{"id":28999,"date":"2025-09-16T13:13:47","date_gmt":"2025-09-16T05:13:47","guid":{"rendered":"https:\/\/pxisource.com\/?post_type=product&#038;p=28999"},"modified":"2026-08-27T21:42:08","modified_gmt":"2026-08-27T13:42:08","slug":"pxie-6509","status":"publish","type":"product","link":"https:\/\/pxisource.com\/ru\/product\/pxie-6509\/","title":{"rendered":"PXIe-6509"},"content":{"rendered":"<h3>Product Introduction<\/h3>\n<p>\n\u0417\u0435\u043c\u043b\u044f <strong>PXIe\u20116509<\/strong> \u044f\u0432\u043b\u044f\u0435\u0442\u0441\u044f <strong>96-channel, 5 V TTL\/CMOS PXI Express digital I\/O module<\/strong> designed for high-density device control, switch monitoring, relay operation, test-fixture control and automated functional testing.\n<\/p>\n<p>\nEach digital line can be independently configured as an input or output. The module provides up to <strong>24 mA of current drive per channel<\/strong>, allowing it to directly control compatible external digital devices such as solid-state relays and indicators.\n<\/p>\n<p>\nThe PXIe\u20116509 also provides programmable power-up states, software-selectable pull-up or pull-down resistors, digital input filtering, change detection and a digital watchdog timer for controlled recovery from software or communication faults.\n<\/p>\n<h3>Product Overview<\/h3>\n<p>\n\u0417\u0435\u043c\u043b\u044f <strong>National Instruments PXIe\u20116509<\/strong> belongs to the NI industrial digital I\/O product family. Its standard NI part number is <strong>787358\u201101<\/strong>.\n<\/p>\n<p>\nThe module provides 96 bidirectional digital lines organized as 12 eight-bit ports. Each line can be used as a static digital input or output, while pull resistor settings are configurable by port.\n<\/p>\n<p>\nA typical system architecture is:\n<\/p>\n<p>\n<strong>Switches \/ Sensors \/ Relays \/ DUT \u2194 PXIe\u20116509 \u2194 PXI Express Chassis \u2194 PXI Controller \u2194 NI\u2011DAQmx Application<\/strong>\n<\/p>\n<p>\nThe PXIe\u20116509 is particularly useful when an automated test system requires a large number of software-controlled digital inputs and outputs within a single PXI Express slot.\n<\/p>\n<h3>Key Features<\/h3>\n<h4>96 Bidirectional Digital I\/O Channels<\/h4>\n<p>\nThe PXIe\u20116509 provides <strong>96 bidirectional digital I\/O channels<\/strong>.\n<\/p>\n<p>\nThe channels are organized as:\n<\/p>\n<ul>\n<li>12 digital ports<\/li>\n<li>Eight digital lines per port<\/li>\n<li>96 total software-configurable lines<\/li>\n<\/ul>\n<p>\nThe high channel density allows one module to monitor and control multiple switches, sensors, relays, indicators and DUT interface signals.\n<\/p>\n<h4>Independent Input and Output Configuration<\/h4>\n<p>\nEach digital line can be independently configured as an input or output.\n<\/p>\n<p>\nThis allows engineers to create mixed configurations such as:\n<\/p>\n<ul>\n<li>64 digital inputs and 32 digital outputs<\/li>\n<li>48 digital inputs and 48 digital outputs<\/li>\n<li>All 96 channels as digital inputs<\/li>\n<li>All 96 channels as digital outputs<\/li>\n<li>Application-specific combinations of input and output lines<\/li>\n<\/ul>\n<p>\nThe configuration can be adapted to the exact requirements of a test fixture or DUT interface.\n<\/p>\n<h4>5 V TTL\/CMOS Compatibility<\/h4>\n<p>\nThe PXIe\u20116509 is designed for <strong>5 V TTL\/CMOS-compatible digital signals<\/strong>.\n<\/p>\n<p>\nIt can interface with compatible:\n<\/p>\n<ul>\n<li>Digital sensors<\/li>\n<li>Logic circuits<\/li>\n<li>Embedded controllers<\/li>\n<li>Test fixtures<\/li>\n<li>Solid-state relays<\/li>\n<li>Switches and push buttons<\/li>\n<li>Status indicators<\/li>\n<li>Electronic subsystems<\/li>\n<\/ul>\n<p>\nThe module uses single-ended, ground-referenced digital I\/O and does not provide channel-to-channel isolation.\n<\/p>\n<h4>24 mA Output Drive<\/h4>\n<p>\nEach PXIe\u20116509 digital output can provide up to <strong>24 mA of current drive<\/strong> under the specified electrical conditions.\n<\/p>\n<p>\nThe higher drive capability allows the module to control compatible external devices such as:\n<\/p>\n<ul>\n<li>Solid-state relays<\/li>\n<li>LED indicators with appropriate current limiting<\/li>\n<li>Digital logic inputs<\/li>\n<li>Test-fixture control circuits<\/li>\n<li>Interface boards<\/li>\n<li>Low-current actuator-control inputs<\/li>\n<\/ul>\n<p>\nThe connected load must remain within the documented per-channel and total-device current limits.\n<\/p>\n<h4>Programmable Power-Up States<\/h4>\n<p>\nThe PXIe\u20116509 supports programmable digital power-up states.\n<\/p>\n<p>\nThe initial output state of each configured line can be defined in software as:\n<\/p>\n<ul>\n<li>Logic high<\/li>\n<li>Logic low<\/li>\n<li>Input state where supported<\/li>\n<\/ul>\n<p>\nProgrammable power-up states help ensure that connected relays, fixtures and control signals start in a known condition when the PXI system powers on or resets.\n<\/p>\n<h4>Software-Selectable Pull-Up and Pull-Down Resistors<\/h4>\n<p>\nEach eight-bit port can be configured with a software-selectable pull-up or pull-down resistor.\n<\/p>\n<p>\nThe typical resistor values are:\n<\/p>\n<ul>\n<li>4.7 k\u03a9 pull-up<\/li>\n<li>47 k\u03a9 pull-down<\/li>\n<\/ul>\n<p>\nPull resistors help prevent undriven input lines from floating and can establish a known default logic state when the external signal source is disconnected or in a high-impedance state.\n<\/p>\n<h4>Digital Input Filtering<\/h4>\n<p>\nThe PXIe\u20116509 provides programmable digital input filters.