{"id":28535,"date":"2025-09-03T13:11:53","date_gmt":"2025-09-03T05:11:53","guid":{"rendered":"https:\/\/pxisource.com\/?post_type=product&#038;p=28535"},"modified":"2026-09-07T12:44:49","modified_gmt":"2026-09-07T04:44:49","slug":"%d0%bf%d0%ba%d1%81%d0%b8%d0%b5-1088","status":"publish","type":"product","link":"https:\/\/pxisource.com\/ru\/product\/pxie-1088\/","title":{"rendered":"PXIe-1088"},"content":{"rendered":"<h3>PXIe-1088 9-Slot PXI Express Chassis<\/h3>\n<p>\u0417\u0435\u043c\u043b\u044f <strong>NI PXIe-1088<\/strong> is a nine-slot PXI Express chassis designed for automated test, data acquisition, electronic validation and mixed-instrument measurement systems. It combines one system-controller slot with eight hybrid peripheral slots, allowing engineers to install a broad selection of compatible PXI Express and hybrid-compatible PXI modules.<\/p>\n<p>The PXIe-1088 provides up to <strong>8 GB\/s maximum system bandwidth<\/strong>, 329 W of total available DC power and high-capacity forced-air cooling. Slots 2 through 8 can cool modules dissipating as much as 58 W, while slot 9 supports up to 38 W of cooling.<\/p>\n<p>Its all-hybrid peripheral-slot architecture makes the chassis particularly useful when a test system must combine data acquisition modules, oscilloscopes, digital multimeters, programmable power supplies, RF instruments, switches and communication interfaces within one compact platform.<\/p>\n<h3>Key Features of the PXIe-1088<\/h3>\n<ul>\n<li>Nine-slot 3U PXI Express chassis<\/li>\n<li>One dedicated system-controller slot<\/li>\n<li>Eight PXI Express hybrid peripheral slots<\/li>\n<li>All-hybrid peripheral backplane architecture<\/li>\n<li>Up to 8 GB\/s maximum system bandwidth<\/li>\n<li>329 W maximum total available power<\/li>\n<li>Up to 58 W cooling capacity in slots 2 through 8<\/li>\n<li>38 W cooling capacity in slot 9<\/li>\n<li>140 W maximum system-controller slot dissipation<\/li>\n<li>Two 171 CFM module-cooling fans<\/li>\n<li>Internal 10 MHz and 100 MHz reference clocks<\/li>\n<li>100 VAC to 240 VAC nominal universal AC input<\/li>\n<li>Compact benchtop or rack-mountable configuration<\/li>\n<li>Supports embedded and compatible remote-control architectures<\/li>\n<li>Suitable for mixed PXI and PXI Express instrument systems<\/li>\n<\/ul>\n<h2>PXIe-1088 Technical Specifications<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Product Model<\/th>\n<td>PXIe-1088<\/td>\n<\/tr>\n<tr>\n<th>Part Number<\/th>\n<td>784782-01<\/td>\n<\/tr>\n<tr>\n<th>Product Type<\/th>\n<td>PXI Express chassis<\/td>\n<\/tr>\n<tr>\n<th>Chassis Format<\/th>\n<td>3U, 9-slot PXI Express chassis<\/td>\n<\/tr>\n<tr>\n<th>Total Slot Count<\/th>\n<td>9 physical slots<\/td>\n<\/tr>\n<tr>\n<th>System-Controller Slots<\/th>\n<td>1<\/td>\n<\/tr>\n<tr>\n<th>Hybrid Peripheral Slots<\/th>\n<td>8<\/td>\n<\/tr>\n<tr>\n<th>Maximum System Bandwidth<\/th>\n<td>Up to 8 GB\/s<\/td>\n<\/tr>\n<tr>\n<th>System Timing Slot<\/th>\n<td>No dedicated system timing slot<\/td>\n<\/tr>\n<tr>\n<th>External Trigger Access<\/th>\n<td>No integrated external trigger connector<\/td>\n<\/tr>\n<tr>\n<th>External Reference Clock Access<\/th>\n<td>No integrated external clock input or output<\/td>\n<\/tr>\n<tr>\n<th>Onboard Clock Type<\/th>\n<td>VCXO<\/td>\n<\/tr>\n<tr>\n<th>PXI_CLK10 Frequency Accuracy<\/th>\n<td>\u00b125 ppm<\/td>\n<\/tr>\n<tr>\n<th>PXIe_CLK100 Frequency Accuracy<\/th>\n<td>\u00b125 ppm<\/td>\n<\/tr>\n<tr>\n<th>Power-Supply Type<\/th>\n<td>Single AC power supply<\/td>\n<\/tr>\n<tr>\n<th>Redundant Power Option<\/th>\n<td>No<\/td>\n<\/tr>\n<tr>\n<th>Nominal AC Input<\/th>\n<td>100 VAC to 240 VAC, 50\/60 Hz<\/td>\n<\/tr>\n<tr>\n<th>AC Operating Range<\/th>\n<td>90 VAC to 264 VAC, 47 Hz to 63 Hz<\/td>\n<\/tr>\n<tr>\n<th>Maximum Total Available Power<\/th>\n<td>329 W<\/td>\n<\/tr>\n<tr>\n<th>Maximum Combined +3.3 V and +5 V Power<\/th>\n<td>162 W<\/td>\n<\/tr>\n<tr>\n<th>Controller-Slot Power Dissipation<\/th>\n<td>140 W maximum<\/td>\n<\/tr>\n<tr>\n<th>Cooling Capacity, Slots 2\u20138<\/th>\n<td>58 W per slot maximum<\/td>\n<\/tr>\n<tr>\n<th>Cooling Capacity, Slot 9<\/th>\n<td>38 W maximum<\/td>\n<\/tr>\n<tr>\n<th>Module Cooling<\/th>\n<td>Forced-air circulation through two 171 CFM fans<\/td>\n<\/tr>\n<tr>\n<th>Module Airflow Direction<\/th>\n<td>Bottom to top<\/td>\n<\/tr>\n<tr>\n<th>Operating Temperature<\/th>\n<td>0\u00b0C to 50\u00b0C when every peripheral module requires 38 W or less<\/td>\n<\/tr>\n<tr>\n<th>High-Power Operating Temperature<\/th>\n<td>0\u00b0C to 40\u00b0C when any peripheral module requires more than 38 W<\/td>\n<\/tr>\n<tr>\n<th>Operating Humidity<\/th>\n<td>20% to 80%, noncondensing<\/td>\n<\/tr>\n<tr>\n<th>Storage Temperature<\/th>\n<td>\u221240\u00b0C to 71\u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Maximum Operating Altitude<\/th>\n<td>2,000 m at 25\u00b0C ambient with high fan mode<\/td>\n<\/tr>\n<tr>\n<th>Operational Shock<\/th>\n<td>30 g peak, half-sine, 11 ms pulse<\/td>\n<\/tr>\n<tr>\n<th>Operational Random Vibration<\/th>\n<td>5 Hz to 500 Hz, 0.3 grms<\/td>\n<\/tr>\n<tr>\n<th>Dimensions<\/th>\n<td>177.2 \u00d7 355.6 \u00d7 214.2 mm<\/td>\n<\/tr>\n<tr>\n<th>Weight<\/th>\n<td>7.64 kg<\/td>\n<\/tr>\n<tr>\n<th>Intended Environment<\/th>\n<td>Indoor use<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>PXIe-1088 Part Number and Accessories<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Item<\/th>\n<th>Part Number<\/th>\n<th>\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435<\/th>\n<\/tr>\n<tr>\n<td>PXIe-1088<\/td>\n<td>784782-01<\/td>\n<td>9-slot, 8 GB\/s, all-hybrid PXI Express chassis<\/td>\n<\/tr>\n<tr>\n<td>PXIe-1088 Rack-Mount Kit<\/td>\n<td>787525-01<\/td>\n<td>Hardware