h3>Digital Triggering and PFI<\/h3>\n<p>Digital trigger sources include PXI trigger lines, the PXI Star Trigger and front-panel PFI connections. The two PFI connectors can be configured for trigger input, event output and other timing functions.<\/p>\n<p>PFI outputs can indicate the start or end of an acquisition, end of a record or another supported instrument event.<\/p>\n<h3>Low Trigger Jitter<\/h3>\n<p>Typical trigger jitter is approximately 10 ps RMS, with a specified maximum of 20 ps RMS under supported conditions. Low jitter improves the repeatability of high-speed edge and timing measurements.<\/p>\n<p>Total system timing uncertainty also includes sample-clock jitter, signal noise, trigger slew rate and synchronization error.<\/p>\n<h3>PXI and NI-TClk Synchronization<\/h3>\n<p>The PXI-5152 can use PXI trigger lines, the Star Trigger and the PXI reference clock for coordination with other modules. NI-TClk technology aligns compatible instruments for phase-coherent acquisition.<\/p>\n<p>Multiple PXI-5152 modules can be combined to create higher-channel-count systems while maintaining subnanosecond timing relationships.<\/p>\n<h3>Built-In Self-Calibration<\/h3>\n<p>Software-controlled self-calibration compensates for gain, offset, triggering and timing errors at the current operating temperature. A 15-minute warm-up period is recommended.<\/p>\n<p>External calibration adjusts the internal timing and voltage references. NI recommends a two-year external calibration interval.<\/p>\n<h3>Communications Testing<\/h3>\n<p>The 300 MHz bandwidth and 50 \u03a9 input path support baseband, intermediate-frequency and communications waveform acquisition. Software can calculate spectral content, power, timing and modulation-related parameters.<\/p>\n<p>For measurements requiring higher dynamic range or onboard digital downconversion, consider a dedicated communications digitizer such as the PXI-5142 or PXIe-5622.<\/p>\n<h3>High-Speed Digital Testing<\/h3>\n<p>The PXI-5152 can capture clock signals, pulse trains and other digital waveforms for rise-time, fall-time, overshoot, ringing and propagation-delay analysis.<\/p>\n<p>Use controlled-impedance connections and appropriate probes because the measurement fixture can significantly affect fast signal edges.<\/p>\n<h3>Radar and Pulsed-Signal Acquisition<\/h3>\n<p>Deep memory, multiple-record acquisition and rapid trigger rearming make the PXI-5152 useful for capturing radar, sonar and other pulsed events.<\/p>\n<p>Instead of storing inactive time between pulses, multiple-record mode retains only the waveform region surrounding each trigger.<\/p>\n<h3>Power Electronics Testing<\/h3>\n<p>The module can acquire gate-drive, control, isolated voltage-probe and current-sensor signals from converters, inverters and motor-control systems.<\/p>\n<p>Because the inputs are referenced to chassis ground, appropriate differential probes or isolated transducers are required for floating or high-voltage measurements.<\/p>\n<h3>Scientific and Research Measurements<\/h3>\n<p>The PXI-5152 can acquire detector outputs, optical pulses, ultrasonic waveforms and other fast experimental signals. Its deep memory supports long records or large numbers of events.<\/p>\n<p>External timing inputs can synchronize the acquisition with a laser, pulser, mechanical system or other experimental hardware.<\/p>\n<h3>Automated Production Testing<\/h3>\n<p>NI-SCOPE enables software-defined waveform measurements for production systems. Test programs can calculate amplitude, frequency, rise time, pulse width and other parameters automatically.<\/p>\n<p>PXI synchronization coordinates the digitizer with signal generators, switches and digital instruments to improve throughput and repeatability.<\/p>\n<h3>NI-SCOPE Software Support<\/h3>\n<p>The PXI-5152 is controlled through the IVI-compliant NI-SCOPE driver. NI-SCOPE provides functions for configuring ranges, coupling, impedance, sampling, triggering, memory and synchronization.<\/p>\n<p>The driver supports LabVIEW, LabWindows\/CVI, Measurement Studio and compatible C, C++ and .NET environments. The NI-SCOPE soft front panel provides interactive control and waveform display.