{"id":28609,"date":"2025-09-04T14:49:37","date_gmt":"2025-09-04T06:49:37","guid":{"rendered":"https:\/\/pxisource.com\/?post_type=product&#038;p=28609"},"modified":"2026-09-07T15:11:18","modified_gmt":"2026-09-07T07:11:18","slug":"pxie-1085","status":"publish","type":"product","link":"https:\/\/pxisource.com\/ru\/product\/pxie-1085\/","title":{"rendered":"PXIe-1085"},"content":{"rendered":"<h3>PXIe-1085 18-Slot 24 GB\/s PXI Express Chassis<\/h3>\n<p>\u0417\u0435\u043c\u043b\u044f <strong>NI PXIe-1085<\/strong> is an 18-slot PXI Express chassis designed for high-performance automated test, data acquisition, RF measurement and electronic validation systems. Its standard 24 GB\/s configuration provides one system-controller slot, 16 hybrid peripheral slots and one PXI Express system timing slot.<\/p>\n<p>The high-bandwidth backplane allows several PXI Express instruments to transfer measurement data simultaneously. Its hybrid connector architecture also supports compatible conventional PXI modules, helping engineers combine existing instrumentation with newer high-speed PXI Express devices.<\/p>\n<p>The standard 24 GB\/s PXIe-1085 provides up to <strong>775 W of usable backplane power<\/strong>, 38.25 W maximum peripheral-slot dissipation, external 10 MHz reference input and output and a 0\u00b0C to 55\u00b0C operating-temperature range.<\/p>\n<h3>Key Features of the PXIe-1085<\/h3>\n<ul>\n<li>18-slot 3U PXI Express chassis<\/li>\n<li>One dedicated system-controller slot<\/li>\n<li>16 hybrid peripheral slots<\/li>\n<li>One PXI Express system timing slot<\/li>\n<li>Up to 24 GB\/s maximum system bandwidth<\/li>\n<li>775 W maximum usable power for the 24 GB\/s version<\/li>\n<li>791 W maximum usable power for the earlier 12 GB\/s version<\/li>\n<li>38.25 W maximum peripheral-slot dissipation<\/li>\n<li>140 W maximum system-controller-slot dissipation<\/li>\n<li>Three 169 CFM chassis cooling fans<\/li>\n<li>Auto and High fan-speed modes<\/li>\n<li>External 10 MHz reference input and output<\/li>\n<li>PXI star and PXI Express differential star triggering<\/li>\n<li>Remote inhibit and voltage-monitoring connection<\/li>\n<li>Front-panel power, fan and temperature indicators<\/li>\n<li>Universal 100 VAC to 240 VAC input<\/li>\n<li>Replaceable modular power-supply shuttle<\/li>\n<li>Compatible with benchtop and rack-mounted installations<\/li>\n<\/ul>\n<h2>PXIe-1085 Technical Specifications<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Product Model<\/th>\n<td>PXIe-1085<\/td>\n<\/tr>\n<tr>\n<th>Standard 24 GB\/s Part Number<\/th>\n<td>783588-01<\/td>\n<\/tr>\n<tr>\n<th>ITER Configuration Part Number<\/th>\n<td>860869-01<\/td>\n<\/tr>\n<tr>\n<th>Product Type<\/th>\n<td>High-bandwidth PXI Express chassis<\/td>\n<\/tr>\n<tr>\n<th>Chassis Format<\/th>\n<td>3U, 18-slot PXI Express chassis<\/td>\n<\/tr>\n<tr>\n<th>Total Physical Slots<\/th>\n<td>18<\/td>\n<\/tr>\n<tr>\n<th>System-Controller Slots<\/th>\n<td>1<\/td>\n<\/tr>\n<tr>\n<th>Hybrid Peripheral Slots<\/th>\n<td>16<\/td>\n<\/tr>\n<tr>\n<th>PXI Express System Timing Slots<\/th>\n<td>1<\/td>\n<\/tr>\n<tr>\n<th>Maximum System Bandwidth<\/th>\n<td>24 GB\/s for part number 783588-01<\/td>\n<\/tr>\n<tr>\n<th>Maximum Usable Power, 24 GB\/s Version<\/th>\n<td>775 W<\/td>\n<\/tr>\n<tr>\n<th>Maximum Usable Power, 12 GB\/s Version<\/th>\n<td>791 W<\/td>\n<\/tr>\n<tr>\n<th>Maximum Controller-Slot Dissipation<\/th>\n<td>140 W<\/td>\n<\/tr>\n<tr>\n<th>Maximum Peripheral-Slot Dissipation<\/th>\n<td>38.25 W<\/td>\n<\/tr>\n<tr>\n<th>Power-Supply Type<\/th>\n<td>AC<\/td>\n<\/tr>\n<tr>\n<th>Redundant Hardware<\/th>\n<td>No<\/td>\n<\/tr>\n<tr>\n<th>Rated AC Input<\/th>\n<td>100 VAC to 240 VAC, 12 A to 6 A<\/td>\n<\/tr>\n<tr>\n<th>AC Operating Voltage Range<\/th>\n<td>90 VAC to 264 VAC<\/td>\n<\/tr>\n<tr>\n<th>Nominal Input Frequency<\/th>\n<td>50\/60 Hz<\/td>\n<\/tr>\n<tr>\n<th>Operating Frequency Range<\/th>\n<td>47 Hz to 63 Hz<\/td>\n<\/tr>\n<tr>\n<th>Input Overcurrent Protection<\/th>\n<td>15 A push-reset circuit breaker<\/td>\n<\/tr>\n<tr>\n<th>Typical Power-Supply Efficiency<\/th>\n<td>70%<\/td>\n<\/tr>\n<tr>\n<th>Maximum +3.3 V Current<\/th>\n<td>60 A<\/td>\n<\/tr>\n<tr>\n<th>Maximum +5 V Current, 24 GB\/s Version<\/th>\n<td>49 A<\/td>\n<\/tr>\n<tr>\n<th>Maximum +12 V Current<\/th>\n<td>62 A<\/td>\n<\/tr>\n<tr>\n<th>Maximum \u221212 V Current<\/th>\n<td>4 A<\/td>\n<\/tr>\n<tr>\n<th>Maximum +5 V Auxiliary Current<\/th>\n<td>2 A<\/td>\n<\/tr>\n<tr>\n<th>Power-Supply Replacement Time<\/th>\n<td>Less than five minutes<\/td>\n<\/tr>\n<tr>\n<th>Module Cooling System<\/th>\n<td>Forced-air positive-pressurization cooling<\/td>\n<\/tr>\n<tr>\n<th>Chassis Cooling Fans<\/th>\n<td>Three 169 CFM fans<\/td>\n<\/tr>\n<tr>\n<th>Fan-Speed Modes<\/th>\n<td>Auto and High<\/td>\n<\/tr>\n<tr>\n<th>Module Airflow Direction<\/th>\n<td>Bottom to top<\/td>\n<\/tr>\n<tr>\n<th>Module Air Intake<\/th>\n<td>Bottom rear of chassis<\/td>\n<\/tr>\n<tr>\n<th>Module Air Exhaust<\/th>\n<td>Top and both sides of chassis<\/td>\n<\/tr>\n<tr>\n<th>System Timing Slot<\/th>\n<td>\u0414\u0430<\/td>\n<\/tr>\n<tr>\n<th>External Clocking<\/th>\n<td>\u0414\u0430<\/td>\n<\/tr>\n<tr>\n<th>Integrated External Trigger Access<\/th>\n<td>No<\/td>\n<\/tr>\n<tr>\n<th>Onboard Clock Type<\/th>\n<td>VCXO<\/td>\n<\/tr>\n<tr>\n<th>PXI_CLK10 Accuracy<\/th>\n<td>\u00b125 ppm maximum<\/td>\n<\/tr>\n<tr>\n<th>PXI_CLK10 Slot-to-Slot Skew<\/th>\n<td>500 ps maximum<\/td>\n<\/tr>\n<tr>\n<th>PXIe_CLK100 Accuracy<\/th>\n<td>\u00b125 ppm maximum<\/td>\n<\/tr>\n<tr>\n<th>PXIe_CLK100 Slot-to-Slot Skew<\/th>\n<td>100 ps maximum<\/td>\n<\/tr>\n<tr>\n<th>PXI Star Trigger Slot-to-Slot Skew<\/th>\n<td>250 ps maximum<\/td>\n<\/tr>\n<tr>\n<th>Differential Star Trigger Slot-to-Slot Skew<\/th>\n<td>150 ps maximum<\/td>\n<\/tr>\n<tr>\n<th>Differential Trigger Skew<\/th>\n<td>25 ps maximum<\/td>\n<\/tr>\n<tr>\n<th>External Reference Input<\/th>\n<td>10 MHz \u00b1100 ppm through front-panel SMA<\/td>\n<\/tr>\n<tr>\n<th>External Reference Output<\/th>\n<td>10 MHz through front-panel SMA<\/td>\n<\/tr>\n<tr>\n<th>Remote Power