{"id":29972,"date":"2025-09-23T14:17:07","date_gmt":"2025-09-23T06:17:07","guid":{"rendered":"https:\/\/pxisource.com\/?post_type=product&#038;p=29972"},"modified":"2026-09-11T12:49:03","modified_gmt":"2026-09-11T04:49:03","slug":"pxi-1036","status":"publish","type":"product","link":"https:\/\/pxisource.com\/ru\/product\/pxi-1036\/","title":{"rendered":"\u041f\u0425\u0418-1036"},"content":{"rendered":"<h3>PXI-1036 6-Slot Universal AC PXI Chassis<\/h3>\n<p>\u0417\u0435\u043c\u043b\u044f <strong>NI PXI-1036<\/strong> is a compact six-slot, 3U PXI chassis developed for remote-control, real-time, data acquisition and automated test applications. It provides one system-controller slot and five PXI peripheral slots in the same compact enclosure format used by the four-slot PXI-1031.<\/p>\n<p>The PXI-1036 supports compatible remote-control interfaces and one- or two-slot embedded PXI controllers. This controller arrangement preserves five positions for measurement, switching, communication and control modules while maintaining a small bench-top footprint.<\/p>\n<p>With a <strong>300 W universal AC power supply<\/strong>, 132 MB\/s maximum conventional PXI bandwidth, 25 W per-slot cooling, low-noise AUTO fan operation and integrated PXI timing resources, the PXI-1036 provides a flexible platform for compact automated test systems.<\/p>\n<p>The PXI-1036 is a conventional PCI-based PXI chassis. It does not contain native PXI Express or hybrid peripheral slots and should not be confused with the AC\/DC-powered PXI-1036DC.<\/p>\n<h3>Key Features of the PXI-1036<\/h3>\n<ul>\n<li>Six-slot 3U PXI chassis<\/li>\n<li>One PXI system-controller slot<\/li>\n<li>Five PXI peripheral slots<\/li>\n<li>One controller expansion position<\/li>\n<li>Compatible with one- and two-slot PXI embedded controllers<\/li>\n<li>Supports compatible PXI remote-control interfaces<\/li>\n<li>132 MB\/s maximum system bandwidth<\/li>\n<li>32-bit conventional PCI backplane<\/li>\n<li>300 W universal AC power supply<\/li>\n<li>100\u2013240 VAC nominal input range<\/li>\n<li>25 W cooling capacity per slot<\/li>\n<li>86 cfm module-cooling fan<\/li>\n<li>AUTO and HIGH fan-speed modes<\/li>\n<li>40.7 dBA sound-pressure level in AUTO mode<\/li>\n<li>Dedicated star-trigger functionality in slot 2<\/li>\n<li>Eight PXI trigger lines<\/li>\n<li>Thirteen-line local bus between adjacent slots<\/li>\n<li>Low-skew 10 MHz PXI reference clock<\/li>\n<li>Compatible with supported 3U PXI and CompactPCI modules<\/li>\n<li>Optional rack-mount, handle and rubber-feet kits<\/li>\n<li>0\u00b0C to 50\u00b0C operating-temperature range<\/li>\n<li>30 g operational shock rating<\/li>\n<\/ul>\n<h3>Compact Six-Slot Architecture<\/h3>\n<p>The PXI-1036 combines six physical backplane slots with a chassis measuring only 177 \u00d7 257.1 \u00d7 212.8 mm. Its compact size makes it suitable for portable laboratory systems, space-constrained test benches and smaller automated test stations.<\/p>\n<p>Slot 1 is reserved for the PXI system controller. Slots 2 through 6 are available for peripheral modules, with slot 2 also serving as the star-trigger position.<\/p>\n<p>The chassis has one controller expansion position to the left of slot 1. It can therefore accommodate a two-slot embedded controller without sacrificing any of the five peripheral slots.<\/p>\n<h3>Designed for Remote-Control Systems<\/h3>\n<p>The PXI-1036 was designed primarily for compact remote-control configurations. A compatible PXI remote-control interface can connect the chassis to a desktop computer through an appropriate MXI interface.<\/p>\n<p>NI documented support for remote-controller families including MXI-4 and MXI-Express. The precise host interface, PXI module and cable must be compatible with one another and with the operating system used by the host computer.<\/p>\n<p>A remote-control architecture allows the computer to be upgraded or serviced separately from the PXI instrumentation. It can also reduce the heat generated inside the chassis because the system uses a compact interface module instead of a higher-power embedded controller.<\/p>\n<h3>Support for Compact Embedded Controllers<\/h3>\n<p>In addition to remote control, the PXI-1036 accepts compatible one- or two-slot embedded PXI controllers. This allows the chassis to operate as a compact self-contained test system without a separate desktop host.<\/p>\n<p>A two-slot controller uses the system slot and the dedicated controller expansion position. It does not consume one of the five peripheral positions.<\/p>\n<p>Controllers wider than two slots are not suitable for the PXI-1036 architecture. Confirm controller width, conventional PXI compatibility, power consumption and operating-system support before installation.<\/p>\n<h3>Conventional PXI Backplane<\/h3>\n<p>The PXI-1036 uses a 32-bit conventional PCI backplane with maximum system bandwidth of <strong>132 MB\/s<\/strong>. This bandwidth is shared among the system controller and installed peripheral modules.<\/p>\n<p>The architecture supports many DAQ, switching, digital multimeter, communication and signal-generation applications. However, it does not provide the multi-gigabyte-per-second data paths available from modern PXI Express chassis.<\/p>\n<p>Compatible 64-bit CompactPCI modules can operate in the chassis, but the PXI-1036 backplane limits them to 32-bit PCI operation.<\/p>\n<h3>PXI and CompactPCI Compatibility<\/h3>\n<p>The PXI-1036 supports compatible 3U PXI and CompactPCI modules. Its backplane is designed for 5 V and universal PXI-compatible products, with V(I\/O) connected to the +5 V plane.<\/p>\n<p>PXI instruments can use the timing, triggering and local-bus resources provided by the chassis. Standard CompactPCI devices can use the applicable PCI and power connections but may not implement PXI-specific synchronization features.