<\/p>\n<h3>Typical PXI-5152 Applications<\/h3>\n<ul>\n<li>High-speed transient acquisition<\/li>\n<li>Automated oscilloscope measurements<\/li>\n<li>Communications waveform testing<\/li>\n<li>High-speed digital validation<\/li>\n<li>Pulse and timing analysis<\/li>\n<li>Radar and sonar testing<\/li>\n<li>Power electronics measurements<\/li>\n<li>Aerospace and defense validation<\/li>\n<li>Scientific research<\/li>\n<li>Ultrasonic signal acquisition<\/li>\n<li>Consumer electronics testing<\/li>\n<li>Production functional testing<\/li>\n<li>Multiple-record event capture<\/li>\n<li>Synchronized mixed-signal testing<\/li>\n<li>High-channel-count PXI acquisition systems<\/li>\n<\/ul>\n<h3>PXI-5152 Troubleshooting<\/h3>\n<h4>The PXI-5152 is not detected in NI MAX<\/h4>\n<p>Confirm that the module is fully installed in a compatible PXI or PXI Express hybrid slot. Check chassis power, controller communication and NI-SCOPE installation, then restart NI Measurement &amp; Automation Explorer.<\/p>\n<h4>The maximum rate is only 1 GS\/s<\/h4>\n<p>With both channels enabled, the maximum rate is 1 GS\/s per channel. Disable the unused channel and enable time-interleaved sampling to acquire one channel at 2 GS\/s.<\/p>\n<h4>The acquired waveform is clipped<\/h4>\n<p>Select a larger input range or adjust the vertical offset. Verify that the complete signal, including DC offset, noise and overshoot, remains within the configured range.<\/p>\n<h4>The measured amplitude is incorrect<\/h4>\n<p>Check input impedance and source termination. A generator calibrated for a 50 \u03a9 load can produce approximately twice its indicated open-circuit voltage when connected to a 1 M\u03a9 input.<\/p>\n<h4>The signal contains reflections<\/h4>\n<p>Use 50 \u03a9 coaxial cables and matching termination for high-frequency sources. Remove unterminated branches and minimize adapters or fixture discontinuities.<\/p>\n<h4>RIS produces an unstable waveform<\/h4>\n<p>Random-interleaved sampling requires a stable repetitive signal. Use 1 GS\/s dual-channel or 2 GS\/s single-channel real-time acquisition for nonrepetitive events.<\/p>\n<h4>The trigger is unstable<\/h4>\n<p>Review the trigger source, level, slope, coupling and hysteresis. Confirm that the trigger signal crosses the threshold with sufficient slew rate.<\/p>\n<h4>The 100 mV range does not reach 300 MHz<\/h4>\n<p>The smallest input range has reduced analog bandwidth. Select a larger range or add an appropriate external low-noise amplifier when both sensitivity and bandwidth are required.<\/p>\n<h4>Multiple modules are not synchronized<\/h4>\n<p>Confirm that all modules share the same reference clock and trigger source. Configure the NI-TClk group, clock master and trigger routing correctly.<\/p>\n<h3>PXI-5152 Comparison with Similar PXI Oscilloscopes<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u041c\u043e\u0434\u0435\u043b\u044c<\/th>\n<th>Primary Configuration<\/th>\n<th>Best Suited For<\/th>\n<\/tr>\n<tr>\n<td>PXI-5114<\/td>\n<td>2 channels, 8-bit, 250 MS\/s, 125 MHz<\/td>\n<td>General-purpose high-speed PXI waveform acquisition<\/td>\n<\/tr>\n<tr>\n<td>PXI-5124<\/td>\n<td>2 channels, 12-bit, 200 MS\/s, 150 MHz<\/td>\n<td>Improved amplitude resolution with moderate bandwidth<\/td>\n<\/tr>\n<tr>\n<td>PXI-5142<\/td>\n<td>2 channels, 14-bit, 100 MS\/s, 100 MHz with onboard DDC<\/td>\n<td>Communications and complex I\/Q measurements<\/td>\n<\/tr>\n<tr>\n<td>PXI-5152<\/td>\n<td>2 channels, 8-bit, 1 GS\/s dual-channel or 2 GS\/s single-channel, 300 MHz<\/td>\n<td>Fast transient, pulse and communications waveform capture<\/td>\n<\/tr>\n<tr>\n<td>PXI-5153<\/td>\n<td>2 channels, 8-bit, higher bandwidth and sampling capability<\/td>\n<td>Faster signals requiring additional bandwidth<\/td>\n<\/tr>\n<tr>\n<td>PXIe-5160<\/td>\n<td>2 channels, 10-bit, 2.5 GS\/s, 500 MHz<\/td>\n<td>Modern PXI Express systems requiring higher resolution and bandwidth<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>PXI-5152 vs PXI-5124<\/h3>\n<p>The PXI-5152 provides substantially higher sampling speed and bandwidth, with 1 GS\/s per channel, 2 GS\/s in single-channel mode and 300 MHz bandwidth. The <a href=\"https:\/\/pxisource.com\/ru\/product\/pxi-5124\/\">PXI-5124<\/a> provides higher 12-bit resolution but is limited to 200 MS\/s and 150 MHz.<\/p>\n<p>Choose the PXI-5152 for faster transient and timing measurements. Select the PXI-5124 when amplitude resolution is more important than maximum speed.<\/p>\n<h3>PXI-5152 vs PXI-5142<\/h3>\n<p>The PXI-5152 offers higher sampling speed and bandwidth with 8-bit resolution. The <a href=\"https:\/\/pxisource.com\/ru\/product\/pxi-5142\/\">PXI-5142<\/a> provides 14-bit resolution, 100 MS\/s sampling and onboard digital downconversion.