Control<\/th>\n<td>Rear-panel inhibit and voltage-monitoring connector<\/td>\n<\/tr>\n<tr>\n<th>Chassis Network Monitoring<\/th>\n<td>Rear-panel Ethernet connection<\/td>\n<\/tr>\n<tr>\n<th>Operating Temperature<\/th>\n<td>0\u00b0C to 55\u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Operating Humidity<\/th>\n<td>10% to 90%, noncondensing<\/td>\n<\/tr>\n<tr>\n<th>Storage Temperature<\/th>\n<td>\u221240\u00b0C to 71\u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Storage Humidity<\/th>\n<td>5% to 95%, noncondensing<\/td>\n<\/tr>\n<tr>\n<th>Maximum Operating Altitude<\/th>\n<td>2,000 m at 25\u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Operational Shock<\/th>\n<td>30 g peak, half-sine, 11 ms pulse<\/td>\n<\/tr>\n<tr>\n<th>Operational Random Vibration<\/th>\n<td>5 Hz to 500 Hz, 0.3 grms<\/td>\n<\/tr>\n<tr>\n<th>Auto-Fan Sound Pressure<\/th>\n<td>51.2 dBA at up to approximately 30\u00b0C ambient<\/td>\n<\/tr>\n<tr>\n<th>High-Fan Sound Pressure<\/th>\n<td>64.1 dBA<\/td>\n<\/tr>\n<tr>\n<th>Dimensions<\/th>\n<td>177.1 \u00d7 464.8 \u00d7 492.3 mm<\/td>\n<\/tr>\n<tr>\n<th>Weight<\/th>\n<td>18.28 kg<\/td>\n<\/tr>\n<tr>\n<th>Intended Environment<\/th>\n<td>Indoor use<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>PXIe-1085 Part Number and Accessories<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Item<\/th>\n<th>Part Number<\/th>\n<th>\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435<\/th>\n<\/tr>\n<tr>\n<td>PXIe-1085<\/td>\n<td>783588-01<\/td>\n<td>Standard 18-slot PXI Express chassis with 24 GB\/s system bandwidth<\/td>\n<\/tr>\n<tr>\n<td>PXIe-1085 ITER Version<\/td>\n<td>860869-01<\/td>\n<td>Special ITER configuration; confirm backplane and project requirements before ordering<\/td>\n<\/tr>\n<tr>\n<td>Replacement Power Supply<\/td>\n<td>781719-01<\/td>\n<td>Replacement power-supply shuttle for the PXIe-1085<\/td>\n<\/tr>\n<tr>\n<td>U.S. IEC Power Cord<\/td>\n<td>763830-01<\/td>\n<td>125 VAC, 15 A power cord<\/td>\n<\/tr>\n<tr>\n<td>European IEC Power Cord<\/td>\n<td>763067-01<\/td>\n<td>240 V, 10 A right-angle power cord<\/td>\n<\/tr>\n<tr>\n<td>China IEC Power Cord<\/td>\n<td>784686-01<\/td>\n<td>250 V, 10 A power cord<\/td>\n<\/tr>\n<tr>\n<td>Korea IEC Power Cord<\/td>\n<td>784685-01<\/td>\n<td>240 V, 10 A right-angle power cord<\/td>\n<\/tr>\n<tr>\n<td>Brazil IEC Power Cord<\/td>\n<td>785626-01<\/td>\n<td>250 V, 10 A power cord<\/td>\n<\/tr>\n<tr>\n<td>Japan IEC Power Cord<\/td>\n<td>786377-01<\/td>\n<td>125 VAC, 12 A power cord<\/td>\n<\/tr>\n<tr>\n<td>Taiwan IEC Power Cord<\/td>\n<td>787642-01<\/td>\n<td>125 VAC, 15 A power cord<\/td>\n<\/tr>\n<tr>\n<td>India IEC Power Cord<\/td>\n<td>763072-01<\/td>\n<td>250 V, 10 A power cord<\/td>\n<\/tr>\n<tr>\n<td>Single-Slot Filler Panels<\/td>\n<td>Included<\/td>\n<td>Seven single-slot PXI filler panels<\/td>\n<\/tr>\n<tr>\n<td>Double-Slot Filler Panel<\/td>\n<td>Included<\/td>\n<td>One double-slot PXI filler panel<\/td>\n<\/tr>\n<tr>\n<td>Quadruple-Slot Filler Panels<\/td>\n<td>Included<\/td>\n<td>Two quadruple-slot PXI filler panels<\/td>\n<\/tr>\n<tr>\n<td>Mini-COMBICON Connector Plug<\/td>\n<td>Included<\/td>\n<td>Connector for supported remote inhibit and monitoring functions<\/td>\n<\/tr>\n<tr>\n<td>Front Rack-Mount Kit<\/td>\n<td>Configuration dependent<\/td>\n<td>Optional front rack-mounting hardware<\/td>\n<\/tr>\n<tr>\n<td>Rear Rack-Mount Kit<\/td>\n<td>Configuration dependent<\/td>\n<td>Optional rear support for compatible instrument racks<\/td>\n<\/tr>\n<tr>\n<td>Chassis Fan Replacement Assembly<\/td>\n<td>Configuration dependent<\/td>\n<td>Replacement cooling-fan hardware for the PXIe-1085<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The standard chassis package includes seven single-slot filler panels, one double-slot filler panel, two quadruple-slot filler panels, a Mini-COMBICON connector plug, a 1\/2-inch screw and safety documentation.<\/p>\n<p>The model has been supplied in more than one configuration. Use the complete part number when requesting a quotation, especially when replacing an existing 12 GB\/s or ITER chassis with the current 24 GB\/s version.<\/p>\n<h3>18-Slot PXI Express Architecture<\/h3>\n<p>The PXIe-1085 provides one system-controller position and 17 peripheral positions. Sixteen peripheral slots use hybrid connectors, while one position is dedicated to PXI Express system timing.<\/p>\n<p>This capacity allows engineers to combine multiple measurement and control functions in one chassis. A configuration can include digitizers, waveform generators, DMMs, programmable power supplies, switching modules, FPGA devices and communication interfaces.<\/p>\n<p>The controller position includes three adjacent system-controller expansion slots. A multi-slot embedded controller reduces the remaining space available for peripheral modules.<\/p>\n<h3>Sixteen Hybrid Peripheral Slots<\/h3>\n<p>The hybrid connector in each general-purpose peripheral position supports compatible PXI Express instruments and hybrid-compatible conventional PXI modules.<\/p>\n<p>This all-hybrid architecture is useful when upgrading an existing PXI test station. Engineers can retain supported legacy modules while adding newer high-speed instruments where additional bandwidth is needed.<\/p>\n<p>Verify every module\u2019s connector, voltage signaling, driver, operating-system, power and cooling requirements before installation. A conventional PXI module without a hybrid-compatible connector cannot be forced into the chassis.<\/p>\n<h3>Dedicated System Timing Slot<\/h3>\n<p>The PXIe-1085 includes one dedicated PXI Express system timing slot. Compatible timing and synchronization modules installed in this position can access specialized differential star triggers and reference-clock routing.<\/p>\n<p>This capability supports multichannel digitizers, synchronized signal generation, phase-related measurements and systems requiring coordinated operation across several instruments.<\/p>\n<p>Multi-chassis systems can use compatible timing hardware to share clocks and triggers. Cable delay, module delay and route configuration must be included in the synchronization plan.