{"id":29458,"date":"2025-09-17T14:24:17","date_gmt":"2025-09-17T06:24:17","guid":{"rendered":"https:\/\/pxisource.com\/?post_type=product&#038;p=29458"},"modified":"2026-08-27T20:21:32","modified_gmt":"2026-08-27T12:21:32","slug":"ni-9252","status":"publish","type":"product","link":"https:\/\/pxisource.com\/ru\/product\/ni-9252\/","title":{"rendered":"NI-9252"},"content":{"rendered":"<h3>Product Introduction<\/h3>\n<p>\n\u0417\u0435\u043c\u043b\u044f <strong>NI-9252<\/strong> \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f <strong>8-channel C Series voltage input module<\/strong> designed for high-accuracy data acquisition, industrial measurement, automated test, research, control-system monitoring, and multi-channel voltage measurement applications.\n<\/p>\n<p>\nThe NI-9252 provides <strong>8 differential analog input channels<\/strong>, \u0430 <strong>\u00b110 V input range<\/strong>, <strong>24-bit resolution<\/strong>, and sampling rates up to <strong>50 kS\/s per channel<\/strong>.\n<\/p>\n<p>\nUnlike general-purpose multiplexed voltage modules, the NI-9252 is designed for synchronized multi-channel acquisition and includes programmable hardware filtering that can help reduce measurement noise before data reaches the host application.\n<\/p>\n<h3>Product Overview<\/h3>\n<p>\n\u0417\u0435\u043c\u043b\u044f <strong>National Instruments NI-9252<\/strong> belongs to the NI C Series family and can be installed in compatible <strong>\u041a\u043e\u043c\u043f\u0430\u043a\u0442\u043d\u044b\u0439 \u0426\u0410\u041f<\/strong> \u0438 <strong>CompactRIO<\/strong> chassis.\n<\/p>\n<p>\nA typical measurement architecture is:\n<\/p>\n<p>\n<strong>Voltage Signals \/ Conditioned Sensors \u2192 NI-9252 \u2192 CompactDAQ or CompactRIO \u2192 Host Software<\/strong>\n<\/p>\n<p>\nThe module is suitable for systems requiring multiple accurately synchronized voltage measurements with higher resolution than conventional 16-bit DAQ hardware.\n<\/p>\n<h3>Key Features<\/h3>\n<h4>8 Differential Analog Input Channels<\/h4>\n<p>\nThe NI-9252 provides <strong>8 differential analog input channels<\/strong>.\n<\/p>\n<p>\nDifferential input architecture is useful for applications where signals need improved rejection of common-mode electrical noise compared with simple single-ended measurement configurations.\n<\/p>\n<p>\n\u0422\u0438\u043f\u0438\u0447\u043d\u044b\u0435 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f \u0432\u043a\u043b\u044e\u0447\u0430\u044e\u0442:\n<\/p>\n<ul>\n<li>Voltage monitoring<\/li>\n<li>Electronic validation<\/li>\n<li>Industrial measurement<\/li>\n<li>Automated test<\/li>\n<li>Control-system monitoring<\/li>\n<li>Laboratory research<\/li>\n<li>Multi-channel data acquisition<\/li>\n<\/ul>\n<h4>\u00b110 V Input Range<\/h4>\n<p>\nEach NI-9252 analog input channel supports a nominal measurement range of <strong>-10 V to +10 V<\/strong>.\n<\/p>\n<p>\nThis voltage range makes the module suitable for many conditioned sensor outputs, industrial voltage signals, electronic test points, and general-purpose analog measurements.\n<\/p>\n<h4>24-Bit Resolution<\/h4>\n<p>\nThe NI-9252 provides <strong>24-bit analog input resolution<\/strong>.\n<\/p>\n<p>\nThe high-resolution architecture is useful for applications where relatively small signal changes must be measured accurately across a \u00b110 V input range.\n<\/p>\n<h4>50 kS\/s per Channel Sampling<\/h4>\n<p>\nThe NI-9252 supports sampling rates up to <strong>50 kS\/s per channel<\/strong>.\n<\/p>\n<p>\nBecause each channel can operate at this rate, the module is well suited for multi-channel measurement applications requiring synchronized acquisition of moderately fast signals.\n<\/p>\n<h4>Simultaneous Multi-Channel Acquisition<\/h4>\n<p>\nThe NI-9252 is designed for synchronized multi-channel acquisition across its eight voltage inputs.\n<\/p>\n<p>\nThis capability is important for measurements where timing relationships between channels matter.\n<\/p>\n<p>\nApplications can include:\n<\/p>\n<ul>\n<li>Multi-sensor testing<\/li>\n<li>Power and control-system measurements<\/li>\n<li>Phase-related voltage acquisition<\/li>\n<li>Transient monitoring<\/li>\n<li>Electronic system validation<\/li>\n<\/ul>\n<h4>Programmable Hardware Filters<\/h4>\n<p>\nOne of the distinctive features of the NI-9252 is its <strong>programmable hardware filtering<\/strong>.\n<\/p>\n<p>\nThe module provides selectable filtering options including:\n<\/p>\n<ul>\n<li>Butterworth filters<\/li>\n<li>Comb filters<\/li>\n<\/ul>\n<p>\nThese hardware filters can help reduce unwanted measurement noise before the acquired data is processed by the host application.\n<\/p>\n<h4>Butterworth Filtering<\/h4>\n<p>\nButterworth filtering can be useful when the application requires a relatively flat passband response while attenuating higher-frequency noise.\n<\/p>\n<p>\nThis can improve measurement quality in applications where broadband noise would otherwise reduce useful signal resolution.\n<\/p>\n<h4>Comb Filtering<\/h4>\n<p>\nComb filters can be useful for suppressing repetitive interference components associated with periodic electrical noise.