\n<\/p>\n<p>\nDigital filtering can help:\n<\/p>\n<ul>\n<li>Reject short glitches<\/li>\n<li>Remove electrical spikes<\/li>\n<li>Debounce mechanical switches<\/li>\n<li>Debounce relay contacts<\/li>\n<li>Improve input-state stability<\/li>\n<li>Reduce false change-detection events<\/li>\n<\/ul>\n<p>\nFilter settings should be selected according to the expected signal rate and the duration of unwanted transitions.\n<\/p>\n<h4>Digital Change Detection<\/h4>\n<p>\nThe PXIe\u20116509 supports digital change detection, allowing the module to notify the application when selected input lines change state.\n<\/p>\n<p>\nThis can reduce the need for continuous software polling in applications such as:\n<\/p>\n<ul>\n<li>Switch monitoring<\/li>\n<li>Alarm input detection<\/li>\n<li>Fixture-interlock monitoring<\/li>\n<li>DUT status monitoring<\/li>\n<li>Operator-control panels<\/li>\n<li>Digital event detection<\/li>\n<\/ul>\n<p>\nThe device provides one shared change-detection resource, so applications should normally combine required lines into a single change-detection task.\n<\/p>\n<h4>Digital I\/O Watchdog Timer<\/h4>\n<p>\nThe PXIe\u20116509 includes a digital watchdog timer that can place output channels into configurable safe states if the controlling application stops communicating with the device.\n<\/p>\n<p>\nA watchdog can help respond to:\n<\/p>\n<ul>\n<li>Application failure<\/li>\n<li>Operating-system failure<\/li>\n<li>Communication interruption<\/li>\n<li>Test-sequence timeout<\/li>\n<li>Unexpected software termination<\/li>\n<\/ul>\n<p>\nThe safe-state behavior must be configured and tested according to the requirements of the complete system.\n<\/p>\n<h4>Static Software-Timed Digital I\/O<\/h4>\n<p>\nPXIe\u20116509 digital input samples and digital output updates are software-timed.\n<\/p>\n<p>\nThe module is optimized for static and event-driven digital control rather than deterministic high-speed digital waveform acquisition or generation.\n<\/p>\n<p>\nTypical uses include:\n<\/p>\n<ul>\n<li>Relay switching<\/li>\n<li>Switch-state monitoring<\/li>\n<li>Fixture control<\/li>\n<li>Test-mode selection<\/li>\n<li>DUT configuration<\/li>\n<li>Pass\/fail indicator control<\/li>\n<\/ul>\n<h4>Fused 5 V Power Output<\/h4>\n<p>\nThe PXIe\u20116509 I\/O connector provides a fused 5 V power output for compatible external circuits.\n<\/p>\n<p>\nThis auxiliary supply can simplify connections to low-power interface electronics, pull resistors and compatible digital accessories.\n<\/p>\n<p>\nThe total current drawn from the connector must remain within the documented limit.\n<\/p>\n<h3>Technical Specifications<\/h3>\n<table>\n<tr>\n<th>\u041f\u0430\u0440\u0430\u043c\u0435\u0442\u0440<\/th>\n<th>\u0421\u043f\u0435\u0446\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f<\/th>\n<\/tr>\n<tr>\n<td width=\"280\">Product Type<\/td>\n<td>PXI Express Digital I\/O Module<\/td>\n<\/tr>\n<tr>\n<td>\u041c\u043e\u0434\u0435\u043b\u044c<\/td>\n<td>PXIe\u20116509<\/td>\n<\/tr>\n<tr>\n<td>Part Number<\/td>\n<td><strong>787358\u201101<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Manufacturer<\/td>\n<td>\u041d\u0430\u0446\u0438\u043e\u043d\u0430\u043b\u044c\u043d\u044b\u0435 \u0438\u043d\u0441\u0442\u0440\u0443\u043c\u0435\u043d\u0442\u044b<\/td>\n<\/tr>\n<tr>\n<td>\u0428\u0438\u043d\u043d\u044b\u0439 \u0438\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441<\/td>\n<td>PXI Express<\/td>\n<\/tr>\n<tr>\n<td>Digital I\/O Channels<\/td>\n<td><strong>96 Bidirectional Channels<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Port Organization<\/td>\n<td>12 Ports, 8 Lines per Port<\/td>\n<\/tr>\n<tr>\n<td>Direction Configuration<\/td>\n<td>Independently Configurable by Line<\/td>\n<\/tr>\n<tr>\n<td>\u0422\u0438\u043f \u0441\u0438\u0433\u043d\u0430\u043b\u0430<\/td>\n<td>Single-Ended, Ground Referenced<\/td>\n<\/tr>\n<tr>\n<td>Logic Compatibility<\/td>\n<td>5 V TTL\/CMOS<\/td>\n<\/tr>\n<tr>\n<td>Output Current Drive<\/td>\n<td><strong>Up to 24 mA per Channel<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Input Pull Configuration<\/td>\n<td>Software-Selectable Pull-Up or Pull-Down by Port<\/td>\n<\/tr>\n<tr>\n<td>Pull-Up Resistance<\/td>\n<td>4.7 k\u03a9 Typical<\/td>\n<\/tr>\n<tr>\n<td>Pull-Down Resistance<\/td>\n<td>47 k\u03a9 Typical<\/td>\n<\/tr>\n<tr>\n<td>Power-Up States<\/td>\n<td>Programmable Input, Output High or Output Low<\/td>\n<\/tr>\n<tr>\n<td>Digital Filtering<\/td>\n<td>Programmable Input Filters<\/td>\n<\/tr>\n<tr>\n<td>Change Detection<\/td>\n<td>Supported<\/td>\n<\/tr>\n<tr>\n<td>Watchdog Timer<\/td>\n<td>Supported<\/td>\n<\/tr>\n<tr>\n<td>Digital Timing<\/td>\n<td>Software-Timed Static I\/O<\/td>\n<\/tr>\n<tr>\n<td>Data Transfer<\/td>\n<td>Interrupts and Programmed I\/O<\/td>\n<\/tr>\n<tr>\n<td>I\/O Connector<\/td>\n<td>100-Pin Female 0.050-Series SCSI<\/td>\n<\/tr>\n<tr>\n<td>Connector Power Output<\/td>\n<td>Fused 5 V Output<\/td>\n<\/tr>\n<tr>\n<td>\u0418\u0437\u043e\u043b\u044f\u0446\u0438\u044f<\/td>\n<td>Nonisolated<\/td>\n<\/tr>\n<tr>\n<td>Recommended Cable<\/td>\n<td>Compatible 100-Pin Shielded Cable<\/td>\n<\/tr>\n<tr>\n<td>Software Driver<\/td>\n<td>NI\u2011DAQmx<\/td>\n<\/tr>\n<tr>\n<td>Primary Applications<\/td>\n<td>Relay Control, Switch Monitoring, Fixture Control and Automated Test<\/td>\n<\/tr>\n<\/table>\n<h3>How Does the PXIe\u20116509 Work?<\/h3>\n<p>\nThe PXIe\u20116509 provides a software-controlled interface between a PXI Express test system and external TTL\/CMOS digital devices.\n<\/p>\n<p>\nFor digital input applications, the signal path is:\n<\/p>\n<p>\n<strong>Switch \/ Sensor \/ DUT Output \u2192 PXIe\u20116509 Digital Input \u2192 Change Detection or Software Read \u2192 PXI Controller<\/strong>\n<\/p>\n<p>\nFor digital output applications, the signal path is:\n<\/p>\n<p>\n<strong>PXI Application \u2192 NI\u2011DAQmx \u2192 PXIe\u20116509 Digital Output \u2192 Relay \/ Indicator \/ DUT Input<\/strong>\n<\/p>\n<p>\nNI\u2011DAQmx configures line direction, power-up state, pull resistor, filtering, change detection and watchdog behavior.