<\/p>\n<h3>24 GB\/s High-Bandwidth Backplane<\/h3>\n<p>Part number 783588-01 provides up to 24 GB\/s of maximum aggregate system bandwidth. This is particularly valuable when several PXI Express instruments transfer large data streams at the same time.<\/p>\n<p>The chassis bandwidth is shared according to the backplane topology, controller links and installed modules. It does not mean that every slot independently supports 24 GB\/s.<\/p>\n<p>Actual throughput also depends on the embedded or remote controller, instrument PCI Express interfaces, storage system, DMA settings and software processing.<\/p>\n<h3>\u0412\u044b\u0441\u043e\u043a\u043e\u0441\u043a\u043e\u0440\u043e\u0441\u0442\u043d\u0430\u044f \u043f\u043e\u0442\u043e\u043a\u043e\u0432\u0430\u044f \u043f\u0435\u0440\u0435\u0434\u0430\u0447\u0430 \u0434\u0430\u043d\u043d\u044b\u0445<\/h3>\n<p>High-speed digitizers, RF analyzers and FPGA modules can generate substantial volumes of measurement data. The 24 GB\/s backplane helps reduce congestion when multiple devices perform sustained acquisition.<\/p>\n<p>Before installation, calculate the payload data rate for every streaming instrument. Include protocol overhead, simultaneous acquisitions, storage write speed and real-time analysis requirements.<\/p>\n<p>Modules with lower command-and-status traffic, such as switching or serial interfaces, usually place less demand on backplane bandwidth.<\/p>\n<h3>775 W Usable Power<\/h3>\n<p>The standard 24 GB\/s PXIe-1085 provides up to 775 W of usable backplane power. Earlier 12 GB\/s configurations provide up to 791 W.<\/p>\n<p>The 24 GB\/s version supports maximum rail currents of 60 A at +3.3 V, 49 A at +5 V, 62 A at +12 V, 4 A at \u221212 V and 2 A at +5 V auxiliary.<\/p>\n<p>Power budgeting must consider the requirements of each voltage rail. A configuration can remain below 775 W overall while exceeding an individual rail or slot limit.<\/p>\n<h3>38.25 W Peripheral-Slot Limit<\/h3>\n<p>Each peripheral position supports a maximum module dissipation of 38.25 W. The controller position supports up to 140 W.<\/p>\n<p>This limit is important when selecting newer PXI Express instruments. Some current high-speed digitizers, RF transceivers and FPGA modules require more than 38 W of cooling.<\/p>\n<p>For modules exceeding this limit, select a high-power chassis such as the <a href=\"https:\/\/pxisource.com\/ru\/product\/%d0%bf%d1%8c%d0%b5-1095\/\">PXIe-1095<\/a>, which supports substantially greater per-slot cooling.<\/p>\n<h3>Replaceable Power-Supply Shuttle<\/h3>\n<p>The PXIe-1085 uses a removable power-supply shuttle. NI specifies a replacement time of less than five minutes, helping maintenance personnel restore a system without replacing the complete chassis.<\/p>\n<p>The compatible replacement supply is part number 781719-01. Disconnect AC power and follow the official replacement instructions before servicing the supply.<\/p>\n<p>The PXIe-1085 does not provide redundant hardware. Removing or replacing its supply interrupts system operation.<\/p>\n<h3>Power-Supply Protection<\/h3>\n<p>The chassis outputs include protection against short circuits and overload conditions with automatic recovery. The 3.3 V and 5 V rails also include overvoltage clamping.<\/p>\n<p>Input overcurrent protection is provided by a 15 A push-reset circuit breaker on the rear panel.<\/p>\n<p>Protection features reduce the likelihood of damage but do not replace correct module installation, power budgeting or external circuit protection.<\/p>\n<h3>Three-Fan Cooling System<\/h3>\n<p>Three 169 CFM fans provide positive-pressure forced-air cooling for installed modules. The fan-speed selector supports Auto and High modes.<\/p>\n<p>Cooling air enters through the lower rear of the chassis, moves upward through the instrument slots and exits through the top and both sides.<\/p>\n<p>The power supply uses two integrated fans with air moving from the right side toward the left side of the chassis.<\/p>\n<h3>Maintaining Correct Airflow<\/h3>\n<p>Every unused position should be covered with a filler panel. Open slots allow cooling air to bypass active instruments and can create uneven module temperatures.<\/p>\n<p>Do not block the bottom-rear intake, top exhaust or side vents. Rack shelves, cable trays and nearby instruments must be arranged to preserve the intended airflow.<\/p>\n<p>Use High fan mode when the ambient environment, rack configuration or installed module load requires maximum cooling.<\/p>\n<h3>Chassis Status Indicators<\/h3>\n<p>Front-panel indicators provide information about temperature, cooling-fan operation and power status. These indicators help operators identify problems during installation and maintenance.<\/p>\n<p>A warning should be investigated promptly. Continuing to operate after a fan or temperature fault can reduce hardware reliability or cause an unexpected shutdown.<\/p>\n<p>Preventive maintenance should include inspection of air intakes, filler panels, fan operation and accumulated dust.<\/p>\n<h3>External 10 MHz Reference Input<\/h3>\n<p>A front-panel SMA input accepts an external 10 MHz reference with a frequency tolerance of \u00b1100 ppm. The supported input amplitude is 200 mVpp to 5 Vpp for a sine or square waveform.<\/p>\n<p>The connector has a 50 \u03a9 nominal input impedance. Use correctly terminated coaxial cabling to reduce reflections and clock-distribution errors.<\/p>\n<p>The system timing slot can also accept a compatible PXI_CLK10_IN signal from an installed timing module.<\/p>\n<h3>External 10 MHz Reference Output<\/h3>\n<p>The front-panel 10 MHz REF OUT SMA provides the chassis reference to compatible external equipment or another measurement system.<\/p>\n<p>The output supplies approximately 1 Vpp into 50 \u03a9 or 2 Vpp when unloaded, with 50 \u03a9 nominal output impedance.<\/p>\n<p>When distributing the reference to multiple destinations, use suitable clock-distribution hardware rather than unsupported passive loading.