\n<\/p>\n<p>\nThe correct filter configuration should be selected according to the signal bandwidth and noise characteristics of the measurement system.\n<\/p>\n<h4>CompactDAQ Compatibility<\/h4>\n<p>\nThe NI-9252 can be installed in compatible <strong>CompactDAQ chassis<\/strong> for PC-based data acquisition.\n<\/p>\n<p>\nA typical architecture is:\n<\/p>\n<p>\n<strong>Sensors \u2192 NI-9252 \u2192 CompactDAQ Chassis \u2192 USB \/ Ethernet \/ Other Host Interface \u2192 Computer<\/strong>\n<\/p>\n<p>\nThis configuration is useful for laboratory measurement, automated test, production test, and distributed data acquisition.\n<\/p>\n<h4>CompactRIO Compatibility<\/h4>\n<p>\nThe NI-9252 can also be used with compatible <strong>CompactRIO<\/strong> hardware.\n<\/p>\n<p>\nCompactRIO integration is useful for systems requiring:\n<\/p>\n<ul>\n<li>Embedded measurement<\/li>\n<li>Industrial monitoring<\/li>\n<li>Real-time control<\/li>\n<li>FPGA-based processing<\/li>\n<li>Distributed measurement<\/li>\n<li>Rugged test systems<\/li>\n<\/ul>\n<h3>Technical Specifications<\/h3>\n<table>\n<tr>\n<th>\u041f\u0430\u0440\u0430\u043c\u0435\u0442\u0440<\/th>\n<th>\u0421\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f<\/th>\n<\/tr>\n<tr>\n<td width=\"280\">Product Type<\/td>\n<td>C Series Voltage Input Module<\/td>\n<\/tr>\n<tr>\n<td>\u041c\u043e\u0434\u0435\u043b\u044c<\/td>\n<td>NI-9252<\/td>\n<\/tr>\n<tr>\n<td>Manufacturer<\/td>\n<td>\u041d\u0430\u0446\u0438\u043e\u043d\u0430\u043b\u044c\u043d\u044b\u0435 \u0438\u043d\u0441\u0442\u0440\u0443\u043c\u0435\u043d\u0442\u044b<\/td>\n<\/tr>\n<tr>\n<td>Supported Platform<\/td>\n<td>C Series \/ CompactDAQ \/ CompactRIO<\/td>\n<\/tr>\n<tr>\n<td>Analog Input Channels<\/td>\n<td>8 Differential<\/td>\n<\/tr>\n<tr>\n<td>Analog Input Range<\/td>\n<td>-10 V to +10 V<\/td>\n<\/tr>\n<tr>\n<td>Analog Input Resolution<\/td>\n<td>24 Bit<\/td>\n<\/tr>\n<tr>\n<td>Maximum Sample Rate<\/td>\n<td>50 kS\/s per Channel<\/td>\n<\/tr>\n<tr>\n<td>Multi-Channel Acquisition<\/td>\n<td>Simultaneous \/ Synchronized<\/td>\n<\/tr>\n<tr>\n<td>Programmable Hardware Filtering<\/td>\n<td>Supported<\/td>\n<\/tr>\n<tr>\n<td>Filter Types<\/td>\n<td>Butterworth and Comb<\/td>\n<\/tr>\n<tr>\n<td>Part Number &#8211; Screw Terminal<\/td>\n<td>786782-01<\/td>\n<\/tr>\n<tr>\n<td>Part Number &#8211; D-SUB<\/td>\n<td>786783-01<\/td>\n<\/tr>\n<tr>\n<td>Primary Applications<\/td>\n<td>Data Acquisition, Automated Test, Industrial Measurement, Research and Voltage Monitoring<\/td>\n<\/tr>\n<\/table>\n<h3>NI-9252 Part Numbers<\/h3>\n<p>\nThe NI-9252 is available in different front-connection configurations. The electrical measurement functionality is closely related, but the connector type differs.\n<\/p>\n<table>\n<tr>\n<th>Part Number<\/th>\n<th>Connection Type<\/th>\n<th>\u041a\u043e\u043d\u0444\u0438\u0433\u0443\u0440\u0430\u0446\u0438\u044f<\/th>\n<\/tr>\n<tr>\n<td><strong>786782-01<\/strong><\/td>\n<td>\u0412\u0438\u043d\u0442\u043e\u0432\u043e\u0439 \u0442\u0435\u0440\u043c\u0438\u043d\u0430\u043b<\/td>\n<td>NI-9252 with Screw Terminal Connection<\/td>\n<\/tr>\n<tr>\n<td><strong>786783-01<\/strong><\/td>\n<td>D-SUB<\/td>\n<td>NI-9252 with D-SUB Connection<\/td>\n<\/tr>\n<\/table>\n<p>\nWhen requesting a quotation or replacing an existing NI-9252, provide the complete part number to ensure the correct connector configuration.\n<\/p>\n<h3>Screw Terminal vs D-SUB NI-9252<\/h3>\n<table>\n<tr>\n<th>\u0424\u0443\u043d\u043a\u0446\u0438\u044f<\/th>\n<th>786782-01<\/th>\n<th>786783-01<\/th>\n<\/tr>\n<tr>\n<td>Module<\/td>\n<td>NI-9252<\/td>\n<td>NI-9252<\/td>\n<\/tr>\n<tr>\n<td>Analog Inputs<\/td>\n<td>8<\/td>\n<td>8<\/td>\n<\/tr>\n<tr>\n<td>\u0420\u0430\u0437\u0440\u0435\u0448\u0435\u043d\u0438\u0435<\/td>\n<td>24 Bit<\/td>\n<td>24 Bit<\/td>\n<\/tr>\n<tr>\n<td>Sample Rate<\/td>\n<td>50 kS\/s\/ch<\/td>\n<td>50 kS\/s\/ch<\/td>\n<\/tr>\n<tr>\n<td>Input Range<\/td>\n<td>\u00b110 V<\/td>\n<td>\u00b110 V<\/td>\n<\/tr>\n<tr>\n<td>Connection<\/td>\n<td><strong>\u0412\u0438\u043d\u0442\u043e\u0432\u043e\u0439 \u0442\u0435\u0440\u043c\u0438\u043d\u0430\u043b<\/strong><\/td>\n<td><strong>D-SUB<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Typical Advantage<\/td>\n<td>Convenient Field Wiring<\/td>\n<td>Harness \/ Cable Integration<\/td>\n<\/tr>\n<\/table>\n<h3>NI-9970 Screw Terminal Plug<\/h3>\n<p>\nNI lists the <strong>NI-9970 18-position screw terminal plug<\/strong> with the screw-terminal version of the NI-9252.\n<\/p>\n<p>\nThis accessory is associated with <strong>part number 786782-01<\/strong>.\n<\/p>\n<p>\nWhen purchasing a used or replacement NI-9252, verify whether the required removable terminal plug is included.\n<\/p>\n<h3>How Does the NI-9252 Work?<\/h3>\n<p>\nThe NI-9252 converts analog voltage signals into high-resolution digital measurement data.\n<\/p>\n<p>\nA simplified acquisition path is:\n<\/p>\n<p>\n<strong>Voltage Signal \u2192 NI-9252 Analog Input \u2192 ADC \u2192 Hardware Filter \u2192 C Series Chassis \u2192 Host Application<\/strong>\n<\/p>\n<p>\nThe acquired measurements can then be displayed, analyzed, logged, processed, or used as part of an automated control or test system.