\n<\/p>\n<h3>96-Channel Port Architecture<\/h3>\n<p>\nThe 96 channels are arranged as 12 eight-bit ports, typically identified as Port 0 through Port 11.\n<\/p>\n<p>\nEach line can be configured as a static digital input or output, while pull-up and pull-down settings are selected for each eight-bit port.\n<\/p>\n<p>\nThis architecture provides both high channel density and flexible direction assignment for automated test systems.\n<\/p>\n<h3>Digital Input Applications<\/h3>\n<p>\nWhen configured as inputs, PXIe\u20116509 lines can monitor the logic state of compatible external devices.\n<\/p>\n<p>\nTypical input applications include:\n<\/p>\n<ul>\n<li>Mechanical switch monitoring<\/li>\n<li>Relay contact monitoring<\/li>\n<li>DUT status detection<\/li>\n<li>Fixture interlock monitoring<\/li>\n<li>Limit-switch acquisition<\/li>\n<li>Alarm and fault input monitoring<\/li>\n<li>Operator-panel input acquisition<\/li>\n<li>Production-line status monitoring<\/li>\n<\/ul>\n<p>\nDigital filtering can be enabled when switch bounce or short noise pulses would otherwise cause incorrect state changes.\n<\/p>\n<h3>Digital Output Applications<\/h3>\n<p>\nWhen configured as outputs, PXIe\u20116509 lines can control compatible digital loads and logic inputs.\n<\/p>\n<p>\nTypical output applications include:\n<\/p>\n<ul>\n<li>Solid-state relay control<\/li>\n<li>Indicator control<\/li>\n<li>DUT mode selection<\/li>\n<li>Test-fixture switching<\/li>\n<li>Digital command generation<\/li>\n<li>Multiplexer control<\/li>\n<li>Power-sequencing control inputs<\/li>\n<li>Pass\/fail status indication<\/li>\n<\/ul>\n<p>\nThe module is intended for static software-timed control. Applications requiring precise high-speed digital patterns should use a high-speed digital waveform or pattern instrument.\n<\/p>\n<h3>Direct Solid-State Relay Control<\/h3>\n<p>\nThe 24 mA channel drive capability allows the PXIe\u20116509 to directly control many compatible solid-state relay inputs.\n<\/p>\n<p>\nBefore connecting a solid-state relay, verify:\n<\/p>\n<ul>\n<li>Relay input voltage<\/li>\n<li>Required input current<\/li>\n<li>Turn-on and turn-off thresholds<\/li>\n<li>Polarity<\/li>\n<li>Common-ground requirements<\/li>\n<li>Total module current limits<\/li>\n<\/ul>\n<p>\nElectromechanical relay coils generally require a suitable relay-driver circuit rather than direct connection to a PXIe\u20116509 output.\n<\/p>\n<h3>Programmable Power-Up States<\/h3>\n<p>\nPower-up states allow output lines to enter defined logic conditions when the device initializes.\n<\/p>\n<p>\nA typical configuration process is:\n<\/p>\n<ol>\n<li>Identify outputs connected to relays, actuators or DUT control inputs.<\/li>\n<li>Determine the safest initial logic state for each output.<\/li>\n<li>Configure the required power-up states in NI Measurement &#038; Automation Explorer or NI\u2011DAQmx.<\/li>\n<li>Restart or reset the system.<\/li>\n<li>Verify the physical output states before connecting the final load.<\/li>\n<\/ol>\n<p>\nPower-up states improve startup predictability but do not replace a complete system-level safety design.\n<\/p>\n<h3>Watchdog Safe States<\/h3>\n<p>\nThe digital watchdog monitors communication between the application and the PXIe\u20116509.\n<\/p>\n<p>\nIf the watchdog expires, selected outputs can transition to predefined states.\n<\/p>\n<p>\nPossible watchdog states include:\n<\/p>\n<ul>\n<li>Logic low<\/li>\n<li>Logic high<\/li>\n<li>High-impedance or input state where supported<\/li>\n<\/ul>\n<p>\nThe watchdog timeout and expiration states should be selected according to the behavior required by the DUT, relays and test fixture.\n<\/p>\n<h3>Programmable Input Filtering<\/h3>\n<p>\nMechanical switches and relay contacts can produce multiple transitions when changing state. Electrical interference can also create narrow input pulses.\n<\/p>\n<p>\nThe PXIe\u20116509 input filter can reject transitions shorter than the configured filter interval.\n<\/p>\n<p>\nThis is useful for:\n<\/p>\n<ul>\n<li>Switch debouncing<\/li>\n<li>Relay-contact debouncing<\/li>\n<li>Glitch rejection<\/li>\n<li>Noise-pulse rejection<\/li>\n<li>Stable alarm monitoring<\/li>\n<li>Reliable fixture-state detection<\/li>\n<\/ul>\n<p>\nA filter interval that is too long may reject valid input changes, so the setting must match the expected signal behavior.\n<\/p>\n<h3>Digital Change Detection<\/h3>\n<p>\nChange detection allows selected lines to generate an event when their state changes.\n<\/p>\n<p>\nThe application can monitor:\n<\/p>\n<ul>\n<li>Rising transitions<\/li>\n<li>Falling transitions<\/li>\n<li>Both rising and falling transitions<\/li>\n<\/ul>\n<p>\nChange detection is useful when the application must respond to digital events without continuously reading all 96 lines.\n<\/p>\n<p>\nOnly one change-detection resource is available on the device. All required lines should therefore be configured within one compatible change-detection task.\n<\/p>\n<h3>Static vs High-Speed Digital I\/O<\/h3>\n<table>\n<tr>\n<th>\u0424\u0443\u043d\u043a\u0446\u0438\u044f<\/th>\n<th>PXIe\u20116509 Static DIO<\/th>\n<th>High-Speed Digital Instrument<\/th>\n<\/tr>\n<tr>\n<td>\u041a\u0430\u043d\u0430\u043b\u044b<\/td>\n<td><strong>96<\/strong><\/td>\n<td>Model Dependent<\/td>\n<\/tr>\n<tr>\n<td>Timing<\/td>\n<td>Software-Timed<\/td>\n<td>Hardware-Timed<\/td>\n<\/tr>\n<tr>\n<td>Primary Use<\/td>\n<td>Control and Status Monitoring<\/td>\n<td>Waveform and Protocol Testing<\/td>\n<\/tr>\n<tr>\n<td>Programmable Power-Up States<\/td>\n<td><strong>Supported<\/strong><\/td>\n<td>Model Dependent<\/td>\n<\/tr>\n<tr>\n<td>Watchdog Timer<\/td>\n<td><strong>Supported<\/strong><\/td>\n<td>Model Dependent<\/td>\n<\/tr>\n<tr>\n<td>Digital Filtering<\/td>\n<td><strong>Supported<\/strong><\/td>\n<td>Model Dependent<\/td>\n<\/tr>\n<tr>\n<td>Best For<\/td>\n<td>Relays, Switches and Fixtures<\/td>\n<td>High-Speed Patterns and Buses<\/td>\n<\/tr>\n<\/table>\n<p>\nChoose the PXIe\u20116509 when the application needs high-density static control and monitoring. Choose a hardware-timed digital instrument when precise sample clocks or high-speed waveform generation are required.