<\/p>\n<p>Select the PXI-5152 for broadband waveform and pulse acquisition. Choose the PXI-5142 for narrowband communications, high-dynamic-range and complex I\/Q measurements.<\/p>\n<h3>PXI-5152 vs PXIe-5160<\/h3>\n<p>The PXIe-5160 provides 10-bit resolution, 2.5 GS\/s simultaneous sampling and approximately 500 MHz bandwidth through a PXI Express interface. The PXI-5152 provides 8-bit resolution and 300 MHz bandwidth through a conventional PXI interface.<\/p>\n<p>Choose the PXI-5152 for maintaining existing PXI systems. Consider the <a href=\"https:\/\/pxisource.com\/ru\/product\/pxie-5160\/\">PXIe-5160<\/a> for newer systems requiring improved resolution, bandwidth and backplane throughput.<\/p>\n<h3>Recommended Related Products<\/h3>\n<ul>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxi-5114\/\">PXI-5114 250 MS\/s PXI Oscilloscope<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxi-5124\/\">PXI-5124 12-Bit 200 MS\/s Digitizer<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxi-5142\/\">PXI-5142 14-Bit Communications Digitizer<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxi-5153\/\">PXI-5153 High-Speed PXI Oscilloscope<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxi-5154\/\">PXI-5154 High-Speed PXI Oscilloscope<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxie-5160\/\">PXIe-5160 2.5 GS\/s PXI Express Oscilloscope<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxie-5162\/\">PXIe-5162 High-Speed PXI Express Oscilloscope<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product-category\/%d0%bd%d0%b8\/pxi-%d1%81%d0%b8%d1%81%d1%82%d0%b5%d0%bc%d1%81\/%d0%bc%d0%be%d0%b4%d1%83%d0%bb%d0%b8-pxi\/\">View More NI PXI Oscilloscopes and Digitizers<\/a><\/li>\n<\/ul>\n<h3>Selecting the Right PXI Oscilloscope<\/h3>\n<p>Choose the PXI-5152 when the application requires two 1 GS\/s channels, 2 GS\/s single-channel capture, 300 MHz bandwidth and deep acquisition memory. It is well suited for timing, pulse, communications and fast transient measurements.<\/p>\n<p>Select a 12-bit or 14-bit digitizer when amplitude resolution and dynamic range are more important. Consider a newer PXI Express oscilloscope when additional bandwidth, resolution or sustained streaming performance is required.<\/p>\n<p>Choose the 8 MB version for shorter records, the 64 MB version for medium-length acquisitions and the 256 MB version for long captures or large multiple-record tests.<\/p>\n<h3>Why Choose the PXI-5152?<\/h3>\n<ul>\n<li>Provides two simultaneous 1 GS\/s input channels<\/li>\n<li>Supports 2 GS\/s single-channel real-time sampling<\/li>\n<li>Offers 20 GS\/s RIS for repetitive signals<\/li>\n<li>Provides up to 300 MHz analog bandwidth<\/li>\n<li>Supports 50 \u03a9 and 1 M\u03a9 signal sources<\/li>\n<li>Offers input ranges from 100 mVpp to 10 Vpp<\/li>\n<li>Provides up to 256 MB memory per channel<\/li>\n<li>Supports low-jitter analog and digital triggering<\/li>\n<li>Provides PXI and NI-TClk synchronization<\/li>\n<li>Integrates with NI-SCOPE and LabVIEW<\/li>\n<\/ul>\n<h3>Frequently Asked Questions<\/h3>\n<h4>What is the PXI-5152?<\/h4>\n<p>The PXI-5152 is a two-channel, 8-bit PXI oscilloscope with 300 MHz bandwidth, 1 GS\/s simultaneous sampling per channel and 2 GS\/s single-channel real-time sampling.<\/p>\n<h4>Can both channels sample at 2 GS\/s?<\/h4>\n<p>No. With both channels enabled, the maximum rate is 1 GS\/s per channel. The 2 GS\/s real-time rate is available in single-channel time-interleaved mode.<\/p>\n<h4>What is the maximum equivalent-time sampling rate?<\/h4>\n<p>Random-interleaved sampling provides effective rates up to 20 GS\/s for stable repetitive signals.<\/p>\n<h4>What is the analog bandwidth?<\/h4>\n<p>The maximum analog bandwidth is 300 MHz on most input ranges. The 100 mVpp range has reduced bandwidth.<\/p>\n<h4>What input ranges are available?<\/h4>\n<p>The module provides full-scale input ranges from 100 mVpp to 10 Vpp.<\/p>\n<h4>Which input impedances are supported?<\/h4>\n<p>Each channel supports software-selectable 50 \u03a9 or 1 M\u03a9 input impedance.<\/p>\n<h4>Which part number has 8 MB per channel?<\/h4>\n<p>Part number <strong>779772-01<\/strong> provides 8 MB of onboard memory per channel.<\/p>\n<h4>Which part number has 64 MB per channel?<\/h4>\n<p>Part number <strong>779772-02<\/strong> provides 64 MB of onboard memory per channel.