for installing the chassis in a compatible equipment rack<\/td>\n<\/tr>\n<tr>\n<td>U.S. IEC Power Cord<\/td>\n<td>763830-01<\/td>\n<td>125 VAC, 15 A AC power cord<\/td>\n<\/tr>\n<tr>\n<td>European IEC Power Cord<\/td>\n<td>763067-01<\/td>\n<td>240 V, 10 A right-angle power cord<\/td>\n<\/tr>\n<tr>\n<td>China IEC Power Cord<\/td>\n<td>784686-01<\/td>\n<td>250 V, 10 A power cord<\/td>\n<\/tr>\n<tr>\n<td>Korea IEC Power Cord<\/td>\n<td>784685-01<\/td>\n<td>240 V, 10 A right-angle power cord<\/td>\n<\/tr>\n<tr>\n<td>Brazil IEC Power Cord<\/td>\n<td>785626-01<\/td>\n<td>250 V, 10 A power cord<\/td>\n<\/tr>\n<tr>\n<td>Japan IEC Power Cord<\/td>\n<td>786377-01<\/td>\n<td>125 VAC, 12 A power cord<\/td>\n<\/tr>\n<tr>\n<td>Taiwan IEC Power Cord<\/td>\n<td>787642-01<\/td>\n<td>125 VAC, 15 A power cord<\/td>\n<\/tr>\n<tr>\n<td>India IEC Power Cord<\/td>\n<td>763072-01<\/td>\n<td>250 V power cord<\/td>\n<\/tr>\n<tr>\n<td>Single-Slot Filler Panels<\/td>\n<td>Included<\/td>\n<td>Four filler panels supplied with the standard chassis<\/td>\n<\/tr>\n<tr>\n<td>Double-Slot Filler Panels<\/td>\n<td>Included<\/td>\n<td>Three double-slot filler panels supplied with the standard chassis<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The standard PXIe-1088 package includes the chassis, four single-slot filler panels, three double-slot filler panels and safety, environmental and regulatory documentation. Confirm the regional power-cord requirement and rack-mounting configuration before ordering.<\/p>\n<h3>Nine-Slot All-Hybrid Architecture<\/h3>\n<p>The PXIe-1088 provides nine physical slots: one system-controller slot and eight hybrid peripheral slots. Every peripheral position uses a PXI Express hybrid connector, giving system designers greater freedom when arranging compatible instrumentation.<\/p>\n<p>The all-hybrid design is valuable in mixed-generation systems because it can accommodate PXI Express modules as well as compatible PXI modules that support hybrid-slot installation. Engineers can therefore retain selected existing instruments while adding newer high-bandwidth PXI Express devices.<\/p>\n<p>Module electrical compatibility must still be verified individually. A module must have a compatible backplane connector, supported voltage signaling and suitable software driver before it is installed.<\/p>\n<h3>System-Controller Slot<\/h3>\n<p>Slot 1 is reserved for the system controller. The chassis can be used with a compatible embedded PXI Express controller to create a self-contained measurement system.<\/p>\n<p>A compatible remote-control module may also be installed when an external workstation or industrial computer will control the chassis. The remote architecture requires the correct host interface, PXI Express interface module and connecting cable.<\/p>\n<p>The system-controller slot supports up to 140 W of power dissipation. Wide embedded controllers may occupy adjacent physical space, so controller width must be considered when calculating the remaining number of usable peripheral slots.<\/p>\n<h3>Eight Hybrid Peripheral Slots<\/h3>\n<p>Slots 2 through 9 are hybrid peripheral slots. This arrangement supports flexible placement of oscilloscopes, DAQ cards, waveform generators, DMMs, RF instruments, switches, FPGA modules and communication interfaces.<\/p>\n<p>Before assigning modules to slots, review three requirements: connector compatibility, PCI Express bandwidth and cooling capacity. A module that physically fits may still require a specific link width or more cooling than a particular slot provides.<\/p>\n<p>Slot 9 has a lower cooling capacity than the other peripheral slots. Modules dissipating more than 38 W should be installed only in slots 2 through 8 and must remain within the chassis power and ambient-temperature limits.<\/p>\n<h3>8 GB\/s PXI Express System Bandwidth<\/h3>\n<p>The PXIe-1088 provides up to 8 GB\/s of aggregate system bandwidth between the controller and the chassis backplane. This supports simultaneous communication with several measurement and control modules.<\/p>\n<p>The available bandwidth is shared according to the chassis backplane topology, installed controller and active modules. The maximum performance of a complete system is therefore determined by more than the chassis headline bandwidth.<\/p>\n<p>For high-throughput digitizers, FPGA modules and waveform instruments, review each module\u2019s required PCI Express generation and lane width. Place the highest-bandwidth instruments in suitable slots and calculate the expected combined data rate before finalizing the system.<\/p>\n<h3>PCI Express Slot Planning<\/h3>\n<p>Selected peripheral slots provide higher-bandwidth PCI Express links than other positions. NI identifies slots 4, 6 and 8 as PCI Express Gen 2 \u00d74 connections, supporting a nominal maximum of approximately 2 GB\/s in one direction for each slot.<\/p>\n<p>Slot planning becomes especially important when several instruments stream continuously. A digitizer performing sustained acquisitions may require considerably more backplane bandwidth than a switch, serial interface or low-speed DAQ module.<\/p>\n<p>Place streaming instruments in the higher-bandwidth locations and reserve lower-demand slots for modules that transfer smaller command, status or measurement packets.<\/p>\n<h3>329 W Chassis Power Capacity<\/h3>\n<p>The PXIe-1088 power supply provides a maximum of 329 W to the backplane. The maximum combined power available from the +3.3 V and +5 V rails is 162 W.<\/p>\n<p>System power budgeting should be based on the rail requirements of every installed module, not only the sum of nominal wattage figures. A configuration can remain below 329 W overall while exceeding the allowable current on an individual voltage rail.