\n<\/p>\n<h3>What Is a C Series Voltage Input Module?<\/h3>\n<p>\nA <strong>C Series voltage input module<\/strong> provides analog measurement channels for compatible CompactDAQ and CompactRIO systems.\n<\/p>\n<p>\nC Series architecture allows engineers to combine different module types in one chassis, including:\n<\/p>\n<ul>\n<li>Voltage input modules<\/li>\n<li>Current input modules<\/li>\n<li>Temperature modules<\/li>\n<li>Strain and bridge modules<\/li>\n<li>Digital I\/O modules<\/li>\n<li>Relay modules<\/li>\n<li>Communication modules<\/li>\n<\/ul>\n<p>\nThis modular architecture makes it possible to customize the measurement system according to the application.\n<\/p>\n<h3>High-Resolution Voltage Measurement<\/h3>\n<p>\nThe 24-bit ADC architecture allows the NI-9252 to capture small voltage changes with high digital resolution.\n<\/p>\n<p>\nThis is useful for applications involving:\n<\/p>\n<ul>\n<li>Precision sensor measurements<\/li>\n<li>Low-level signal changes<\/li>\n<li>Electronic validation<\/li>\n<li>Long-duration monitoring<\/li>\n<li>Laboratory measurement<\/li>\n<\/ul>\n<p>\nActual system accuracy also depends on signal conditioning, noise, grounding, chassis configuration, wiring, calibration, and environmental conditions.\n<\/p>\n<h3>\u041c\u043d\u043e\u0433\u043e\u043a\u0430\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0441\u0431\u043e\u0440 \u0434\u0430\u043d\u043d\u044b\u0445<\/h3>\n<p>\nWith eight analog inputs, the NI-9252 can acquire several voltage signals in one module.\n<\/p>\n<p>\nA typical system could measure:\n<\/p>\n<p>\n<strong>CH0 \u2192 Sensor 1<\/strong><br \/>\n<strong>CH1 \u2192 Sensor 2<\/strong><br \/>\n<strong>CH2 \u2192 Voltage Test Point<\/strong><br \/>\n<strong>CH3 \u2192 Control Signal<\/strong><br \/>\n<strong>CH4\u2013CH7 \u2192 Additional Signals<\/strong>\n<\/p>\n<p>\nThis reduces the number of modules required in applications where multiple \u00b110 V signals need to be monitored.\n<\/p>\n<h3>Electronic Validation<\/h3>\n<p>\nThe NI-9252 is suitable for electronic validation systems requiring synchronized acquisition of multiple voltage signals.\n<\/p>\n<p>\nTypical measurements include:\n<\/p>\n<ul>\n<li>Power-supply rails<\/li>\n<li>Control voltages<\/li>\n<li>Sensor outputs<\/li>\n<li>Reference voltages<\/li>\n<li>Analog circuit outputs<\/li>\n<li>System response signals<\/li>\n<\/ul>\n<h3>Automated Test<\/h3>\n<p>\nThe NI-9252 can be incorporated into automated test systems using CompactDAQ or CompactRIO.\n<\/p>\n<p>\nA typical test sequence can:\n<\/p>\n<ol>\n<li>Configure the required NI-9252 channels.<\/li>\n<li>Set the acquisition rate.<\/li>\n<li>Select the appropriate hardware filter.<\/li>\n<li>Start synchronized acquisition.<\/li>\n<li>Apply stimulus to the DUT using other test hardware.<\/li>\n<li>Acquire the DUT voltage response.<\/li>\n<li>Analyze the measurements.<\/li>\n<li>Determine pass or fail status.<\/li>\n<\/ol>\n<h3>Industrial Monitoring<\/h3>\n<p>\nThe NI-9252 can monitor voltage outputs from compatible industrial sensors and control equipment.\n<\/p>\n<p>\n\u041e\u0431\u043b\u0430\u0441\u0442\u0438 \u043f\u0440\u0438\u043c\u0435\u043d\u0435\u043d\u0438\u044f \u0432\u043a\u043b\u044e\u0447\u0430\u044e\u0442:\n<\/p>\n<ul>\n<li>Machine monitoring<\/li>\n<li>Process monitoring<\/li>\n<li>Control-system validation<\/li>\n<li>\u0414\u0438\u0430\u0433\u043d\u043e\u0441\u0442\u0438\u043a\u0430 \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044f<\/li>\n<li>\u041c\u043e\u043d\u0438\u0442\u043e\u0440\u0438\u043d\u0433 \u0441\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u044f<\/li>\n<li>Industrial research<\/li>\n<\/ul>\n<h3>Sensor Measurement<\/h3>\n<p>\nThe NI-9252 directly measures voltage signals. Sensors producing a compatible voltage output can be connected directly when their electrical characteristics meet the module specifications.\n<\/p>\n<p>\nOther sensor types may require external signal conditioning.\n<\/p>\n<p>\nExamples include:\n<\/p>\n<ul>\n<li>Current-output sensors<\/li>\n<li>Bridge sensors<\/li>\n<li>\u0422\u0435\u0440\u043c\u043e\u043f\u0430\u0440\u044b<\/li>\n<li>\u0420\u0422\u0414<\/li>\n<li>IEPE sensors<\/li>\n<li>High-voltage sensors<\/li>\n<\/ul>\n<h3>Programmable Filtering<\/h3>\n<p>\nProgrammable filtering is one of the features that distinguishes the NI-9252 from simpler voltage input modules.\n<\/p>\n<p>\nA simplified signal chain is:\n<\/p>\n<p>\n<strong>Sensor Signal + Noise \u2192 NI-9252 Hardware Filter \u2192 Reduced Unwanted Frequency Content \u2192 Measurement Data<\/strong>\n<\/p>\n<p>\nThe appropriate filter should be selected according to the useful signal bandwidth and interference frequencies present in the system.\n<\/p>\n<h3>50 kS\/s\/ch vs Aggregate Sampling<\/h3>\n<p>\nThe NI-9252 specification is <strong>50 kS\/s per channel<\/strong>, not a single 50 kS\/s aggregate rate shared across all eight inputs.\n<\/p>\n<p>\nThis distinction is important when comparing the NI-9252 with conventional multiplexed multifunction DAQ hardware.