<\/p>\n<p>PXI Express-only modules cannot be installed because the PXI-1036 does not provide PXIe or PXI Express hybrid connectors.<\/p>\n<h2>PXI-1036 Technical Specifications<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Product Model<\/th>\n<td>\u041f\u0425\u0418-1036<\/td>\n<\/tr>\n<tr>\n<th>Part Number<\/th>\n<td>779382-01<\/td>\n<\/tr>\n<tr>\n<th>Product Type<\/th>\n<td>Six-slot universal AC PXI chassis<\/td>\n<\/tr>\n<tr>\n<th>Chassis Form Factor<\/th>\n<td>3U PXI<\/td>\n<\/tr>\n<tr>\n<th>Total Physical Slots<\/th>\n<td>6<\/td>\n<\/tr>\n<tr>\n<th>System-Controller Slots<\/th>\n<td>1<\/td>\n<\/tr>\n<tr>\n<th>Controller Expansion Positions<\/th>\n<td>1 position to the left of the controller slot<\/td>\n<\/tr>\n<tr>\n<th>Supported Embedded Controller Width<\/th>\n<td>One or two slots<\/td>\n<\/tr>\n<tr>\n<th>Peripheral Slots<\/th>\n<td>5, including the star-trigger slot<\/td>\n<\/tr>\n<tr>\n<th>Star-Trigger Slot<\/th>\n<td>Slot 2<\/td>\n<\/tr>\n<tr>\n<th>PXI Express Slots<\/th>\n<td>0<\/td>\n<\/tr>\n<tr>\n<th>PXI Express Hybrid Slots<\/th>\n<td>0<\/td>\n<\/tr>\n<tr>\n<th>Backplane Architecture<\/th>\n<td>32-bit conventional PCI-compatible PXI<\/td>\n<\/tr>\n<tr>\n<th>Maximum System Bandwidth<\/th>\n<td>132 MB\/s<\/td>\n<\/tr>\n<tr>\n<th>PXI Hardware Specification<\/th>\n<td>Revision 2.2 compliant<\/td>\n<\/tr>\n<tr>\n<th>Module Compatibility<\/th>\n<td>Compatible 3U PXI and CompactPCI modules<\/td>\n<\/tr>\n<tr>\n<th>Backplane V(I\/O)<\/th>\n<td>+5 V<\/td>\n<\/tr>\n<tr>\n<th>PXI Trigger Lines<\/th>\n<td>8 shared lines<\/td>\n<\/tr>\n<tr>\n<th>Star-Trigger Connections<\/th>\n<td>Dedicated equal-length paths from slot 2 to slots 3\u20136<\/td>\n<\/tr>\n<tr>\n<th>Local Bus<\/th>\n<td>13 lines between adjacent peripheral slots<\/td>\n<\/tr>\n<tr>\n<th>Local-Bus Signal Capability<\/th>\n<td>High-speed TTL or analog signals up to 42 V<\/td>\n<\/tr>\n<tr>\n<th>System Reference Clock<\/th>\n<td>10 MHz PXI_CLK10<\/td>\n<\/tr>\n<tr>\n<th>Maximum Clock Skew Between Slots<\/th>\n<td>Less than 250 ps<\/td>\n<\/tr>\n<tr>\n<th>External Reference Source<\/th>\n<td>Available through the PXI_CLK10_IN pin in slot 2<\/td>\n<\/tr>\n<tr>\n<th>External Clock Selection<\/th>\n<td>Manual backplane switch configuration<\/td>\n<\/tr>\n<tr>\n<th>Power-Supply Type<\/th>\n<td>Universal AC<\/td>\n<\/tr>\n<tr>\n<th>Power-Supply Rating<\/th>\n<td>300 W<\/td>\n<\/tr>\n<tr>\n<th>Nominal AC Input<\/th>\n<td>100\u2013240 VAC<\/td>\n<\/tr>\n<tr>\n<th>Operating AC Range<\/th>\n<td>90\u2013264 VAC<\/td>\n<\/tr>\n<tr>\n<th>Nominal Input Frequency<\/th>\n<td>50\/60 Hz<\/td>\n<\/tr>\n<tr>\n<th>Operating Frequency Range<\/th>\n<td>47\u201363 Hz<\/td>\n<\/tr>\n<tr>\n<th>Input Current Rating<\/th>\n<td>4\u20132 A<\/td>\n<\/tr>\n<tr>\n<th>AC Overcurrent Protection<\/th>\n<td>Internal 5 A fuse; no user-serviceable components<\/td>\n<\/tr>\n<tr>\n<th>Power-Supply Efficiency<\/th>\n<td>Greater than 65% at full load and normal input voltage<\/td>\n<\/tr>\n<tr>\n<th>+3.3 V DC Capacity<\/th>\n<td>12 A<\/td>\n<\/tr>\n<tr>\n<th>+5 V DC Capacity<\/th>\n<td>17 A<\/td>\n<\/tr>\n<tr>\n<th>+12 V DC Capacity<\/th>\n<td>2 A<\/td>\n<\/tr>\n<tr>\n<th>\u221212 V DC Capacity<\/th>\n<td>0.8 A<\/td>\n<\/tr>\n<tr>\n<th>Per-Slot Cooling Capacity<\/th>\n<td>25 W<\/td>\n<\/tr>\n<tr>\n<th>Module-Cooling Fan<\/th>\n<td>86 cfm<\/td>\n<\/tr>\n<tr>\n<th>Fan Modes<\/th>\n<td>AUTO and HIGH<\/td>\n<\/tr>\n<tr>\n<th>Sound Pressure in AUTO Mode<\/th>\n<td>40.7 dBA at 25\u00b0C ambient<\/td>\n<\/tr>\n<tr>\n<th>Sound Pressure in HIGH Mode<\/th>\n<td>49.4 dBA<\/td>\n<\/tr>\n<tr>\n<th>Sound Power in AUTO Mode<\/th>\n<td>51.8 dBA at 25\u00b0C ambient<\/td>\n<\/tr>\n<tr>\n<th>Sound Power in HIGH Mode<\/th>\n<td>57.5 dBA<\/td>\n<\/tr>\n<tr>\n<th>Operating Temperature<\/th>\n<td>0\u00b0C to 50\u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Storage Temperature<\/th>\n<td>\u221220\u00b0C to 70\u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Operating Humidity<\/th>\n<td>10% to 90%, noncondensing<\/td>\n<\/tr>\n<tr>\n<th>Storage Humidity<\/th>\n<td>5% to 95%, noncondensing<\/td>\n<\/tr>\n<tr>\n<th>Maximum Altitude<\/th>\n<td>2,000 m<\/td>\n<\/tr>\n<tr>\n<th>Operational Shock<\/th>\n<td>30 g peak, half-sine, 11 ms pulse<\/td>\n<\/tr>\n<tr>\n<th>Operational Random Vibration<\/th>\n<td>5\u2013500 Hz, 0.3 grms<\/td>\n<\/tr>\n<tr>\n<th>Nonoperational Random Vibration<\/th>\n<td>5\u2013500 Hz, 2.4 grms<\/td>\n<\/tr>\n<tr>\n<th>Dimensions Without Feet<\/th>\n<td>177 \u00d7 257.1 \u00d7 212.8 mm<\/td>\n<\/tr>\n<tr>\n<th>Weight<\/th>\n<td>5 kg<\/td>\n<\/tr>\n<tr>\n<th>Installation Environment<\/th>\n<td>Indoor use<\/td>\n<\/tr>\n<tr>\n<th>Mounting Options<\/th>\n<td>Bench-top, portable or 19-inch rack mounting<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>PXI-1036 Part Number and Accessories<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Item<\/th>\n<th>Part Number<\/th>\n<th>\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435<\/th>\n<\/tr>\n<tr>\n<td>\u041f\u0425\u0418-1036<\/td>\n<td>779382-01<\/td>\n<td>Six-slot conventional PXI chassis with 300 W universal AC power supply<\/td>\n<\/tr>\n<tr>\n<td>PXI-1036DC<\/td>\n<td>779383-01<\/td>\n<td>Related six-slot chassis with combined AC and DC input capability<\/td>\n<\/tr>\n<tr>\n<td>PXI-103x Rack-Mount Kit<\/td>\n<td>778948-01<\/td>\n<td>Hardware for mounting a compatible PXI-103x chassis in a 19-inch rack<\/td>\n<\/tr>\n<tr>\n<td>PXI Filler-Panel Kit<\/td>\n<td>778933-01<\/td>\n<td>Filler panels for covering unused chassis slots<\/td>\n<\/tr>\n<tr>\n<td>PXI-103x Side-Handle and Rubber-Feet Kit<\/td>\n<td>778949-01<\/td>\n<td>Adds a carrying handle and bench-top rubber feet<\/td>\n<\/tr>\n<tr>\n<td>PXI Chassis Slot-Blocker Kit<\/td>\n<td>778678-01<\/td>\n<td>Two single-slot blockers for improving cooling performance<\/td>\n<\/tr>\n<tr>\n<td>US and Japanese AC Power Cord<\/td>\n<td>763000-01<\/td>\n<td>AC power cord for 120 V US or 100 V Japanese