<\/p>\n<p>The power supply includes short-circuit and overload protection. After an overload is removed, power must be cycled for the outputs to recover and return to regulation.<\/p>\n<h3>58 W Peripheral-Slot Cooling<\/h3>\n<p>Slots 2 through 8 provide up to 58 W of cooling per slot. This capacity supports many higher-performance PXI Express modules that generate more heat than conventional 38 W instruments.<\/p>\n<p>Slot 9 supports a maximum cooling capacity of 38 W. A high-power module must not be installed in slot 9 when its cooling requirement exceeds this rating.<\/p>\n<p>The ambient operating range also changes with module power. When every peripheral module requires 38 W or less, the chassis can operate from 0\u00b0C to 50\u00b0C. If any peripheral module requires more than 38 W, the maximum ambient temperature is reduced to 40\u00b0C.<\/p>\n<h3>Forced-Air Thermal Management<\/h3>\n<p>Two 171 CFM fans provide forced-air circulation through the module area. Cooling air enters through the bottom of the chassis and flows upward through the installed modules before leaving through the top and right side.<\/p>\n<p>The power supply uses its own integrated fans. Power-supply air enters through the front and left side of the chassis and exits from the rear.<\/p>\n<p>Filler panels must be installed over every unused slot. Leaving slots open can disrupt the designed pressure and airflow pattern, allowing air to bypass active modules and reducing cooling effectiveness.<\/p>\n<h3>Cooling Clearance Requirements<\/h3>\n<p>The chassis requires at least 44.45 mm of clearance above, behind and on each side. A rack-mounted chassis also requires at least 44.45 mm below the chassis, while a desktop installation requires at least 25.4 mm below it.<\/p>\n<p>Do not place documents, cables or adjacent equipment over the air intakes and exhaust openings. In a rack, verify that nearby instruments do not discharge heated air directly into the PXIe-1088 intake.<\/p>\n<p>High-power systems should be evaluated under their actual rack temperature, workload and fan configuration rather than using room temperature alone.<\/p>\n<h3>Internal Reference Clock Distribution<\/h3>\n<p>The PXIe-1088 distributes internal 10 MHz and 100 MHz reference clocks through the backplane. These clock resources help compatible PXI instruments coordinate sampling, generation and triggering within the chassis.<\/p>\n<p>The 10 MHz and 100 MHz reference clocks have a specified frequency accuracy of \u00b125 ppm. The PXI_CLK10 slot-to-slot skew is specified at 250 ps, while PXIe_CLK100 slot-to-slot skew is specified at 100 ps.<\/p>\n<p>The chassis does not include front-panel external clock input or output connections. Applications requiring external clock import, export or advanced multi-chassis synchronization may need an appropriate timing and synchronization module.<\/p>\n<h3>No Dedicated System Timing Slot<\/h3>\n<p>The PXIe-1088 does not provide a dedicated PXI Express system timing slot. This distinction is important for applications that require the special differential star-trigger and clock-routing resources associated with a system timing slot.<\/p>\n<p>Standard backplane reference clocks and trigger resources remain available, but the chassis should not be selected under the assumption that it offers a dedicated timing position.<\/p>\n<p>For demanding synchronization applications, compare the PXIe-1088 with a chassis that includes a system timing slot and confirm compatibility with the intended timing module.<\/p>\n<h3>Embedded and Remote Control Options<\/h3>\n<p>An embedded PXI Express controller can be installed in the system slot to create a self-contained test system. This arrangement is convenient for production stations, portable systems and rack installations where the computer and instruments should remain in one chassis.<\/p>\n<p>Remote control allows an external desktop computer, workstation or server to access the PXI Express instrumentation. This can provide more flexibility for CPU selection, graphics processing, storage and integration with existing IT infrastructure.<\/p>\n<p>The correct approach depends on processing requirements, cable distance, environmental conditions and serviceability. Controller and remote-interface compatibility should be confirmed before purchase.<\/p>\n<h3>Benchtop and Rack-Mount Integration<\/h3>\n<p>The chassis measures approximately 177.2 mm high, 355.6 mm wide and 214.2 mm deep, with a weight of approximately 7.64 kg before modules are installed.<\/p>\n<p>Its compact form factor supports benchtop laboratory use as well as installation in a compatible equipment rack. The dedicated rack-mount kit, part number 787525-01, provides the appropriate mounting hardware.<\/p>\n<p>When rack mounting, allow sufficient space for the chassis, installed module connectors, cable bend radius, air intake and exhaust clearance. Heavy cables should be supported so that they do not place unnecessary force on module front panels.<\/p>\n<h2>PXIe-1088 Applications<\/h2>\n<ul>\n<li>Automated electronic test equipment<\/li>\n<li>Production functional testing<\/li>\n<li>Mixed-signal device validation<\/li>\n<li>High-channel-count data acquisition<\/li>\n<li>Automotive electronics testing<\/li>\n<li>Aerospace and defense validation<\/li>\n<li>Semiconductor characterization<\/li>\n<li>RF and wireless-device testing<\/li>\n<li>Power-electronics measurements<\/li>\n<li>Hardware-in-the-loop testing<\/li>\n<li>Research laboratory automation<\/li>\n<li>Multi-instrument stimulus-and-response systems<\/li>\n<\/ul>\n<h3>Automated Production Test<\/h3>\n<p>The PXIe-1088 can serve as the central chassis for production systems combining switching, measurement, stimulus and communication hardware. TestStand, LabVIEW or another compatible environment can coordinate the installed instruments as part of a repeatable automated sequence.