\n<\/p>\n<h3>Automated Functional Testing<\/h3>\n<p>\nThe PXIe\u20116509 can control and monitor multiple digital signals in an automated functional test system.\n<\/p>\n<p>\nA typical test sequence may include:\n<\/p>\n<ol>\n<li>Initialize the PXI system and NI\u2011DAQmx tasks.<\/li>\n<li>Apply configured power-up and safe states.<\/li>\n<li>Verify fixture-interlock inputs.<\/li>\n<li>Set DUT operating modes through digital outputs.<\/li>\n<li>Activate compatible solid-state relays.<\/li>\n<li>Read DUT status outputs.<\/li>\n<li>Monitor alarm and fault lines.<\/li>\n<li>Record the digital states and pass\/fail result.<\/li>\n<li>Return all outputs to defined safe states.<\/li>\n<\/ol>\n<h3>Production Test Applications<\/h3>\n<p>\nThe high channel count makes the PXIe\u20116509 suitable for production fixtures that require many low-speed control and status signals.\n<\/p>\n<p>\nPotential production uses include:\n<\/p>\n<ul>\n<li>Fixture relay control<\/li>\n<li>DUT configuration<\/li>\n<li>Connector-presence detection<\/li>\n<li>Safety-interlock monitoring<\/li>\n<li>Pass\/fail indicator control<\/li>\n<li>Barcode-station handshaking<\/li>\n<li>Production equipment status monitoring<\/li>\n<li>Automated test sequencing<\/li>\n<\/ul>\n<h3>Industrial Monitoring and Control<\/h3>\n<p>\nThe PXIe\u20116509 can monitor and control compatible 5 V TTL\/CMOS industrial interface circuits.\n<\/p>\n<p>\nBecause the channels are nonisolated and ground referenced, external isolation or signal conditioning may be required when connecting to higher-voltage industrial sensors, long cables or devices with different ground potentials.\n<\/p>\n<h3>Semiconductor and Electronic Validation<\/h3>\n<p>\nThe PXIe\u20116509 can provide static control and monitoring signals for semiconductor and electronic device validation.\n<\/p>\n<p>\nPotential uses include:\n<\/p>\n<ul>\n<li>Device mode selection<\/li>\n<li>Reset-line control<\/li>\n<li>Enable-signal control<\/li>\n<li>Status-bit monitoring<\/li>\n<li>Fixture relay operation<\/li>\n<li>Digital interlock monitoring<\/li>\n<li>Power-sequence control<\/li>\n<li>Automated functional verification<\/li>\n<\/ul>\n<h3>PXI Express System Integration<\/h3>\n<p>\nThe PXIe\u20116509 must be installed in a compatible <a href=\"https:\/\/pxisource.com\/ru\/product-category\/%d0%bd%d0%b8\/pxi-%d1%81%d0%b8%d1%81%d1%82%d0%b5%d0%bc%d1%81\/pxi-chassis\/\">PXI Express chassis<\/a>.\n<\/p>\n<p>\nA complete system normally requires:\n<\/p>\n<ul>\n<li>PXIe\u20116509 digital I\/O module<\/li>\n<li>Compatible PXI Express chassis<\/li>\n<li>Compatible <a href=\"https:\/\/pxisource.com\/ru\/product-category\/%d0%bd%d0%b8\/pxi-%d1%81%d0%b8%d1%81%d1%82%d0%b5%d0%bc%d1%81\/pxi-controller\/\">PXI controller<\/a> or remote-control connection<\/li>\n<li>Compatible 100-pin cable<\/li>\n<li>Terminal block or custom interface board<\/li>\n<li>NI\u2011DAQmx driver<\/li>\n<li>Compatible application software<\/li>\n<\/ul>\n<h3>Cables and Connector Accessories<\/h3>\n<p>\nThe PXIe\u20116509 uses a 100-pin female 0.050-series SCSI connector.\n<\/p>\n<p>\nA complete wiring system may include:\n<\/p>\n<ul>\n<li>Compatible shielded 100-pin cable<\/li>\n<li>SCB-series connector block<\/li>\n<li>CB-series connector block<\/li>\n<li>Custom breakout board<\/li>\n<li>Relay interface board<\/li>\n<li>Appropriate grounding and shielding<\/li>\n<\/ul>\n<p>\nAlways confirm that the selected cable and connector block are specifically compatible with the PXIe\u20116509 pinout.\n<\/p>\n<h3>System Integration Considerations<\/h3>\n<p>\nBefore selecting the PXIe\u20116509, verify:\n<\/p>\n<ul>\n<li>Required number of digital channels<\/li>\n<li>Required input and output allocation<\/li>\n<li>5 V TTL\/CMOS compatibility<\/li>\n<li>Required output current<\/li>\n<li>Need for isolation<\/li>\n<li>Need for hardware-timed operation<\/li>\n<li>Power-up state requirements<\/li>\n<li>Watchdog safe-state requirements<\/li>\n<li>Input filtering requirements<\/li>\n<li>Change-detection requirements<\/li>\n<li>PXI Express chassis compatibility<\/li>\n<li>Cable and connector requirements<\/li>\n<li>NI\u2011DAQmx compatibility<\/li>\n<\/ul>\n<h3>Current Drive Considerations<\/h3>\n<p>\nAlthough each channel can provide up to 24 mA under specified conditions, the total current used by all active outputs must remain within the module limits.\n<\/p>\n<p>\nBefore connecting loads:\n<\/p>\n<ul>\n<li>Check the current required by each load<\/li>\n<li>Calculate the total current for simultaneously active outputs<\/li>\n<li>Confirm output-high and output-low voltage requirements<\/li>\n<li>Use external driver circuits for higher-current loads<\/li>\n<li>Use appropriate flyback protection for inductive loads<\/li>\n<li>Avoid direct connection to relay coils unless specifically supported<\/li>\n<\/ul>\n<h3>Grounding and Isolation Considerations<\/h3>\n<p>\nThe PXIe\u20116509 uses single-ended, ground-referenced I\/O and does not provide channel-to-channel isolation.