\n<\/p>\n<table>\n<tr>\n<th>Architecture<\/th>\n<th>NI-9252<\/th>\n<th>Typical Multiplexed DAQ<\/th>\n<\/tr>\n<tr>\n<td>Specified Sampling<\/td>\n<td><strong>50 kS\/s\/ch<\/strong><\/td>\n<td>Often Aggregate<\/td>\n<\/tr>\n<tr>\n<td>Multi-Channel Timing<\/td>\n<td><strong>Synchronized<\/strong><\/td>\n<td>Sequential<\/td>\n<\/tr>\n<tr>\n<td>Channel-to-Channel Relationship<\/td>\n<td><strong>Preserved<\/strong><\/td>\n<td>Includes Multiplexing Delay<\/td>\n<\/tr>\n<\/table>\n<h3>NI-9252 vs NI-9239<\/h3>\n<p>\nThe NI-9252 and NI-9239 are both \u00b110 V, 24-bit C Series voltage input modules with 50 kS\/s\/ch acquisition capability, but the channel count is an important difference.\n<\/p>\n<table>\n<tr>\n<th>\u0424\u0443\u043d\u043a\u0446\u0438\u044f<\/th>\n<th>NI-9252<\/th>\n<th>NI-9239<\/th>\n<\/tr>\n<tr>\n<td>Input Range<\/td>\n<td>\u00b110 V<\/td>\n<td>\u00b110 V<\/td>\n<\/tr>\n<tr>\n<td>\u0420\u0430\u0437\u0440\u0435\u0448\u0435\u043d\u0438\u0435<\/td>\n<td>24 Bit<\/td>\n<td>24 Bit<\/td>\n<\/tr>\n<tr>\n<td>Sample Rate<\/td>\n<td>50 kS\/s\/ch<\/td>\n<td>50 kS\/s\/ch<\/td>\n<\/tr>\n<tr>\n<td>Analog Input Channels<\/td>\n<td><strong>8<\/strong><\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<td>Primary Advantage<\/td>\n<td><strong>Higher Channel Density<\/strong><\/td>\n<td>Lower Channel Count<\/td>\n<\/tr>\n<\/table>\n<h3>NI-9252 vs NI-9229<\/h3>\n<p>\nThe NI-9229 provides a wider voltage range, while the NI-9252 provides more channels for \u00b110 V measurement.\n<\/p>\n<table>\n<tr>\n<th>\u0424\u0443\u043d\u043a\u0446\u0438\u044f<\/th>\n<th>NI-9252<\/th>\n<th>NI-9229<\/th>\n<\/tr>\n<tr>\n<td>Input Channels<\/td>\n<td><strong>8<\/strong><\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<td>Input Range<\/td>\n<td>\u00b110 V<\/td>\n<td><strong>\u00b160 V<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u0420\u0430\u0437\u0440\u0435\u0448\u0435\u043d\u0438\u0435<\/td>\n<td>24 Bit<\/td>\n<td>24 Bit<\/td>\n<\/tr>\n<tr>\n<td>Sample Rate<\/td>\n<td>50 kS\/s\/ch<\/td>\n<td>50 kS\/s\/ch<\/td>\n<\/tr>\n<tr>\n<td>Best Fit<\/td>\n<td>Higher Channel Count \u00b110 V<\/td>\n<td>Higher Voltage Measurement<\/td>\n<\/tr>\n<\/table>\n<h3>NI-9252 vs NI-9320<\/h3>\n<p>\nThe NI-9252 emphasizes high resolution and synchronized multi-channel acquisition, while the NI-9320 is designed for applications requiring higher general-purpose sampling performance and additional channels.\n<\/p>\n<table>\n<tr>\n<th>\u0424\u0443\u043d\u043a\u0446\u0438\u044f<\/th>\n<th>NI-9252<\/th>\n<th>NI-9320<\/th>\n<\/tr>\n<tr>\n<td>Analog Inputs<\/td>\n<td>8<\/td>\n<td>16<\/td>\n<\/tr>\n<tr>\n<td>Input Range<\/td>\n<td>\u00b110 V<\/td>\n<td>\u00b110 V<\/td>\n<\/tr>\n<tr>\n<td>\u0420\u0430\u0437\u0440\u0435\u0448\u0435\u043d\u0438\u0435<\/td>\n<td><strong>24 Bit<\/strong><\/td>\n<td>16 Bit<\/td>\n<\/tr>\n<tr>\n<td>Maximum Sampling<\/td>\n<td>50 kS\/s\/ch<\/td>\n<td>Up to 200 kS\/s<\/td>\n<\/tr>\n<tr>\n<td>Primary Strength<\/td>\n<td><strong>High Resolution + Filtering<\/strong><\/td>\n<td>Higher Channel Count \/ Faster General DAQ<\/td>\n<\/tr>\n<\/table>\n<h3>NI-9252 with CompactDAQ<\/h3>\n<p>\nA CompactDAQ system using the NI-9252 is suitable for PC-based measurements.\n<\/p>\n<p>\nA typical system includes:\n<\/p>\n<ul>\n<li>CompactDAQ chassis<\/li>\n<li>NI-9252 module<\/li>\n<li>Additional C Series modules<\/li>\n<li>Host computer<\/li>\n<li>\u041d\u0418-DAQmx<\/li>\n<li>LabVIEW or other supported software<\/li>\n<\/ul>\n<p>\nCompactDAQ is generally well suited for laboratory, automated test, and data-logging systems.\n<\/p>\n<h3>NI-9252 with CompactRIO<\/h3>\n<p>\nA CompactRIO system can combine the NI-9252 with embedded processing, real-time software, and compatible FPGA resources.\n<\/p>\n<p>\nA typical architecture is:\n<\/p>\n<p>\n<strong>Voltage Signals \u2192 NI-9252 \u2192 CompactRIO \u2192 Real-Time \/ FPGA Processing \u2192 Control or Logging<\/strong>\n<\/p>\n<p>\nThis is useful for industrial monitoring, embedded test, deterministic control, and distributed measurement applications.\n<\/p>\n<h3>NI-DAQmx Integration<\/h3>\n<p>\nWhen used in compatible CompactDAQ hardware, the NI-9252 can be configured through <strong>\u041d\u0418-DAQmx<\/strong>.\n<\/p>\n<p>\nTypical configuration tasks include:\n<\/p>\n<ul>\n<li>Create analog input channels<\/li>\n<li>Select input range<\/li>\n<li>Configure sample rate<\/li>\n<li>Configure acquisition timing<\/li>\n<li>Configure supported hardware filtering<\/li>\n<li>Start acquisition<\/li>\n<li>Read measurement data<\/li>\n<li>Log or analyze data<\/li>\n<\/ul>\n<h3>LabVIEW Integration<\/h3>\n<p>\nThe NI-9252 can be integrated into compatible <strong>\u041b\u0430\u0431\u0412\u044c\u044e<\/strong> applications for measurement, automated testing, monitoring, and data logging.\n<\/p>\n<p>\nA typical workflow is:\n<\/p>\n<p>\n<strong>Configure Module \u2192 Create Channels \u2192 Configure Timing \u2192 Acquire Data \u2192 Filter \/ Analyze \u2192 Display \/ Log Results<\/strong>\n<\/p>\n<h3>CompactRIO FPGA Applications<\/h3>\n<p>\nWhen installed in a compatible CompactRIO system, NI-9252 data can be incorporated into FPGA and real-time architectures depending on the chassis and programming mode.