<\/p>\n<h3>PXI Express Timing Resources<\/h3>\n<p>The backplane distributes PXI_CLK10, PXIe_CLK100 and PXIe_SYNC100. PXI_CLK10 provides \u00b125 ppm accuracy and a maximum slot-to-slot skew of 500 ps.<\/p>\n<p>PXIe_CLK100 also provides \u00b125 ppm accuracy, with a maximum slot-to-slot skew of 100 ps. PXI star triggering supports 250 ps maximum slot-to-slot skew.<\/p>\n<p>PXI Express differential star resources support a maximum slot-to-slot skew of 150 ps and maximum differential skew of 25 ps.<\/p>\n<h3>Remote Inhibit and Voltage Monitoring<\/h3>\n<p>A rear-panel eight-pin connector supports remote inhibit, fault indication and voltage-monitoring functions. The inhibit mode selector determines how the chassis responds to the external control signal.<\/p>\n<p>This interface can integrate the PXIe-1085 into a centralized rack power sequence or system safety architecture.<\/p>\n<p>Remote-control wiring must follow the user manual. The AC power cord remains the primary means of completely disconnecting the chassis from power.<\/p>\n<h3>Ethernet Chassis Monitoring<\/h3>\n<p>A rear-panel Ethernet connection supports compatible chassis monitoring and configuration functions. System administrators can use the applicable NI utilities to review chassis information.<\/p>\n<p>This connection is intended for chassis management rather than serving as the embedded controller\u2019s primary measurement-data network interface.<\/p>\n<h3>Embedded and Remote Control<\/h3>\n<p>A compatible embedded PXI Express controller can be installed to create a self-contained automated test system. This arrangement keeps processing, storage and instrumentation in one chassis.<\/p>\n<p>A compatible remote-control interface allows an external workstation or server to manage the installed instruments. This provides greater freedom to select computing and storage hardware.<\/p>\n<p>The controller must support the backplane link configuration required to take advantage of the chassis\u2019s maximum bandwidth.<\/p>\n<h3>Benchtop and Rack Installation<\/h3>\n<p>The chassis measures approximately 177.1 mm high, 464.8 mm wide and 492.3 mm deep. It weighs approximately 18.28 kg before controllers, modules and cables are installed.<\/p>\n<p>Optional front and rear rack-mount kits allow the chassis to be installed in compatible cabinets. Its symmetrical mounting holes support different equipment orientations.<\/p>\n<p>Use appropriate rack support and safe lifting practices. Heavy signal cables should be supported independently instead of placing excessive force on module front panels.<\/p>\n<h2>PXIe-1085 Applications<\/h2>\n<ul>\n<li>High-throughput automated test equipment<\/li>\n<li>High-speed multichannel data acquisition<\/li>\n<li>RF and wireless-device testing<\/li>\n<li>Semiconductor characterization<\/li>\n<li>Mixed-signal electronic validation<\/li>\n<li>\u0418\u0441\u043f\u044b\u0442\u0430\u043d\u0438\u044f \u0432 \u0430\u044d\u0440\u043e\u043a\u043e\u0441\u043c\u0438\u0447\u0435\u0441\u043a\u043e\u0439 \u0438 \u043e\u0431\u043e\u0440\u043e\u043d\u043d\u043e\u0439 \u043f\u0440\u043e\u043c\u044b\u0448\u043b\u0435\u043d\u043d\u043e\u0441\u0442\u0438<\/li>\n<li>Automotive ECU and HIL validation<\/li>\n<li>High-speed digitizer systems<\/li>\n<li>\u041e\u0431\u0440\u0430\u0431\u043e\u0442\u043a\u0430 \u0441\u0438\u0433\u043d\u0430\u043b\u043e\u0432 \u043d\u0430 \u043e\u0441\u043d\u043e\u0432\u0435 \u041f\u041b\u0418\u0421<\/li>\n<li>Production functional testing<\/li>\n<li>Research laboratory automation<\/li>\n<li>Synchronized stimulus-and-response testing<\/li>\n<\/ul>\n<h3>High-Throughput Automated Testing<\/h3>\n<p>The 24 GB\/s backplane makes the PXIe-1085 suitable for test systems that must acquire, process and store data from several instruments concurrently.<\/p>\n<p>TestStand, LabVIEW or another supported environment can coordinate measurement, switching, stimulus and result-management operations.<\/p>\n<h3>High-Speed Data Acquisition<\/h3>\n<p>Multiple digitizers and DAQ modules can share the chassis for synchronized multichannel acquisition. The system timing slot supports compatible clock and trigger-distribution hardware.<\/p>\n<p>Overall performance depends on controller bandwidth, module placement, sample format, processing load and storage speed.<\/p>\n<h3>RF and Wireless Testing<\/h3>\n<p>Vector signal analyzers, signal generators, RF switches and high-speed digitizers can be combined for automated wireless-device and RF component testing.<\/p>\n<p>The high-bandwidth backplane is useful when RF instruments stream wideband I\/Q data to the controller for analysis.<\/p>\n<h3>\u0425\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0430 \u043f\u043e\u043b\u0443\u043f\u0440\u043e\u0432\u043e\u0434\u043d\u0438\u043a\u043e\u0432<\/h3>\n<p>Semiconductor systems can combine source measure units, digital instruments, switches, waveform devices and digitizers in one synchronized platform.<\/p>\n<p>The 16 hybrid slots also support selected legacy PXI instruments used in established characterization systems.<\/p>\n<h3>Aerospace and Defense Validation<\/h3>\n<p>The chassis can host avionics interfaces, digitizers, arbitrary waveform generators, timing modules and switching hardware for aerospace subsystem validation.<\/p>\n<p>External reference-clock connections allow the PXI system to coordinate with compatible laboratory timing equipment.<\/p>\n<h3>Automotive and HIL Testing<\/h3>\n<p>Real-time controllers, FPGA modules, vehicle communication interfaces, fault-insertion switches and analog I\/O can be combined for ECU validation.<\/p>\n<p>Verify the controller\u2019s deterministic processing performance and the 38.25 W per-slot restriction when selecting modules for an HIL system.<\/p>\n<h3>Research and Laboratory Automation<\/h3>\n<p>The large hybrid backplane provides a reconfigurable platform for research teams using different instrument combinations across several projects.<\/p>\n<p>Modules can be added or replaced as requirements change without discarding the entire test architecture.