<\/p>\n<p>Eight peripheral slots provide useful capacity for systems that require more instrumentation than a compact five-slot chassis but do not need a large 18-slot platform.<\/p>\n<h3>Data Acquisition and Monitoring<\/h3>\n<p>Multifunction DAQ, digitizer, temperature, strain, sound and vibration modules can be installed to create a centralized acquisition system. The hybrid slots allow different measurement technologies to share the same controller and software environment.<\/p>\n<p>Continuous streaming applications should be checked against the per-slot link configuration, aggregate 8 GB\/s chassis bandwidth and controller-storage performance.<\/p>\n<h3>Mixed-Signal Device Validation<\/h3>\n<p>The chassis can combine analog input, analog output, digital I\/O, waveform generation and switching modules for mixed-signal validation. This allows a device under test to receive controlled stimulus while its electrical response is captured and analyzed.<\/p>\n<p>Hardware triggers and backplane timing resources can coordinate multiple instruments more repeatably than independent USB or benchtop devices.<\/p>\n<h3>Automotive and HIL Testing<\/h3>\n<p>Vehicle-network interfaces, fault insertion switches, DAQ modules, FPGA hardware and programmable power instruments can be combined for automotive controller testing.<\/p>\n<p>For deterministic HIL applications, verify real-time controller support, installed module compatibility and the timing requirements of the complete system. The absence of a dedicated system timing slot should be considered when selecting synchronization hardware.<\/p>\n<h3>RF and Wireless Testing<\/h3>\n<p>The PXIe-1088 can host compatible signal generators, analyzers, RF switches and digitizers for wireless-component and subsystem testing.<\/p>\n<p>RF applications often combine substantial data bandwidth and module power. High-throughput instruments should be placed in suitable PCI Express slots, while high-power modules must be kept within the cooling limits for their selected positions.<\/p>\n<h3>Research and Laboratory Automation<\/h3>\n<p>Research teams can use the PXIe-1088 as a reconfigurable platform for instrument control and experimental automation. Modules can be changed as project requirements evolve without replacing the complete test system.<\/p>\n<p>The all-hybrid backplane also helps laboratories integrate supported legacy PXI modules with newer PXI Express instrumentation.<\/p>\n<h2>PXIe-1088 Installation Workflow<\/h2>\n<h4>Step 1: Review the System Configuration<\/h4>\n<p>Create a list of the controller and every peripheral module that will be installed. Record each module\u2019s connector type, width, PCI Express bandwidth, power consumption and cooling requirement.<\/p>\n<h5>Check Module Compatibility<\/h5>\n<p>Confirm that every module supports installation in a PXI Express hybrid peripheral slot. A conventional PXI module with an incompatible connector cannot be installed merely because its front-panel dimensions match.<\/p>\n<h5>Prepare the Power Budget<\/h5>\n<p>Add the module requirements by voltage rail and confirm that the configuration remains within the 329 W total limit, the 162 W combined +3.3 V and +5 V limit and the current capacity of each slot.<\/p>\n<h4>Step 2: Select Benchtop or Rack Installation<\/h4>\n<p>Place the chassis on a stable surface or install it with the compatible rack-mount kit. Maintain the required clearance above, below, behind and on both sides.<\/p>\n<p>Confirm that the airflow openings will remain unobstructed after all cables and neighboring equipment are installed.<\/p>\n<h4>Step 3: Connect Protective Ground Through the Power Cord<\/h4>\n<p>Connect an approved regional IEC power cord to a properly grounded outlet. The power cord provides the primary protective-earth connection and serves as the main power disconnect.<\/p>\n<p>Keep the power connector accessible so that AC power can be removed quickly when servicing the system.<\/p>\n<h4>Step 4: Power Off the Chassis<\/h4>\n<p>Leave the front-panel power switch off while installing the controller and peripheral modules. Do not insert or remove modules while the chassis is operating unless the applicable hardware documentation explicitly supports that procedure.<\/p>\n<h4>Step 5: Install the System Controller<\/h4>\n<p>Insert the compatible embedded controller or remote-control interface into the system slot. Align the module with the card guides, seat it fully in the backplane and tighten its retaining screws.<\/p>\n<p>If the controller occupies more than one slot, account for the lost peripheral positions in the final instrument layout.<\/p>\n<h4>Step 6: Install Peripheral Modules<\/h4>\n<p>Install the highest-bandwidth instruments in the preferred PCI Express positions and place modules requiring more than 38 W of cooling in slots 2 through 8.<\/p>\n<p>Do not install a module requiring more than 38 W of cooling in slot 9. Confirm that wide modules do not obstruct adjacent instruments or interfere with planned cable routing.<\/p>\n<h4>Step 7: Install Filler Panels<\/h4>\n<p>Cover every unused slot with a filler panel. Correct panel installation maintains electromagnetic compatibility, prevents accidental contact and preserves the intended cooling airflow.<\/p>\n<h4>Step 8: Connect Instruments and Fixtures<\/h4>\n<p>Connect the required signal cables, terminal blocks, RF cables and test fixtures. Support heavy cable bundles and maintain an appropriate bend radius near module connectors.