applications<\/td>\n<\/tr>\n<tr>\n<td>United Kingdom AC Power Cord<\/td>\n<td>763064-01<\/td>\n<td>BS 1363-compatible AC power cable<\/td>\n<\/tr>\n<tr>\n<td>Swiss AC Power Cord<\/td>\n<td>763065-01<\/td>\n<td>AC power cable for Swiss power outlets<\/td>\n<\/tr>\n<tr>\n<td>Australian AC Power Cord<\/td>\n<td>763066-01<\/td>\n<td>AC power cable for Australian power outlets<\/td>\n<\/tr>\n<tr>\n<td>Universal European AC Power Cord<\/td>\n<td>763067-01<\/td>\n<td>AC power cable for compatible European outlets<\/td>\n<\/tr>\n<tr>\n<td>North American 240 V Power Cord<\/td>\n<td>763068-01<\/td>\n<td>NEMA 6-15 power cable for supported 240 V installations<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The standard PXI-1036 chassis is identified by NI part number <strong>779382-01<\/strong>. The closely related PXI-1036DC uses part number 779383-01 and adds a DC input; it should be treated as a separate model when sourcing replacement hardware.<\/p>\n<p>Every PXI-1036 was originally supplied with three single-slot filler panels and one double filler panel. Confirm the included accessories when purchasing a pre-owned or refurbished chassis.<\/p>\n<h3>PXI-103x Rack-Mount Kit<\/h3>\n<p>The 778948-01 rack-mount kit supports installation of the PXI-1036 in a standard 19-inch equipment rack. Its compact chassis width leaves room for other equipment or cable-routing hardware when installed in a suitable rack layout.<\/p>\n<p>Maintain adequate ventilation above, behind and around both sides of the chassis. Rack hardware must not obstruct the bottom cooling-air intake.<\/p>\n<h3>Handle and Rubber-Feet Kit<\/h3>\n<p>The optional 778949-01 kit adds a side carrying handle and rubber feet for portable or bench-top operation. This configuration is useful for laboratory teams that move the chassis between development stations.<\/p>\n<p>The chassis weighs approximately 5 kg before installing the controller, modules and cables. Consider the complete configured weight when selecting a carrying case or transport method.<\/p>\n<h3>Filler Panels and Slot Blockers<\/h3>\n<p>Filler panels cover unused module openings and help maintain electromagnetic compatibility and controlled airflow. All unused positions should remain covered during normal operation.<\/p>\n<p>The 778678-01 slot-blocker kit contains two single-slot blockers. Slot blockers reduce air bypass through empty positions and redirect cooling airflow toward populated slots.<\/p>\n<h3>Regional Power-Cord Options<\/h3>\n<p>The universal AC supply supports multiple regional power standards, but the physical power cable must match the destination outlet and regulatory requirements.<\/p>\n<p>Confirm the required connector before ordering. A used chassis may be supplied without an AC cable or may include a cable intended for a different country.<\/p>\n<h3>300 W Universal AC Power Supply<\/h3>\n<p>The PXI-1036 incorporates a 300 W universal AC supply with automatic voltage and frequency ranging. It accepts nominal input from 100 VAC to 240 VAC and operates across a wider 90\u2013264 VAC range.<\/p>\n<p>The power supply provides +3.3 V, +5 V, +12 V and \u221212 V rails to the backplane. Power budgeting must evaluate each rail individually because remaining within the total wattage does not guarantee that every rail remains below its current limit.<\/p>\n<h3>Five Peripheral Slots<\/h3>\n<p>The chassis provides five peripheral positions instead of the three available in the related PXI-1031 architecture. It achieves this increased module capacity by limiting the embedded controller to a maximum width of two slots.<\/p>\n<p>This configuration is particularly efficient for remote control, where a single-slot interface leaves all five peripheral positions available for instruments.<\/p>\n<h3>Star-Trigger Slot<\/h3>\n<p>Slot 2 provides dedicated equal-length trigger lines to peripheral slots 3 through 6. A compatible timing module installed in this position can coordinate measurement and stimulus operations across the chassis.<\/p>\n<p>If dedicated star triggering is not required, slot 2 can accept an ordinary compatible PXI peripheral module.<\/p>\n<h3>PXI \u0422\u0440\u0438\u0433\u0433\u0435\u0440\u043d\u0430\u044f \u0448\u0438\u043d\u0430<\/h3>\n<p>All chassis slots share eight PXI trigger lines. Instruments can use these lines for start, stop, reference and event signals without requiring separate external cables for every connection.<\/p>\n<p>Trigger lines can be reserved through NI Measurement &amp; Automation Explorer. Reservation helps prevent software or multiple modules from attempting to drive the same trigger resource simultaneously.<\/p>\n<h3>PXI Local Bus<\/h3>\n<p>The 13-line local bus connects adjacent peripheral positions. Compatible devices can use this connection for high-speed TTL communication or analog signals as high as 42 V.<\/p>\n<p>Local-bus functions depend on the installed modules. Verify electrical compatibility and pin assignments before relying on local-bus connections between adjacent instruments.<\/p>\n<h3>10 MHz System Reference Clock<\/h3>\n<p>The PXI-1036 distributes an independently buffered 10 MHz PXI_CLK10 reference signal to every peripheral slot. Slot-to-slot clock skew is less than 250 ps.<\/p>\n<p>A compatible timing device in slot 2 can provide an external PXI_CLK10 source through the backplane. Unlike larger chassis such as the PXI-1042, the PXI-1036 does not provide rear-panel REF IN and REF OUT BNC connectors.<\/p>\n<p>Routing an external slot 2 clock requires manual configuration of switch S1 on the chassis backplane. Changing this switch requires powering down the chassis and following the documented service procedure.<\/p>\n<h3>Low-Noise Cooling<\/h3>\n<p>The PXI-1036 provides 25 W of cooling capacity per slot through an 86 cfm fan. The rear selector offers AUTO and HIGH operating modes.