\n<\/p>\n<p>\nApplications can include:\n<\/p>\n<ul>\n<li>Real-time threshold monitoring<\/li>\n<li>Embedded condition monitoring<\/li>\n<li>Closed-loop test systems<\/li>\n<li>FPGA-based event detection<\/li>\n<li>Industrial diagnostics<\/li>\n<\/ul>\n<h3>Signal Wiring Considerations<\/h3>\n<p>\nBefore connecting signals to the NI-9252, verify:\n<\/p>\n<ul>\n<li>Signal voltage range<\/li>\n<li>Differential wiring<\/li>\n<li>Signal source grounding<\/li>\n<li>Common-mode voltage<\/li>\n<li>Cable shielding<\/li>\n<li>Electrical noise<\/li>\n<li>Connector type<\/li>\n<li>Terminal plug or D-SUB harness<\/li>\n<\/ul>\n<p>\nIncorrect grounding or wiring can reduce measurement accuracy even when the signal amplitude is within the nominal \u00b110 V input range.\n<\/p>\n<h3>Noise Reduction<\/h3>\n<p>\nHigh-resolution measurement systems require careful attention to electrical noise.\n<\/p>\n<p>\nNoise can be reduced through:\n<\/p>\n<ul>\n<li>Proper differential wiring<\/li>\n<li>Shielded cables<\/li>\n<li>Shorter signal paths where practical<\/li>\n<li>Correct grounding<\/li>\n<li>Appropriate hardware filter selection<\/li>\n<li>Separation from high-power switching equipment<\/li>\n<\/ul>\n<h3>Legacy System Replacement<\/h3>\n<p>\nWhen replacing an existing NI-9252, verify more than the model number.\n<\/p>\n<p>\nImportant compatibility factors include:\n<\/p>\n<ul>\n<li>Exact part number<\/li>\n<li>Screw terminal or D-SUB configuration<\/li>\n<li>CompactDAQ or CompactRIO chassis model<\/li>\n<li>Required sample rate<\/li>\n<li>Required filter configuration<\/li>\n<li>Existing terminal plug or cable<\/li>\n<li>NI-DAQmx version<\/li>\n<li>LabVIEW version<\/li>\n<li>CompactRIO software environment<\/li>\n<li>Operating system compatibility<\/li>\n<\/ul>\n<h3>How to Choose a C Series Voltage Input Module<\/h3>\n<p>\nBefore selecting the NI-9252, determine:\n<\/p>\n<ul>\n<li>Required analog input channel count<\/li>\n<li>Required voltage range<\/li>\n<li>Required sample rate per channel<\/li>\n<li>Required analog resolution<\/li>\n<li>Need for synchronized acquisition<\/li>\n<li>Noise-filtering requirements<\/li>\n<li>CompactDAQ or CompactRIO platform<\/li>\n<li>Terminal or D-SUB connection preference<\/li>\n<li>Isolation requirements<\/li>\n<li>Software and driver compatibility<\/li>\n<\/ul>\n<h3>Industries<\/h3>\n<ul>\n<li>Automated Test<\/li>\n<li>Industrial Measurement<\/li>\n<li>Electronic Validation<\/li>\n<li>Research and Development<\/li>\n<li>Laboratory Automation<\/li>\n<li>Manufacturing Test<\/li>\n<li>Control-System Testing<\/li>\n<li>\u042d\u043d\u0435\u0440\u0433\u0435\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0441\u0438\u0441\u0442\u0435\u043c\u044b<\/li>\n<li>Automotive Testing<\/li>\n<li>Aerospace Testing<\/li>\n<\/ul>\n<h3>Applications<\/h3>\n<h4>Multi-Channel Voltage Measurement<\/h4>\n<p>\nThe NI-9252 provides eight \u00b110 V analog input channels for synchronized multi-channel voltage acquisition.\n<\/p>\n<h4>Automated Test<\/h4>\n<p>\nThe module can acquire multiple DUT voltage signals as part of CompactDAQ or CompactRIO automated test systems.\n<\/p>\n<h4>Electronic Validation<\/h4>\n<p>\nHigh-resolution synchronized voltage inputs are suitable for validating control signals, supply rails, sensor outputs, and analog circuits.\n<\/p>\n<h4>Industrial Monitoring<\/h4>\n<p>\nThe NI-9252 can monitor conditioned voltage outputs from industrial sensors and equipment.\n<\/p>\n<h4>Laboratory Data Acquisition<\/h4>\n<p>\n24-bit resolution and programmable hardware filtering make the NI-9252 useful for laboratory measurement and research applications.\n<\/p>\n<h4>CompactRIO Measurement<\/h4>\n<p>\nThe module can be incorporated into embedded CompactRIO systems requiring synchronized analog voltage acquisition.\n<\/p>\n<h3>Recommended Related Products<\/h3>\n<table>\n<tr>\n<td width=\"220\"><strong>NI-9252<\/strong><\/td>\n<td>8-channel, \u00b110 V, 24-bit, 50 kS\/s\/ch C Series voltage input module with programmable filtering.<\/td>\n<\/tr>\n<tr>\n<td><strong>NI-9239<\/strong><\/td>\n<td>4-channel, \u00b110 V, 24-bit, 50 kS\/s\/ch simultaneous voltage input module.<\/td>\n<\/tr>\n<tr>\n<td><strong>NI-9229<\/strong><\/td>\n<td>4-channel, \u00b160 V, 24-bit, 50 kS\/s\/ch module for higher-voltage measurements.<\/td>\n<\/tr>\n<tr>\n<td><strong>NI-9242<\/strong><\/td>\n<td>C Series module for higher-voltage electrical and power measurement applications.<\/td>\n<\/tr>\n<tr>\n<td><strong>NI-9320<\/strong><\/td>\n<td>16-channel \u00b110 V module for applications requiring higher channel count and different sampling performance.<\/td>\n<\/tr>\n<\/table>\n<h3>Why Choose NI-9252?