<\/p>\n<h4>Step 9: Power On and Detect the Hardware<\/h4>\n<p>Turn on the chassis and start the embedded or external controller. Use NI Measurement &amp; Automation Explorer to confirm that the chassis and installed modules are detected correctly.<\/p>\n<h4>Step 10: Install Drivers and Verify Operation<\/h4>\n<p>Install the driver packages required by the individual instruments. Run self-tests, review the chassis monitoring information and verify each signal path before connecting a valuable device under test.<\/p>\n<h2>PXIe-1088 Troubleshooting<\/h2>\n<h4>The PXIe-1088 Does Not Power On<\/h4>\n<p>Confirm that the IEC power cord is fully connected, the outlet is energized and the front-panel switch is on. Verify that the cord and branch circuit are rated for the regional supply voltage.<\/p>\n<p>Disconnect AC power before inspecting the chassis. The internal fuse is not intended as a routine user-operated reset.<\/p>\n<h4>The Controller Does Not Boot<\/h4>\n<p>Verify that the controller is installed in the system slot and is fully seated. Check the controller\u2019s status indicators, memory and storage configuration according to its documentation.<\/p>\n<p>Remove nonessential peripheral modules temporarily to determine whether a module, power demand or backplane conflict is preventing startup.<\/p>\n<h4>An Installed Module Is Not Detected<\/h4>\n<p>Power down the chassis and reseat the module. Confirm hybrid-slot connector compatibility and install the correct device driver.<\/p>\n<p>Use NI MAX to rescan the system. If the fault follows the module when moved to another compatible slot, inspect the module and its driver configuration.<\/p>\n<h4>A High-Speed Module Has Lower Throughput Than Expected<\/h4>\n<p>Check the module\u2019s slot position, PCI Express link width and controller connection. A module\u2019s headline streaming rate may exceed the capacity of a lower-bandwidth backplane link.<\/p>\n<p>Also verify storage speed, CPU workload, DMA configuration and whether other instruments are sharing the available 8 GB\/s aggregate system bandwidth.<\/p>\n<h4>The Chassis Reports Excessive Temperature<\/h4>\n<p>Check that every unused position has a filler panel and that the bottom intake, top exhaust and side vents are unobstructed. Inspect the fans and remove accumulated dust using an approved maintenance procedure.<\/p>\n<p>If any module requires more than 38 W, keep the ambient temperature at or below 40\u00b0C and install the module only in slots 2 through 8.<\/p>\n<h4>The Fans Are Louder Than Expected<\/h4>\n<p>Higher noise can be normal when the chassis enters a high-performance cooling mode. Fan speed increases with cooling configuration and internal temperature.<\/p>\n<p>Check ambient temperature, airflow clearance and module power. Do not lower cooling performance merely to reduce noise when the installed hardware requires high fan operation.<\/p>\n<h4>The Chassis Shuts Down Under Load<\/h4>\n<p>Review total power and individual voltage-rail requirements. The power supply can enter protection when the system exceeds a current limit or experiences a short circuit.<\/p>\n<p>Disconnect power, remove the overload and inspect the installed hardware. After correcting the condition, cycle AC power to allow the protected outputs to recover.<\/p>\n<h4>Modules Cannot Synchronize to an External Clock<\/h4>\n<p>The PXIe-1088 does not include integrated external reference clock connectors. Install a compatible timing or synchronization module if the system must import or export a clock.<\/p>\n<p>Remember that the chassis also lacks a dedicated system timing slot. Verify that the proposed timing module and routing method are supported in a standard hybrid slot.<\/p>\n<h4>A Legacy PXI Module Does Not Fit<\/h4>\n<p>Not every PXI module supports a hybrid connector. Check the module\u2019s backplane connector and hardware compatibility before attempting installation.<\/p>\n<p>Never force a module into the chassis. Physical resistance may indicate an incompatible connector or incorrect alignment.<\/p>\n<h2>PXIe-1088 Comparison<\/h2>\n<table>\n<tbody>\n<tr>\n<th>\u0424\u0443\u043d\u043a\u0446\u0438\u044f<\/th>\n<th>PXIe-1088<\/th>\n<th>PXIe-1082<\/th>\n<th>PXIe-1092<\/th>\n<\/tr>\n<tr>\n<td>\u041e\u0431\u0449\u0435\u0435 \u043a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u0441\u043b\u043e\u0442\u043e\u0432<\/td>\n<td>9<\/td>\n<td>8<\/td>\n<td>10<\/td>\n<\/tr>\n<tr>\n<td>Hybrid Peripheral Slots<\/td>\n<td>8<\/td>\n<td>4<\/td>\n<td>7<\/td>\n<\/tr>\n<tr>\n<td>Dedicated PXI Express Peripheral Slots<\/td>\n<td>0<\/td>\n<td>2<\/td>\n<td>Configuration dependent<\/td>\n<\/tr>\n<tr>\n<td>System Timing Slot<\/td>\n<td>No<\/td>\n<td>\u0414\u0430<\/td>\n<td>\u0414\u0430<\/td>\n<\/tr>\n<tr>\n<td>Maximum System Bandwidth<\/td>\n<td>8 GB\/s<\/td>\n<td>8 GB\/s<\/td>\n<td>24 \u0413\u0411\/\u0441<\/td>\n<\/tr>\n<tr>\n<td>Maximum Slot Cooling<\/td>\n<td>58 W in slots 2\u20138; 38 W in slot 9<\/td>\n<td>38 \u0412\u0442<\/td>\n<td>Up to 82 W<\/td>\n<\/tr>\n<tr>\n<td>Maximum Available Power<\/td>\n<td>329 W<\/td>\n<td>Chassis dependent on applicable specification<\/td>\n<td>988 W<\/td>\n<\/tr>\n<tr>\n<td>Best Suited For<\/td>\n<td>Flexible all-hybrid, medium-size mixed-instrument systems<\/td>\n<td>Smaller systems requiring a dedicated timing slot<\/td>\n<td>Higher-bandwidth and higher-power applications<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>PXIe-1088 vs PXIe-1082<\/h3>\n<p>The PXIe-1088 provides nine physical slots and eight hybrid peripheral positions, while the PXIe-1082 provides eight physical slots with four hybrid peripheral slots, two dedicated PXI Express peripheral slots and one system timing slot.