<\/p>\n<p>AUTO mode adjusts the fan speed according to the intake-air temperature and produces sound pressure as low as 40.7 dBA at 25\u00b0C ambient. HIGH mode maximizes airflow and produces a specified sound-pressure level of 49.4 dBA.<\/p>\n<p>HIGH mode is recommended when the chassis contains high-power instruments or operates near the upper ambient-temperature limit.<\/p>\n<h2>PXI-1036 Applications<\/h2>\n<ul>\n<li>Remote-controlled PXI test systems<\/li>\n<li>Portable data acquisition systems<\/li>\n<li>Compact automated test equipment<\/li>\n<li>Real-time measurement and control<\/li>\n<li>Electronic device validation<\/li>\n<li>Production functional testing<\/li>\n<li>Laboratory instrument automation<\/li>\n<li>Signal switching and routing<\/li>\n<li>Automotive electronic testing<\/li>\n<li>Aerospace and defense test systems<\/li>\n<li>Environmental monitoring<\/li>\n<li>Communication-interface testing<\/li>\n<li>Educational and university laboratories<\/li>\n<li>Field-service measurement systems<\/li>\n<li>Maintenance of conventional PXI platforms<\/li>\n<\/ul>\n<h3>Remote-Controlled PXI Systems<\/h3>\n<p>The PXI-1036 is well suited to systems controlled by an external desktop or industrial computer. A compatible MXI remote interface can extend the computer\u2019s PCI or PCI Express connection to the PXI chassis.<\/p>\n<p>Remote control allows users to select a host computer with the required processor, memory, storage and display capabilities without installing those resources inside the chassis.<\/p>\n<h3>Compact Data Acquisition<\/h3>\n<p>The five peripheral slots can accommodate multiple analog input, digital I\/O, counter, communication and signal-conditioning modules. This makes the chassis suitable for mixed-signal acquisition without the footprint of a full-width 18-slot system.<\/p>\n<p>The total acquisition rate must remain within the practical capabilities of the 132 MB\/s shared PCI backplane and the selected remote or embedded controller.<\/p>\n<h3>Portable Test Systems<\/h3>\n<p>With a 5 kg chassis weight, optional carrying handle and compact dimensions, the PXI-1036 can form the foundation of a portable engineering or service system.<\/p>\n<p>Installed modules, cables and fixtures increase total system weight. A protective transit case is recommended when the configured chassis will be transported frequently.<\/p>\n<h3>Real-Time Control<\/h3>\n<p>A compatible two-slot real-time PXI controller can create a compact standalone measurement and control system. This architecture can execute deterministic test and control applications without relying on a separate desktop computer.<\/p>\n<p>The selected controller and real-time software must support the installed modules and required drivers.<\/p>\n<h3>Automated Functional Testing<\/h3>\n<p>The chassis can combine a digital multimeter, DAQ device, waveform generator, switch and communication interface for electronic functional testing. Software can apply stimulus, route connections, collect measurements and evaluate results automatically.<\/p>\n<p>This architecture is useful for PCB validation, electronic assembly testing, sensor evaluation and production quality control.<\/p>\n<h3>Laboratory and Educational Systems<\/h3>\n<p>The 40.7 dBA AUTO-mode sound-pressure specification makes the PXI-1036 suitable for laboratories and teaching environments where excessive fan noise can be distracting.<\/p>\n<p>AUTO mode should be used only when sufficient thermal margin remains for the installed instruments. High-power configurations should use HIGH fan mode.<\/p>\n<h3>Legacy Test-System Sustainment<\/h3>\n<p>The PXI-1036 remains useful when an established test station depends on conventional PXI instruments, legacy software or an existing remote-control architecture.<\/p>\n<p>Replacing a failed chassis with the same model can reduce software, fixture and system-validation changes compared with migrating immediately to PXI Express.<\/p>\n<h2>PXI-1036 Installation Workflow<\/h2>\n<h4>Step 1: Confirm the Chassis Model<\/h4>\n<p>Verify that the unit is a PXI-1036 with part number 779382-01. Do not assume that PXI-1036 and PXI-1036DC power and rear-panel requirements are identical.<\/p>\n<h4>Step 2: Inspect the Chassis<\/h4>\n<p>Check the enclosure, backplane connectors, power inlet, fan openings and module guides for visible damage or contamination. Confirm that required filler panels and mounting hardware are present.<\/p>\n<h4>Step 3: Select Bench or Rack Installation<\/h4>\n<p>Use the optional handle and feet for portable bench-top operation or install the chassis using the compatible PXI-103x rack-mount kit.<\/p>\n<h4>Step 4: Provide Ventilation Clearance<\/h4>\n<p>Maintain at least 44.5 mm of clearance above, behind and along both sides of the chassis. Keep the bottom air intake unobstructed.<\/p>\n<h4>Step 5: Establish Protective Grounding<\/h4>\n<p>Connect the chassis to a properly grounded AC outlet. Use the rear chassis-ground screw when required by the facility installation or applicable safety procedure.<\/p>\n<h4>Step 6: Calculate Power Requirements<\/h4>\n<p>Add the controller and module current requirements separately for the +3.3 V, +5 V, +12 V and \u221212 V rails. Confirm that the configuration remains within every rail limit and the available cooling capacity.<\/p>\n<h4>Step 7: Select the Controller Architecture<\/h4>\n<p>Choose a compatible single-slot remote-control interface or a one- or two-slot PXI embedded controller. Controllers wider than two slots are not compatible with the chassis layout.<\/p>\n<h4>Step 8: Install the Controller<\/h4>\n<p>Place the chassis power switch in standby. Install the controller in slot 1 using the red system-slot guides, engage the injector\/ejector handle and secure its front-panel screws.<\/p>\n<h4>Step 9: Install Peripheral Modules<\/h4>\n<p>Install compatible conventional PXI or CompactPCI modules in slots 2 through 6. Use slot 2 for a timing module when star-trigger or external PXI_CLK10 functionality is required.