<\/p>\n<h4>Which part number has 256 MB per channel?<\/h4>\n<p>Part number <strong>779772-03<\/strong> provides 256 MB of onboard memory per channel.<\/p>\n<h4>Can multiple PXI-5152 modules be synchronized?<\/h4>\n<p>Yes. Multiple compatible modules can share PXI clocks and triggers through NI-TClk synchronization.<\/p>\n<h4>Which driver controls the PXI-5152?<\/h4>\n<p>The PXI-5152 is controlled through the NI-SCOPE instrument driver.<\/p>\n<h4>Can the PXI-5152 operate in a PXI Express chassis?<\/h4>\n<p>Yes. It can operate in a compatible PXI Express hybrid peripheral slot, but not in a PXI Express-only slot without the hybrid connector.<\/p>\n<h3>Request a Quote for the PXI-5152<\/h3>\n<p>Contact us for current availability, memory configuration, product condition, calibration status, lead time and project pricing for the <strong>PXI-5152 2 GS\/s 300 MHz 8-Bit PXI Oscilloscope<\/strong>. We can also help identify compatible probes, BNC cables, PXI chassis, controllers and related high-speed digitizers.<\/p>","protected":false},"excerpt":{"rendered":"<p>PXI-5152 2 GS\/s 300 MHz 8-Bit PXI Oscilloscope The NI PXI-5152 is a high-speed two-channel PXI oscilloscope and waveform digitizer<\/p>","protected":false},"featured_media":31223,"template":"","meta":{"_acf_changed":false},"product_brand":[18],"product_cat":[667],"product_tag":[],"class_list":["post-30485","product","type-product","status-publish","has-post-thumbnail","product_brand-national-instruments","product_cat-pxi-modules","first","instock","shipping-taxable","product-type-simple"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.0 (Yoast SEO v28.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>NI PXI-5152 PXI Oscilloscope 779772-03, In Stock | Project Pricing<\/title>\n<meta name=\"description\" content=\"The PXI-5152 is a 2-channel, 8-bit PXI oscilloscope with 300 MHz bandwidth, 1 GS\/s simultaneous and 2 GS\/s single-channel sampling.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/pxisource.com\/ru\/product\/pxi-5152\/\" \/>\n<meta property=\"og:locale\" content=\"ru_RU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"PXI-5152\" \/>\n<meta property=\"og:description\" content=\"The PXI-5152 is a 2-channel, 8-bit PXI oscilloscope with 300 MHz bandwidth, 1 GS\/s simultaneous and 2 GS\/s single-channel sampling.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/pxisource.com\/ru\/product\/pxi-5152\/\" \/>\n<meta property=\"og:site_name\" content=\"PXI Source\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=61582573040385\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-30T14:51:09+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PXI-5152.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"650\" \/>\n\t<meta property=\"og:image:height\" content=\"650\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u0426\u0435\u043d\u0430\" \/>\n\t<meta name=\"twitter:data1\" content=\"\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c\" \/>\n\t<meta name=\"twitter:data2\" content=\"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxi-5152\\\/\",\"url\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxi-5152\\\/\",\"name\":\"NI PXI-5152 PXI Oscilloscope 779772-03, In Stock | Project Pricing\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxi-5152\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxi-5152\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/PXI-5152.webp\",\"datePublished\":\"2025-09-28T05:19:44+00:00\",\"dateModified\":\"2026-08-30T14:51:09+00:00\",\"description\":\"The PXI-5152 is a 2-channel, 8-bit PXI oscilloscope with 300 MHz bandwidth, 1 GS\\\/s simultaneous and 2 GS\\\/s single-channel sampling.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxi-5152\\\/#breadcrumb\"},\"inLanguage\":\"ru-RU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/pxisource.com\\\/product\\\/pxi-5152\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxi-5152\\\/#primaryimage\",\"url\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/PXI-5152.webp\",\"contentUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/PXI-5152.webp\",\"width\":650,\"height\":650,\"caption\":\"PXI-5152\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxi-5152\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/pxisource.