<\/p>\n<p>Both chassis support up to 8 GB\/s of system bandwidth. The PXIe-1088 offers greater hybrid-slot flexibility and cooling up to 58 W in slots 2 through 8. The PXIe-1082 is preferable when a dedicated system timing slot is required.<\/p>\n<h3>PXIe-1088 vs PXIe-1092<\/h3>\n<p>The PXIe-1092 is a higher-performance chassis offering up to 24 GB\/s of system bandwidth, as much as 82 W of cooling per slot and 988 W of total available power.<\/p>\n<p>The PXIe-1088 is a more compact choice for systems that remain within 8 GB\/s and 329 W. The PXIe-1092 is better suited to multiple high-speed digitizers, RF instruments, FPGA modules or other high-power devices requiring additional bandwidth and cooling.<\/p>\n<h3>Selecting the Right PXI Express Chassis<\/h3>\n<p>Choose the PXIe-1088 when the primary requirements are eight flexible hybrid peripheral slots, moderate system bandwidth and support for modules requiring as much as 58 W of cooling.<\/p>\n<p>Select a chassis with a dedicated system timing slot when specialized synchronization hardware is essential. Choose a 24 GB\/s chassis when several instruments must stream large data sets simultaneously or when higher total power is required.<\/p>\n<h3>Why Choose the PXIe-1088?<\/h3>\n<ul>\n<li>Provides eight flexible hybrid peripheral slots<\/li>\n<li>Supports up to 8 GB\/s of aggregate system bandwidth<\/li>\n<li>Offers 329 W of total available backplane power<\/li>\n<li>Cools modules requiring up to 58 W in slots 2 through 8<\/li>\n<li>Supports mixed PXI and PXI Express instrument configurations<\/li>\n<li>Includes internal PXI_CLK10 and PXIe_CLK100 references<\/li>\n<li>Supports embedded or compatible remote-control systems<\/li>\n<li>Can be used on a bench or installed in an equipment rack<\/li>\n<li>Provides a practical balance of size, compatibility and cooling<\/li>\n<\/ul>\n<h2>PXIe-1088 Frequently Asked Questions<\/h2>\n<h4>What is the PXIe-1088?<\/h4>\n<p>The PXIe-1088 is a nine-slot PXI Express chassis containing one system-controller slot and eight hybrid peripheral slots. It is designed to house and connect modular test and measurement instruments.<\/p>\n<h4>What is the PXIe-1088 part number?<\/h4>\n<p>The standard NI part number for the PXIe-1088 chassis is <strong>784782-01<\/strong>.<\/p>\n<h4>How many peripheral modules can the chassis hold?<\/h4>\n<p>The chassis provides eight physical peripheral slots. The actual number of instruments may be lower when the controller or peripheral modules occupy more than one slot.<\/p>\n<h4>What is the maximum system bandwidth?<\/h4>\n<p>The PXIe-1088 supports up to 8 GB\/s of aggregate system bandwidth. Actual throughput depends on module placement, PCI Express link configuration, the controller and concurrent traffic.<\/p>\n<h4>Are all peripheral slots hybrid slots?<\/h4>\n<p>Yes. All eight peripheral positions use PXI Express hybrid connectors, providing flexible support for compatible PXI Express and hybrid-compatible PXI modules.<\/p>\n<h4>Does the PXIe-1088 have a system timing slot?<\/h4>\n<p>No. The PXIe-1088 does not provide a dedicated PXI Express system timing slot. Applications requiring specialized timing resources should evaluate another chassis or a timing solution supported in a standard hybrid slot.<\/p>\n<h4>Does it provide external clock connectors?<\/h4>\n<p>No. The chassis does not include integrated external clock input or output connections. A compatible timing module is required when an external reference clock must be imported or exported.<\/p>\n<h4>What is the chassis power capacity?<\/h4>\n<p>The power supply provides up to 329 W of total available power. The maximum combined power from the +3.3 V and +5 V rails is 162 W.<\/p>\n<h4>Can every slot cool a 58 W module?<\/h4>\n<p>No. Slots 2 through 8 support up to 58 W of cooling, but slot 9 supports a maximum of 38 W. Total chassis power and ambient-temperature limits must also be observed.<\/p>\n<h4>What temperature range does the PXIe-1088 support?<\/h4>\n<p>It operates from 0\u00b0C to 50\u00b0C when every peripheral module requires 38 W or less. When any peripheral module requires more than 38 W, the supported range is 0\u00b0C to 40\u00b0C.<\/p>\n<h4>Can the PXIe-1088 be rack mounted?<\/h4>\n<p>Yes. The chassis supports rack installation using the compatible rack-mount kit, part number 787525-01. Required airflow clearances must be maintained.<\/p>\n<h4>Can it use an embedded controller?<\/h4>\n<p>Yes. A compatible PXI Express embedded controller can be installed in the system slot to create a self-contained test and measurement system.<\/p>\n<h4>Can it be controlled from an external computer?<\/h4>\n<p>Yes. A compatible remote-control interface, host adapter and cable can connect the chassis to an external computer. The complete remote-control configuration must be selected as a compatible system.<\/p>\n<h4>Why are filler panels important?<\/h4>\n<p>Filler panels cover unused slots, maintain electromagnetic compatibility and preserve the pressure-controlled airflow required to cool installed modules correctly.