<\/p>\n<h4>Step 10: Install Filler Panels<\/h4>\n<p>Cover all unused slots with the supplied filler panels. Add slot blockers when additional airflow control is required.<\/p>\n<h4>Step 11: Select the Fan Mode<\/h4>\n<p>Select HIGH for maximum cooling performance. Select AUTO for reduced acoustic noise only after confirming that the installed modules have adequate thermal margin.<\/p>\n<h4>Step 12: Connect the AC Supply<\/h4>\n<p>Use the correct regional grounded power cable. Apply AC power only after the controller and modules are secured and the ventilation openings are unobstructed.<\/p>\n<h4>Step 13: Configure the System in NI MAX<\/h4>\n<p>Start the host or embedded controller and open NI Measurement &amp; Automation Explorer. Identify the PXI controller, PXI-1036 chassis and installed instruments if they do not appear automatically.<\/p>\n<h4>Step 14: Configure Trigger Resources<\/h4>\n<p>Reserve any PXI trigger lines required by the application. This prevents other software or modules from dynamically using the same trigger path.<\/p>\n<h4>Step 15: Validate the System<\/h4>\n<p>Run instrument self-tests and a known measurement sequence. Confirm communication, trigger operation, clock configuration, data throughput and thermal performance under the expected maximum workload.<\/p>\n<h3>Controller Compatibility Considerations<\/h3>\n<p>The PXI-1036 accepts only one- or two-slot-wide embedded controllers. A three- or four-slot controller may physically conflict with the chassis enclosure and should not be forced into the system.<\/p>\n<p>For remote operation, verify the host interface, PXI remote-control module, cable, driver and operating-system compatibility as a complete set.<\/p>\n<h3>External Clock Configuration<\/h3>\n<p>An external 10 MHz clock can be supplied through the designated slot 2 PXI_CLK10_IN connection. The internal backplane switch must be configured for the required clock source.<\/p>\n<p>Only qualified personnel should access the chassis backplane. Disconnect AC power and follow electrostatic-discharge precautions before changing internal switch settings.<\/p>\n<h2>PXI-1036 Troubleshooting<\/h2>\n<h4>The PXI-1036 Does Not Power On<\/h4>\n<p>Confirm that the AC cable is properly connected and that the source voltage falls within the 90\u2013264 VAC operating range. Check the front standby switch and verify protective grounding.<\/p>\n<p>The internal AC fuse is not user-serviceable. If the chassis remains unpowered, qualified service or power-supply replacement may be required.<\/p>\n<h4>The Embedded Controller Does Not Boot<\/h4>\n<p>Verify that the controller is installed in system slot 1 and is fully seated. Confirm that it is a conventional PXI controller no more than two slots wide.<\/p>\n<p>Check memory, storage, display connections and the controller\u2019s own status indicators according to its user documentation.<\/p>\n<h4>The Remote Controller Is Not Detected<\/h4>\n<p>Inspect the host interface, MXI cable and PXI remote-control module. Verify that the host-side and chassis-side interfaces belong to a compatible family.<\/p>\n<p>Power sequencing can affect PCI enumeration. Follow the controller documentation for the correct order in which to power the PXI chassis and host computer.<\/p>\n<h4>A Peripheral Module Is Missing in NI MAX<\/h4>\n<p>Power down the chassis and reseat the module. Confirm conventional PXI compatibility, 5 V V(I\/O) support and correct driver installation.<\/p>\n<p>If multiple devices are missing, inspect the controller connection and chassis backplane rather than assuming that every peripheral module has failed.<\/p>\n<h4>A PXIe Module Does Not Fit<\/h4>\n<p>The PXI-1036 does not contain PXI Express or hybrid slots. PXIe-only modules require a compatible PXI Express chassis.<\/p>\n<h4>The Chassis Runs Too Hot<\/h4>\n<p>Set the fan selector to HIGH and ensure that the bottom intake and upper exhaust openings are clear. Maintain at least 44.5 mm of ventilation space around the chassis.<\/p>\n<p>Install filler panels and slot blockers, reduce the module load if necessary and confirm that no device exceeds the 25 W per-slot cooling capacity.<\/p>\n<h4>The Fan Is Too Loud<\/h4>\n<p>AUTO mode reduces fan speed according to intake temperature and can lower operator-position sound pressure to approximately 40.7 dBA at 25\u00b0C ambient.<\/p>\n<p>Do not use AUTO solely to mask a thermal problem. Clean airflow paths and verify module temperatures before reducing fan speed.<\/p>\n<h4>The PXI Trigger Does Not Work<\/h4>\n<p>Confirm that the source and destination instruments support the selected trigger line. Reserve the line in NI MAX and ensure that multiple modules are not configured to drive it simultaneously.<\/p>\n<h4>The Star Trigger Does Not Reach Other Modules<\/h4>\n<p>Verify that the timing module is installed in slot 2. Dedicated star-trigger connections extend from slot 2 to slots 3, 4, 5 and 6.<\/p>\n<h4>The External Reference Clock Is Not Used<\/h4>\n<p>The PXI-1036 does not have rear-panel reference-clock BNC connectors. An external PXI_CLK10 source must enter through slot 2, and backplane switch S1 must be configured accordingly.<\/p>\n<h4>Data Transfer Is Slower Than Expected<\/h4>\n<p>The 132 MB\/s value represents maximum conventional PCI system bandwidth. Actual sustained performance depends on controller speed, DMA transfers, remote-link bandwidth, bus sharing and software overhead.<\/p>\n<p>For example, the chassis backplane may support 132 MB\/s while an older remote-control interface provides a lower sustained transfer rate.<\/p>\n<h4>The System Becomes Unstable with Several Modules<\/h4>\n<p>Check the power demand on each backplane voltage rail. The combined module wattage may appear acceptable while one individual rail exceeds its current capacity.