<\/h3>\n<ul>\n<li>8 differential analog input channels<\/li>\n<li>\u00b110 V measurement range<\/li>\n<li>24-bit resolution<\/li>\n<li>50 kS\/s per channel<\/li>\n<li>Synchronized multi-channel acquisition<\/li>\n<li>Programmable hardware filtering<\/li>\n<li>Butterworth filter options<\/li>\n<li>Comb filter options<\/li>\n<li>CompactDAQ compatibility<\/li>\n<li>CompactRIO compatibility<\/li>\n<li>Screw-terminal configuration available<\/li>\n<li>D-SUB configuration available<\/li>\n<li>Suitable for automated test<\/li>\n<li>Suitable for electronic validation<\/li>\n<li>Suitable for industrial measurement<\/li>\n<li>Suitable for laboratory research<\/li>\n<\/ul>\n<h3>Frequently Asked Questions<\/h3>\n<h4>What is the NI-9252?<\/h4>\n<p>\nThe NI-9252 is an 8-channel C Series analog voltage input module that provides a \u00b110 V input range, 24-bit resolution, and sampling rates up to 50 kS\/s per channel.\n<\/p>\n<h4>How many analog inputs does NI-9252 have?<\/h4>\n<p>\nThe NI-9252 provides <strong>8 differential analog input channels<\/strong>.\n<\/p>\n<h4>What is the input voltage range of NI-9252?<\/h4>\n<p>\nEach channel provides a nominal measurement range of <strong>-10 V to +10 V<\/strong>.\n<\/p>\n<h4>What is the resolution of NI-9252?<\/h4>\n<p>\nThe NI-9252 provides <strong>24-bit analog input resolution<\/strong>.\n<\/p>\n<h4>What is the maximum sampling rate of NI-9252?<\/h4>\n<p>\nThe NI-9252 supports sampling rates up to <strong>50 kS\/s per channel<\/strong>.\n<\/p>\n<h4>Is 50 kS\/s shared across all eight channels?<\/h4>\n<p>\nNo. The NI-9252 is specified at <strong>50 kS\/s per channel<\/strong>, making it suitable for synchronized multi-channel acquisition.\n<\/p>\n<h4>Does NI-9252 support simultaneous sampling?<\/h4>\n<p>\nThe NI-9252 is designed for synchronized multi-channel acquisition across its eight analog input channels, making it suitable for measurements where channel timing relationships are important.\n<\/p>\n<h4>Does NI-9252 have hardware filtering?<\/h4>\n<p>\nYes. The NI-9252 includes programmable hardware filters, including configurable Butterworth and comb filtering options.\n<\/p>\n<h4>What are the NI-9252 part numbers?<\/h4>\n<p>\nThe main configurations are <strong>786782-01<\/strong> for the screw-terminal version and <strong>786783-01<\/strong> for the D-SUB version.\n<\/p>\n<h4>What is the difference between NI-9252 786782-01 and 786783-01?<\/h4>\n<p>\nThe primary difference is the front connection. Part number 786782-01 uses a screw-terminal connection, while 786783-01 uses a D-SUB connection.\n<\/p>\n<h4>Does the screw-terminal NI-9252 include a terminal plug?<\/h4>\n<p>\nNI lists the <strong>NI-9970 18-position screw terminal plug<\/strong> with the screw-terminal configuration, part number 786782-01.\n<\/p>\n<h4>Can NI-9252 be used with CompactDAQ?<\/h4>\n<p>\nYes. The NI-9252 is designed for compatible CompactDAQ chassis and can be used for PC-based data acquisition and automated test.\n<\/p>\n<h4>Can NI-9252 be used with CompactRIO?<\/h4>\n<p>\nYes. The module is also compatible with supported CompactRIO hardware for embedded measurement, monitoring, and control applications.\n<\/p>\n<h4>What is the difference between NI-9252 and NI-9239?<\/h4>\n<p>\nBoth provide \u00b110 V input, 24-bit resolution, and 50 kS\/s\/ch acquisition. The NI-9252 provides <strong>8 \u0430\u043d\u0430\u043b\u043e\u0433\u043e\u0432\u044b\u0445 \u0432\u0445\u043e\u0434\u043d\u044b\u0445 \u043a\u0430\u043d\u0430\u043b\u043e\u0432<\/strong>, while the NI-9239 provides four.\n<\/p>\n<h4>What is the difference between NI-9252 and NI-9229?<\/h4>\n<p>\nThe NI-9252 provides eight \u00b110 V channels, while the NI-9229 provides four channels with a wider \u00b160 V input range. Choose according to required voltage range and channel count.\n<\/p>\n<h4>Can NI-9252 measure thermocouples directly?<\/h4>\n<p>\nThe NI-9252 is primarily a voltage input module. Dedicated thermocouple measurement typically requires cold-junction compensation and sensor-specific signal conditioning, so a C Series temperature module is generally more appropriate.\n<\/p>\n<h4>Can NI-9252 measure current directly?<\/h4>\n<p>\nThe NI-9252 measures voltage rather than current directly. Current signals require an appropriate shunt or signal-conditioning arrangement, or a dedicated C Series current input module.\n<\/p>\n<h4>What should I check before purchasing NI-9252?<\/h4>\n<p>\nVerify the required eight-channel configuration, \u00b110 V range, 24-bit resolution, 50 kS\/s\/ch rate, hardware filtering requirements, CompactDAQ or CompactRIO chassis compatibility, screw-terminal or D-SUB connection, NI-DAQmx or CompactRIO software compatibility, and existing wiring.\n<\/p>\n<h3>\u0417\u0430\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435<\/h3>\n<p>\n\u0417\u0435\u043c\u043b\u044f <strong>NI-9252 C Series Voltage Input Module<\/strong> combines eight differential analog input channels, a \u00b110 V measurement range, 24-bit resolution, up to 50 kS\/s per channel, synchronized acquisition, and programmable Butterworth and comb hardware filtering. These capabilities make it particularly suitable for automated test, electronic validation, multi-channel data acquisition, industrial monitoring, research, laboratory measurement, and CompactDAQ or CompactRIO systems.