\n<\/p>\n<p>\nWhen connecting external equipment:\n<\/p>\n<ul>\n<li>Confirm that the grounds are compatible<\/li>\n<li>Avoid large ground-potential differences<\/li>\n<li>Use external isolation for remote equipment when necessary<\/li>\n<li>Keep cables appropriately short for the application<\/li>\n<li>Use shielded wiring in noisy environments<\/li>\n<li>Do not connect signals outside the documented voltage limits<\/li>\n<\/ul>\n<h3>Troubleshooting PXIe\u20116509 Systems<\/h3>\n<p>\nIf the PXIe\u20116509 does not read or generate the expected digital states, check the hardware, wiring and software configuration.\n<\/p>\n<ol>\n<li>Verify that the module is detected in NI Measurement &#038; Automation Explorer.<\/li>\n<li>Confirm that a compatible NI\u2011DAQmx driver is installed.<\/li>\n<li>Check the physical channel and port names.<\/li>\n<li>Verify that each line is configured for the correct direction.<\/li>\n<li>Confirm the external signal uses compatible TTL\/CMOS levels.<\/li>\n<li>Check the ground connection between the module and DUT.<\/li>\n<li>Verify the selected pull-up or pull-down configuration.<\/li>\n<li>Temporarily disable input filtering when testing fast transitions.<\/li>\n<li>Check the configured power-up states.<\/li>\n<li>Verify watchdog timeout and expiration states.<\/li>\n<li>Confirm that only one change-detection task is active.<\/li>\n<li>Inspect the 100-pin cable and connector-block wiring.<\/li>\n<li>Test individual lines with NI\u2011MAX or a basic NI\u2011DAQmx example.<\/li>\n<\/ol>\n<h3>How to Choose a PXI Digital I\/O Module<\/h3>\n<p>\nBefore purchasing a PXI digital I\/O module, determine:\n<\/p>\n<ul>\n<li>Required channel count<\/li>\n<li>Input-only, output-only or bidirectional operation<\/li>\n<li>Logic voltage requirements<\/li>\n<li>Output current requirements<\/li>\n<li>Static or hardware-timed operation<\/li>\n<li>Isolation requirements<\/li>\n<li>Power-up state requirements<\/li>\n<li>Watchdog requirements<\/li>\n<li>Digital filtering requirements<\/li>\n<li>Change-detection requirements<\/li>\n<li>PXI or PXI Express interface requirements<\/li>\n<li>Cable and terminal-block requirements<\/li>\n<\/ul>\n<h3>Industries<\/h3>\n<ul>\n<li>Automated Test Equipment<\/li>\n<li>Electronics Manufacturing<\/li>\n<li>\u0422\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u043f\u043e\u043b\u0443\u043f\u0440\u043e\u0432\u043e\u0434\u043d\u0438\u043a\u043e\u0432<\/li>\n<li>Electronic Design Validation<\/li>\n<li>\u041f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u0430\u044f \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0437\u0430\u0446\u0438\u044f<\/li>\n<li>Automotive Testing<\/li>\n<li>\u0410\u044d\u0440\u043e\u043a\u043e\u0441\u043c\u0438\u0447\u0435\u0441\u043a\u0430\u044f \u0438 \u043e\u0431\u043e\u0440\u043e\u043d\u043d\u0430\u044f \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0441\u0442\u044c<\/li>\n<li>Research and Development<\/li>\n<li>Laboratory Automation<\/li>\n<\/ul>\n<h3>Applications<\/h3>\n<h4>Solid-State Relay Control<\/h4>\n<p>\nThe 24 mA output drive can directly control many compatible solid-state relay inputs.\n<\/p>\n<h4>Switch and Contact Monitoring<\/h4>\n<p>\nDigital inputs, pull resistors and filtering support reliable monitoring of switches, relay contacts and fixture interlocks.\n<\/p>\n<h4>Automated Test-Fixture Control<\/h4>\n<p>\nThe 96 digital lines can control relay banks, DUT modes, indicators and other fixture functions.\n<\/p>\n<h4>DUT Status Monitoring<\/h4>\n<p>\nChange detection can identify transitions on selected alarm, ready, fault and status lines.\n<\/p>\n<h4>Power and Mode Sequencing<\/h4>\n<p>\nProgrammable outputs can control compatible enable, reset and mode-selection inputs in an automated sequence.\n<\/p>\n<h4>Production Functional Test<\/h4>\n<p>\nHigh-density digital control and monitoring can be combined with other PXI instruments in automated production systems.\n<\/p>\n<h3>PXIe\u20116509 vs PXI\u20116509<\/h3>\n<table>\n<tr>\n<th>\u0424\u0443\u043d\u043a\u0446\u0438\u044f<\/th>\n<th>PXIe\u20116509<\/th>\n<th>PXI\u20116509<\/th>\n<\/tr>\n<tr>\n<td>\u0428\u0438\u043d\u043d\u044b\u0439 \u0438\u043d\u0442\u0435\u0440\u0444\u0435\u0439\u0441<\/td>\n<td><strong>PXI Express<\/strong><\/td>\n<td>PXI<\/td>\n<\/tr>\n<tr>\n<td>Digital I\/O Channels<\/td>\n<td>96<\/td>\n<td>96<\/td>\n<\/tr>\n<tr>\n<td>Logic Level<\/td>\n<td>5 V TTL\/CMOS<\/td>\n<td>5 V TTL\/CMOS<\/td>\n<\/tr>\n<tr>\n<td>Output Drive<\/td>\n<td>24 mA<\/td>\n<td>24 mA<\/td>\n<\/tr>\n<tr>\n<td>Direction Configuration<\/td>\n<td><strong>Independently by Line<\/strong><\/td>\n<td>Port Configurable<\/td>\n<\/tr>\n<tr>\n<td>Software-Selectable Pull Resistors<\/td>\n<td><strong>Supported<\/strong><\/td>\n<td>Not Equivalent to PXIe Version<\/td>\n<\/tr>\n<tr>\n<td>Part Number<\/td>\n<td>787358\u201101<\/td>\n<td>Model Dependent<\/td>\n<\/tr>\n<tr>\n<td>Recommended Use<\/td>\n<td>Current PXI Express Systems<\/td>\n<td>Legacy PXI Systems<\/td>\n<\/tr>\n<\/table>\n<h3>PXIe\u20116509 vs PCIe\u20116509<\/h3>\n<table>\n<tr>\n<th>\u0424\u0443\u043d\u043a\u0446\u0438\u044f<\/th>\n<th>PXIe\u20116509<\/th>\n<th>PCIe\u20116509<\/th>\n<\/tr>\n<tr>\n<td>Form Factor<\/td>\n<td><strong>PXI Express<\/strong><\/td>\n<td>Desktop PCI Express<\/td>\n<\/tr>\n<tr>\n<td>Digital I\/O Channels<\/td>\n<td>96<\/td>\n<td>96<\/td>\n<\/tr>\n<tr>\n<td>Logic Compatibility<\/td>\n<td>5 V TTL\/CMOS<\/td>\n<td>5 V TTL\/CMOS<\/td>\n<\/tr>\n<tr>\n<td>Output Drive<\/td>\n<td>24 mA<\/td>\n<td>24 mA<\/td>\n<\/tr>\n<tr>\n<td>Power-Up States<\/td>\n<td>Supported<\/td>\n<td>Supported<\/td>\n<\/tr>\n<tr>\n<td>Watchdog<\/td>\n<td>Supported<\/td>\n<td>Supported<\/td>\n<\/tr>\n<tr>\n<td>Best For<\/td>\n<td>Modular PXI Test Systems<\/td>\n<td>Desktop Computers with PCIe Slots<\/td>\n<\/tr>\n<\/table>\n<h3>PXIe\u20116509 vs Isolated Digital I\/O Modules<\/h3>\n<table>\n<tr>\n<th>\u0424\u0443\u043d\u043a\u0446\u0438\u044f<\/th>\n<th>PXIe\u20116509<\/th>\n<th>Isolated Digital I\/O Module<\/th>\n<\/tr>\n<tr>\n<td>Channel Count<\/td>\n<td><strong>96<\/strong><\/td>\n<td>Often Lower<\/td>\n<\/tr>\n<tr>\n<td>Logic Level<\/td>\n<td>5 V TTL\/CMOS<\/td>\n<td>Model Dependent, Often Industrial Voltage<\/td>\n<\/tr>\n<tr>\n<td>\u0418\u0437\u043e\u043b\u044f\u0446\u0438\u044f<\/td>\n<td>No<\/td>\n<td><strong>\u0414\u0430<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Output Drive<\/td>\n<td>24 mA Logic Output<\/td>\n<td>Model Dependent<\/td>\n<\/tr>\n<tr>\n<td>Best For<\/td>\n<td>High-Density Ground-Referenced Control<\/td>\n<td>Industrial Signals and Different Ground Potentials<\/td>\n<\/tr>\n<\/table>\n<p>\nChoose the PXIe\u20116509 for high-density 5 V TTL\/CMOS control. Choose an isolated digital I\/O module when the application involves higher industrial voltages, long field wiring or significant ground-potential differences.