<\/p>\n<h2>PXIe-1085 Installation Workflow<\/h2>\n<h4>Step 1: Verify the Complete Part Number<\/h4>\n<p>Confirm whether the chassis is standard part number 783588-01, an earlier 12 GB\/s configuration or special ITER part number 860869-01.<\/p>\n<p>Do not assume every chassis marked PXIe-1085 has identical bandwidth and power specifications.<\/p>\n<h4>Step 2: Prepare a Slot Map<\/h4>\n<p>List the controller, timing module and peripheral instruments. Record module width, connector type, bandwidth, power consumption and cooling requirement.<\/p>\n<h5>Reserve the System Timing Position<\/h5>\n<p>Install the compatible timing module in the dedicated PXI Express system timing slot when differential star resources are required.<\/p>\n<h5>Account for Controller Width<\/h5>\n<p>A multi-slot embedded controller occupies the system slot and adjacent expansion positions, reducing the number of usable peripheral locations.<\/p>\n<h4>Step 3: Calculate Power Requirements<\/h4>\n<p>Confirm that the 24 GB\/s configuration remains within the 775 W total limit and the current capacity of every voltage rail.<\/p>\n<p>Verify that no peripheral module dissipates more than 38.25 W.<\/p>\n<h4>Step 4: Prepare the Installation Area<\/h4>\n<p>Place the chassis on a stable bench or install it using compatible front and rear rack-mount hardware.<\/p>\n<p>Preserve the bottom-rear intake, top exhaust and side airflow paths. Prevent neighboring instruments from exhausting hot air directly into the chassis.<\/p>\n<h4>Step 5: Connect Protective Ground<\/h4>\n<p>Connect an approved regional IEC power cord to a properly grounded outlet. Keep the power connector accessible because removing the cord completely disconnects AC power.<\/p>\n<h4>Step 6: Power Off Before Installing Modules<\/h4>\n<p>Switch off and disconnect the chassis. Follow antistatic precautions when handling the controller, timing module and peripheral instruments.<\/p>\n<h4>Step 7: Install the System Controller<\/h4>\n<p>Insert the embedded controller or remote-control interface into the system slot. Seat the connectors fully and tighten the retaining screws.<\/p>\n<h4>Step 8: Install the Timing Module<\/h4>\n<p>Install the timing and synchronization module in the dedicated system timing slot when required by the application.<\/p>\n<h4>Step 9: Install Peripheral Modules<\/h4>\n<p>Place high-throughput instruments according to the chassis bandwidth topology. Install lower-bandwidth switching and communication modules in the remaining compatible positions.<\/p>\n<h4>Step 10: Install Filler Panels<\/h4>\n<p>Cover every unused position with the correct filler panel. This maintains electromagnetic compatibility and prevents cooling air from bypassing active modules.<\/p>\n<h4>Step 11: Connect Instruments and Fixtures<\/h4>\n<p>Connect signal cables, terminal blocks, external timing references and test fixtures. Support heavy cables and maintain the required bend radius.<\/p>\n<h4>Step 12: Power On and Check Chassis Status<\/h4>\n<p>Turn on the chassis and verify that its power, temperature and fan indicators show normal operation.<\/p>\n<h4>Step 13: Detect the Hardware<\/h4>\n<p>Use NI Measurement &amp; Automation Explorer to identify the chassis and installed modules. Install compatible drivers and run available self-tests.<\/p>\n<h4>Step 14: Validate System Performance<\/h4>\n<p>Run representative simultaneous acquisitions and confirm backplane throughput, storage performance, synchronization and thermal stability before production use.<\/p>\n<h2>PXIe-1085 Troubleshooting<\/h2>\n<h4>The PXIe-1085 Does Not Power On<\/h4>\n<p>Confirm that the power cord and outlet are functional and within the 90 VAC to 264 VAC operating range. Check the rear push-reset circuit breaker and front-panel power switch.<\/p>\n<p>If remote inhibit is configured, inspect the rear connector and inhibit-mode selection.<\/p>\n<h4>The Circuit Breaker Trips Repeatedly<\/h4>\n<p>Disconnect the chassis and remove peripheral loads before resetting the breaker. Repeated tripping may indicate an overload, defective module or power-supply fault.<\/p>\n<p>Do not repeatedly reset the circuit breaker without identifying the cause.<\/p>\n<h4>An Installed Module Is Not Detected<\/h4>\n<p>Power down the chassis and reseat the module. Confirm hybrid connector compatibility and install the correct device driver.<\/p>\n<p>Use NI MAX to rescan the system. Testing the module in another supported slot can help isolate a slot, driver or module problem.<\/p>\n<h4>Data Throughput Is Lower Than Expected<\/h4>\n<p>Confirm that the chassis is the 24 GB\/s part number and that the controller supports the required link configuration.<\/p>\n<p>Check module placement, DMA settings, CPU usage, storage speed and simultaneous transfers. The 24 GB\/s figure is the aggregate chassis maximum.<\/p>\n<h4>The Chassis Reports a Fan Fault<\/h4>\n<p>Inspect the corresponding fan module and check for blocked airflow or foreign material. Replace a defective fan using the approved PXIe-1085 fan service procedure.<\/p>\n<p>Monitor temperature and reduce system load until normal cooling is restored.<\/p>\n<h4>The Chassis Reports Excessive Temperature<\/h4>\n<p>Check that filler panels cover every unused position and that the bottom-rear intake, top exhaust and side vents remain open.<\/p>\n<p>Inspect fan operation, ambient temperature and rack exhaust. Select High fan mode when additional cooling is required.<\/p>\n<h4>External Clock Synchronization Does Not Work<\/h4>\n<p>Confirm that the reference source is 10 MHz within \u00b1100 ppm and that its amplitude falls between 200 mVpp and 5 Vpp.<\/p>\n<p>Use 50 \u03a9 cabling and verify connector direction, termination and timing-module configuration.<\/p>\n<h4>Remote Power Control Does Not Work<\/h4>\n<p>Check the eight-pin rear connector, inhibit-mode switch and signal voltage levels. Verify that the external control circuit shares the required reference.<\/p>\n<h4>The Power Supply Has Failed<\/h4>\n<p>Turn off the chassis and disconnect AC power before replacing the supply. The PXIe-1085 does not have redundant power supplies and cannot continue operating during replacement.