<\/p>\n<p>Also verify cooling, controller resources, driver compatibility and the number of PCI devices supported by the operating system.<\/p>\n<h4>The Chassis Is Not Identified Correctly in NI MAX<\/h4>\n<p>Open the PXI System entry in NI MAX, right-click the unidentified chassis and select PXI-1036 from the appropriate identification menu. Confirm that PXI Platform Services is installed.<\/p>\n<h3>Preventive Maintenance<\/h3>\n<p>Periodically inspect the cooling fan, intake openings, filler panels and power cable. Dust buildup can restrict airflow and increase module temperature even when the fan appears to operate normally.<\/p>\n<p>Disconnect AC power before cleaning the chassis. Internal service should be performed only by qualified personnel using appropriate electrostatic-discharge precautions.<\/p>\n<h2>PXI-1036 Comparison<\/h2>\n<table>\n<tbody>\n<tr>\n<th>\u041c\u043e\u0434\u0435\u043b\u044c<\/th>\n<th>Platform and Slots<\/th>\n<th>Power Configuration<\/th>\n<th>Best Suited For<\/th>\n<\/tr>\n<tr>\n<td>\u041f\u0425\u0418-1036<\/td>\n<td>6-slot PXI; 5 peripheral slots<\/td>\n<td>300 W universal AC<\/td>\n<td>Compact remote or two-slot embedded-controller systems<\/td>\n<\/tr>\n<tr>\n<td><a href=\"https:\/\/pxisource.com\/ru\/product\/pxi-1036dc\/\">PXI-1036DC<\/a><\/td>\n<td>6-slot PXI; 5 peripheral slots<\/td>\n<td>AC plus DC input<\/td>\n<td>Portable systems that must operate from DC power<\/td>\n<\/tr>\n<tr>\n<td><a href=\"https:\/\/pxisource.com\/ru\/product\/pxi-1031\/\">PXI-1031<\/a><\/td>\n<td>4-slot compact PXI chassis<\/td>\n<td>Universal AC<\/td>\n<td>Systems using fewer modules or wider embedded controllers<\/td>\n<\/tr>\n<tr>\n<td><a href=\"https:\/\/pxisource.com\/ru\/product\/pxi-1042\/\">PXI-1042<\/a><\/td>\n<td>8-slot PXI; 7 peripheral slots<\/td>\n<td>Universal AC<\/td>\n<td>Conventional PXI systems requiring more module capacity<\/td>\n<\/tr>\n<tr>\n<td><a href=\"https:\/\/pxisource.com\/ru\/product\/pxie-1073\/\">PXIe-1073<\/a><\/td>\n<td>PXI Express \u0448\u0430\u0441\u0441\u0438 \u0441 5 \u0441\u043b\u043e\u0442\u0430\u043c\u0438<\/td>\n<td>Universal AC with integrated remote control<\/td>\n<td>Compact PXI Express remote-control applications<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>PXI-1036 vs PXI-1036DC<\/h3>\n<p>Both models provide six physical slots, five peripheral positions, conventional PXI connectivity and 25 W per-slot cooling. The primary difference is the power architecture.<\/p>\n<p>The PXI-1036 operates from universal AC only. The PXI-1036DC adds a DC input for portable or vehicle-powered systems while retaining an AC input.<\/p>\n<p>Choose the PXI-1036 when AC power is always available. Choose the PXI-1036DC when the same test system must operate from both facility AC power and a suitable external DC source.<\/p>\n<h3>PXI-1036 vs PXI-1031<\/h3>\n<p>The PXI-1036 and PXI-1031 use a similarly sized enclosure. The PXI-1036 provides five peripheral slots by limiting the embedded controller to one or two slots.<\/p>\n<p>The PXI-1031 provides fewer peripheral positions but can support certain wider controller configurations. The correct model therefore depends on controller width and required instrument count.<\/p>\n<h3>PXI-1036 vs PXI-1042<\/h3>\n<p>The PXI-1036 provides five peripheral slots in a compact 5 kg enclosure. The PXI-1042 provides seven peripheral positions, a wider chassis and external reference-clock BNC connectors.<\/p>\n<p>Choose the PXI-1036 for portability, compact remote control or limited rack space. Choose the PXI-1042 when additional module capacity and rear external clock connections are required.<\/p>\n<h3>PXI-1036 vs PXIe-1073<\/h3>\n<p>The PXI-1036 is a conventional PCI-based PXI chassis that requires a separate remote-control or embedded-controller module. The PXIe-1073 is a PXI Express chassis with an integrated remote-control interface.<\/p>\n<p>The PXIe-1073 supports compatible PXI Express instrumentation and higher-bandwidth communication. The PXI-1036 remains appropriate for established systems using conventional PXI modules.<\/p>\n<h3>Selecting the Right Compact PXI Chassis<\/h3>\n<p>Select the PXI-1036 when the system requires five conventional PXI peripheral positions, universal AC input, a remote-control interface or a controller no wider than two slots.<\/p>\n<p>Select the PXI-1036DC when DC operation is required. Choose the PXI-1042 for more conventional PXI slots or a PXI Express chassis when the application requires PXIe instruments and higher data throughput.<\/p>\n<h3>Recommended Related Products<\/h3>\n<ul>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxi-1036dc\/\">PXI-1036DC AC\/DC-Powered PXI Chassis<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxi-1031\/\">PXI-1031 Compact PXI Chassis<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxi-1042\/\">PXI-1042 8-Slot PXI Chassis<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxi-1042q\/\">PXI-1042Q Low-Noise PXI Chassis<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxie-1073\/\">PXIe-1073 Integrated Remote-Control Chassis<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxi-8360\/\">PXI-8360 MXI-Express Remote-Control Module<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product-category\/%d0%bd%d0%b8\/pxi-%d1%81%d0%b8%d1%81%d1%82%d0%b5%d0%bc%d1%81\/pxi-chassis\/\">View More NI PXI and PXI Express Chassis<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product-category\/%d0%bd%d0%b8\/pxi-%d1%81%d0%b8%d1%81%d1%82%d0%b5%d0%bc%d1%81\/%d0%bc%d0%be%d0%b4%d1%83%d0%bb%d0%b8-pxi\/\">View NI PXI and PXI Express Modules<\/a><\/li>\n<\/ul>\n<h3>Why Choose the PXI-1036?