<\/p>\n<h3>Recommended Related Products<\/h3>\n<ul>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxie-1082\/\">PXIe-1082 8-Slot PXI Express Chassis<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxie-1092\/\">PXIe-1092 10-Slot PXI Express Chassis<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/%d0%bf%d1%8c%d0%b5-1095\/\">PXIe-1095 18-Slot PXI Express Chassis<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/%d0%bf%d0%b8%d0%ba%d1%81%d0%b5%d0%bb%d1%8c-1083\/\">PXIe-1083 Thunderbolt PXI Express Chassis<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxie-8842\/\">PXIe-8842 Embedded Controller<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product\/pxie-8862\/\">PXIe-8862 Embedded Controller<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product-category\/%d0%bd%d0%b8\/pxi-%d1%81%d0%b8%d1%81%d1%82%d0%b5%d0%bc%d1%81\/pxi-chassis\/\">View More NI PXI and PXI Express Chassis<\/a><\/li>\n<li><a href=\"https:\/\/pxisource.com\/ru\/product-category\/%d0%bd%d0%b8\/pxi-%d1%81%d0%b8%d1%81%d1%82%d0%b5%d0%bc%d1%81\/%d0%bc%d0%be%d0%b4%d1%83%d0%bb%d0%b8-pxi\/\">View More NI PXI and PXI Express Modules<\/a><\/li>\n<\/ul>\n<h3>Request a Quote for the PXIe-1088<\/h3>\n<p>Contact us for current availability, lead time and project pricing for the <strong>NI PXIe-1088 9-Slot PXI Express Chassis<\/strong>. We can also help select compatible embedded controllers, remote-control interfaces, rack-mount hardware, regional power cords and PXI instrumentation for your automated test system.<\/p>","protected":false},"excerpt":{"rendered":"<p>\u0422\u0438\u043f \u0448\u0430\u0441\u0441\u0438 PXI: PXI Express<br \/>\n\u0422\u0438\u043f \u0431\u043b\u043e\u043a\u0430 \u043f\u0438\u0442\u0430\u043d\u0438\u044f \u0448\u0430\u0441\u0441\u0438: \u043f\u0435\u0440\u0435\u043c\u0435\u043d\u043d\u044b\u0439 \u0442\u043e\u043a<br \/>\n\u041a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u0433\u0438\u0431\u0440\u0438\u0434\u043d\u044b\u0445 \u0441\u043b\u043e\u0442\u043e\u0432: 8<br \/>\n\u041a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u0441\u043b\u043e\u0442\u043e\u0432 PXI Express: 0<br \/>\n\u0418\u0437\u0431\u044b\u0442\u043e\u0447\u043d\u044b\u0435 \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u044b\u0435 \u043e\u043f\u0446\u0438\u0438: \u041d\u0435\u0442<br \/>\n\u041c\u0430\u043a\u0441\u0438\u043c\u0430\u043b\u044c\u043d\u0430\u044f \u043f\u0440\u043e\u043f\u0443\u0441\u043a\u043d\u0430\u044f \u0441\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u044c \u0441\u0438\u0441\u0442\u0435\u043c\u044b: 8 \u0413\u0411\/\u0441<br \/>\n\u041a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u0441\u043b\u043e\u0442\u043e\u0432: 9<br \/>\n\u041a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u0441\u043b\u043e\u0442\u043e\u0432 PXI: 0<br \/>\n\u0421\u0438\u0441\u0442\u0435\u043c\u043d\u044b\u0439 \u0441\u043b\u043e\u0442 \u0432\u0440\u0435\u043c\u0435\u043d\u0438: \u041d\u0435\u0442<br \/>\n\u041c\u043e\u0449\u043d\u043e\u0441\u0442\u044c \u043e\u0445\u043b\u0430\u0436\u0434\u0435\u043d\u0438\u044f \u0441\u043b\u043e\u0442\u0430: 58 \u0412\u0442<br \/>\n\u0422\u0438\u043f \u0431\u043e\u0440\u0442\u043e\u0432\u043e\u0433\u043e \u0433\u0435\u043d\u0435\u0440\u0430\u0442\u043e\u0440\u0430: VCXO<br \/>\n\u0412\u043d\u0435\u0448\u043d\u0438\u0439 \u0442\u0440\u0438\u0433\u0433\u0435\u0440: \u041d\u0435\u0442<br \/>\n\u0412\u043d\u0435\u0448\u043d\u0435\u0435 \u0442\u0430\u043a\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435: \u041d\u0435\u0442<\/p>","protected":false},"featured_media":31671,"template":"","meta":{"_acf_changed":false},"product_brand":[18],"product_cat":[19],"product_tag":[],"class_list":["post-28535","product","type-product","status-publish","has-post-thumbnail","product_brand-national-instruments","product_cat-pxi-chassis","first","instock","featured","shipping-taxable","purchasable","product-type-simple"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.0 (Yoast SEO v28.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>NI PXIe-1088 PXI Chassis 784782-01, In Stock | Project Pricing<\/title>\n<meta name=\"description\" content=\"PXIe-1088 is a 9-slot PXI Express chassis featuring hybrid slots, high-bandwidth PCIe backplane, integrated timing and synchronization, and robust cooling for automated test and measurement applications.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/pxisource.com\/ru\/product\/\u043f\u043a\u0441\u0438\u0435-1088\/\" \/>\n<meta property=\"og:locale\" content=\"ru_RU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"PXIe-1088\" \/>\n<meta property=\"og:description\" content=\"PXIe-1088 is a 9-slot PXI Express chassis featuring hybrid slots, high-bandwidth PCIe backplane, integrated timing and synchronization, and robust cooling for automated test and measurement applications.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/pxisource.com\/ru\/product\/\u043f\u043a\u0441\u0438\u0435-1088\/\" \/>\n<meta property=\"og:site_name\" content=\"PXI Source\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=61582573040385\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-07T04:44:49+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PXIe-1088.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"800\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u0426\u0435\u043d\u0430\" \/>\n\t<meta name=\"twitter:data1\" content=\"&#036;5,166.00\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c\" \/>\n\t<meta name=\"twitter:data2\" content=\"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-1088\\\/\",\"url\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-1088\\\/\",\"name\":\"NI PXIe-1088 PXI Chassis 784782-01, In Stock | Project Pricing\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-1088\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-1088\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/PXIe-1088.webp\",\"datePublished\":\"2025-09-03T05:11:53+00:00\",\"dateModified\":\"2026-09-07T04:44:49+00:00\",\"description\":\"PXIe-1088 is a 9-slot PXI Express chassis featuring hybrid slots, high-bandwidth PCIe backplane, integrated timing and synchronization, and robust cooling for automated test and measurement applications.