<\/p>\n<p>Use replacement power supply 781719-01 and follow the official service instructions.<\/p>\n<h4>The Fans Are Louder Than Expected<\/h4>\n<p>High fan mode increases sound pressure to approximately 64.1 dBA. Auto mode is quieter under supported lower-temperature conditions.<\/p>\n<p>Do not reduce fan speed when the ambient environment or module load requires maximum cooling.<\/p>\n<h4>A Legacy PXI Module Does Not Fit<\/h4>\n<p>Not every conventional PXI module supports hybrid connectors. Check the module documentation and never force an incompatible backplane connector.<\/p>\n<h2>PXIe-1085 Comparison<\/h2>\n<table>\n<tbody>\n<tr>\n<th>\u0424\u0443\u043d\u043a\u0446\u0438\u044f<\/th>\n<th>PXIe-1085<\/th>\n<th>PXIe-1084<\/th>\n<th>PXIe-1086<\/th>\n<th>PXIe-1095<\/th>\n<\/tr>\n<tr>\n<td>\u041e\u0431\u0449\u0435\u0435 \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u0441\u043b\u043e\u0442\u043e\u0432<\/td>\n<td>18<\/td>\n<td>18<\/td>\n<td>18<\/td>\n<td>18<\/td>\n<\/tr>\n<tr>\n<td>Hybrid Peripheral Slots<\/td>\n<td>16<\/td>\n<td>17<\/td>\n<td>16<\/td>\n<td>5<\/td>\n<\/tr>\n<tr>\n<td>System Timing Slot<\/td>\n<td>\u0414\u0430<\/td>\n<td>No on standard configuration<\/td>\n<td>\u0414\u0430<\/td>\n<td>\u0414\u0430<\/td>\n<\/tr>\n<tr>\n<td>Maximum System Bandwidth<\/td>\n<td>24 \u0413\u0411\/\u0441<\/td>\n<td>4 GB\/s<\/td>\n<td>12 GB\/s<\/td>\n<td>24 \u0413\u0411\/\u0441<\/td>\n<\/tr>\n<tr>\n<td>Maximum Slot Cooling<\/td>\n<td>38 W class<\/td>\n<td>58 W<\/td>\n<td>38 W class<\/td>\n<td>82 \u0412\u0442<\/td>\n<\/tr>\n<tr>\n<td>Redundant Hardware<\/td>\n<td>No<\/td>\n<td>No<\/td>\n<td>\u0414\u0430<\/td>\n<td>\u0414\u0430<\/td>\n<\/tr>\n<tr>\n<td>Primary Advantage<\/td>\n<td>High bandwidth with extensive hybrid-slot compatibility<\/td>\n<td>Higher slot cooling at lower system bandwidth<\/td>\n<td>High-availability redundant architecture<\/td>\n<td>High bandwidth, high power and 82 W slot cooling<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>PXIe-1085 vs PXIe-1084<\/h3>\n<p>\u0417\u0435\u043c\u043b\u044f <a href=\"https:\/\/pxisource.com\/ru\/product\/%d0%bf%d0%b8%d0%ba%d1%81%d0%b8-1084\/\">PXIe-1084<\/a> provides more hybrid positions and up to 58 W of cooling per slot, but its standard system bandwidth is lower.<\/p>\n<p>Choose the PXIe-1085 for high-throughput acquisition. Choose the PXIe-1084 when higher per-slot cooling and maximum hybrid-slot capacity are more important than backplane bandwidth.<\/p>\n<h3>PXIe-1085 vs PXIe-1086<\/h3>\n<p>\u0417\u0435\u043c\u043b\u044f <a href=\"https:\/\/pxisource.com\/ru\/product\/pxie-1086\/\">PXIe-1086<\/a> provides 12 GB\/s bandwidth and redundant hot-swappable power and cooling hardware.<\/p>\n<p>The PXIe-1085 offers higher 24 GB\/s bandwidth but does not provide redundant hardware. Select between them according to whether throughput or service availability is the primary requirement.<\/p>\n<h3>PXIe-1085 vs PXIe-1095<\/h3>\n<p>The PXIe-1095 provides the same 24 GB\/s headline bandwidth with up to 82 W of power and cooling per slot. It also supports hot-swappable power supplies.<\/p>\n<p>The PXIe-1085 offers 16 hybrid positions, making it better suited to systems containing numerous hybrid-compatible legacy PXI modules. The PXIe-1095 is better suited to newer high-power PXI Express instrumentation.<\/p>\n<h3>Selecting the Right PXI Express Chassis<\/h3>\n<p>Choose the PXIe-1085 when the system requires 24 GB\/s aggregate bandwidth, 16 hybrid peripheral positions and a dedicated system timing slot.<\/p>\n<p>Select a higher-cooling chassis when any module requires more than 38.25 W. Select a redundant chassis when continuous operation must survive a single power-supply or cooling-component failure.<\/p>\n<h3>Why Choose the PXIe-1085?<\/h3>\n<ul>\n<li>Provides 24 GB\/s aggregate system bandwidth<\/li>\n<li>Supports 16 hybrid-compatible peripheral modules<\/li>\n<li>Includes a dedicated PXI Express system timing slot<\/li>\n<li>Provides 775 W of usable power in the 24 GB\/s version<\/li>\n<li>Supports external 10 MHz reference input and output<\/li>\n<li>Supports PXI and PXI Express star-trigger resources<\/li>\n<li>Provides remote inhibit and voltage monitoring<\/li>\n<li>Uses a serviceable modular power-supply shuttle<\/li>\n<li>Supports embedded and remote-control architectures<\/li>\n<li>Operates from 0\u00b0C to 55\u00b0C<\/li>\n<\/ul>\n<h2>PXIe-1085 Frequently Asked Questions<\/h2>\n<h4>What is the PXIe-1085?<\/h4>\n<p>The PXIe-1085 is an 18-slot high-bandwidth PXI Express chassis for automated test, high-speed acquisition, RF measurement and electronic validation.<\/p>\n<h4>What is the standard PXIe-1085 part number?<\/h4>\n<p>The standard 24 GB\/s version is part number <strong>783588-01<\/strong>.<\/p>\n<h4>What is part number 860869-01?<\/h4>\n<p>Part number 860869-01 is a special ITER configuration. Confirm its backplane specification and project compatibility before using it as a substitute for 783588-01.<\/p>\n<h4>How many peripheral slots does it provide?<\/h4>\n<p>The chassis provides 17 peripheral positions: 16 hybrid slots and one PXI Express system timing slot.<\/p>\n<h4>What is the maximum system bandwidth?<\/h4>\n<p>Standard part number 783588-01 provides up to 24 GB\/s of aggregate system bandwidth.<\/p>\n<h4>What is the maximum available power?<\/h4>\n<p>The 24 GB\/s version provides up to 775 W of usable backplane power. Earlier 12 GB\/s configurations provide up to 791 W.<\/p>\n<h4>What is the maximum peripheral-slot power?<\/h4>\n<p>The maximum permitted peripheral-slot dissipation is 38.25 W. The controller slot supports up to 140 W.<\/p>\n<h4>Does the PXIe-1085 have redundant power supplies?<\/h4>\n<p>No. It uses one replaceable power-supply shuttle and does not provide redundant hardware.<\/p>\n<h4>What is the replacement power-supply part number?<\/h4>\n<p>The compatible replacement power supply is <strong>781719-01<\/strong>.<\/p>\n<h4>Can the power supply be replaced while operating?<\/h4>\n<p>No. Because the chassis has no redundant supply, it must be shut down and disconnected from AC power before replacement.