<\/h3>\n<ul>\n<li>Provides five peripheral slots in a compact enclosure<\/li>\n<li>Supports compatible PXI remote-control interfaces<\/li>\n<li>Accepts one- or two-slot embedded controllers<\/li>\n<li>Offers 132 MB\/s conventional PXI bandwidth<\/li>\n<li>Includes a 300 W universal AC power supply<\/li>\n<li>Provides 25 W cooling capacity per slot<\/li>\n<li>Operates at only 40.7 dBA in AUTO mode<\/li>\n<li>Supports compatible PXI and CompactPCI modules<\/li>\n<li>Includes PXI trigger, star-trigger and local-bus resources<\/li>\n<li>Distributes a low-skew 10 MHz system reference<\/li>\n<li>Supports optional bench-top and rack-mount accessories<\/li>\n<li>Provides a 30 g operational shock rating<\/li>\n<li>Helps maintain compact legacy PXI test systems<\/li>\n<\/ul>\n<h2>Frequently Asked Questions<\/h2>\n<h4>What is the PXI-1036?<\/h4>\n<p>The PXI-1036 is a compact six-slot conventional PXI chassis designed for remote-control, real-time, data acquisition and automated test applications.<\/p>\n<h4>What is the PXI-1036 part number?<\/h4>\n<p>The standard PXI-1036 universal AC chassis uses NI part number <strong>779382-01<\/strong>.<\/p>\n<h4>How many peripheral slots does it provide?<\/h4>\n<p>The PXI-1036 provides five peripheral slots in addition to the system-controller slot.<\/p>\n<h4>What controller can be installed?<\/h4>\n<p>The chassis accepts a compatible remote-control interface or a conventional embedded PXI controller that occupies no more than two slots.<\/p>\n<h4>Is the PXI-1036 a PXI Express chassis?<\/h4>\n<p>No. It uses a 32-bit conventional PCI-based PXI backplane and provides no native PXI Express or hybrid slots.<\/p>\n<h4>Can PXIe modules be installed?<\/h4>\n<p>No. PXI Express-only modules require a compatible PXI Express chassis.<\/p>\n<h4>What is the maximum system bandwidth?<\/h4>\n<p>The maximum conventional PXI system bandwidth is 132 MB\/s. Actual sustained performance depends on the controller, remote link, installed modules and software.<\/p>\n<h4>What is the power-supply rating?<\/h4>\n<p>The PXI-1036 has a 300 W universal AC power supply.<\/p>\n<h4>What AC voltage does it support?<\/h4>\n<p>It accepts nominal 100\u2013240 VAC, with a specified operating range of 90\u2013264 VAC and 47\u201363 Hz.<\/p>\n<h4>Can the PXI-1036 operate from DC power?<\/h4>\n<p>No. The standard PXI-1036 is an AC-powered chassis. Select the PXI-1036DC when DC input capability is required.<\/p>\n<h4>What is the cooling capacity?<\/h4>\n<p>The chassis provides 25 W cooling capacity per slot through an 86 cfm module-cooling fan.<\/p>\n<h4>How loud is the PXI-1036?<\/h4>\n<p>Sound pressure is specified at 40.7 dBA in AUTO mode at 25\u00b0C ambient and 49.4 dBA in HIGH mode.<\/p>\n<h4>What is the operating-temperature range?<\/h4>\n<p>The PXI-1036 operates from 0\u00b0C to 50\u00b0C.<\/p>\n<h4>Does it provide star triggering?<\/h4>\n<p>Yes. Slot 2 provides dedicated equal-length star-trigger connections to slots 3 through 6.<\/p>\n<h4>Does the PXI-1036 have external reference-clock BNC connectors?<\/h4>\n<p>No. An external PXI_CLK10 reference must be supplied through the designated slot 2 backplane connection.<\/p>\n<h4>Can the PXI-1036 be rack mounted?<\/h4>\n<p>Yes. The 778948-01 PXI-103x rack-mount kit supports installation in a compatible 19-inch equipment rack.<\/p>\n<h4>Can it be used as a portable chassis?<\/h4>\n<p>Yes. The compact 5 kg enclosure and optional 778949-01 side-handle and rubber-feet kit make it suitable for portable laboratory systems.<\/p>\n<h4>What is the difference between PXI-1036 and PXI-1036DC?<\/h4>\n<p>The PXI-1036 uses universal AC power. The PXI-1036DC adds a DC input for applications that must operate away from conventional AC mains.<\/p>\n<h4>Is the PXI-1036 suitable for high-speed streaming?<\/h4>\n<p>It supports many conventional PXI applications, but its shared 132 MB\/s PCI bandwidth is lower than the multi-gigabyte-per-second throughput available from PXI Express chassis.<\/p>\n<h3>Request a Quote for the PXI-1036<\/h3>\n<p>Contact us for current availability, condition, lead time and project pricing for the <strong>NI PXI-1036 6-Slot Universal AC PXI Chassis<\/strong>. We can also help verify controller compatibility, rack-mount accessories, power cables and conventional PXI modules for your test system.<\/p>","protected":false},"excerpt":{"rendered":"<p>PXI-1036 6-Slot Universal AC PXI Chassis The NI PXI-1036 is a compact six-slot, 3U PXI chassis developed for remote-control, real-time,<\/p>","protected":false},"featured_media":31175,"template":"","meta":{"_acf_changed":false},"product_brand":[18],"product_cat":[19],"product_tag":[],"class_list":["post-29972","product","type-product","status-publish","has-post-thumbnail","product_brand-national-instruments","product_cat-pxi-chassis","first","instock","shipping-taxable","product-type-simple"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.0 (Yoast SEO v28.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>NI PXI-1036 PXI Chassis 779382-01, In Stock | Project Pricing<\/title>\n<meta name=\"description\" content=\"The NI PXI-1036 is a compact 6-slot PXI chassis with five peripheral slots, 132 MB\/s bandwidth, a 300 W AC supply and low-noise cooling.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/pxisource.com\/ru\/product\/pxi-1036\/\" \/>\n<meta property=\"og:locale\" content=\"ru_RU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"PXI-1036\" \/>\n<meta property=\"og:description\" content=\"The NI PXI-1036 is a compact 6-slot PXI chassis with five peripheral slots, 132 MB\/s bandwidth, a 300 W AC supply and low-noise cooling.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/pxisource.com\/ru\/product\/pxi-1036\/\" \/>\n<meta property=\"og:site_name\" content=\"PXI Source\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=61582573040385\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-11T04:49:03+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PXI-1036.