\n<\/p>\n<h3>Software and Driver Requirements<\/h3>\n<p>\nThe PXIe\u20116509 uses the <strong>NI\u2011DAQmx<\/strong> driver for digital input, digital output and device configuration.\n<\/p>\n<p>\nCompatible development environments can include:\n<\/p>\n<ul>\n<li>\u041b\u0430\u0431\u0412\u044c\u044e<\/li>\n<li>LabWindows\/CVI<\/li>\n<li>C and C++<\/li>\n<li>.NET applications<\/li>\n<li>Python with a compatible NI\u2011DAQmx interface<\/li>\n<li>NI TestStand sequences through supported code modules<\/li>\n<\/ul>\n<p>\nVerify NI\u2011DAQmx, operating-system and development-environment compatibility before installing or upgrading the system.\n<\/p>\n<h3>Recommended Related Products<\/h3>\n<table>\n<tr>\n<td width=\"220\"><strong>PCIe\u20116509<\/strong><\/td>\n<td>96-channel PCI Express digital I\/O device for compatible desktop computers.<\/td>\n<\/tr>\n<tr>\n<td><strong>USB\u20116509<\/strong><\/td>\n<td>96-channel USB digital I\/O device for portable and desktop test applications.<\/td>\n<\/tr>\n<tr>\n<td><strong>PXI\u20116509<\/strong><\/td>\n<td>Legacy PXI version of the 96-channel static digital I\/O module.<\/td>\n<\/tr>\n<tr>\n<td><strong>PXI\u20116515<\/strong><\/td>\n<td>Industrial digital I\/O module for applications requiring a different channel and electrical architecture.<\/td>\n<\/tr>\n<tr>\n<td><strong>PXI\u20116528<\/strong><\/td>\n<td>Isolated digital input and solid-state relay output module for industrial monitoring and control.<\/td>\n<\/tr>\n<tr>\n<td><a href=\"https:\/\/pxisource.com\/ru\/product-category\/%d0%bd%d0%b8\/pxi-%d1%81%d0%b8%d1%81%d1%82%d0%b5%d0%bc%d1%81\/%d0%bc%d0%be%d0%b4%d1%83%d0%bb%d0%b8-pxi\/\"><strong>NI PXI Modules<\/strong><\/a><\/td>\n<td>Modular instruments for digital I\/O, data acquisition, timing and automated test systems.<\/td>\n<\/tr>\n<\/table>\n<h3>Why Choose PXIe\u20116509?<\/h3>\n<ul>\n<li>96 bidirectional digital I\/O channels<\/li>\n<li>12 eight-bit digital ports<\/li>\n<li>Independent input or output configuration by line<\/li>\n<li>5 V TTL\/CMOS compatibility<\/li>\n<li>Up to 24 mA drive per channel<\/li>\n<li>Direct control of compatible solid-state relays<\/li>\n<li>Programmable power-up states<\/li>\n<li>Software-selectable pull-up and pull-down resistors<\/li>\n<li>Programmable digital input filtering<\/li>\n<li>Digital change detection<\/li>\n<li>Digital watchdog timer<\/li>\n<li>Configurable watchdog safe states<\/li>\n<li>Fused 5 V connector power output<\/li>\n<li>PXI Express interface<\/li>\n<li>NI\u2011DAQmx software support<\/li>\n<li>Suitable for fixture and relay control<\/li>\n<li>Suitable for switch and status monitoring<\/li>\n<li>Suitable for automated production test<\/li>\n<\/ul>\n<h3>Frequently Asked Questions<\/h3>\n<h4>What is the PXIe\u20116509?<\/h4>\n<p>\nThe PXIe\u20116509 is a 96-channel, 5 V TTL\/CMOS PXI Express digital I\/O module with 24 mA output drive, programmable power-up states, filtering and watchdog support.\n<\/p>\n<h4>What is the part number for the PXIe\u20116509?<\/h4>\n<p>\nThe standard National Instruments part number for the PXIe\u20116509 is <strong>787358\u201101<\/strong>.\n<\/p>\n<h4>How many digital channels does the PXIe\u20116509 provide?<\/h4>\n<p>\nThe module provides 96 bidirectional digital I\/O channels organized as 12 eight-bit ports.\n<\/p>\n<h4>Can each PXIe\u20116509 line be configured independently?<\/h4>\n<p>\nYes. Each line can be independently configured as a static digital input or output.\n<\/p>\n<h4>Which logic levels does the PXIe\u20116509 support?<\/h4>\n<p>\nThe module is designed for compatible 5 V TTL\/CMOS digital signals.\n<\/p>\n<h4>What is the maximum output current per channel?<\/h4>\n<p>\nEach output can provide up to 24 mA under the specified electrical and total-current limits.\n<\/p>\n<h4>Can the PXIe\u20116509 directly control relays?<\/h4>\n<p>\nIt can directly control many compatible solid-state relay inputs. Electromechanical relay coils normally require an external driver and flyback protection.\n<\/p>\n<h4>Does the PXIe\u20116509 support programmable power-up states?<\/h4>\n<p>\nYes. Output lines can be configured to start in predefined logic states when the device powers on or resets.\n<\/p>\n<h4>Does the PXIe\u20116509 have a watchdog timer?<\/h4>\n<p>\nYes. The watchdog can move configured output lines to predefined safe states if the controlling application stops communicating with the device.\n<\/p>\n<h4>Does the PXIe\u20116509 support digital filtering?<\/h4>\n<p>\nYes. Programmable input filters can reject glitches and debounce mechanical switches or relay contacts.\n<\/p>\n<h4>Does the PXIe\u20116509 support change detection?<\/h4>\n<p>\nYes. It can detect rising or falling transitions on selected digital input lines. The device has one shared change-detection resource.\n<\/p>\n<h4>Can the PXIe\u20116509 generate hardware-timed digital waveforms?