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-1088\\\/#breadcrumb\"},\"inLanguage\":\"ru-RU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-1088\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-1088\\\/#primaryimage\",\"url\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/PXIe-1088.webp\",\"contentUrl\":\"https:\\\/\\\/pxisource.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/PXIe-1088.webp\",\"width\":800,\"height\":800,\"caption\":\"PXIe-1088\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/product\\\/pxie-1088\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/pxisource.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\\\/\\\/pxisource.com\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"PXIe-1088\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/pxisource.com\\\/#website\",\"url\":\"https:\\\/\\\/pxisource.com\\\/\",\"name\":\"PXI Systems\",\"description\":\"NI PXI, PXIe Modular Test Instrument Supplier\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/pxisource.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ru-RU\"}]}<\/script>\n<meta property=\"product:brand\" content=\"National Instruments\" \/>\n<meta property=\"product:price:amount\" content=\"5166.00\" \/>\n<meta property=\"product:price:currency\" content=\"USD\" \/>\n<meta property=\"og:availability\" content=\"instock\" \/>\n<meta property=\"product:availability\" content=\"instock\" \/>\n<meta property=\"product:condition\" content=\"new\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"NI PXIe-1088 PXI Chassis 784782-01, In Stock | Project Pricing","description":"PXIe-1088 is a 9-slot PXI Express chassis featuring hybrid slots, high-bandwidth PCIe backplane, integrated timing and synchronization, and robust cooling for automated test and measurement applications.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/pxisource.com\/ru\/product\/\u043f\u043a\u0441\u0438\u0435-1088\/","og_locale":"ru_RU","og_type":"article","og_title":"PXIe-1088","og_description":"PXIe-1088 is a 9-slot PXI Express chassis featuring hybrid slots, high-bandwidth PCIe backplane, integrated timing and synchronization, and robust cooling for automated test and measurement applications.","og_url":"https:\/\/pxisource.com\/ru\/product\/\u043f\u043a\u0441\u0438\u0435-1088\/","og_site_name":"PXI Source","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=61582573040385","article_modified_time":"2026-09-07T04:44:49+00:00","og_image":[{"width":800,"height":800,"url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PXIe-1088.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"\u0426\u0435\u043d\u0430":"&#36;5,166.00","\u0414\u043e\u0441\u0442\u0443\u043f\u043d\u043e\u0441\u0442\u044c":"\u0412 \u043d\u0430\u043b\u0438\u0447\u0438\u0438"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/pxisource.com\/product\/pxie-1088\/","url":"https:\/\/pxisource.com\/product\/pxie-1088\/","name":"NI PXIe-1088 PXI Chassis 784782-01, In Stock | Project Pricing","isPartOf":{"@id":"https:\/\/pxisource.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/pxisource.com\/product\/pxie-1088\/#primaryimage"},"image":{"@id":"https:\/\/pxisource.com\/product\/pxie-1088\/#primaryimage"},"thumbnailUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PXIe-1088.webp","datePublished":"2025-09-03T05:11:53+00:00","dateModified":"2026-09-07T04:44:49+00:00","description":"PXIe-1088 is a 9-slot PXI Express chassis featuring hybrid slots, high-bandwidth PCIe backplane, integrated timing and synchronization, and robust cooling for automated test and measurement applications.","breadcrumb":{"@id":"https:\/\/pxisource.com\/product\/pxie-1088\/#breadcrumb"},"inLanguage":"ru-RU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/pxisource.com\/product\/pxie-1088\/"]}]},{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/pxisource.com\/product\/pxie-1088\/#primaryimage","url":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PXIe-1088.webp","contentUrl":"https:\/\/pxisource.com\/wp-content\/uploads\/2026\/04\/PXIe-1088.webp","width":800,"height":800,"caption":"PXIe-1088"},{"@type":"BreadcrumbList","@id":"https:\/\/pxisource.com\/product\/pxie-1088\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/pxisource.com\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/pxisource.com\/shop\/"},{"@type":"ListItem","position":3,"name":"PXIe-1088"}]},{"@type":"WebSite","@id":"https:\/\/pxisource.com\/#website","url":"https:\/\/pxisource.com\/","name":"\u0421\u0438\u0441\u0442\u0435\u043c\u044b PXI","description":"NI PXI, PXIe Modular Test Instrument Supplier","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/pxisource.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ru-RU"}]},"product_brand":"National Instruments","product_price_amount":"5166.00","product_price_currency":"USD","og_availability":"instock","product_availability":"instock","product_condition":"new"},"_links":{"self":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/28535","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":16,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/28535\/revisions"}],"predecessor-version":[{"id":36307,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product\/28535\/revisions\/36307"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media\/31671"}],"wp:attachment":[{"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/media?parent=28535"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_brand?post=28535"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_cat?post=28535"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pxisource.com\/ru\/wp-json\/wp\/v2\/product_tag?post=28535"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}