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"800\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u0426\u0435\u043d\u0430\" \/>\n\t<meta name=\"twitter:data1\" content=\"\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c\" \/>\n\t<meta name=\"twitter:data2\" content=\"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxi-1036\\\/\",\"url\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxi-1036\\\/\",\"name\":\"NI PXI-1036 PXI Chassis 779382-01, In Stock | Project Pricing\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxi-1036\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxi-1036\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/PXI-1036.webp\",\"datePublished\":\"2025-09-23T06:17:07+00:00\",\"dateModified\":\"2026-09-11T04:49:03+00:00\",\"description\":\"The NI PXI-1036 is a compact 6-slot PXI chassis with five peripheral slots, 132 MB\\\/s bandwidth, a 300 W AC supply and low-noise cooling.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxi-1036\\\/#breadcrumb\"},\"inLanguage\":\"ru-RU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/pxisource.com\\\/product\\\/pxi-1036\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxi-1036\\\/#primaryimage\",\"url\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/PXI-1036.webp\",\"contentUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/PXI-1036.webp\",\"width\":800,\"height\":800,\"caption\":\"PXI-1036\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxi-1036\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/pxisource.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\\\/\\\/pxisource.com\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"PXI-1036\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\",\"url\":\"https:\\\/\\\/pxisource.com\\\/\",\"name\":\"PXI Systems\",\"description\":\"NI PXI, PXIe Modular Test Instrument Supplier\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/pxisource.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ru-RU\"}]}<\/script>\n<meta property=\"product:brand\" content=\"National Instruments\" \/>\n<meta property=\"product:price:currency\" content=\"USD\" \/>\n<meta property=\"og:availability\" content=\"instock\" \/>\n<meta property=\"product:availability\" content=\"instock\" \/>\n<meta property=\"product:condition\" content=\"new\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"NI PXI-1036 PXI Chassis 779382-01, In Stock | Project Pricing","description":"The NI PXI-1036 is a compact 6-slot PXI chassis with five peripheral slots, 132 MB\/s bandwidth, a 300 W AC supply and low-noise cooling.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/pxisource.com\/ru\/product\/pxi-1036\/","og_locale":"ru_RU","og_type":"article","og_title":"PXI-1036","og_description":"The NI PXI-1036 is a compact 6-slot PXI chassis with five peripheral slots, 132 MB\/s bandwidth, a 300 W AC supply and low-noise cooling.","og_url":"https:\/\/pxisource.com\/ru\/product\/pxi-1036\/","og_site_name":"PXI Source","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=61582573040385","article_modified_time":"2026-09-11T04:49:03+00:00","og_image":[{"width":800,"height":800,"url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PXI-1036.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"\u0426\u0435\u043d\u0430":"","\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c":"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/pxisource.com\/product\/pxi-1036\/","url":"https:\/\/pxisource.com\/product\/pxi-1036\/","name":"NI PXI-1036 PXI Chassis 779382-01, In Stock | Project Pricing","isPartOf":{"@id":"https:\/\/pxisource.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/pxisource.com\/product\/pxi-1036\/#primaryimage"},"image":{"@id":"https:\/\/pxisource.com\/product\/pxi-1036\/#primaryimage"},"thumbnailUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PXI-1036.webp","datePublished":"2025-09-23T06:17:07+00:00","dateModified":"2026-09-11T04:49:03+00:00","description":"The NI PXI-1036 is a compact 6-slot PXI chassis with five peripheral slots, 132 MB\/s bandwidth, a 300 W AC supply and low-noise cooling.","breadcrumb":{"@id":"https:\/\/pxisource.com\/product\/pxi-1036\/#breadcrumb"},"inLanguage":"ru-RU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/pxisource.com\/product\/pxi-1036\/"]}]},{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/pxisource.com\/product\/pxi-1036\/#primaryimage","url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PXI-1036.webp","contentUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PXI-1036.webp","width":800,"height":800,"caption":"PXI-1036"},{"@type":"BreadcrumbList","@id":"https:\/\/pxisource.com\/product\/pxi-1036\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/pxisource.com\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/pxisource.com\/shop\/"},{"@type":"ListItem","position":3,"name":"PXI-1036"}]},{"@type":"WebSite","@id":"https:\/\/pxisource.com\/#website","url":"https:\/\/pxisource.com\/","name":"\u0421\u0438\u0441\u0442\u0435\u043c\u044b PXI","description":"NI PXI, PXIe Modular Test Instrument Supplier","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/pxisource.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ru-RU"}]},"product_brand":"National Instruments","product_price_currency":"USD","og_availability":"instock","product_availability":"instock","product_condition":"new"},"_links":{"self":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/29972","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":7,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/29972\/revisions"}],"predecessor-version":[{"id":36594,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/29972\/revisions\/36594"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media\/31175"}],"wp:attachment":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media?parent=29972"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_brand?post=29972"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_cat?post=29972"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_tag?post=29972"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}