<\/h4>\n<p>\nNo. Its digital input samples and output updates are software-timed. A high-speed digital instrument should be used for clocked waveform applications.\n<\/p>\n<h4>Does the PXIe\u20116509 provide isolation?<\/h4>\n<p>\nNo. The digital channels are single-ended and ground referenced. External isolation may be required for industrial signals or different ground potentials.\n<\/p>\n<h4>Does the PXIe\u20116509 require a PXI Express chassis?<\/h4>\n<p>\nYes. It must be installed in a compatible PXI Express chassis and controlled by an embedded controller or remote host connection.\n<\/p>\n<h4>Which driver does the PXIe\u20116509 use?<\/h4>\n<p>\nThe module uses the NI\u2011DAQmx driver.\n<\/p>\n<h4>What connector does the PXIe\u20116509 use?<\/h4>\n<p>\nIt uses a 100-pin female 0.050-series SCSI I\/O connector.\n<\/p>\n<h4>What should I check before purchasing the PXIe\u20116509?<\/h4>\n<p>\nVerify the required channel count, TTL\/CMOS voltage compatibility, output current, isolation requirements, timing requirements, PXI Express chassis, cable, terminal block and NI\u2011DAQmx compatibility.\n<\/p>\n<h3>\u0417\u0430\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435<\/h3>\n<p>\n\u0417\u0435\u043c\u043b\u044f <strong>PXIe\u20116509 96-Channel Digital I\/O Module<\/strong> provides high-density 5 V TTL\/CMOS control and monitoring for PXI Express systems. Its 24 mA outputs, programmable power-up states, pull resistors, digital filtering, change detection and watchdog safe states make it suitable for solid-state relay control, switch monitoring, test-fixture automation, DUT configuration and production functional testing.<\/p>","protected":false},"excerpt":{"rendered":"<p>\u0428\u0438\u043d\u043d\u044b\u0439 \u0441\u043e\u0435\u0434\u0438\u043d\u0438\u0442\u0435\u043b\u044c: PXI Express<br \/>\n\u0412\u044b\u0445\u043e\u0434\u043d\u043e\u0439 \u0442\u043e\u043a \u0446\u0438\u0444\u0440\u043e\u0432\u043e\u0433\u043e \u043a\u0430\u043d\u0430\u043b\u0430 \u043e\u0431\u0449\u0435\u0433\u043e \u043d\u0430\u0437\u043d\u0430\u0447\u0435\u043d\u0438\u044f: 24 \u043c\u0410<br \/>\n\u0426\u0438\u0444\u0440\u043e\u0432\u044b\u0435 \u0443\u0440\u043e\u0432\u043d\u0438 \u0432\u0432\u043e\u0434\u0430-\u0432\u044b\u0432\u043e\u0434\u0430: 5 \u0412<br \/>\n\u041a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u043a\u0430\u043d\u0430\u043b\u043e\u0432 \u0442\u043e\u043b\u044c\u043a\u043e \u0446\u0438\u0444\u0440\u043e\u0432\u043e\u0433\u043e \u0432\u0445\u043e\u0434\u0430: 0<br \/>\n\u041a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u043a\u0430\u043d\u0430\u043b\u043e\u0432 \u0442\u043e\u043b\u044c\u043a\u043e \u0446\u0438\u0444\u0440\u043e\u0432\u043e\u0433\u043e \u0432\u044b\u0432\u043e\u0434\u0430: 0<br \/>\n\u041a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u0434\u0432\u0443\u043d\u0430\u043f\u0440\u0430\u0432\u043b\u0435\u043d\u043d\u044b\u0445 \u0446\u0438\u0444\u0440\u043e\u0432\u044b\u0445 \u043a\u0430\u043d\u0430\u043b\u043e\u0432: 96<br \/>\n\u0414\u0438\u0430\u043f\u0430\u0437\u043e\u043d \u0432\u0445\u043e\u0434\u043d\u043e\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f: \u043e\u0442 0 \u0412 \u0434\u043e 5 \u0412<br \/>\n\u0414\u0438\u0430\u043f\u0430\u0437\u043e\u043d \u0432\u044b\u0445\u043e\u0434\u043d\u043e\u0433\u043e \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u044f: \u043e\u0442 0 \u0412 \u0434\u043e 5,5 \u0412<br \/>\n\u041c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u0430\u044f \u0442\u0430\u043a\u0442\u043e\u0432\u0430\u044f \u0447\u0430\u0441\u0442\u043e\u0442\u0430: \u2013<br \/>\n\u0422\u0438\u043f \u0441\u0438\u0433\u043d\u0430\u043b\u0438\u0437\u0430\u0446\u0438\u0438: \u041e\u0434\u043d\u043e\u043f\u043e\u043b\u044e\u0441\u043d\u044b\u0439<\/p>","protected":false},"featured_media":31806,"template":"","meta":{"_acf_changed":false},"product_brand":[18],"product_cat":[739],"product_tag":[],"class_list":["post-28999","product","type-product","status-publish","has-post-thumbnail","product_brand-national-instruments","product_cat-pxi-digital-input-output","first","instock","shipping-taxable","purchasable","product-type-simple"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.0 (Yoast SEO v28.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>NI PXIe-6509 PXI Digital I\/O Module 787358-01, In Stock | Project Pricing<\/title>\n<meta name=\"description\" content=\"PXIe\u20116509 is a 96-channel, 5 V TTL\/CMOS digital I\/O module with 24 mA drive, programmable power-up states, filtering and watchdogs.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/pxisource.com\/ru\/product\/pxie-6509\/\" \/>\n<meta property=\"og:locale\" content=\"ru_RU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"PXIe-6509\" \/>\n<meta property=\"og:description\" content=\"PXIe\u20116509 is a 96-channel, 5 V TTL\/CMOS digital I\/O module with 24 mA drive, programmable power-up states, filtering and watchdogs.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/pxisource.com\/ru\/product\/pxie-6509\/\" \/>\n<meta property=\"og:site_name\" content=\"PXI Source\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=61582573040385\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-27T13:42:08+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PXIe-6509.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"800\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u0426\u0435\u043d\u0430\" \/>\n\t<meta name=\"twitter:data1\" content=\"&#036;1,037.00\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c\" \/>\n\t<meta name=\"twitter:data2\" content=\"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-6509\\\/\",\"url\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-6509\\\/\",\"name\":\"NI PXIe-6509 PXI Digital I\\\/O Module 787358-01, In Stock | Project Pricing\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-6509\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-6509\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/PXIe-6509.webp\",\"datePublished\":\"2025-09-16T05:13:47+00:00\",\"dateModified\":\"2026-08-27T13:42:08+00:00\",\"description\":\"PXIe\u20116509 is a 96-channel, 5 V TTL\\\/CMOS digital I\\\/O module with 24 mA drive, programmable power-up states, filtering and watchdogs.