<\/p>","protected":false},"excerpt":{"rendered":"<p>\u041c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u0435 \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u0434\u0438\u0444\u0444\u0435\u0440\u0435\u043d\u0446\u0438\u0430\u043b\u044c\u043d\u044b\u0445 \u0430\u043d\u0430\u043b\u043e\u0433\u043e\u0432\u044b\u0445 \u0432\u0445\u043e\u0434\u043d\u044b\u0445 \u043a\u0430\u043d\u0430\u043b\u043e\u0432: 8<br \/>\n\u041d\u0435 \u0438\u043c\u0435\u0435\u0442 \u043a\u043e\u043d\u0444\u043e\u0440\u043c\u043d\u043e\u0433\u043e \u043f\u043e\u043a\u0440\u044b\u0442\u0438\u044f<br \/>\n\u0414\u0438\u0430\u043f\u0430\u0437\u043e\u043d \u0432\u0445\u043e\u0434\u043d\u043e\u0433\u043e \u0430\u043d\u0430\u043b\u043e\u0433\u043e\u0432\u043e\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f: \u043e\u0442 -10 \u0412 \u0434\u043e 10 \u0412<br \/>\n\u0412 \u043a\u043e\u043c\u043f\u043b\u0435\u043a\u0442 \u0432\u0445\u043e\u0434\u0438\u0442: \u0414\u0430<br \/>\n\u0410\u043d\u0430\u043b\u043e\u0433\u043e\u0432\u043e\u0435 \u0440\u0430\u0437\u0440\u0435\u0448\u0435\u043d\u0438\u0435 \u0432\u0445\u043e\u0434\u0430: 24 \u0431\u0438\u0442\u0430<br \/>\n\u041c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u0430\u044f \u0447\u0430\u0441\u0442\u043e\u0442\u0430 \u0434\u0438\u0441\u043a\u0440\u0435\u0442\u0438\u0437\u0430\u0446\u0438\u0438: 50 \u043a\u0432\u044b\u0431\/\u0441\/\u043a\u0430\u043d<br \/>\n\u041c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u043e\u0435 \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u043e\u0434\u043d\u043e\u043a\u043e\u043d\u0446\u043e\u0432\u044b\u0445 \u0430\u043d\u0430\u043b\u043e\u0433\u043e\u0432\u044b\u0445 \u0432\u0445\u043e\u0434\u043d\u044b\u0445 \u043a\u0430\u043d\u0430\u043b\u043e\u0432: 0<br \/>\n\u041e\u0434\u043d\u043e\u0432\u0440\u0435\u043c\u0435\u043d\u043d\u0430\u044f \u0432\u044b\u0431\u043e\u0440\u043a\u0430: \u0414\u0430<br \/>\n\u041f\u043e\u0434\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u043c\u0430\u044f \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u0430\u044f \u043f\u043b\u0430\u0442\u0444\u043e\u0440\u043c\u0430: \u0421\u0435\u0440\u0438\u044f C<\/p>","protected":false},"featured_media":31059,"template":"","meta":{"_acf_changed":false},"product_brand":[18],"product_cat":[766],"product_tag":[],"class_list":["post-29458","product","type-product","status-publish","has-post-thumbnail","product_brand-national-instruments","product_cat-c-series-analog-input-module","first","instock","shipping-taxable","purchasable","product-type-simple"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.0 (Yoast SEO v28.1) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>NI-9252 C Series Voltage Input Module 786783-01, In Stock | Project Pricing<\/title>\n<meta name=\"description\" content=\"NI-9252 is an 8-channel C Series voltage input module with \u00b110 V range, 24-bit resolution, 50 kS\/s\/ch sampling and programmable hardware filtering for CompactDAQ and CompactRIO.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/pxisource.com\/ru\/product\/ni-9252\/\" \/>\n<meta property=\"og:locale\" content=\"ru_RU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"NI-9252\" \/>\n<meta property=\"og:description\" content=\"NI-9252 is an 8-channel C Series voltage input module with \u00b110 V range, 24-bit resolution, 50 kS\/s\/ch sampling and programmable hardware filtering for CompactDAQ and CompactRIO.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/pxisource.com\/ru\/product\/ni-9252\/\" \/>\n<meta property=\"og:site_name\" content=\"PXI Source\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=61582573040385\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-27T12:21:32+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/NI-9252.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"800\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u0426\u0435\u043d\u0430\" \/>\n\t<meta name=\"twitter:data1\" content=\"&#036;1,771.00\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c\" \/>\n\t<meta name=\"twitter:data2\" content=\"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/ni-9252\\\/\",\"url\":\"https:\\\/\\\/pxisource.com\\\/product\\\/ni-9252\\\/\",\"name\":\"NI-9252 C Series Voltage Input Module 786783-01, In Stock | Project Pricing\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/ni-9252\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/ni-9252\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/NI-9252.webp\",\"datePublished\":\"2025-09-17T06:24:17+00:00\",\"dateModified\":\"2026-08-27T12:21:32+00:00\",\"description\":\"NI-9252 is an 8-channel C Series voltage input module with \u00b110 V range, 24-bit resolution, 50 kS\\\/s\\\/ch sampling and programmable hardware filtering for CompactDAQ and CompactRIO.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/ni-9252\\\/#breadcrumb\"},\"inLanguage\":\"ru-RU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/pxisource.com\\\/product\\\/ni-9252\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/ni-9252\\\/#primaryimage\",\"url\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/NI-9252.webp\",\"contentUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/NI-9252.webp\",\"width\":800,\"height\":800,\"caption\":\"NI-9252\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/ni-9252\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/pxisource.