<\/p>\n<h4>Does it include a system timing slot?<\/h4>\n<p>Yes. The standard PXIe-1085 includes one dedicated PXI Express system timing slot.<\/p>\n<h4>Does it support an external reference clock?<\/h4>\n<p>Yes. Front-panel SMA connections provide 10 MHz reference input and output.<\/p>\n<h4>Can conventional PXI modules be installed?<\/h4>\n<p>Compatible hybrid-connector PXI modules can be installed in the 16 hybrid peripheral slots.<\/p>\n<h4>Can the PXIe-1085 be rack mounted?<\/h4>\n<p>Yes. Optional front and rear rack-mount kits support compatible instrument cabinets.<\/p>\n<h4>What is the current lifecycle status?<\/h4>\n<p>NI currently lists standard part number 783588-01 as available, while special part number 860869-01 is shown under Limited Support. Always verify availability using the complete part number.<\/p>\n<h3>Recommended Related Products<\/h3>\n<ul>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/%d0%bf%d0%b8%d0%ba%d1%81%d0%b8-1084\/\">PXIe-1084 18-Slot PXI Express Chassis<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxie-1086\/\">PXIe-1086 18-Slot Redundant AC PXI Express Chassis<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxie-1086dc\/\">PXIe-1086DC 18-Slot Redundant DC PXI Express Chassis<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/%d0%bf%d1%8c%d0%b5-1095\/\">PXIe-1095 18-Slot High-Power PXI Express Chassis<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxie-6674t\/\">PXIe-6674T Timing and Synchronization Module<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxie-8822\/\">PXIe-8822 Quad-Core PXI Embedded Controller<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxie-8842\/\">PXIe-8842 Six-Core PXI Embedded Controller<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxie-8862\/\">PXIe-8862 Eight-Core PXI Embedded Controller<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product-category\/%d0%bd%d0%b8\/pxi-%d1%81%d0%b8%d1%81%d1%82%d0%b5%d0%bc%d1%81\/pxi-chassis\/\">View More NI PXI and PXI Express Chassis<\/a><\/li>\n<\/ul>\n<h3>Request a Quote for the PXIe-1085<\/h3>\n<p>Contact us for current availability, lead time and project pricing for the <strong>NI PXIe-1085 18-Slot 24 GB\/s PXI Express Chassis<\/strong>. Please provide the required part number, controller, module list and destination country so that we can confirm bandwidth, compatibility, power cords and rack-mounting accessories.<\/p>","protected":false},"excerpt":{"rendered":"<p>\u0422\u0438\u043f \u0448\u0430\u0441\u0441\u0438 PXI: PXI Express<br \/>\n\u0422\u0438\u043f \u0431\u043b\u043e\u043a\u0430 \u043f\u0438\u0442\u0430\u043d\u0438\u044f \u0448\u0430\u0441\u0441\u0438: \u043f\u0435\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0439 \u0442\u043e\u043a<br \/>\n\u041a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u0433\u0438\u0431\u0440\u0438\u0434\u043d\u044b\u0445 \u0441\u043b\u043e\u0442\u043e\u0432: 16<br \/>\n\u041a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u0441\u043b\u043e\u0442\u043e\u0432 PXI Express: 1<br \/>\n\u0418\u0437\u0431\u044b\u0442\u043e\u0447\u043d\u044b\u0435 \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u044b\u0435 \u043e\u043f\u0446\u0438\u0438: \u041d\u0435\u0442<br \/>\n\u041c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u0430\u044f \u043f\u0440\u043e\u043f\u0443\u0441\u043a\u043d\u0430\u044f \u0441\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u044c \u0441\u0438\u0441\u0442\u0435\u043c\u044b: 24 \u0413\u0411\/\u0441<br \/>\n\u041a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u0441\u043b\u043e\u0442\u043e\u0432: 18<br \/>\n\u041a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u0441\u043b\u043e\u0442\u043e\u0432 PXI: 0<br \/>\n\u0421\u0438\u0441\u0442\u0435\u043c\u0430: \u0412\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0439 \u0441\u043b\u043e\u0442: \u0414\u0430<br \/>\n\u041c\u043e\u0449\u043d\u043e\u0441\u0442\u044c \u043e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u044f \u0441\u043b\u043e\u0442\u0430: 38 \u0412\u0442<br \/>\n\u0422\u0438\u043f \u0431\u043e\u0440\u0442\u043e\u0432\u043e\u0433\u043e \u0433\u0435\u043d\u0435\u0440\u0430\u0442\u043e\u0440\u0430: VCXO<br \/>\n\u0412\u043d\u0435\u0448\u043d\u0438\u0439 \u0442\u0440\u0438\u0433\u0433\u0435\u0440: \u041d\u0435\u0442<br \/>\n\u0412\u043d\u0435\u0448\u043d\u044f\u044f \u0441\u0438\u043d\u0445\u0440\u043e\u043d\u0438\u0437\u0430\u0446\u0438\u044f: \u0414\u0430<\/p>","protected":false},"featured_media":31668,"template":"","meta":{"_acf_changed":false},"product_brand":[18],"product_cat":[19],"product_tag":[],"class_list":["post-28609","product","type-product","status-publish","has-post-thumbnail","product_brand-national-instruments","product_cat-pxi-chassis","first","instock","sale","shipping-taxable","purchasable","product-type-simple"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.0 (Yoast SEO v28.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>NI PXIe-1085 PXI Chassis 783588-01, In Stock | Project Pricing<\/title>\n<meta name=\"description\" content=\"The PXIe-1085 is an 18-slot all-hybrid PXI Express chassis with 24 GB\/s bandwidth, 775 W power, external clocking and a system timing slot.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/pxisource.com\/ru\/product\/pxie-1085\/\" \/>\n<meta property=\"og:locale\" content=\"ru_RU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"PXIe-1085\" \/>\n<meta property=\"og:description\" content=\"The PXIe-1085 is an 18-slot all-hybrid PXI Express chassis with 24 GB\/s bandwidth, 775 W power, external clocking and a system timing slot.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/pxisource.com\/ru\/product\/pxie-1085\/\" \/>\n<meta property=\"og:site_name\" content=\"PXI Source\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=61582573040385\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-07T07:11:18+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PXIe-1085.