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-6509\\\/#breadcrumb\"},\"inLanguage\":\"ru-RU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-6509\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-6509\\\/#primaryimage\",\"url\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/PXIe-6509.webp\",\"contentUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/PXIe-6509.webp\",\"width\":800,\"height\":800,\"caption\":\"PXIe-6509\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-6509\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/pxisource.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\\\/\\\/pxisource.com\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"PXIe-6509\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\",\"url\":\"https:\\\/\\\/pxisource.com\\\/\",\"name\":\"PXI Systems\",\"description\":\"NI PXI, PXIe Modular Test Instrument Supplier\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/pxisource.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ru-RU\"}]}<\/script>\n<meta property=\"product:brand\" content=\"National Instruments\" \/>\n<meta property=\"product:price:amount\" content=\"1037.00\" \/>\n<meta property=\"product:price:currency\" content=\"USD\" \/>\n<meta property=\"og:availability\" content=\"instock\" \/>\n<meta property=\"product:availability\" content=\"instock\" \/>\n<meta property=\"product:condition\" content=\"new\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"NI PXIe-6509 PXI Digital I\/O Module 787358-01, In Stock | Project Pricing","description":"PXIe\u20116509 is a 96-channel, 5 V TTL\/CMOS digital I\/O module with 24 mA drive, programmable power-up states, filtering and watchdogs.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/pxisource.com\/ru\/product\/pxie-6509\/","og_locale":"ru_RU","og_type":"article","og_title":"PXIe-6509","og_description":"PXIe\u20116509 is a 96-channel, 5 V TTL\/CMOS digital I\/O module with 24 mA drive, programmable power-up states, filtering and watchdogs.","og_url":"https:\/\/pxisource.com\/ru\/product\/pxie-6509\/","og_site_name":"PXI Source","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=61582573040385","article_modified_time":"2026-08-27T13:42:08+00:00","og_image":[{"width":800,"height":800,"url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PXIe-6509.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"\u0426\u0435\u043d\u0430":"&#36;1,037.00","\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c":"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/pxisource.com\/product\/pxie-6509\/","url":"https:\/\/pxisource.com\/product\/pxie-6509\/","name":"NI PXIe-6509 PXI Digital I\/O Module 787358-01, In Stock | Project Pricing","isPartOf":{"@id":"https:\/\/pxisource.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/pxisource.com\/product\/pxie-6509\/#primaryimage"},"image":{"@id":"https:\/\/pxisource.com\/product\/pxie-6509\/#primaryimage"},"thumbnailUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PXIe-6509.webp","datePublished":"2025-09-16T05:13:47+00:00","dateModified":"2026-08-27T13:42:08+00:00","description":"PXIe\u20116509 is a 96-channel, 5 V TTL\/CMOS digital I\/O module with 24 mA drive, programmable power-up states, filtering and watchdogs.","breadcrumb":{"@id":"https:\/\/pxisource.com\/product\/pxie-6509\/#breadcrumb"},"inLanguage":"ru-RU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/pxisource.com\/product\/pxie-6509\/"]}]},{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/pxisource.com\/product\/pxie-6509\/#primaryimage","url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PXIe-6509.webp","contentUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PXIe-6509.webp","width":800,"height":800,"caption":"PXIe-6509"},{"@type":"BreadcrumbList","@id":"https:\/\/pxisource.com\/product\/pxie-6509\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/pxisource.com\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/pxisource.com\/shop\/"},{"@type":"ListItem","position":3,"name":"PXIe-6509"}]},{"@type":"WebSite","@id":"https:\/\/pxisource.com\/#website","url":"https:\/\/pxisource.com\/","name":"\u0421\u0438\u0441\u0442\u0435\u043c\u044b PXI","description":"NI PXI, PXIe Modular Test Instrument Supplier","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/pxisource.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ru-RU"}]},"product_brand":"National Instruments","product_price_amount":"1037.00","product_price_currency":"USD","og_availability":"instock","product_availability":"instock","product_condition":"new"},"_links":{"self":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/28999","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":5,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/28999\/revisions"}],"predecessor-version":[{"id":35549,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/28999\/revisions\/35549"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media\/31806"}],"wp:attachment":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media?parent=28999"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_brand?post=28999"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_cat?post=28999"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_tag?post=28999"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}