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u5546\u5e97\",\"item\":\"https:\\\/\\\/pxisource.com\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"NI-9252\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\",\"url\":\"https:\\\/\\\/pxisource.com\\\/\",\"name\":\"PXI Systems\",\"description\":\"PXI, PXIe and Modular Test Equipment\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/pxisource.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ru-RU\"}]}<\/script>\n<meta property=\"product:brand\" content=\"National Instruments\" \/>\n<meta property=\"product:price:amount\" content=\"1771.00\" \/>\n<meta property=\"product:price:currency\" content=\"USD\" \/>\n<meta property=\"og:availability\" content=\"instock\" \/>\n<meta property=\"product:availability\" content=\"instock\" \/>\n<meta property=\"product:condition\" content=\"new\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"NI-9252 C Series Voltage Input Module 786783-01, In Stock | Project Pricing","description":"NI-9252 is an 8-channel C Series voltage input module with \u00b110 V range, 24-bit resolution, 50 kS\/s\/ch sampling and programmable hardware filtering for CompactDAQ and CompactRIO.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/pxisource.com\/ru\/product\/ni-9252\/","og_locale":"ru_RU","og_type":"article","og_title":"NI-9252","og_description":"NI-9252 is an 8-channel C Series voltage input module with \u00b110 V range, 24-bit resolution, 50 kS\/s\/ch sampling and programmable hardware filtering for CompactDAQ and CompactRIO.","og_url":"https:\/\/pxisource.com\/ru\/product\/ni-9252\/","og_site_name":"PXI Source","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=61582573040385","article_modified_time":"2026-08-27T12:21:32+00:00","og_image":[{"width":800,"height":800,"url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/NI-9252.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"\u0426\u0435\u043d\u0430":"&#36;1,771.00","\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c":"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/pxisource.com\/product\/ni-9252\/","url":"https:\/\/pxisource.com\/product\/ni-9252\/","name":"NI-9252 C Series Voltage Input Module 786783-01, In Stock | Project Pricing","isPartOf":{"@id":"https:\/\/pxisource.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/pxisource.com\/product\/ni-9252\/#primaryimage"},"image":{"@id":"https:\/\/pxisource.com\/product\/ni-9252\/#primaryimage"},"thumbnailUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/NI-9252.webp","datePublished":"2025-09-17T06:24:17+00:00","dateModified":"2026-08-27T12:21:32+00:00","description":"NI-9252 is an 8-channel C Series voltage input module with \u00b110 V range, 24-bit resolution, 50 kS\/s\/ch sampling and programmable hardware filtering for CompactDAQ and CompactRIO.","breadcrumb":{"@id":"https:\/\/pxisource.com\/product\/ni-9252\/#breadcrumb"},"inLanguage":"ru-RU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/pxisource.com\/product\/ni-9252\/"]}]},{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/pxisource.com\/product\/ni-9252\/#primaryimage","url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/NI-9252.webp","contentUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/NI-9252.webp","width":800,"height":800,"caption":"NI-9252"},{"@type":"BreadcrumbList","@id":"https:\/\/pxisource.com\/product\/ni-9252\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/pxisource.com\/"},{"@type":"ListItem","position":2,"name":"\u5546\u5e97","item":"https:\/\/pxisource.com\/shop\/"},{"@type":"ListItem","position":3,"name":"NI-9252"}]},{"@type":"WebSite","@id":"https:\/\/pxisource.com\/#website","url":"https:\/\/pxisource.com\/","name":"\u0421\u0438\u0441\u0442\u0435\u043c\u044b PXI","description":"PXI, PXIe and Modular Test Equipment","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/pxisource.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ru-RU"}]},"product_brand":"National Instruments","product_price_amount":"1771.00","product_price_currency":"USD","og_availability":"instock","product_availability":"instock","product_condition":"new"},"_links":{"self":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/29458","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":5,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/29458\/revisions"}],"predecessor-version":[{"id":35531,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/29458\/revisions\/35531"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media\/31059"}],"wp:attachment":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media?parent=29458"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_brand?post=29458"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_cat?post=29458"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_tag?post=29458"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}