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"800\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u0426\u0435\u043d\u0430\" \/>\n\t<meta name=\"twitter:data1\" content=\"&#036;18,000.00\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c\" \/>\n\t<meta name=\"twitter:data2\" content=\"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-1085\\\/\",\"url\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-1085\\\/\",\"name\":\"NI PXIe-1085 PXI Chassis 783588-01, In Stock | Project Pricing\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-1085\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-1085\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/PXIe-1085.webp\",\"datePublished\":\"2025-09-04T06:49:37+00:00\",\"dateModified\":\"2026-09-07T07:11:18+00:00\",\"description\":\"The PXIe-1085 is an 18-slot all-hybrid PXI Express chassis with 24 GB\\\/s bandwidth, 775 W power, external clocking and a system timing slot.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-1085\\\/#breadcrumb\"},\"inLanguage\":\"ru-RU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-1085\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-1085\\\/#primaryimage\",\"url\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/PXIe-1085.webp\",\"contentUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/PXIe-1085.webp\",\"width\":800,\"height\":800,\"caption\":\"PXIe-1085\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-1085\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/pxisource.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\\\/\\\/pxisource.com\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"PXIe-1085\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\",\"url\":\"https:\\\/\\\/pxisource.com\\\/\",\"name\":\"PXI Systems\",\"description\":\"NI PXI, PXIe Modular Test Instrument Supplier\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/pxisource.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ru-RU\"}]}<\/script>\n<meta property=\"product:brand\" content=\"National Instruments\" \/>\n<meta property=\"product:price:amount\" content=\"18000.00\" \/>\n<meta property=\"product:price:currency\" content=\"USD\" \/>\n<meta property=\"og:availability\" content=\"instock\" \/>\n<meta property=\"product:availability\" content=\"instock\" \/>\n<meta property=\"product:condition\" content=\"new\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"NI PXIe-1085 PXI Chassis 783588-01, In Stock | Project Pricing","description":"The PXIe-1085 is an 18-slot all-hybrid PXI Express chassis with 24 GB\/s bandwidth, 775 W power, external clocking and a system timing slot.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/pxisource.com\/ru\/product\/pxie-1085\/","og_locale":"ru_RU","og_type":"article","og_title":"PXIe-1085","og_description":"The PXIe-1085 is an 18-slot all-hybrid PXI Express chassis with 24 GB\/s bandwidth, 775 W power, external clocking and a system timing slot.","og_url":"https:\/\/pxisource.com\/ru\/product\/pxie-1085\/","og_site_name":"PXI Source","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=61582573040385","article_modified_time":"2026-09-07T07:11:18+00:00","og_image":[{"width":800,"height":800,"url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PXIe-1085.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"\u0426\u0435\u043d\u0430":"&#36;18,000.00","\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c":"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/pxisource.com\/product\/pxie-1085\/","url":"https:\/\/pxisource.com\/product\/pxie-1085\/","name":"NI PXIe-1085 PXI Chassis 783588-01, In Stock | Project Pricing","isPartOf":{"@id":"https:\/\/pxisource.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/pxisource.com\/product\/pxie-1085\/#primaryimage"},"image":{"@id":"https:\/\/pxisource.com\/product\/pxie-1085\/#primaryimage"},"thumbnailUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PXIe-1085.webp","datePublished":"2025-09-04T06:49:37+00:00","dateModified":"2026-09-07T07:11:18+00:00","description":"The PXIe-1085 is an 18-slot all-hybrid PXI Express chassis with 24 GB\/s bandwidth, 775 W power, external clocking and a system timing slot.","breadcrumb":{"@id":"https:\/\/pxisource.com\/product\/pxie-1085\/#breadcrumb"},"inLanguage":"ru-RU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/pxisource.com\/product\/pxie-1085\/"]}]},{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/pxisource.com\/product\/pxie-1085\/#primaryimage","url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PXIe-1085.webp","contentUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PXIe-1085.webp","width":800,"height":800,"caption":"PXIe-1085"},{"@type":"BreadcrumbList","@id":"https:\/\/pxisource.com\/product\/pxie-1085\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/pxisource.com\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/pxisource.com\/shop\/"},{"@type":"ListItem","position":3,"name":"PXIe-1085"}]},{"@type":"WebSite","@id":"https:\/\/pxisource.com\/#website","url":"https:\/\/pxisource.com\/","name":"\u0421\u0438\u0441\u0442\u0435\u043c\u044b PXI","description":"NI PXI, PXIe Modular Test Instrument Supplier","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/pxisource.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ru-RU"}]},"product_brand":"National Instruments","product_price_amount":"18000.00","product_price_currency":"USD","og_availability":"instock","product_availability":"instock","product_condition":"new"},"_links":{"self":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/28609","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":14,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/28609\/revisions"}],"predecessor-version":[{"id":36318,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/28609\/revisions\/36318"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media\/31668"}],"wp:attachment":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media?parent=28609"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_brand?post=28609"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_cat?post=28609"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_tag?post=28609"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}