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\\\/\\\/pxisource.com\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"PXI-5152\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\",\"url\":\"https:\\\/\\\/pxisource.com\\\/\",\"name\":\"PXI Systems\",\"description\":\"NI PXI, PXIe Modular Test Instrument Supplier\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/pxisource.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ru-RU\"}]}<\/script>\n<meta property=\"product:brand\" content=\"National Instruments\" \/>\n<meta property=\"product:price:currency\" content=\"USD\" \/>\n<meta property=\"og:availability\" content=\"instock\" \/>\n<meta property=\"product:availability\" content=\"instock\" \/>\n<meta property=\"product:condition\" content=\"new\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"NI PXI-5152 PXI Oscilloscope 779772-03, In Stock | Project Pricing","description":"The PXI-5152 is a 2-channel, 8-bit PXI oscilloscope with 300 MHz bandwidth, 1 GS\/s simultaneous and 2 GS\/s single-channel sampling.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/pxisource.com\/ru\/product\/pxi-5152\/","og_locale":"ru_RU","og_type":"article","og_title":"PXI-5152","og_description":"The PXI-5152 is a 2-channel, 8-bit PXI oscilloscope with 300 MHz bandwidth, 1 GS\/s simultaneous and 2 GS\/s single-channel sampling.","og_url":"https:\/\/pxisource.com\/ru\/product\/pxi-5152\/","og_site_name":"PXI Source","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=61582573040385","article_modified_time":"2026-08-30T14:51:09+00:00","og_image":[{"width":650,"height":650,"url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PXI-5152.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"\u0426\u0435\u043d\u0430":"","\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c":"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/pxisource.com\/product\/pxi-5152\/","url":"https:\/\/pxisource.com\/product\/pxi-5152\/","name":"NI PXI-5152 PXI Oscilloscope 779772-03, In Stock | Project Pricing","isPartOf":{"@id":"https:\/\/pxisource.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/pxisource.com\/product\/pxi-5152\/#primaryimage"},"image":{"@id":"https:\/\/pxisource.com\/product\/pxi-5152\/#primaryimage"},"thumbnailUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PXI-5152.webp","datePublished":"2025-09-28T05:19:44+00:00","dateModified":"2026-08-30T14:51:09+00:00","description":"The PXI-5152 is a 2-channel, 8-bit PXI oscilloscope with 300 MHz bandwidth, 1 GS\/s simultaneous and 2 GS\/s single-channel sampling.","breadcrumb":{"@id":"https:\/\/pxisource.com\/product\/pxi-5152\/#breadcrumb"},"inLanguage":"ru-RU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/pxisource.com\/product\/pxi-5152\/"]}]},{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/pxisource.com\/product\/pxi-5152\/#primaryimage","url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PXI-5152.webp","contentUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PXI-5152.webp","width":650,"height":650,"caption":"PXI-5152"},{"@type":"BreadcrumbList","@id":"https:\/\/pxisource.com\/product\/pxi-5152\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/pxisource.com\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/pxisource.com\/shop\/"},{"@type":"ListItem","position":3,"name":"PXI-5152"}]},{"@type":"WebSite","@id":"https:\/\/pxisource.com\/#website","url":"https:\/\/pxisource.com\/","name":"\u0421\u0438\u0441\u0442\u0435\u043c\u044b PXI","description":"NI PXI, PXIe Modular Test Instrument Supplier","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/pxisource.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ru-RU"}]},"product_brand":"National Instruments","product_price_currency":"USD","og_availability":"instock","product_availability":"instock","product_condition":"new"},"_links":{"self":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/30485","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":4,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/30485\/revisions"}],"predecessor-version":[{"id":35782,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/30485\/revisions\/35782"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media\/31223"}],"wp:attachment":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media?parent=30485"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_brand?post=30485"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_cat?post=30485"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_tag?post=30485"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}